Environmental Distribution Center (EDC-06P-NH)

Similar documents
Fiber Connector Shelf (CCS)

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

CORNING. CamSplice User Guide 2. TOOLS AN MATERIALS 1. GENERAL 3. LOADING CAMSPUCE INTO TOOL

INSTALLATION INSTRUCTIONS

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

CS Fiber Optic Splice Case. Instruction

FIBER CONNECTOR SAFETY WARNINGS

Universal Splice Tray Installation Instructions

FL2000 Termination/Splice Panels User Manual

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

8400 Series Fiber Distribution System

COYOTE STP (Service Termination Point)

INSTALLATION INSTRUCTIONS

Instructions for Use - Opt-X 1000i Enclosure

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

COYOTE STP (Service Termination Point)

Opticom Rack Mount Fiber Enclosures

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

Fiber optic splice closure

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

LEXUS GX TOWING HITCH Preparation

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

Fiber Splice Panel Rack Mount User Manual

Fiber Optic Splice Module

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

COYOTE Terminal Dome Closure 6.5" x 22"

Splice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

INSTALLATION INSTRUCTIONS

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

FOSC-100 B/H FOSC-100 B2/H

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

COYOTE LCC (Low Count Closure)

PanView iq (PViQ) Fiber Tray

INSTALLATION INSTRUCTIONS

FOSC-400A4 INSTALLATION INSTRUCTION

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

(31 ) ZEON CONTROL PACK RELOCATION KIT

INSTALLATION INSTRUCTIONS

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

12-Inch Hybrid Fiber Access Terminal Installation Instructions

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

Installation Instructions. QuickSilver Shifter. Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683

Z-Gate Universal Shifter

Instruction Sheet 39mm Patch Panel MT RJ Jack Kits [ ], [ ], and [ ]

Installation Instructions Z-Gate Shifter

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

FlexJet - Flex Cable Replacement

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900 µm Instructions

(31 ) ZEON CONTROL PACK RELOCATION KIT

Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5. Installation Manual

Cab Kit Installation Instructions

INSTALLATION INSTRUCTIONS WINCH MOUNTING KIT Part Number: Application: Honda Rancher TRX420

Installation Instructions

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

INSTALLATION INSTRUCTIONS

CONTENTS: 5740AH - 40 Ton Air/Hydraulic Shop Press 5750AH - 50 Ton Air/Hydraulic Shop Press OWNER'S MANUAL

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900-µm. Instructions. October C

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

SAFETY SENSORS FIELD OF VIEW WILL BE ALTERED WITH USE OF THE REPLACEMENT BUMPER. Injury hazard

Part Name/Description Part Number Quantity Instruction Kit Metalfor Flow Sensor

Zeon Control Pack Relocation Kit 78 Cable Length

Assembly Instructions

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

C Power Connection Kit

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

3M Fiber Dome Closure FDC 10

INSTALLATION INSTRUCTIONS SEMI-HIDDEN WINCH MOUNT Part Number:70005 Application: Ford Super Duty

OPTICAL FIBER CLOSURE

HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM. Parts List and Installation Instructions CAUTION

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

Crimp & Cleave Termination Instructions

WARNING TAKE NOTE OF THE FOLLOWING: THIS PRODUCT MUST BE INSTALLED EXACTLY AS PER THESE INSTRUCTIONS USING ONLY THE HARDWARE SUPPLIED.

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS)

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

Transcription:

Corning Cable Systems Standard Recommended Procedure (SRP) 003-545 Issue 4, July 2004 Page 1 of 13 Environmental Distribution Center (EDC-06P-NH) 1.2 To purchase any accessories that are sold separately, contact your Corning Cable Systems service representative for assistance. 1.3 This document is being reissued to clarify cable cleaning directions. NOTE: Read and understand this procedure (as well as the instructions provided with related assemblies) before beginning an installation. Make sure you know how the unit will be mounted and how the distribution cable and drop cable will be routed to the unit. Table of Contents 1. General...1 2. Description...1 3. Precautions...2 4. Tools and Materials...2 5. Components...3 6. Unpacking Stubbed Units...3 7. Installing Holes...4 8. Mounting...4 9. Preparing Cable...5 10. Connector Panels...7 11. Splicing...8 12. Installing Fan-outs...10 13. Installing Drop Cable...11 14. Maintenance...13 15. Specifications...13 1. General Figure 1 1.1 This instruction describes recommended procedure for the installation of the six-panel Environmental Distribution Center (EDC) (p/n EDC-06P-NH) manufactured by Corning Cable Systems. 2. Description 2.1 The EDC that stores and protects fiber optic connections and splices in an outdoor environment. The cabinet carries a NEMA 250 Type 4X and Type 13 rating in addition to a IEC 529 IP66 rating. The unit provides environmental protection and strain-relief for one distribution cable and up to six drop cables. 2.2 Connector panels are used to provide interconnection between the distribution and drop cables. The EDC accommodates up to six LANscape connector panels. Colored icons are available with different symbols for a quick visual reference of the data type at each connector location. Panels and connector panel icons are ordered separately. 2.3 The unit accommodates six Type 2S or three Type 4S splice trays that protect mechanical or fusion splices. Splice trays are ordered separately. 2.4 The unit can be field connectorized using buffer tube fan-out (BTF) kits, which are ordered separately. 2.5 The EDC comes with brackets to mount the unit to a wall or a standard utility pole. The unit may be rack-mounted with an optional rack-mount kit. p/n 003-545

Page 2 SRP-003-545 Issue 4 July 2004 2.6 The unit may be padlocked with a user supplied padlock after installation of the provided quick-release latch kit. 2.7 Factory stubbed units are available with a specific length of preconnectorized cable installed and strain-relieved in the unit. 3. Precautions 3.1 Laser Handling Precautions 3.3 Glass Fiber Precautions WARNING: Cleaved glass fibers are very sharp and can pierce the skin easily. Do not let cut pieces of fiber stick to your clothing or drop in the work area where they can cause injury later. Use tweezers to pick up cut or broken pieces of the glass fibers and place them on a loop of tape kept for that purpose alone. Good housekeeping is very important. 3.4 Cable Handling Precautions WARNING: Never look directly into the end of a fiber that may be carrying laser light. Laser light may be invisible and can damage your eyes. Viewing it directly does not cause pain. The iris of the eye will not close involuntarily as when viewing a bright light. Consequently, serious damage to the retina of the eye is possible. Should accidental eye exposure to laser light be suspected, arrange for an eye examination immediately. NOTE: Fiber optic cable is sensitive to excessive pulling, bending and crushing forces. Consult the cable specification sheet for the cable you are installing. Do not bend the cable more sharply than the minimum recommended bend radius. Do not apply more pulling force to the cable than specified. Do not crush the cable or allow it to kink. Doing so may cause damage that can alter the transmission characteristics of the cable the cable may have to be replaced. WARNING: DO NOT use magnifiers in the presence of laser radiation. Diffused laser light can cause eye damage if focused with optical instruments. Should accidental eye exposure be suspected, arrange for an eye exam immediately. 3.2 Safety Precautions 3.5 Installer Precautions WARNING: Do not install this unit or work with telephone wiring during a lightning storm. Telephone lines can carry high voltages from lightning causing electrical shock resulting in severe injury or death. CAUTION: The wearing of safety glasses to protect the eyes from accidental injury is strongly recommended when handling chemicals and cutting fiber. Pieces of glass fiber are very sharp and can damage the cornea easily. CAUTION: The wearing of safety gloves to protect hands from accidental injury is strongly recommended when using sharp instruments. CAUTION: Isopropyl alcohol is flammable with a flashpoint at 50 F. It can cause irritation to eyes on contact. In case of eye contact, flush eyes with water for at least 15 minutes. Inhaling fumes may induce mild narcosis. In case of ingestion, consult a physician. 4. Tools and Materials In addition to the usual complement of installation tools, the following are required for this installation: Slotted and Phillips-head screwdrivers Tape measure Pliers 8-mm ( 5 /16-inch) open or box wrench Hole saw Two cable entry port fittings and sealant (if required) Mounting hardware is not provided. The type of hardware used is dependant on the mounting location; wall anchors may be required for adequate support on sheetrock walls.

SRP-003-545 Issue 4 July 2004 Page 3 5. Components 5.1 Components are illustrated in Figure 2. The base plate is the dark metal part inside the enclosure to which the components are attached. It is secured by one screw in each corner. There are top and bottom mounting brackets. The splice tray holder is removed for clarity. The fan-out bracket is underneath the splice tray mounting location. Ground Kit Location (When Required) 5.2 An installation kit is provided that includes cable ties, central member strain-relief hardware, a sheath retention kit and a quickrelease latch kit. 6. Unpacking Stubbed Units Follow the directions in Standard Recommended Procedure 003-310, provided with the shipping container, to remove the stubbed unit from its packaging. Mounting Bracket Radius Control Guides Record Label Splice Tray Mounting Location Splice Tray Holder Central Member Strain-Relief Connector Bracket Panel Bracket Sheath Retention Bracket Drop Cable Strain-Relief Bracket Figure 2

Page 4 SRP-003-545 Issue 4 July 2004 7. Installing Holes IMPORTANT: Remove the base plate from the housing before cutting any holes. 7.1 Determine the size hole needed based on the fitting being used. Based on dimensions in Figure 3, measure and mark the location of the hole centers on the bottom of the unit. The 2- inch conduit fitting holes are represented by the larger circles and the 1-inch conduit holes by the smaller circles. 7.2 Cut holes as required for your coupling fitting. Follow local safety practices. 7.3 Install the fittings (purchased separately). Fitting kits are dependant on the type of fitting desired for your application. 7.4 Reinstall the base plate. 18 cm (7 in.) Stabilizer Bracket 6 cm (2.375 in.) 3.2 cm (1.25 in.) 6.7 cm (2.625 in.) 3.5 cm (1.375 in.) 4.4 cm (1.75 in.) Figure 3 8. Mounting NOTE: If you will be mounting the EDC without the stabilizer bracket, remove and discard the stabilizer bracket. Position the housing as desired and secure using 1 /4-inch screws in the top and bottom mounting brackets. 8.1 When wall-mounting is desired, Figure 4 a) Remove the stabilizer bracket (Figure 4). b) Drive 1 /4-inch screws or wall anchors through the stabilizer bracket and into the mounting surface. Do not install a screw in the bottom hole of the stabilizer bracket at this time. Hang the unit over the mounted stabilizer bracket. Drive a screw through the mounting bracket and stabilizer bracket and into the mounting surface. Figure 5 c) Hang the unit on the stabilizer bracket, ensuring that the top mounting bracket is resting between the two tabs on the stabilizer bracket (Figure 5). d) Align the elliptical hole in the bottom mounting bracket and the bottom hole in the stabilizer bracket and install a 1 /4-inch screw through it and into the mounting surface. e) Mounting hardware is not provided. 8.2 When the EDC will be mounted onto a utility pole: a) Secure the stabilizer bracket to the pole using 1 /4-inch screws. Do not install a screw in the bottom hole of the bracket at this time. b) Hang the EDC on the stabilizer bracket, ensuring that the top mounting bracket is resting between the two tabs on the stabilizer bracket. c) Line up the elliptical hole in the bottom mounting bracket with the bottom hole in the stabilizer bracket and drive a 1 /4-inch screw through the brackets and into the utility pole. d) Mounting hardware is not provided. 8.3 To rack mount the unit, a universal rackmount kit (ordered separately) is required. Remove the stabilizer bracket and follow instructions supplied with the rack-mount kit.

SRP-003-545 Issue 4 July 2004 Page 5 9. Preparing Cable 9.1 Route the incoming distribution (feeder) cable through the fitting on the left at the base of the unit. 9.2 Perform cable sheath removal steps per instructions for the type of cable being installed. Cut the cable to 3 meters (10 feet) inside the unit. NOTE: Do not expose the bare fiber until you are ready to terminate it. 1) Wrap a section of clamp material around the cable to determine the length needed for one full wrap. 2) Use side cutters to cut the clamp material so that it ends up one section shorter than this length. 9.3 Install a sheath retention clamp onto the cable sheath as illustrated in Figure 6. If an armored cable is used, install the ground clamp before installing the sheath retention clamp. 9.4 Armored cable (metallic cable sheath) should be grounded using a ground clamp (Figure 7). Cut a slit into opposite sides of the outer sheath and armor about 5 cm (2 inches). To do this, score the armor with a cable knife (being careful not to damage the inner sheath) and split the sheath by flexing it. 1 2 3 4 2 in. Position the grounding clamp base plate under the armor. The stops of the clamp should just touch the outside of the armor and sheath. Tap the sheath above the ground clamp base to set the teeth. 3) Place the cut length of clamp material 5 cm (2 inch) from the end of the cable sheath. 4) Install a hose clamp over it, covering as many holes as possible. Hand tighten with a slotted screwdriver or a 5/16-inch driver. 5) Wrap the sheath retention assembly with vinyl tape. (Shown without vinyl tape for clarity) Base Plate Stop Position the top plate and lock nut on the outer sheath over the base plate. Tighten with a 10 mm (3/8 inch) wrench so that the teeth on the upper plate are driven into the sheath. Tighten the assembly with a 10 mm (3/8 inch) wrench. Top Plate Armored cable requires a ground clamp. Stop Base Plate Wrap the grounding connector and split portion of the sheath with a few wraps of vinyl tape. Vinyl Tape Figure 6 3.0 cm (1.2 in.) Figure 7

Page 6 SRP-003-545 Issue 4 July 2004 9.5 Secure the cable to the sheath retention bracket using cable ties. Make sure the tabs on the clamp material are in the recessed section of the bracket (Figure 8). Yarn Buffer Tubes Figure 8 9.6 When central member strain-relief is required, the central member bolt must be installed into the strain-relief bracket as shown (Figure 9). NOTE: Smaller diameter central members require a shim to make sure they are adequately secured in the central member clamp. Use a central member clamp shim when necessary (Figure 10). a) Remove the bracket from the housing. b) Install the U-shaped washer as shown in Figure 9. c) Loosely install the hex nut. d) Use two nylon nuts to install the bracket into the housing. e) Insert the central member of the cable between the bracket and the U-shaped washer. f) Arrange the buffer tubes to ensure clearance around the central member clamp assembly and hardware. g) Tighten the hex nut. h) Install the two flat washers. i) Loosely install the other hex nut. j) Wrap the strength member yarn in a clockwise direction around the bolt and between the flat washers. k) Tighten the second hex nut. l) Trim off the excess yarn and central member. NOTE: The exposed length of the central member (after strain-relief) is to be less than or equal to 6.5 cm (2 1 /2 inches) between the U-shaped washer and the end of the cable sheath. Central Member Bracket Figure 9 Insert the central member into the hole in the shim. If the central member does not fit in the hole, discard the shim. If the central member passes through the hole, the shim is required to secure the central member. Position the shim between the U-shaped washer and the bracket U-Washer Shim Central Member Central Member Shim Figure 10 9.7 When cable grounding is necessary, a hardware ground kit (purchased separately) is required. Install the ground kit as shown in Figure 11. Figure 11

SRP-003-545 Issue 4 July 2004 Page 7 10. Connector Panels 10.1 LANscape connector panels (Figure 12) are generally shipped separately with connector adapters installed. NOTE: Pigtails are fiber optic cables with connectors on one end which are installed into connector panels. The other end is terminated in a splice tray. 10.3 Remove the splice tray holder from the housing (Figure 13). 10.4 Install connectors into the appropriate panels (Figure 14). Buffer Tubes Pigtail Figure 12 10.2 If fibers are not already connectorized, install connectors onto the fibers using pigtail splicing or direct connectorization per manufacturer s instructions. If installing BTF kits, proceed to section 12. Figure 14 Splice Tray Holder Splice Tray Holder Bracket Figure 13

Page 8 SRP-003-545 Issue 4 July 2004 CAUTION: The connector is a delicate device. Obey the following precautions. Damage to the surface of the connector will make it unusable: Use a clean tissue soaked in alcohol to gently clean the connector. Do not press heavily on it as you clean. Dry the connector prior to installation with compressed air or a dry tissue. Clean all areas that will contact the connector adapter. Do not force the connector into the receptacle. If the connector does not fit easily into the receptacle, back it out and reinstall. Install threaded connectors into the adapter and tighten. Do not OVERTIGHTEN. Do not allow the connector body (ferrule) to turn as you screw it into place. This causes the surfaces to grind against each other. 10.5 Remove the blank connector panels from the unit (Figure 15). Install the loaded connector panels into the connector support bracket (Figure 16). 10.6 Repeat for all required panels. Pull the plunger fastener out all the way so that the fingers collapse. Position the fastener into the mounting holes in the housing. Plunger Housing 11. Splicing 11.1 The unterminated ends of pigtails are spliced to buffered fibers in a splice tray (Figure 14). Prepare the buffer tubes for splicing. a) Route three complete loops of fiber around the radius guides in a counterclockwise direction. The radius guides are divided into three sections. Begin routing from the back section and work your way forward with each loop in a different section of the guide. b) Reinstall the splice tray holder and install one of the splice trays you will be using. c) Place ALL the buffer tubes as they will lie after installation and mark the cable 2 cm ( 3 /4 inch) from where it will enter the corner of the splice tray as shown in Figure 17. (This is where the buffer tube will be removed.) d) Refer to the instructions provided with the splice tray to determine the appropriate length of fiber required in the tray. Measure from the first mark toward the end of the buffer tubes and mark the buffer tubes. e) Trim the excess buffer tube beyond the second mark. f) Remove the splice tray and the coiled buffer tubes. g) Remove the buffer tubes to the marked point (plus the length needed inside the tray). Strip and clean the fibers according to the cable manufacturer s instructions. Push the plunger in to expand the fingers and lock the unit to the housing. Fingers To remove the unit, pull the plungers out. Figure 15 Figure 16 Figure 17

SRP-003-545 Issue 4 July 2004 Page 9 11.2 Prepare the pigtail for splicing in the same manner. 11.3 Work on one splice tray at a time. Bring both pigtails and buffered fibers to a convenient splicing area - one pair at a time. Secure these fibers to the same corner of the splice tray. IMPORTANT: When securing 900 µm fiber to the splice tray, 1.5 inches of electrical tape around the sheath as protection for the 900 µm fiber is recommended. Feed a cable tie through the strainrelief holes in the corner of the splice tray. Carefully tighten the cable tie around the tape-wrapped portion of the fibers to secure the fibers to the tray. DO NOT tighten the cable tie too tightly. 11.4 Splice fibers as described in instructions for the splicing method you are using. 11.5 As you complete a splice, label the connector end of the pigtail with its port identifier. Record information appropriately on the record label inside the front door (Figure 18). 11.6 Repeat for all required splice trays. 11.7 Place the spliced trays into the holder as shown in Figure 19. The fibers exiting the trays are positioned around the radius control guide. Secure the trays to the holder using the provided hook-and-loop strap. Figure 19 11.8 Once all splicing is complete, route all buffer tubes (beginning at the cable sheath opening) and pigtails (starting at the connector panels) counterclockwise around the radius guides (Figure 20). Figure 18 NOTE: Accurate record keeping is imperative for an organized installation. Figure 20

Page 10 SRP-003-545 Issue 4 July 2004 a) Place pigtails on the outside of the loops and the buffer tubes closest to the guides. b) Make sure the fiber from the connector boot is not pulled too tightly and the bend radius is not violated. c) The first loop should be in the back section of the radius guides and each successive loop should be in the section above the previous loop. d) At the third loop, reinstall the splice tray holder and trays (Figure 21). NOTE: Cable ties can be loosely attached to organize the coils of buffer tubes and pigtail assemblies. 12. Installing Fan-outs 12.1 Fiber optic cable can be installed using BTF kits (ordered separately). 12.2 Slide the splice tray holder toward the top of the housing and remove it. Remove the splice tray holder mounting bracket also (Figure 22). (The fan-out bracket is underneath it.) Splice Tray Holder Splice Tray Holder Bracket Figure 22 Figure 21

SRP-003-545 Issue 4 July 2004 Page 11 12.3 Route the buffer tubes around the radius guides three times in a counterclockwise direction. Mark the location of the fan-out bracket on the buffer tubes as shown in Figure 23 to determine the length required. 12.4 Install fan-out assemblies and connectors according to the instructions provided with the BTF kits. 12.6 Route the connectorized fan-out tubing around the guides and plug connectors into the connector panel (Figure 25). Refer to the previous connector care caution to avoid damaging the connectors during installation. Figure 25 Figure 23 12.5 Route the buffer tubes around the radius guides and secure the fan-out assemblies to the fan-out bracket as shown using a cable tie (Figure 24). 12.7 Label the connector end of the pigtail with its port identifier. Record information appropriately on the record label inside the front door (Figure 18). IMPORTANT: Accurate record keeping is imperative for an organized installation. NOTE: The splice tray holder and its mounting bracket should be reinstalled to allow future splicing capabilities. 13. Installing Drop Cable 13.1 The EDC is designed to accept up to six drop cables. Feed 3 meters (10 feet) of drop cable through the fitting you installed on the right at the base of the closure. 1) Route three complete loops of the subunit around the radius guides (Figure 28). 2) Match the subunits to the corresponding panels and simulate how they will lie. 3) Mark the length on the subunit and trim the cable to this length. 13.2 Gently secure cable with no central members to the bracket using cable ties. Figure 24

Page 12 SRP-003-545 Issue 4 July 2004 13.3 When central member strain-relief is necessary, remove the drop cable strain-relief bracket and secure the cable to the bracket using a cable tie as shown (Figure 26). Strength-Member Yarn U-Shaped Washer Central Member Figure 27 Figure 26 13.4 Route cable around the guides as shown in Figure 28 and plug in connectors. Refer to the connector installation instructions in Section 10 and the fiber precautions in Section 3 to avoid damaging the cable during installation. a) Install the 8-32x 5 /8 screw from the front side of the strain-relief bracket through the flat washer and U-shaped washer. Loosely install the hex nut. b) From the front side of the strain-relief bracket, wrap the strength member yarn in a clockwise direction around the screw and under the U-shaped washer (Figure 27). c) Insert the central member of the cable between the flat washer and the U-shaped washer (Figure 27). d) Tighten the hex nut. e) If the central member is metallic, place the eye of a ground wire (#6 AWG, purchased separately in appropriate length from any electrical supply store) under the U-shaped washer or under the flat washer. f) Trim off the excess yarn and central member. g) Reinstall the strain-relief bracket. NOTE: The exposed length of the central member (after strain-relief) is to be less than or equal to 6.5 cm (2 1 /2 inches) between the U-shaped washer and the end of the cable sheath. Figure 28

SRP-003-545 Issue 4 July 2004 Page 13 14. Maintenance The unit requires very little maintenance to make sure fibers and parts remain in good condition. Loose Parts: Check nuts, bolts and screws for looseness and tighten. Moisture: Check the housing for accumulated moisture and place moisture absorbent packets as needed. Fiber Bends: Check fiber optic cable to make sure bends do not exceed the minimum bend radius. Check cable for unnecessary strain. Check cable entries and exits for crimping or crushing. Documentation: Check record label to make sure it is clear and accurate. 42 cm (16.5 in.) 15. Specifications The unit weighs 6.9 kg (15.2 lb). 21 cm (8.3 in.) 37 cm (14.5 in.) Customer Service US or Canada: 1-800-743-2671 International: +1-828-901-5000 Fax: +1-828-325-5060 Corning Cable Systems LLC, PO Box 489, Hickory, NC 28603-0489 USA http://www.corning.com/cablesystems Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems products without prior notification. Discovering Beyond Imagination is a trademark of Corning Incorporated. LANscape is a trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. 1999, 2000, 2004 Corning Cable Systems. All rights reserved. Published in the USA. p/n 003-545 / July 2004