MAIN FUNCTION FEATURES. . D = v t /2

Similar documents
MAIN FUNCTION FEATURES. . D = v t /2

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

RCM - Direct Reading Flowmeters

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER

Level and Flow Measurement. Sludge Finder 2

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

ISTEC MAGNETIC METERS

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Ultrasonic Non Contact Sensors

NEW. Level Transmitter 2.1. Data sheet

Magnetic Float Level Indicator

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Model DFX Doppler ultrasonic flow meter

Ultrasonic Sludge Blanket Monitoring System

Masoneilan Series

F-2700 SERIES INSERTION VORTEX FLOW METER

Principle of Operation

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

Ultrasonic Sludge Blanket Monitoring System

Level Measurement Products Installation Considerations-Ultrasonic

TRANSIT TIME FLOW METERS

F-2700 SERIES INSERTION VORTEX FLOW METER

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Signet 2551 Magmeter Flow Sensor

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

TUNING FORK LEVEL WORKING PRINCIPLE APPLICATION. Solid Level Detection FEATURE. For Liquid: * Water & Solutions * General Purpose Solvent * Petroleum

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

CAPACITANCE LEVEL SWITCH

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Metal tube variable area flowmeter for gases, liquids and steam

INTRODUCTION / TABLE OF CONTENTS

Signet 2536 Rotor-X Paddlewheel Flow Sensors

F-1500 SERIES INSERTION TURBINE FLOW METER

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

UTM10 Series Ultrasonic Transit-time Flowmeters

INDUSTRIAL PROCESS SENSORS - FOR SEVERE AND DIFFICULT SERVICES -

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

Paddle-wheel flow controller for On/Off control

Level Measurement Continuous level measurement Ultrasonic transmitters

F-2600 SERIES INLINE VORTEX FLOW METER

KEL DIFFERENTIAL PRESSURE FLOWMETERS

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

유량계전문제조업체. Electro Magnetic FLOWMETER

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

RCM. Direct Reading Flowmeter. for Liquids or Gases

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

2100 Turbine Flow Sensor

Marsh McBirney Flo-Dar

SIGNET 7002 Vortex Flow Sensor ENGLISH

process measurement solutions The dry products level control catalogue

Mobrey MSM400 Ultrasonic sludge density measurement system

Paddle-wheel flow controller with optical principle for On/Off control

INSTRUMENTS & TECHNOLOGY

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

mass flowmeter for compressed air

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

Continuous level measuring system. LevelMax. Selection Guide. Overview 2

Paddle-wheel flow controller for On/Off control

INSERTION flow sensor for continuous flow measurement

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

Level Measurement Point level measurement - RF Capacitance switches

flow x3 flow monitoring

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Pressure Transmitter

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

Flow Measurement Technology Training

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

DPT TARGET TYPE FLOWMETERS

CANADA SENSORS TECHNOLOGY INC.

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

Low Profile Insertion Vortex

Inline Ultrasonic Flowmeter

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

Field IT Actuators & Positioners Rotary Actuators - Rated Torque 100 Nm (80 ft-lbs) PME 120-AI/AN. Rotary Actuators Rated Torque 100 NM (80 ft-lbs)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Armstrong In-Line and Insertion Vortex Flow Meters

Range of Ultrasonic Flowmeters.

Product information. ORION-PB Poultry computer for floor keeping

Flow-Alert Flow Switches (Micro Switch)

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

1' to 10' deep and 1' to 25' deep

Transmitting Transducer. Gas/Air Velocity Range:

Electromagnetic Flow Monitor magphant

Time Delta S Fixed Transit-Time Flow Meter System

Plastic tube variable area flowmeter for liquids and gases

Flow meters, Flow switches and Flow transmitters

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Flow Measurement SITRANS F S Clamp-on

Transcription:

ttp e-te com e-ma l o e-te com LT ASONIC LE EL MEAS EMENT Tel -2-22 Fa -2-22 2 INTRODUCTION The ultrasonic level Indicator is a low-cost, noncontact and easy-to-install measurement device. It is able to meet the every-day needs of commercial production, as well serving a more specialized role in the technologically-advanced aero-space industry, thus placing it firmly in the category of high-level measurement technology. Unlike other level indicators with limited uses, the easy-to-install ultrasonic level indicator is a highly-accurate device with enough specialized uses to ensure that the needs of the customer are met. THEORY The principle of operation of the ultrasonic sensor system is to use the ultrasonic pulses which are transmitted by the transducer to the surface to be monitored and are reflected back to the transducer, the time period between transmission and reception of the sound pulses is directly proportional to the distance between the transducer and surface, A micro-controller computes this time period for all echoes received and analyses them to determine which is the correct reflection from the material surface, it uses this data as the basis for giving control outputs and displays in usable engineering units. The distance D is determined from the velocity of sound v and the time period t by the formula: B = Blanking distance D = Distance from transducer to material surface L = Height in silo. D = v t /2 Example: With the velocity of sound v = 334.1 M/s, a time period of 60m/s corresponds to a transmission path of 20.046M and thus to a distance of 10.023M. FEATURES 1. Non-contact. 2. Not effected by material property, such as pressure environments, viscosity and specific gravity. 3. Integrated keypad with security code. 4. Easy installation and low operating costs. 5. Can be used in a versatile of application. 6. Maintenance-free. 7. Easy to set program no need to train personal. 8. The distance between the transducer and control equipment can be up to 300M (Max.). 9. Fully isolated analog output. 10. Better accuracy and stability in difficult conditions. 11. Internal temperature compensation improves accuracy. MAIN FUNCTION 1. Level measurement (height above datum). 2. Distance measurement (distance from a datum). 3. Volume measurement. 4. Differential level measurement. 5. Open channel flow measurement. 6. Pump control. 1

APPLICATION FIELD 1. Sewage/waste water/tapwater treatment equipment. Such as silos, open channels, dams and wells. 2. Liquids such as edible-oils, sauces, diesel oils and beverages. 3. Chemical material such as solvent, paints, carbonic acid, water, crude oil, epoxy resin, lime slurry and wax. Up to 200M 4. Granular materials such as flour, wheat and com. 5. Chemical fibers, petrochemical materials such as plastic powders, plastic granules and plastic chips. 4~20mA PC or PLC PCM 1500 SERIES METER RECORDER AC 110/230V RS232 RS485 DC24V RELAY OUTPUT Hi. ALARM Lo. ALARM Liquid / Powder measurement Silo with rotational aiming kit Flow measurement Foam thickness measurement Measuring in agitator tank Material Mixing Foam thickness Pressure sensor 2

SPECIFICATIONS Compact Type 58 Model: EA-10P(CE) EA-10F(CE) 30B 10 146 Measuring Range: Refer to Table (1) Power Supply: 12~28VDC (0.1A surge) Operating Temp. (In tank): -40BC ~ +70BC (-40BF ~ 158BF) Mounting Screw: 2" NPT(std.) / 2" BSP Measurement Accuracy: 0.25% of measuring range Resolution: 3 mm (0.11")l Housing Type: Integrated (MonoBlock) Housing Material: ABS + UV Enclosure: IP65 Beam Angle: 5 @ 3db point Sensor Material: Aluminum coated ECTEF Sensor Housing: EA-10P: PP, EA-10F: (PVDF) Display: LCD (4-digits 7 segments) Loop current: 2-wire 4~20mA, 750 Ohm @28VDC Weight: 1.5 Kg (3.3Lb) Certificates: CE (EA-10P/F) ATE (Option) 112.5 Table (1) 25 f56.4 EA-10 Measuring Ranges Dead Zone For liquid (Standard) For liquid (Short Range) For solid (Standard) For solid (Short Range) For Open Channels 15M (49ft.) 5M (16.5ft.) 8.5M (28ft.) 5M (16.5ft.) 5M (16.5ft.) 0.6M (2ft.) 0.25M (0.8ft.) 0.6M (2ft.) 0.25M (0.8ft.) 0.2M (0.6ft.) 3

SPECIFICATIONS Separate type Model: EA-20 Measuring Range: Power Supply: Refer to Table (2) 100~240 VAC, 50~60Hz (std.) (via external power supply) Operating Temp. (In tank): -40BC ~ +100BC (-40BF ~ 176BF) Mounting Screw: Measurement Accuracy: 1"NPT( std.) / 1"BSP 0.1~0.25% of measuring range Resolution: 1 mm (0.04") EAB-20 SENSOR Cable: 15M (std.) Housing Type: Housing Material: Enclosure: Beam Angle: Sensor Material: Sensor Housing: Display: Separate ABS + UV IP65 5 @ 3db point Glass reinforced Epoxy PP (std.) / PVDF LCD 80 73 Communication (Options): RS232, RS485 External Modem via RS232 (std.) Loop Current: 4 wire 4~20mA, 750 Ohm @24VDC PC Interface/ Remote Prog.: Options: RS232, RS485 246 Trigger Points: Relays: 10 points (level) 5 Independent SPDT Weight: Enclosure Dimensions: 2.5 Kg (5.5Lb) 272mm x200mm x 85mm 200 58 Certificates: CE, FCC, 3A It's only available for one controller to drive one sensor. f72 f45 15 14 124 Table (2) EA-20 Measuring Ranges Dead Zone Accuracy For liquid For solid Open Channels Diameter 12M (39ft.) 8.5M (28ft.) 12M (39ft.) 3M (8.2ft.) 0.4M (1.3ft.) 0.4M (1.3ft.) 0.4M (1.3ft.) 0.5M (1.6ft.) 0.2% of Measuring Range 0.25% of Measuring Range 0.2% of Measuring Range 0.1% of Measuring Range 4

SPECIFICATIONS Separate type 80 Model: EA-30 EAB-30 SENSOR Cable: 25M (std.) 200 246 f71 58 13 73 17 110 Measuring Range: Power Supply: Standard: 25M for Liquids 20M for Solids Option: 40M for Liquids (Max) 30M for Solids (Max) 100~240 VAC, 50~60Hz (std.) (via external power supply) Operating Temp. (In tank): -40BC ~ +80BC (-40BF ~ 176BF) Mounting Screw: Measurement Accuracy: Resolution: 1 mm (0.04") Housing Type: Housing Material: Enclosure: Beam Angle: Sensor Frequency: Sensor Housing: Display: 1"NPT / 2"NPT / 1"BSP / 2"BSP 0.25% of measuring range Separate ABS + UV IP65 5 @ 3db point 25KHz PP (std.) / PVDF LCD Communication (Options): RS232, RS485 External Modem via RS232 (std.) Loop Current: 4 wire 4~20mA, 750 Ohm @24VDC PC Interface/ Remote Prog.: Options: RS232, RS485 Trigger Points: Relays: Weight: Enclosure Dimensions: Certificates: 10 points (level) 5 Independent SPDT 2.5 Kg (5.5Lb) 272mm x200mm x 85mm CE, FCC, 3A It's only available for one controller to drive one sensor. 5

INSTALLATION Keep transducer perpendicular to liquid. The transducer should not be mounted too close to the tank wall, the build-up on the tank wall cause false echoes. The transducer should not be mounted too close to the tank wall, the bracket can cause strong false echoes. As is illustrated by the figure on the right, the transducer should be mounted on the top of guide tube to prevent the false echoes from turbulence and foam. The guide tube should come with a vent hole at top of the tube to allow the liquid vapor go out of the tube. vent hole Mount the transducer away from the inlet to avoid false echoes. When you mount the transducer on the solid tank, the transducer must point to the tank outlet. 6