CB33 Pressure Switch CD75 Explosion-Protected Construction Pressure Switch

Similar documents
Fans for ATEX EXPLOSIVE ATMOSPHERES

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

BFG range BFGC range BFN range

BFG range BFGC range BFN range

Explosion Proof (Flameproof) Solenoid Operated Directional Valves. (Old) DSG-01-***-*X*-50. Notice of Model Change

EXPLOSION-PROOF MOTORS SINGLE PHASE

Model 5000 Level Controller

Pressure Switches Type Z

Compact temperature switch Model TCS

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive

Compact pressure switch Model PCS

Pressure switch FF 4 Approval acc. to ATEX EN For mining and chemistry

Model 5000 Level Controller

Mini pressure switch Stainless steel switch enclosure Model PXS

Unused flameproof threads for cable glands have to be closed with certified plugs.

Be prepared with Lutz. Safety is our concern

Compact differential pressure switch Models DC, DCC

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Mini temperature switch Stainless steel switch enclosure Model TXS

Control pressure switch series FF 4

ATEX LABELLING FOR MOTORS AND GEAR UNITS

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

Magnetic Switches for WEKA Visual Level Indicators Australian Version

Series 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2

Hazardous Duty Applications

VL (AZ8) Limit Switches

VL (AZ8) Limit Switches

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

Pressure switch FF up to 250 bar, ample wiring room, easy to adjust high repeatability of set switchpoints, easily read scale

Pump kits. We deliver values.

YFC. Limit switch. Ex d. 24 operating head types

Filtration efficiency: 99% or more HEPO2element

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons Gases

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure

VACUUM A RESOURCE FOR EVERYONE

Flame arresters/vents

Valve Position Monitors

A good connection. International approvals.

Series PMB-D PRC-A PMB-C

P17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A

HD and HDL Single-Stage Non-Lube Gas Compressors

Digital Flow Switch (Sensor Part) Operation Manual

ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Standard Interlock Safety Switches

International approvals.

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)

PFA Lined Ball Valve:Model PF2 PFA. Lined Check Valve: Model PSC20. CATALOGUE No.ZP05 NIPPON VALQUA INDUSTRIES, LTD. NIPPON VALQUA INDUSTRIES, LTD.

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

ARM1000/2000. Standard Specifications

Differential pressure gauges with Bourdon tube

Pressure Instrument Testing Equipment

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

7 NK 72 en Issue 12/99 LIMIT SWITCHES. Series NK700 INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

Installation, Operation & Maintenance of the In-Line Flame Arrestor Model L76L-UF

PPT 802, Proximity Probe Transducer System

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Filtration efficiency: 99% or more

EF 8 EF 9. Company name Idemitsu Nippon Oil Cosmo Oil Showa Shell Sekiyu TonenGeneral Sekiyu Japan Energy

Precision. Consistently.

Pump Kits. More than just pumps

Sensor boxes SRBE Key features and product range overview

Information. Mechanical. Electrical. Chemical. Conversions & Calculations

Petroleum industries are dealing with different hazardous materials starting from storing, processing and distributing the petroleum products These he

O-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON

Azbil Corporation All Rights Reserved.

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

High-pressure switch for gas, air, flue gases and combustion products GW 500 A4 GW A4/2 HP


EL Series Explosion Proof Linear Actuators

Small on price, big on boot

TEMPERATURE AND PRESSURE SWITCHES

by Jim Phillips, P. E.

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Sample Installation: Fixed Power Source (Wall) to Remote/Portable Location

Technical Documentation

TYPICAL APPLICATIONS FOR EL SERIES EXPLOSION-PROOF MOTORS ARE WELL-SUITED TO MANY APPLICATIONS SUCH AS:

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

ROOFMASTER STEF-ATEX ROOF FAN

Installation Instructions - K-Safe-T-Rip Belt Rip Detector

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

Pressure. Pressure. Mechanical. Press. Switches

2 Fluid Level Management

VALIADIS S.A. HELLENIC MOTORS

Adjustable Dead Band Pressure Switches

Electric Top-Guided Single-Seated Control Valves

Pressure controls and thermostats, type KPS

Metallic Systems TYPE SPTC

When ordering, please state type and code number. Suitable sensor length. Max. Cap. range. tube adjust- see also Accessories. sensor. temp.

Mini Magnetic Float Type Level Switch

Hazardous Location Enclosures INDEX. Hazardous Location Enclosures HAZ-2

Commonwealth of Massachusetts Approved Product Approval code G

EZ-View. Flow Meters ISO CERTIFIED 9001

Pressure switch, high adjustability of switch differential

W1000/W3000/W4000/W8000 Series

Local Control Station

SERIES R - MD MOR & GOR

HL (AZH) Limit Switches

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

Transcription:

Cat.No. A6-27 CB Pressure Switch Explosion-Protected Construction Pressure Switch OUTLINE This device is a dead-band adjustable pressure switch designed and manufactured to ensure durability and reliability with an accuracy of.5% max. P. It has excellent vibration-proof characteristics thanks to its double snap action(using Belleville spring) and is therefore ideal in the site for direct control of equipment. FEATURES With the application of a Bellebille spring, this pressure switch demonstrates excellent vibration resistance and durability. (Double Snap Action Mechanism) Adjustable range of dead-band is ~ 2% max. P. Since setting is by multiple rotations (5 rotations / max. P.), accurate setting is possible. Acid-proof coating prevents rusting from salt damage. To keep high accuracy and long life of pressure switch, pressure adjustable range should be to 65% of pressure range. Please pay attention whether wetted parts materials are suitable for gas or liquid to be measured or not. SPECIFICATION Model: CB General process use Explosion-protected construction (Exd II B+H2 T4) Fluid: Gas or liquid Operating condition: CB Under the normal condition, where there is no inflammable gas or liquid which cause the ignition or explosion. Hazardous area The details refer to explanation column of explosion-protected construction. Connection: G/8B(PF), G/2B(PF), Rc/4(PT), Rc/2(PT), /4NPT female, /2NPT( only) For other connections, please contact us. Wetted parts material: Bellows 6Lst.st. Tank socket 6st.st. Please contact us if phosphor bronze bellows (brass body) is required. (CB only) : CB. ~. h.5 ~ 5MPa (. ~ h 5 ~ 5kgf/cm 2 ) -. ~ (- ~ kgf/cm 2 ). ~. h ~ MPa(. ~ h ~ kgf/cm 2 ) -. ~ (- ~ kgf/cm 2 ) Proof-pressure:.5 ~ 2MPa (.5 ~ 2kgf/cm 2 ) (Depending on range) Operating temperature: CB -2 ~ 6g -5 ~ 4g Accuracy: CB.5%max.P..%max.P. Dead band: Adjustable ~ 2%max.P. Switch: Number of contact: One contact (Standard, direct current use) or two contact (Setting dual circuit) Setting system: Internal adjustment type Outlet for electric wire: CB Conduit type PF/2 female Flame-proof packing type Case material finishing: CB Aluminium alloy die casting (ADC2) Blue & Gray Epoxy painted Aluminium alloy casting (AC7A) Blue & Gray Epoxy painted Construction: IP65

SPECIFICATION 2 Terminal box:(option)cb only Although the wire used to have to be removed from the terminal plate and the tester terminal pressed against it when measuring contact resistance, with the provision of a check terminal, simply remove the screws on the terminal plate and insert the terminals of the tester. This ensures stability when measuring and eliminates the trouble of removing the wire from the terminal plate. Operation lamp:(option) CB only The on/off state of the pressure switch and the operating state of the microswitch can also be confirmed at a glance. Weight: CB Approx. 2kgs Approx. 5kgs Electric characteristics: Switch Rating Load resistance Inductive load Withstand voltage Insulation resistance Single setting 25V AC 25V AC 25V DC 25V DC A A.5A.25A 6A 4A.5A.A Single setting direct current use Single setting dual circuits 25V AC 25V AC 25V DC 25V DC 25V AC 25V AC 25V DC 25V DC A A A A A A.5A.25A 6A.5A 6A.5A 6A 4A.5A.A 2V AC Beween terminal and case minute 5V DC MΩ over Beween terminal and case Inductive load :Power factor.4 over(ac) Time-constant 7ms or less(dc) One contact direct current use: Direct current rating is bigger than standard. and dead band Proof-pressure: MPa(kgf/cm 2 ) (Adjustable range) Dead band MPa(kgf/cm 2 ) (Adjustable range) Proof-pressure MPa(kgf/cm 2 ) -. ~ (-~ ).~.2 (.~.2).5 (.5).~. (.~ ).~.2 (.~.2).5 (.5).2~.2 (.2~ 2).6~.4 (.6~.4). ().~. (.~ ).9~.6 (.9~.6).45 (4.5).4~.4 (.4~ 4).2~.8 (.2~.8).6 (6).6~.6 (.6~ 6).8~.2 (.8~.2).9 (9). ~ (~ ). ~.2 (. ~ 2).5 (5).5~.5 (.5~ 5).45~. (.45~ ) 2.25 (22.5).2 ~2 (2~ 2).6 ~.4 (.6 ~ 4) (). ~ (~ ).9 ~.6 (.9 ~ 6) 4.5 (45).5 ~5 (5~ 5).5 ~ (.5 ~ ) 7.5 (75).7 ~7 (7~ 7).2 ~.4 (2. ~ 4).5 (5) ~ (~). ~2 ( ~ 2) 5 (5).5 ~5 (5~5) CB only.75 ~ (7.5 ~ ) 2 (2)

DIMENSIONS CB (.8) 5. 8 26.5 92 DIA. 8-6 DIA. Mounting hole 96 For range.mpa 8 (kgf/cm 2 ) or less 2 77 69 NAGANO KEIKI 5 69 (2.5) Bracket For range.mpa (kgf/cm 2 ) or less 45 22 PF/2 5 6 G/2B(PF).4,.6,,.5,2,MPa (4,6,,5,2, kgf/cm 2 ) 2 24X27.7 Hex. 24x27.7 G/2B (PF) 82 DIA. 2 49.2,.MPa (2,kgf/cm 2 ) 24 Flats G/2B (PF) 2 5,7,,5MPa (5,7,,5 kgf/cm 2 ) 42 55 G/2B (PF) 9 DIA. 2 6 G/2B (PF) 9 DIA. 2 49 -.MPa (-kgf/cm 2 ).MPa (kgf/cm 2 ) Dimensions marked with are also applied to.mpa (kgf/cm 2 ) Option Neon lamp or LED

DIMENSIONS 2.4,.6,,.5,2,MPa (4,6,,5,2,kgf/cm 2 ) Panel mounting 4 4 DIA. 7 Terminal box (2) 7 2 4 27 94 8 (9) 48 (274.5) 4 DIA. 4.5 5. 7.5 2 Flame-proof packing type () DIA. G/2B(PF) 54 5,7,MPa (5,7,kgf/cm 2 ) -.MPa (-kgf/cm 2 ) (9) (46) 2 G/2B (PF) 2 9 DIA. G/2B (PF) 42.MPa (kgf/cm 2 ) Dimensions marked with are also applied to.mpa (kgf/cm 2 ) () 2 9 DIA. G/2B(PF).,.2,.MPa (,2,kgf/cm 2 ) 4 2B pipe mounting (62) (2) 7 (2.5) 4 4 27 94 8 (48) 2 DIA. (2) 4.5 7.5 7 5. (6) 27 G/2B (PF) 2B pipe.75 M8 (98)

EXPLOSION-PROTECTED CONSTRUCTION Type approval for explosion-proof: () It acquires a technical standard adjusted in international standard IEC by the ministry of Labor notification and the national authorization on the basis of new explosion proof guide. Type name Type approval number No.C24 Explosion-protected construction: Explosion protected-construction is a totally enclosed construction such that even if the explosive gas explodes inside the container, the container withstands the force of the explosion and there is no danger of ignition of external explosive gases. As for our pressure switch produced based on this policy, use can have combustible gases or steam of combustibility liquid in pressure measurement at a place with existing fear in a factory, other business office. Exd II+H2 T4 : Ex d II B+H2 T4 Temperature class II B+H2:Hydrogen gas is also contains in II B group A sign of explosion proof construction Group classification A kind of explosion proof electrical instrument and apparatus is classed in group I and group II by a place to be used. belongs to group II, and comes under machinery using it in a factory except hazardous location of the mine or hazardous location of business office. Applicable group and classification of gas or steam. Classification of gas or steam Applicable group A II A II B IIC B C IIB IIC IIC Ignition point of gas or steam which T4 can apply. Ignition point of gas or steam Higher than 45g Higher than g Higher than 2g Higher than 5g Applicable temperature class T T2 T T4 T5 T6 T2 T T4 T5 T6 T T4 T5 T6 T4 T5 T6 Higher than g Higher than 85g T5 T6 T6 Example of applicable gas or steam. Temperature class T T2 T T4 T5 T6 Group Acetone Ethanol Hexane Acetaldehyde Ammonia -butanol Carbon monoxide Butane Ethane Acetic acid IIA Ethyl acetate Toluene Propane Benzene Methanol Methane IIB IIC Hydrogen Ethylene Ethylenoxide Acetylene Ethylmethyl Ether Carbon bisulfide Nitric acid ethyl

WIRING CB SW SW INC. DEC. Terminal division a : b : c : a c b Terminal INC. DEC. COM Ṅ.C. Terminal 2SW (D.P.D.T.) INC. DEC. Terminal division a.2a : b.2b : c.2c : a c b 2a 2c 2b Terminal 2SW(D.P.D.T.) INC. DEC. 2 2 2 Terminal OUTLET FOR ELECTRIC WIRE Conduit Connection Packing inner DIA.(d) Applicable cable Out DIA. Protecting tube Connection PF/2 8 DIA.~2 DIA. mm step 7. DIA.~2. DIA..5mm step PF/2 PF/4 DIA.~6 DIA. mm step 2. DIA.~6. DIA..5mm step PF/4 Terminal box PF 7 DIA.~2 DIA. mm step 6. DIA.~2. DIA..5mm step PF Washer Ring packing ME set screw Cable gland Cable clamp Cable protecting tube connection Applicable cable out DIA.

Type No. constitution Please specify Type No.,each specification and range when ordering. Note:For this Model,there is no applicable item for the figures X,but please specify X when ordering. Pressure switch C B Type No. Selection spec. Additional spec. (Option) 2 4 5 6 7 8 9 2 4 5 2 Other additional spec. Switch Single setting S.P.D.T. Single setting direct current use S.P.D.T. 2 Single setting dual circuit D.P.D.T. 2 Connection 4 7 9 X G/8B G/2B Rc /4 Rc /2 /4NPT female Please specify your requirement For nuclear power plant, bracket, case finishing For range.mpa or less, bracket is equipped as standard. Operation lamp 5 With LED(24V DC) With neon lamp(v AC) With neon lamp(22v AC) 9 Terminal box W/Check terminal 8 Treatment Wetted parts material Socket:6st.st.,Bellows:6Lst.st. 2 Use no oil Use no water Use no oil & water 7 Outlet for electric wire 4 (MPa) (When ordering, please specify pressure range & unit.) -. ~ 2. ~.,.2 ~.2,. ~..4 ~.4,.6 ~.6,. ~.5 ~.5,.2 ~ 2,. ~ 4.5 ~ 5,.7 ~ 7, ~,.5 ~ 5 2 Conduit PF/2 female 6 Switch Standard Standard + gold plated 5 Document 5 Type of contact H:Upper limit type with one contact 2 L:Lower limit type with one contact 4 2H:Upper limit type with two contact 5 2L:Lower limit type with two contact Please specify your requirement Drawing one sheet, Instruction manual, Inspection procedure, Mill sheet, Test report Appoint old model model in case of hope extra.

I Type No. constitution Please specify Type No.,each specification and range when ordering. Note:For this Model,there is no applicable item for the figures X,but please specify X when ordering. Pressure switch Type No. Selection spec. Additional spec.(option) 2 4 5 6 7 8 9 2 4 5 Mounting type Panel mounting, Flame-proof packing type 7 2B pipe mounting, Flame-proof packing type 2 Connection 4 7 9 M X G/8B G/2B Rc /4 Rc /2 /2NPT /4NPT female 8 Treatment 2 9 Other additional spec. Please specify your requirement Case finishing Use no oil Use no water Use no oil & water Switch 2 4 (MPa) (When ordering, please specify pressure range & unit.) -. ~ Single setting (S.P.D.T.) Single setting direct current use (S.P.D.T.) Single setting dual circuit (D.P.D.T.) 2. ~,.2 ~.2,. ~..4 ~.4,.6 ~.6,. ~,.5 ~.5,.2 ~ 2,. ~ 4.5 ~ 5,.7 ~ 7, ~ 7 Outlet for electric wire Packing inner DIA.mm (PF/2 female) 4 Packing inner DIA.2mm (PF/2 female) 6 Packing inner DIA.4mm (PF/4 female) 8 Packing inner DIA.6mm (PF/4 female) A Packing inner DIA.7mm (PF female) Since the inside diameter of the packing can be manufactured in -mm step, please consult us for other cases. 5 Document 5 Type of contact H :Upper limit type with one contact 2 L :Lower limit type with one contact 4 2H:Upper limit type with two contact 5 2L:Lower limit type with two contact 6 Switch Standard Standard + gold plated Please specify your requirement Drawing one sheet, Instruction manual, Inspection procedure, Mill sheet, Test report The contents in the catalogue are subject to change without notice. Q u a ISO 9 NA GA NO l i t y S KE t y s I K e m UEDA FACTORY (JQA-794) MARUKO FACTORY (JQA-789) HEAD OFFICE & OVERSEAS : --4, HIGASHIMAGOME OHTA-KU, TOKYO, JAPAN. TELEPHONE : (776) 528 SALES DEPT FAX TELEX : (776) 5447 : 2468452 NKSTKY J OVERSEAS PLANTS OR AFFILIATES: U.S.A., KOREA, GERMANY OVERSEAS SALES NETWORK: AUSTRALIA, HONG KONG, INDONESIA, KOREA, MALAYSIA, PHILIPPINES, SINGAPORE, TAIWAN, THAILAND, U.S.A. PRINTED IN JAPAN '97.2.A