Paddle-wheel flow controller for On/Off control

Similar documents
Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller with optical principle for On/Off control

INSERTION flow sensor for continuous flow measurement

INSERTION flowmeter with paddle wheel, ELEMENT design

Insertion magnetic inductive flowmeter

Positive displacement batch controller

Positive displacement flowmeter

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Positive displacement flowmeter for continuous flow measurement

INLINE fitting with paddle-wheel for flow measurement

Digital ph transmitter

Digital ph transmitter

INLINE sensor-fitting with paddle wheel for flow measurement

INLINE fitting with paddle-wheel for flow measurement

Inductive conductivity meter

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Inductive conductivity meter

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Inline Paddle Wheel Flow Switch

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

INSERTION Adaptor for analysis

INSERTION fitting for flow measurement or analysis

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

MAGNETIC INDUCTIVE FLOW TRANSMITTER

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

PROPORTIONAL VALVES Sentronic D - G 1/8 to G 3/8 tapped body or G 1/8 - G 1/4 subbase mounted body with digital pressure control

Flow Transmitter / Switch OMNI-RR..32

BBF8032. Brass Paddle Wheel Flowmeter and Transmitter

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

Flow Transmitter / Switch OMNI-RR..32

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Pressure transmitters for heavy duty applications Type MBS 3250

Model Pressure range ON/OFF output Linear output

Type Pressure Transmitter with display. Pressure Transmitter. Technical data. DN15-50 Body material. Stainless steel 316L Actuator material

2/2-way Angle-Seat Control Valve with stainless steel design for media up to +185ºC, DN15-65

2/2-way Globe Control Valve, threaded port connection, DN 10-65

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Signet 2551 Magmeter Flow Sensor

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Electrical position feedback for actuator sizes Ø mm

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Servotronic Digital 615 Series

Flow Transmitter / Switch OMNI-RR..32

2/2-way Diaphragm Valve with stainless steel design, weld end or clamp connection, DN 8-25

2/2 way Angle-Seat Valve for medium up to C, DN15-50

Turbotron // VTH15, VTM15, VTP15, VTI15

Electronic Pressure Switches

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

2/2 way Globe Control Valve, threaded connection, 3/8" 3"

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Sentronic D 608 Series and 609 Series

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

AirLINE and AirLINE Quick electrical/pneumatic Automation System

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

Electronic Pressure Switches

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

Sentronic LP IO-Link CLASS A 617 Series. Proportional Technology

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

DTK. OEM Pelton Wheel Flow Sensor

flow x3 flow monitoring

Direct-acting 3/2 way plunger valve

Type SE35. Quickstart. English. Flowmeter Flow Transmitter

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

mass flowmeter for compressed air

2/2-way Globe Valve for media up to +180 C, DN

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

FLOWX3 F3.60M.S Insertion Magmeter

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

2/2-way Globe Valve for media up to +180 C, DN

MBS 1200 and MBS 1250

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Index Flow Sensors FLOWX3 F3.00 Paddlewheel Flow Sensor page 2 FLOWX3 F111 Hot Tap Flow Sensor page 18 FLOWX3 F3.60M Insertion Magmeter page 24 FLOWX3

Flow - dynamic diaphragm

3/2-way Solenoid Valve, direct-acting, NC or NO

ISTEC MAGNETIC METERS

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

PROPORTIONAL VALVES. G1/4, G3/8 and G1/2 tapped body or subbase mounted body with digital pressure control

Model Pressure range ON/OFF output Linear output

Pressure transmitter for marine applications MBS 3100 and MBS 3150

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

G2 Industrial Grade Meters

PSF50 Paddle flow switch

2/2 or 3/2 way direct acting rocker solenoid valve

Sentronic PLUS 614 Series

Temperature switch. Switching output 2 transistors PNP Logger Ring buffer: 3518 data points Sampling time: s, Off (0)

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

Transcription:

Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration: Teach-In Communication - external setpoints and process value (4-0 ma) Type 70 (8630) Type 067 Type 8644-P AirLINE Type 804 Type 8030 Control valve with TopControl Continuous SideControl Valve island with electronic I/O Flow sensor only with 803 remote Flow sensor only with 803 remote This intelligent controller with display is designed for use in clear, neutral or aggressive liquids and specially to switch a valve and to establish a monitoring system or an On/Off control loop. The switching points can be programmed with the 3-key keypad under the display or optionally, for the compact 803 only, from an external source over a 4-0 ma loop. The compact 803 is proposed with On/Off, or with external setpoints and process value s. The remote 803 has a transistor. The connection to the process in the piping is done with standard INLINE fittings. General data Compatibility Materials Housing, cover Front panel folio / Screws Cable plug, gland Materials wetted parts Fitting, sensor armature Paddle-wheel Axis, bearings / Seal Wall-mounted holder Display With fittings S030 (see corresp. datasheet) PC, +0% glass fibre Polyester / Stainless steel PA Brass, stainless steel, PVC, PP or PVDF PVDF Ceramics / FKM (EPDM option) PVC 8-digit LCD Electrical connections Cable plug: EN 730-803 Multipin: M, -pin or 8-pin Voltage supply cable 0. mm max. cross section; max. 00 m length, shielded Remote sensor connection 0. mm max. cross section; max. m length, shielded Complete device data (fitting + electronic module) Pipe diameter DN 06 to 6 Measuring range 0.3 to 0 m/s Medium temperature 0 up to C (with PVC fitting) / 0 up to 80 C (with PP fitting) - up to 00 C (with St. st., brass or PVDF fitting) Fluid pressure max. Viscosity Accuracy ) Teach-In Standard K-factor Programming mode Linearity ) Repeatability ) PN0 (with plastic fitting) - PN6 (with metal fitting) 300 cst. max. ± % of F.S.* (at 0 m/s) ± (% of F.S.* + 3% o. Reading) Threshold, window or hysteresis ± 0.% of F.S.* (at 0 m/s) 0.4% of Reading * F.S. = Full scale (0 m/s) ) Under reference conditions i.e. measuring fluid = water, ambient and water temperature = 0 C, applying the minimum inlet and outlet pipe straights, matched inside pipe dimensions. www.burkert.com p. /6

Electrical data Power supply Compact version Wall-mounted version Current consumption Compact version Wall-mounted version Input External setpoint Frequency (remote version) Outputs Transistor (programmable) Relay (programmable) (compact version) Process value (option) (compact version) Reversed polarity of DC Environment Ambient temperature Relative humidity filtered and regulated -30 V DC Depends on the remote sensor: 804: 8-30 V DC 800, 8030: -30 V DC other: min. V DC, max. 30 V DC 80 ma (no load) ma (no load) + remote sensor current consumption 4-0 ma, galvanic insulation max. input impedance: Ω Pulse signal: to 400 Hz input impedance: 0 kω NPN and PNP, open collector, -30 V DC, max. 700 ma, 0 to 300 Hz protect against short circuit. 3A/ V AC or 3A/30 V DC. 3A/48 V AC or 3A/30 V DC ). 4-0 ma, galvanic insulation Loop resistance: 000 Ω at 30 V DC, 800 Ω at 4 V DC, 0 Ω at 8 V DC Protected Standards and approvals Protection class IP6 Standard EMC Security Vibration Shock 0 up to + 60 C (operating and storage) 80%, non condensated EN 60006-, 60006-3 EN 600- EN 60068--6 EN 60068--7 ) Valid for: external setpoint input, process value Accuracy diagram Max. error [%] 0 6 8 4-4 -8 - -6-0 % o.f.s. + 3% o. R. % o.f.s. o. F.S. = of Full Scale o. R. = of Reading 3 4 6 7 8 9 0 Bürkert typical curve with standard K factor with Teach-In Flow velocity [m/s] Design and principle of operation Electronic SE3 Fitting S030 Electronic SE3 Wall-mounted holder The compact flow controller 803 is built up with an electronic module SE3 associated to a fitting S030 with integrated measurement paddle-wheel. The signal is provided via cable plug according to EN 730-803 and/or a M multipin connector. The wall-mounted flow controller 803 is built up with an electronic module SE3 associated to a wall-mounted holder. The signal is provided via two M multipin connector. When liquid flows through the pipe, the 4 magnets, inserted in the paddle-wheel set in rotation, produce a measuring signal in the transducer. The frequency is proportional to the flow velocity of the fluid. A conversion coefficient (K factor, available in the instruction manual of the fitting), specific to each pipe (size and material) enables the conversion of this frequency into flow rate. Operation and display The device can be calibrated by means of the K-factor, or via the Teach-In function. Customized adjustments, such as engineering units,, filter, bargraph are carried out on site. The operation is specified according to three levels: Indication in operating mode / Display - measured flow - high threshold value - low threshold value Parameter definition - engineering units (International measuring units) - K-factor / Teach-In function - selection of switching mode (window, hysteresis) (see main features) - selection of threshold value (see main features) - delay - filter - 0-segment bargraph (select min. and max. value) Test - switching threshold test with flow simulation (dry-run test operation) To scroll-up the menu or increase a value To scroll-down the menu or select a digit to be modified Large digital display with 8 characters (4 digital characters and 4 alphanumeric characters) Bargraph Confirm input and menu points Status of the switching (red LED) p. /6

Main features 803 with external setpoint option. The switching points are automatically adjusted by the 4-0 ma input signal originating from a PLC. - Power supplied by the PLC - On/Off relay 803 with standard On/Off - switching modes for the, either hysteresis or window, inverted or not Hysteresis mode Window mode Hysteresis, inverted Hysteresis, not inverted Window, inverted Window, not inverted - Programmable delay before switching - Possible s depending on the version: relay, transistor NPN, transistor PNP, frequency 803 with process value option. This version delivers an electric signal whose value is the image of the measured quantity. - On/Off relay - 4-0 ma - external setpoint (4-0 ma input) Installation The 803 flow controller can easily be installed into any Bürkert INLINE fitting system Type S030 by means of a Quarter-Turn. Minimum straight upstream and downstream distances must be observed. According to the pipe s design, necessary distances can be bigger or use a flow conditioner to obtain the best accuracy. For more information, please refer to EN ISO 67-. EN ISO 67- prescribes the straight inlet and outlet distances that must be complied with when installing fittings in pipe lines in order to achieve calm flow conditions. The most important layouts that could lead to turbulence in the flow are shown below, together with the associated prescribed minimum inlet and outlet distances. These ensure calm, problem-free measurement conditions at the measurement point. DN = orifice Fluid direction --> Regulating valve x DN x DN x 90 elbow joint x DN x DN Extension 8 x DN x DN x 90 elbow joint 3 dimensional 40 x DN x DN 90 elbow joint or T-piece 0 x DN x DN Reduction x DN x DN The flow controller can be installed into either horizontal or vertical pipes. Pressure and temperature ratings must be respected according to the selected fitting material. The suitable pipe size is selected using the diagram Flow / Velocity / DN. The controller is not designed for gas flow control. p. 3/6

Pressure / temperature chart Dimensions P (bar) 6 A Metal 4 3 0 9 8 7 PVDF PVC + PP PVDF (PN0) 6 4 3 PVC (PN0) PP (PN0) 0-30 -0 +0 +30 + +70 +90 T C +0 803 compact 94 FLOW SWITCH 67. Application range for complete device (fitting + controller) 30 Selection of fitting / pipe size 4. Example: - Specification of nominal flow: 0 m 3 /h - Ideal flow velocity:...3 m/s - For these specifications, the diagram indicates a pipe size of DN40 [or DN for (*) mentioned fittings] Flow rate gpm 000 0 00 00 0 0 0. 0. 0. 0.0 l/min 3000 000 000 0 00 00 0 0 0. 0. m 3 /h 00 00 0 0 0. 0. 0. 0.0 0.0 0.0 0. 0.3 0. 3 0 DN 6 DN (DN6)* DN 40 (DN)* DN 3 (DN40)* DN (DN3)* DN 0 (DN)* DN (DN0)* DN 08 DN 06 0.3 0. 3 0 30 fps Flow velocity * For weld ends fittings SMS3008 or BS48/ASME BPE, or Tri-Clamp fittings SMS307/ISO8 or BS48/ASME BPE. Tri-Clamp is a registered Trademark of Alfa Laval Inc. m/s H 803 wall-mounted 80 3. 4. DN [mm] H [mm] 06 79. 08 79. 84. 0 8.0 8. 3 8.8 40 89.6 9.7 6 9.7 6 p. 4/6

Ordering chart for Controller Type 803 A compact flow controller Type 803 consists of: - a compact electronic module SE3 - an INLINE fitting S030 (DN 06 - DN 6) (Refer to corresponding datasheet - has to be ordered separately) Voltage supply Input Output Electrical connection Item no. -30 V DC --- NPN Cable plug EN 730-803* 436 474 PNP Cable plug EN 730-803* 434 87 NPN and PNP -pin M plug 436 473 Relay -pin M plug and cable plug EN 730-803* 436 47 4-0 ma ) 4-0 ma ) +Relay 8-pin M plug and cable plug EN 730-803* 444 699 ) External setpoint ) Process value * Europe / Asia (G / Rc): M6 x. mm cable plug USA / CDN (NPT): NPT / cable plug A wall-mounted flow controller Type 803 consists of: - a wall-mounted electronic module SE3 - a flow sensor Type 800, 8030, 8030-HT, 804 or 8070 - frequency with pulse signal (Refer to corresponding datasheet - has to be ordered separately) Ordering chart for accessories (to be ordered separately) Description Item no. Voltage supply Input Output Electrical connection Item no. -30 V DC frequency NPN and PNP -pin M male and 4-pin M female 448 86 4-pin M female cable connector with plastic threaded locking ring, for remote version 448 86 4-pin M female connector moulded on cable ( m, shielded), for remote version 448 87 -pin M female cable connector with plastic threaded locking ring 97 6 -pin M female connector moulded on cable ( m, shielded) 438 680 8-pin M female cable connector with plastic threaded locking ring 444 799 8-pin M female connector moulded on cable ( m, shielded) 444 800 Cable plug EN 730-803 with cable gland (Type 8) 438 8 Cable plug EN 730-803 with NPT/ reduction without cable gland (Type 9) 6 673 p. /6

Interconnection possibilities with other Bürkert products Compact flow controller Type 7 (067) Globe valve with control head Type 8 - Solenoid valve Type 6 - Solenoid valve PLC 4-0 ma Transistor Relay Input 4-0 ma (Ext. setpoint) Type 803 - Compact flow controller Wall-mounted flow controller Type 8070 Low flow measurement Type 800 - For pipes DN 06 to 400 Type 804 - Flow measurement of contamined fluids for pipes DN 06 to 400 Type 8030 - For pipes DN 06 to 6 Frequency input Type 6 - Solenoid valve Type 803 - Wall-mounted flow controller Transistor To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. We reserve the right to make technical changes without notice. 070/7_EU-en_008978 p. 6/6