Sorensen DLM 3 & 4 kw Series DC Power Supply High Power Density : 3 kw and 4 kw models, 2U (3½ high), (19 wide); no top or bottom clearance spacing required Preview Push-button : Overvoltage protection (OVP), voltage and current preview buttons Remote Sense : Sense leads are easily connected to a solderless connector 3 4 kw 5 600 V 5 450 A 208 230 208 400 480 Parallel or Series Operation Field configurable Power Factor Correction 0.98 1 Ф 3kW The Sorensen DLM 3kW and 4kW Series programmable DC power supplies are designed to provide highly stable, continuously variable output voltage and current for a broad range of applications in a compact 2U ( 3½ high) chassis. Both the 3 kw and 4 kw models have output voltages from 0-5 VDC to 0-600 VDC and a current range from 0-5A to 0-450A. The output rms noise is as low as 10 mv. The output will recover to 1% of its steady-state voltage within 1 ms for a step load change of 100% to 70% or 70% to 100%. The front panel layout makes the series extremely easy to use. Control switches include: power on, enable/ standby and local/ remote. Displays and indicators show programmed set points and operational control status. The programmed voltage, current and overvoltage set points are displayed with two large 3½ digit LED displays. Operational Status LEDs indicate power on, shutdown, over temperature, overvoltage, constant current and voltage mode status. Control Status LEDs indicate front panel lockout, remote control and standby status. IEEE- 488.2 control LEDs indicate error, service request and remote address status. The 3 kw Models will accept 200*/230 VAC single phase and 200*/208 VAC three phase input power. The 4 kw Models will accept 200*/208 VAC, three phase or optional 400 or 480 VAC three phase input power. *Operating temperature below 40 C 858.458.0223 sales@programmablepower.com 51
DLM 3 & 4 kw Series : Product Specifications Common Front Panel Controls Displays and Indicators Overvoltage Protection Cooling Remote Sense Remote Sense Protection Remote Programming Remote Monitoring Operational Features Software Regulatory Environmental Operating Temperature Storage Temperature -40 C to 65 C Physical Dimensions Output Stability Line Regulation Load Regulation Regulation Transient Response Temperature Coefficient Efficiency Knobs with 3½ digit digital displays to control output voltage and current settings. Power on/off switch, output enable/standby switch and local/remote switch., current and overvoltage preview push buttons allow you to preview the programmed settings at any time; overvoltage limit is adjusted with a set screw accessible through the front panel. and overvoltage setting 3½ digit LED display, current setting 3½ digit LED display. LED indicators for power on, shutdown, remote, overvoltage protection, over temperature and front panel lockout, constant voltage and constant current modes. IEEE-488.2 indicators include error, SRQ and address (M9E option). Output overvoltage (resets by cycling the enable/standby switch) Internal fans with over temperature protection The maximum load line drop is up to the full voltage rating of the supply. The drop in the load leads subtracts from the maximum voltage available for the load except as follows: maximum rated voltage is available at the load and voltage regulation specifications apply for line drops of <2V for models rated 5V to 16V, and <5V for all other models. Unit will not be damaged due to misconnection of the remote sense leads., current (0-100%) and OVP (5-110%) of full scale can be programmed by selectable 0-5 VDC, 0-10 VDC, or 0-5 kω. or current can be monitored with user-selectable ranges, 0-5 VDC or 0-10 VDC Master/slave parallel operation, up to 2 units can be connected in parallel with active current sharing control to within 10% of each supply. Series operation, up to 3 units of the same model type can be connected in series (consult manual). Negative terminal rated at 150 Vmax above ground LabVIEW driver M9E/M85 programs can be downloaded at no cost at www.elgar.com CE Mark, 16-185 & 22-180 certified NRTL to EN 61010-1. Marked ccsaus 0 C to 50 C, no derating (<200 VAC range limited to 40 C maximum) Width: 19 (483 mm) Height: 3.5 (88 mm) Depth: 18 (508 mm) Weight 40 lbs. ( 18.2 kg ) Shipping Weight 49 lbs. ( 22.3 kg ) Input 3 kw 4 kw Ranges 180-264 VAC, 47-63 Hz, (<200 VAC range limited to 40 C maximum) Phases single or three phase three phase Power Factor 0.95 typical with three phase input, 0.98 typical with single phase input single phase, 21A rms; three phase, 12A rms ±0.05% of maximum voltage or current over 8 hours after 15 minute warm-up time at fixed line, load and temperature. accuracy for 5V, 8V, and 16V models is 1% typical. For input voltage variation over the AC input voltage range, with constant rated load. : 0.05% of maximum rated output +2mV : 0.1% of maximum rated output For 0-100% load variation, with constant nominal line voltage. : 0.05% of maximum rated output +2mV : 0.1% of maximum rated output 0.05% of maximum rated output +2mV Typically recovers in 1.5 ms to within 1% of steady-state output voltage (greater than 50% of Vmax) for 70-100% or 100-70% load change. 0.02%/ C of rated output voltage; 0.03%/ C of rated output current. Change in output per C change in ambient temperature, with constant line and load. 5-8V Models: 82% typical 16-80V Models: 87% typical 150-600V Models: 85% typical (at maximum output power) 180-264 VAC, 345-455 VAC, 432-528 VAC, 47-63 Hz (<200 VAC range limited to 40 C maximum) 0.95 typical with three phase input 180-264 VAC, 15A rms; 345-455 VAC, 8.5A rms; 432-528 VAC, 6.5A rms; 52 www.programmablepower.com
DLM 3 & 4 kw Series : Product Specifications 3 4 kw Output : and 3 kw Model 4 kw Model DLM 5-350E 0-5 0-350 DLM 5-450E 0-5 0-450 DLM 8-350E 0-8 0-350 DLM 8-450E 0-8 0-450 DLM 16-185E 0-16 0-185 DLM 16-250E 0-16 0-250 DLM 22-180E * 0-22 0-180 DLM 32-95E 0-32 0-95 DLM 32-125E 0-32 0-125 DLM 40-75E 0-40 0-75 DLM 40-100E 0-40 0-100 DLM 60-50E 0-60 0-50 DLM 60-66E 0-60 0-66 DLM 80-37E 0-80 0-37 DLM 80-50E 0-80 0-50 DLM 150-20E 0-150 0-20 DLM 150-26E 0-150 0-26 DLM 300-10E 0-300 0-10 DLM 300-13E 0-300 0-13 DLM 600-5E 0-600 0-5 DLM 600-6.6E 0-600 0-6.6 Output Ratings Regulation Line and Load Meter Accuracy Model (VDC) (ADC) (0.05% of Vmax + 2 mv) (0.1% of Imax) (0.5% of Vmax + 1 count) (0.75% of Imax + 1 count) DLM 5-350E 0-5 0-350 5 mv 350 ma 0.04V 4A DLM 5-450E 0-5 0-450 5 mv 450 ma 0.04V 5A DLM 8-350E 0-8 0-350 6 mv 350 ma 0.05V 4A DLM 8-450E 0-8 0-450 6 mv 450 ma 0.05V 5A DLM 16-185E 0-16 0-185 10 mv 185 ma 0.09V 3A DLM 16-250E 0-16 0-250 10 mv 250 ma 0.09V 3A DLM 22-180E * 0-22 0-180 13 mv 180 ma 0.2V 3A DLM 32-95E 0-32 0-95 18 mv 95 ma 0.3V 0.8A DLM 32-125E 0-32 0-125 18 mv 125 ma 0.3V 1A DLM 40-75E 0-40 0-75 22 mv 75 ma 0.3V 0.7A DLM 40-100E 0-40 0-100 22 mv 100 ma 0.3V 0.9A DLM 60-50E 0-60 0-50 32 mv 50 ma 0.4V 0.5A DLM 60-66E 0-60 0-66 32 mv 66 ma 0.4V 0.6A DLM 80-37E 0-80 0-37 42 mv 37 ma 0.5V 0.4A DLM 80-50E 0-80 0-50 42 mv 50 ma 0.5V 0.5A DLM 150-20E 0-150 0-20 77 mv 20 ma 0.9V 0.3A DLM 150-26E 0-150 0-26 77 mv 26 ma 0.9V 0.3A DLM 300-10E 0-300 0-10 152 mv 10 ma 1.6V 0.09A DLM 300-13E 0-300 0-13 152 mv 13 ma 1.6V 0.11A DLM 600-5E 0-600 0-5 302 mv 5 ma 3.1V 0.05A DLM 600-6.6E 0-600 0-6.6 302 mv 7 ma 3.1V 0.06A * 22V Model available as 4kW 858.458.0223 sales@programmablepower.com 53
DLM 3 & 4 kw Series : Product Specifications Model Preview Accuracy (05% of Vmax +1 count) (1.0% of Imax +1 count) OVP Adjustment Range (6% to 110% Vmax) Ripple & Noise Stability Temp Coefficient Maximum Total Ripple (rms)* Noise (p-p) (0.05% of Vmax) (0.05% of Imax) (0.02% C of Vmax) (0.03% C of Imax) DLM 5-350E 0.04V 5A 0.3-5.5V 12 mv 100 mv 3 mv 175 ma 1 mv 105 ma 2V DLM 5-450E 0.04V 6A 0.3-5.5V 12 mv 100 mv 3 mv 225 ma 1 mv 135 ma 2V DLM 8-350E 0.05V 5A 0.4-8.8V 12 mv 100 mv 4 mv 175 ma 1.6 mv 105 ma 2V DLM 8-450E 0.05V 6A 0.4-8.8V 12 mv 100 mv 4 mv 225 ma 1.6 mv 135 ma 2V DLM 16-185E 0.09V 3A 0.8-17.6V 10 mv 100 mv 8 mv 93 ma 3.2 mv 55 ma 2V DLM 16-250E 0.09V 4A 0.8-17.6V 10 mv 100 mv 8 mv 125 ma 3.2 mv 75 ma 2V DLM 22-180E * 0.2V 3A 1.1-24.2V 10 mv 100 mv 11 mv 90 ma 4.4 ma 54 ma 2V DLM 32-95E 0.3V 1.1A 1.6-35V 10 mv 100 mv 16 mv 48 ma 6 mv 30 ma 5V DLM 32-125E 0.3V 1.4A 1.6-35V 10 mv 100 mv 16 mv 63 ma 6 mv 38 ma 5V DLM 40-75E 0.3V 0.9A 2-44V 10 mv 100 mv 20 mv 38 ma 8 mv 23 ma 5V DLM 40-100E 0.3V 1.1A 2-44V 10 mv 100 mv 20 mv 50 ma 8 mv 30 ma 5V DLM 60-50E 0.4V 0.6A 3-66V 15 mv 100 mv 30 mv 25 ma 12 mv 15 ma 5V DLM 60-66E 0.4V 0.8A 3-66V 15 mv 100 mv 30 mv 33 ma 12 mv 19.8 ma 5V DLM 80-37E 0.5V 0.5A 4-88V 15 mv 120 mv 40 mv 19 ma 16 mv 12 ma 5V DLM 80-50E 0.5V 0.6A 4-88V 15 mv 120 mv 40 mv 25 ma 16 mv 15 ma 5V DLM 150-20E 0.9V 0.3A 7.5-165V 30 mv 200 mv 75 mv 10 ma 30 mv 6 ma 5V DLM 150-26E 0.9V 0.4A 7.5-165V 30 mv 200 mv 75 mv 13 ma 30 mv 7.8 ma 5V DLM 300-10E 1.6V 0.11A 15-330V 60 mv 300 mv 150 mv 5 ma 60 mv 3 ma 5V DLM 300-13E 1.6V 0.14A 15-330V 60 mv 300 mv 150 mv 6.5 ma 60 mv 3.9 ma 5V DLM 600-5E 3.1V 0.06A 30-660V 100 mv 500 mv 300 mv 2.5 ma 120 mv 1.5 ma 5V DLM 600-6.6E 3.1V 0.08A 30-660V 100 mv 500 mv 300 mv 3.3 ma 120 mv 2.0 ma 5V J3 Connector 1 Remote Output Enable 14 Remote Shutdown Input (+). Positive or negative true logic selection with S1 2 Remote Shutdown Return (-) 15 +5 VDC Auxiliary Output 3 Remote OVP Programming Input 16 1 ma Source for OVP Programming 4 Remote Programming Indicator 17 OVP Status Indicator 5 Operating Mode Indicator 18 Over temperature Shutdown Indicator 6 Status Indicator Return (-) 19 DC Monitor Output 7 Monitor Output 20 Remote /Local Control Select 8 Not Used 21 1 ma Source for Programming 9 Programming Input 22 1 ma Source for Programming 10 Programming Input 23 Remote/Local Control Select 11 Not Used 24 Not Used 12 Programming/Monitor Return (-) 25 Not Used 13 Not Used * 22V Model available as 4kW Remote Sense Drop 54 www.programmablepower.com
DLM 3 & 4 kw Series : Diagram 3 4 kw Top View Input Connections Compression lug terminals #6 AWG max wire size Front View Chassis Ground Connection #10-32 threaded stud Output Connections 5V to 80V Copper bus bars, nickel plated Holes in bus bar 0.312 (7.92) 150V to 600V Terminal block with #8-32 screws Rear View Dimensions in inches (millimeters) 858.458.0223 sales@programmablepower.com 55
DLM 3 & 4 kw Series Model Number Description DLM 32 125E (MXX) Series Options Options and Accessories M1 M2 345-455 VAC, 47-63 Hz, three phase, 3 wire plus ground, Delta or WYE may be used (4 kw only) 432-528 VAC, 47-63 Hz, three phase, 3 wire plus ground, Delta or WYE may be used (4 kw only) M9E SCPI compatible IEEE-488.2 and RS-232 interfaces (May not be combined with M51A or M85) M13 M51A M85 Locking shafts (front panel potentiometers) Isolated analog programming (May not be combined with M9C or M85). This isolation allows users to control power supplies not connected to a common ground. In addition, in systems with high ambient noise or with large ground loop currents the control ground can be isolated from the power ground eliminating problems. 12-bit slave interface (May not be combined with M9E or M51A) 5361969-01 Paralleling Cable; one cable per slave unit 105-300-26 Rack slide kit 2009 AMETEK Programmable Power All rights reserved. AMETEK Programmable Power is the trademark of AMETEK Inc., registered in the U.S. and other countries. Elgar, Sorensen, California Instruments, and Power Ten are trademarks of AMETEK Inc., registered in the U.S. 56 www.programmablepower.com