Service to Communication Equipment on PG&E Owned Steel Streetlight Poles with Antenna Provisions

Similar documents
SmartPole Meter for Service to Pole-Mounted Communication Equipment

The Green Meter Adapter (GMA) program will become effective on January 15, Customers may start applying for a GMA on January 15, 2018.

STEEL. P ole P roducts

FREE STANDING WORK STATION JIB CRANE

1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX

SPECIFICATIONS FOR COMMERCIAL CONSTRUCTION

Catalog Number. Notes

Midwest Roadside Safety Facility

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

We have had a request for instructions on how to replace the 50 AMP CR relay in the A/C electrical box with the upgraded 70 AMP relay.

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Electric & Gas Service Requirements (Greenbook) Overview

Utility Distribution Systems Installation, Operation, and Maintenance Manual

Sentinel Field Satellite Controller

KRANE-KING Jib & Gantry Cranes Gantries Free Standing Jibs Tension & Cantilevered Jibs Hoists

Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD

Midwest Roadside Safety Facility

INSTRUCTION MANUAL L WIND CONE

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

Publication No.: PSG

SECTION PIPE HANGERS AND SUPPORTS

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

SECTION LIFT ARM PARKING GATES

Midwest Roadside Safety Facility

7. Residential Single-Family and Duplex Buildings (Dwellings)

TO BE USED FOR MAINTENANCE MICHIGAN DEPARTMENT OF TRANSPORTATION. 2 3/16" x 2 3/16" x 10 Ga. 12" 15.5" 1 1/2" x 1 1/2" x 12 Ga.

Series Base mounted pump. Installation and operating instructions

PROJ. NO SECTION HYDRONIC PUMPS

Three-Phase Pole Mounted Recloser

ACI Hoist & Crane. Festoon System. 689 S.W. 7th Terrace Dania, FL (954) Fax (954) Toll Free A-HOIST ( )

ELECTRIC POLICY INTRODUCTION CHAPTER I GENERAL

SECTION HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS

Midwest Roadside Safety Facility

Top-of-Pole Mount for 12 Modules (TPM12) For Module Types D, E, F, & G When High Wind Version (HWV) or 6h x 2w, L

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

Section 918. ELECTRICAL AND LIGHTING MATERIALS

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

TYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System

Top-of-Pole Mount for 8 Modules (TPM8) For Module Types D, E, F, G, & H ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

Typical Specifications for ECP Helical Torque Anchors

LUM SERIES-PLED w/ POLE RATED FOR 100MPH SHAFT

The Standard Mounting Arrangements for S&C Omni-Rupter Switches

WORK STATION BRIDGE CRANES

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Connect Series Accessories

Please Refer to Attached Sample Form

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter

MULTI-POLE MOUNT LARGE GROUND MOUNT. Assembly Instructions. Assembly Instructions. step-by-step assembly and installation

radial GATES Waterman Industries of Egypt

Top-of-Pole Mount for 15 Modules (TPM15) For Module Types E, F, & G ASSEMBLY INSTRUCTIONS

SNS End Suction Single Stage Centrifugal Pumps

RADIAL GATES USES CONSTRUCTION FEATURES FACE PLATE SEALS

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

SOLAR HEATING SYSTEM

SPECIAL SPECIFICATION 6894 Communication Cabinet

UNDERGROUND SERVICE. Items to consider. There will be charges from ComEd if you convert from overhead to underground service.

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

Owner s Manual. Model 9310 Vehicular Slide Gate Operator

SPECIAL SPECIFICATION 1788 Surveillance Cabinet

Midwest Roadside Safety Facility

ROADWAY LIGHTING SYSTEMS (2545)

Lee County DOT Traffic Section Design Standard for Sign Installation

SECTION 300 OVERHEAD SERVICE

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

SECTION H3 TRAYMASTER SERIES DEAERATORS

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

TD-2306B-001, Interconnecting Large 2-20MW Generation Systems. Employees involved with generation interconnection on electric distribution circuits.

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Special Specification 6058 Battery Back-Up System for Signal Cabinets

GENERAL PROVISIONS: Furnish and install one steel multi-platform motor truck scale and associated electronic controls.

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

(E) 26'-3" STEEL LIGHT POLE

S&C Circuit-Switcher Mark VI Outdoor Transmission (69 kv through 138 kv)

Recreational Vehicle Park Electrical Products & Accessories

Portland General Electric Company Ninth Revision of Sheet No P.U.C. Oregon No. E-18 Canceling Eighth Revision of Sheet No.

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

Revised Cal. P.U.C. Sheet No E Cancelling Revised Cal. P.U.C. Sheet No E

Owner s Manual. Model 9300 Vehicular Slide Gate Operator

2.88 OD Universal Mast Mount

Application for Service Residential Subdivision / Development

AFG501 ALUMINUM FEMA 361 LOUVER LOUVER TYPE RECOMMENDED SPECIFICATION

ISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD

FDOT MODIFICATIONS TO STANDARD SPECIFICATIONS FOR STRUCTURAL SUPPORTS FOR HIGHWAY SIGNS, LUMINAIRES AND TRAFFIC SIGNALS (LTS-5)

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.

Fiber Splice Panel Rack Mount User Manual

REVISIONS. App Thom. App Sud. App PC T.C. 2013/10/01

Change the and later A/C & Heat system on the Discovery coach With the multi-zone coleman mach thermostat

HANDHOLE UNIT. WEB: PHONE: FAX:

VALVES, FIRE HYDRANTS, AND APPURTENANCES


10 Commercial, Industrial, Agricultural Services

Construct Compressed Air Building Near Bldg SECTION OVERHEAD COILING DOORS 07/07

SECTION BASIC ELECTRICAL REQUIREMENTS

SUGGESTED SPECIFICATIONS

Shearing, bending, and rolling capabilities are available along with fabricating from hand drawn sketches to engineered drawings.

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

University of Delaware

Transcription:

SUMMARY This bulletin illustrates the service requirements for the specifically designed steel streetlight pole that is to be used when communication antenna attachments are needed. This bulletin also includes installation information and the required foundation for this pole. Level of Use: Informational Use AFFECTED DOCUMENT 027911, Installation Details for Service to Pole-Mounted Communication Equipment TARGET AUDIENCE Utility employees, electric construction employees, electric restoration employees, customer service representatives, service planning employees, electric estimators WHAT YOU NEED TO KNOW General Information 1 The street light pole is designed to support two communication radios, the antenna and a disconnect switch. See pole details in Figure 1 PG&E Steel Street Light Pole with Attachments on page 3. 2 Install a 2-wire (1-hot, 1-neutral) 1-phase 120 volt service (#6 Cu, 600 V insulated) or a 2-wire (1-hot, 1-neutral) 1-phase 240 volt service along with a #6 bare Cu ground wire to the street light pole with the SmartPole meter. 3 CAUTION: Do not install a 3-wire 1-phase 120/240 volt service as this is the incorrect wiring and voltage for the SmartPole metering application. 4 The metering provision contained herein is an exception to the Greenbook requirement and is designed primarily for CATV power supplies and other telecom equipment requiring metering (reference Tariff Application Guide Electric Rule 9). 5 Power supplies or any communication equipment which has/is connected to a backup power supply, must have a disconnecting device to separate it from PG&E s system. Power units are to have the communication company s name and emergency phone number on them. 6 Antennas: Antennas must have an ownership label with a contact number, site identification information, and a disconnect switch which will shut off RF transmission. The disconnect switch is to be used when it is required as part of the normal or emergency shutdown protocols required in G.O 95, Rule 94. 7 All materials noted as Communication shall be furnished and installed by the requesting communication company. PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 1 of 18

Streetlight Pole Foundation 8 The foundation must be poured in place. Concrete shall be poured directly against the soil. If casing is used, remove the casing as concrete is placed. 9 Concrete shall have a minimum compressive strength of 4000 pounds per square inch in 28 days. 10 Verify all dimensions and any existing elements in the field prior to starting work. 11 Pipes and sleeves shall not pass through structural members except as shown in Figure 13. 12 Steel items other than reinforcing steel bars shall be hot-dipped galvanized in accordance with ASTM A153. 13 Headed reinforcing steel bars, per HRC 555 or equivalent, shall be used. 14 Use non-shrink grout that meets ASTM C1107 requirements. Grout shall have a minimum compressive strength of 5000 pounds per square inch when mixed to the flowable condition. PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 2 of 18

*Fiber may be installed through the PG&E splice box Figure 1 PG&E Steel Streetlight Pole with Attachments PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 3 of 18

Table 1 Bill of Material to be Furnished and Installed by PG&E Item Description Code 1 Street Light Pole See Table 3 2 #6 Al Duplex Street light service 3 #6 Cu 600 V for communications service 4 SmartPole Meter M241490 5 Photo Cell 6 Luminaire Table 2 Bill of Material to be Furnished and Installed by Communication Company Item Description 7 Breaker Box/Load Center 8 #12 Cu 600V (Hot, Neutral, Ground) 9 #2 Cu 600 V Ground 10 Micro Maxcell Innerduct or equivalent 11 Radios or relay units 12 Fiberglass Shroud 13 Diplexers 14 Terminal Block/Splice Connection 15 Hoist Grip for cable support 16 RF Sign 17 0.5 Coaxial Cables 18 Shutoff Sign 19 Ground Rod 20 Antenna 21 Fiber from communication network PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 4 of 18

Table 3A - Material Codes for Streetlight Poles Material Code M150392 Style / Post Height Steel / 26 Ft.- 6 In. Arm Length 4 foot Description Antenna streetlight pole, Steel, 26.5 foot, 4 foot arm, Smooth, Galvanized M150393 Steel / 26 Ft.- 6 In. 6 foot Antenna streetlight pole, Steel, 26.5 foot, 6 foot arm, Smooth, Galvanized M150395 Steel / 26 Ft.- 6 In. 8 foot Antenna streetlight pole, Steel, 26.5 foot, 8 foot arm, Smooth, Galvanized M150396 Steel / 31 Feet 6 foot Antenna streetlight pole, Steel, 31 foot, 6 foot arm, Smooth, Galvanized M150399 Steel / 31 Feet 8 foot Antenna streetlight pole, Steel, 31 foot, 8 foot arm, Smooth, Galvanized Note: The base plate on these poles may be redesigned in the future and any stocked poles could become obsolete, therefore it is suggested a minimal quantity of poles should be stocked. PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 5 of 18

Figure 2 - Wiring Schematic (by Communications Company unless note as by PG&E) PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 6 of 18

Figure 3 - Pole Top Detail PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 7 of 18

Figure 4 - SmartPole Meter Figure 5 3-Pin Receptacle PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 8 of 18

Figure 6 - Wiring Diagram For 3-Pin Receptacle PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 9 of 18

Figure 8 - Shut Down Procedure Sign PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 10 of 18

Figure 9 - Sample RF Sign Figure 10 - Micro Maxcell Innerduct Inside Pole Section Without Cables NOTE: All street light, power, and communication cables are to be isolated using Micro Maxcell Innerduct throughout the pole. PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 11 of 18

Figure 11 PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 12 of 18

Street Light Pole Details Material Specifications: Shaft Steel of 48 K.S.I. minimum yield after fabrication Baseplates and flanges ASTM A-36 Pipe ASTM A-53 GR. B or A-500 GR. B Anchor Bolts ASTM F-1554 GR. 36 Manufacturing Process Finish Coating Butt Welds Ground flush with base metal Longitudinal Welds Butt weld by electrical resistance weld process Circumferential Welds Butt weld with permanent back-up ring Structure Hot dip galvanize per ASTM A-123 Hardware Hot dip galvanize per ASTM A-153 Design Criteria Structure and Hardware In accordance with AASHTO 2001, Specifications for Structural Supports of Highway Signs, Luminaires and Traffic Signals Welding In accordance with AWS D1.1 Orientation See Detail H Note: The base plate on these poles may be redesigned in the future and any stocked poles could become obsolete, therefore it is suggested a minimal quantity of poles should be stocked. Table 3B - Pole Data PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 13 of 18

Table 4 - Arm Data. Figure 12 Street Light Pole PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 14 of 18

Figure 13 Foundation Elevation View Figure 14 Foundation Plan View PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 15 of 18

PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 16 of 18

PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 17 of 18

DOCUMENT APPROVER Connie Taylor, Supervisor, Electric Distribution Standards DOCUMENT CONTACT Daniel Jantz, Engineering Standards Technical Specialist, Expert, Electric Distribution Standards Steve Dannecker, Product Manager, Principal, NRD Fiber and Outdoor Lighting Rich Kauzer, Senior Consulting Standards Engineer, Electric Distribution Standards INCLUSION PLAN This information will be included in the appropriate documents in the 2018 update of the Overhead Construction Manual. PG&E Public 2017 Pacific Gas and Electric Company. All rights reserved. Page 18 of 18