TS1 SMARTBOB REMOTE UNIT. INSTALLATION and OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Similar documents
TABLE OF CONTENTS SPECIFICATIONS...3 SAFETY SUMMARY...4 INTRODUCTION...5, 6 INSTALLATION...7, 8, 9, 10 TESTING THE REMOTE OPERATION AIR PURGE...

ASG-2000 SiloGauge Remote Unit

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

BMRX Series Rotary Level Indicator

PRO REMOTE Series CAPACITANCE PROBE

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

PRO REMOTE 25 LV CAPACITANCE PROBE

CVR-625. Compact Vibrating Rod Instruction Manual

BMRX Series ROTARY LEVEL CONTROL

SmartBob II SBR.1 A M1 H X X XX. Base. Mounting Plate. Cable. Heater. Probe

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

the weight-and-cable assembly.) The standard cast-aluminum weight (Figure 1a) is suited to about 80 to 90 percent of applications; other specialized w

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

IOM. LP-100 & LP-200 Pulse Point TM Installation & Operation Manual

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

CTFRP Series Power Supplies

BinMaster Price Book

LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS

FHC-1D user manual. Features

PCS GEAR SELECT MODULE USER GUIDE v4.0

ROTARY Point Level Measurement for Inventory Control

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

Diaphragm Switch BM65

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

Tunnel Control Stations Installation Instructions

Sentinel Field Satellite Controller

Super-Safe-Plus Roto-Bin-Dicator

MODEL D-SBG Single Arm Barrier Gate Operator

A419ABG-3C Electronic Temperature Control

TRAILER AUXILIARY POWER SYSTEM (TAPS) INSTALLATION GUIDE V1.10

MODEL MODEL S

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

Installation Instructions

ADJ200 Smart Skimmer and 2500ES Electronic Controller Single Skimmer Operations Manual

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Installation Instructions

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

ELECTRO-MECH SCOREBOARD CO.

Patient Care Facility

U S A INSTALLATION GUIDE EP400 / E8-B

BinMaster Price Book

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

series USER MANUAL

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

LifeGuardLift. LifeGuard Power Lift Model #100287A OWNERS MANUAL. Rev: 2/14/11

8460SRC Replacement Chassis for Scully ST-6 and Biclops Monitors

LNII Series Motor and Drives

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

MODEL D-WBG Wishbone Arm Barrier Gate Operator

Patient Care Facility Multiple Room Configuration Style 3 W/ Ver 4.41 pcb & Pulse Relay pcb(s)

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

MPT-200A SPECIFICATIONS AND OPERATING INSTRUCTIONS

VOC Duct and Rough Service Sensor

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

Feed Scale Installation & Operator s Instruction Manual

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

User s Guide. EZ-Bar Livestock Scale WEIGH BARS AND DIGITAL INDICATOR. WB-40 Weigh Bars TS-700 WB Digital Indicator. Guide version 1.

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

ADJ1015L High Performance Smart Skimmer with Extended Travel and 2500ES Electronic Controller Single Skimmer Operations Manual

Patient Care Facility

RAPID Environment Control INSTALLATION GUIDE. Ver 99C. RAPID Environment Control. Creep

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

ASSEMBLING THE 15 INCH FLUSH MOUNT TOUCH SCREEN DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN

SRC. An Outdoor Reset Control for Sub-Atmosphere Steam Systems OUTDOOR TEMPERATURE

POWER GEAR SLIDE-OUT MANUAL

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

12 STATION MANUAL CONTROLLER INSTALLATION AND OPERATING GUIDE MODEL HRM-12

PROCAP Capacitance Level Sensors

TC26-B Vehicle Sensor

CDS-JOHN BLUE COMPANY

4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

! "! User Manual Myers Power Products CTEP/G Manual 6/2009

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

ALL700RM-230V INSTALLATION INSTRUCTIONS

PT-500 Analog Output Series User Manual

BIM-17-2 Bus Interface Module for compass and outside temperature

Installation Instructions for Eaton Surge Protective

Installation and Maintenance Manual

30A SMART ENERGY MANAGEMENT SYSTEM TM

450250/ ROOSTER WINCH Installation Manual

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

Long-Range Barrier Sensors

SE-400 MANUAL GROUND-FAULT-RELAY TEST UNIT

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

SOFT TOUCH FOR PNEUMATIC RIVETERS

Transcription:

TS1 SMARTBOB REMOTE UNIT INSTALLATION and OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 No. 98th Street P.O. Box 29709 Lincoln, NE 68507 Lincoln, NE 68529 (402) 434-9102 Fax (402) 434-9133 www.binmaster.com e-mail: info@binmaster.com 925-0259 Rev B 1

TABLE OF CONTENTS SPECIFICATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 1.0 INTRODUCTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 2.0 INSTALLATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 2.1 LOCATION AND MOUNTING - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 2.2 POWER WIRING - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 2.3 RS-485 NETWORK WIRING - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 2.4 RS-485 NETWORK BIASING AND TERMINATION - - - - - - - - - - - - - - - - - - - - - - - - 6 2.5 WIRELESS MODEM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7 2.6 SETTING THE ADDRESS SWITCH - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8 2.7 EXTERNAL OVERRIDE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -10 2.8 PROTO JUMPER SETTING - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -10 3.0 TESTING THE REMOTE OPERATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11 3.1 TS1 MANUAL CYCLE AND RETRACT SWITCHES - - - - - - - - - - - - - - - - - - - - - - - -11 3.2 LED INDICATORS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -11 3.3 TROUBLESHOOTING 12 4.0 WARRANTY AND CUSTOMER SERVICE - - - - - - - - - - - - - - - - - - - - - - - - - - - 12 4.1 LIMITED WARRANTY - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -12 4.2 CUSTOMER SERVICE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -12 CABLE REPLACEMENT INSTRUCTIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13 LIMITING THE NYLON CABLE LENGTH - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14 BOB ASSEMBLY INSTRUCTIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15 SMARTBOB REMOTE MOUNTING TEMPLATE- - - - - - - - - - - - - - - - - - - - - - - - - - - 16 925-0259 Rev B 2

SMARTBOB TS1 SPECIFICATIONS Power Requirements: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 115 VAC 60 Hz (230 VAC Models are available) Power Consumption: - - - - - - - - - - - - - - - - - - - - - 21 VA Continuous 37 VA Intermittent Current Draw (RMS): - - - - - - - - - - - @115VAC: 0.18 A Continuous 0.32 A Intermittent @230VAC: 0.09 A Continuous 0.16 A Intermittent Temperature: - - - - - - - - - - - - - - - - - - 32 F to +140 F (0 C to +60 C) without heater 20 F to +140 F ( 28 C to +60 C) with optional heater Measurement Range: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -30 Feet Maximum Accuracy: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2% or 7 inches Resolution: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.1 ft (0.03m) Communication: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - RS 485 Half Duplex Wiring Distance: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4000 ft (1220m) (wireless option available) Enclosure: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Type 4X, 5, 12 Conduit Entry: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Two 3/4 inch KO s Weight: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10 lbs. Width: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11 inches Height: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -13 inches Depth: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -9 inches Cable: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Braided Nylon 90 LB Tensile Strength 925-0259 Rev B 3

1.0 INTRODUCTION The BinMaster SmartBob TS1 ia a remote on demand level measurement sensing unit. It is designed to communicate with a personal computer running BinMaster e-bob or IMS software, or a Bin Master SBC, SBC-A, or RSU control unit. Communication can be either over a hard wired RS-485 network or wireless using an optional built-in wireless modem. A single TS1 with a wireless modem can be hardwired to a cluster of other TS1 units to activate simple and economical installation configurations. In operation, the TS1 lowers a weighted bob to the surface of material, measuring the distance and reporting the result. A micro controller counts pulses from an optical encoder to determine this distance. Slack in the cable when the bob touches the material causes the unit to reverse and retract the bob. The retract distance is also measured for diagnostic purposes. Figures 4a through 4c illustrate a few possible system configurations for both hard wired and wireless installations. Many other configurations to fit specific needs are possible. 2.0 INSTALLATION 2.1 LOCATION AND MOUNTING The TS1 remote unit comes with one of several mounting options. The appropriate mounting option should be specified at the time of ordering. When mounting the TS1 to the top of the vessel, it is important that the unit is perpendicular so that in operation the cable does not rub on anything. The location of the TS1 on the vessel roof should be such that it will give a some what average level of the material. For the case of a round vessel, center filled with dry material, the mounting position which will give a mathematical average of the material level is 1/3 of the vessel radius from the outer edge. This is true mathematically for any angle of repose. FIGURE 1 1/3 R SmartBob TS1 Remote Unit Storage Vessel Material Fill R 925-0259 Rev B 4

2.2 POWER WIRING All wiring should be installed according to local and/or national codes. Refer to Figure 2 for the connection of the power wiring. The AC input power connects to the 2 pole terminal block. The neutral wire should be connected to the terminal on the right and the LINE conductor connected to the terminal on the left. The terminal on the left wires through the fuse to the transformer. A green ground screw is provided in the SmartBob TS1 for electrically grounding the unit. A good Electrical ground must be connected to the TS1 for safety and to bleed off any static electrical charges that might built up in the TS1. It is recommended that both the power and the RS-485 communication cable be ran in metal conduit. FIGURE 2 10 VAC to PC Board 10 VAC to PC Board 10 VAC to PC Board LINE NEUTRAL GROUND 2.3 RS-485 NETWORK WIRING RS-485 network cable consists of a twisted pair of wires with an outer shield such as Belden 9463 or similar. The cable is run from TS1 to TS1 with each unit connected in a daisy chain fashion with no branch or stub runs. Polarity of the twisted pair must be maintained throughout the entire network. The terminals for the RS-485 connection on the TS1 circuit board are labeled with polarity marks to help prevent cross wiring. A terminal connection is also provided for the outer shield of the cable. 925-0259 Rev B 5

NOTE: Where moisture may be a problem, use conduit sealing compound to prevent moisture from entering the TS1 through electrical conduits. FIGURE 3 RS 485 WIRING FROM CONSOLE. 485 INTERFACE, or PREVIOUS TS1 or SBRII RS 485 cable BELDEN 9463 or equiv. RS 485 WIRING TO THE NEXT TS1 or SBRII THE RS 485 WIRING MUST BE IN A DAISY CHAIN WIRING SCHEME TO THE PC BOARD AT EACH UNIT. THE TERM SWITCH AT EACH END OF THE THE RS 485 WIRING DAISY CHAIN SHOULD BE IN THE ON POSITION. ALL TERM SWITCHES IN BETWEEN MUST BE IN THE OFF POSITION. 2.4 RS-485 NETWORK BIASING AND TERMINATION A proper installation of an RS-485 network will only have a resistive termination at each end of the cable run. Therefore, a cable from the computer interface will be terminated at the interface unit and at the last TS1 on the network. The BinMaster RS 232 to 485 interface unit will have its internal NTR jumper ON and the last TS1 on the network will have its TERM switch ON. All others should be OFF. The RS-232 to 485 interface provides network bias and all TS1 units hardwired to it should have their BIAS jumpers OFF. For a TS1 with a wireless modem which is driving a network of other TS1 or SmartBob SBRXII units, the TS1 with the wireless modem should have its BIAS jumpers ON and its TERM switch ON. All other TS1 units must have their BIAS jumpers OFF and except for the very last unit on the network must have their TERM switches (in TS1) or NTR switches (in SBRXII) OFF. The very last unit will have its TERM switch (NTR in SBRXII) ON and its BIAS jumpers OFF. Note: The TERM switch in the TS1 units performs the same function as the NTR switch in the RS 232 to 485 interfaces, RSU or SBC consoles, or SBRXII Remote units. 925-0259 Rev B 6

FIGURE 4a -- WIRED RS 485 FROM COMPUTER TO TS1 UNITS RS 485 CONVERTER FIGURE 4b -- WIRELESS FROM COMPUTER TO ONE TS1 WITH A RADIO MODULE, WIRED RS 485 TO OTHER TS1 s WITHOUT RADIO MODULES TS1 with RADIO MODULE TS1 without RADIO MODULE TS1 without RADIO MODULE NOTE: There can be only one TS1 unit having a wireless modem connected to each wired RS-485 network. Do not connect multiple TS1 units with wireless modems to the same RS-485 network. FIGURE 4c -- WIRELESS FROM COMPUTER TO ALL TS1 s WITH RADIO MODULES ALL TS1 UNITS HAVE RADIO MODULES 2.5 WIRELESS MODEM The optional wireless modem allows units to communicate without having interconnecting wires. A system may consist of all TS1 units having wireless modems or just one TS1 unit with a wireless modem and other TS1 units without wireless modems hard wired to it with RS-485 cable. In such a case where one TS1 with a wireless modem drives a hardwired RS-485 network, the TS1 with the wireless modem must have both of its BIAS jumpers placed in the ON position and its TERM switch in the ON position. All other units on the network should have their BIAS jumpers in the OFF position. The last unit on the RS-485 network should have its TERM switch ON and all other units, except the one with the wireless modem, should have their TERM switch OFF. 925-0259 Rev B 7

2.6 SETTING THE ADDRESS SWITCH Each TS1 has an ADDRESS switch located on its circuit board. An address which corresponds to that in the computer controlling software or other controlling device must be set on this switch. The address set by this switch is in binary and the value of each switch lever is printed on the TS1 circuit board above the switch. The Binary value of each lever in the up ON position are added together to give the address number. Consult the following chart to assist in determining the switch settings for any desired address number. Note: The RSU control unit only operates using address 1. It is intended to function with a single TS1 unit on an independent RS-485 cable. The address of that TS1 must be set to 1. 925-0259 Rev B 8

BIN ADDRESS DIP SWITCHES DIP SWITCH SETTING DIP SWITCH SETTING BIN ADDRESS BIN ADDRESS 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 ON OFF OFF OFF OFF OFF OFF OFF 66 OFF ON OFF OFF OFF OFF ON OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 67 ON ON OFF OFF OFF OFF ON OFF 3 ON ON OFF OFF OFF OFF OFF OFF 68 OFF OFF ON OFF OFF OFF ON OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 69 ON OFF ON OFF OFF OFF ON OFF 5 ON OFF ON OFF OFF OFF OFF OFF 70 OFF ON ON OFF OFF OFF ON OFF 6 OFF ON ON OFF OFF OFF OFF OFF 71 ON ON ON OFF OFF OFF ON OFF 7 ON ON ON OFF OFF OFF OFF OFF 72 OFF OFF OFF ON OFF OFF ON OFF 8 OFF OFF OFF ON OFF OFF OFF OFF 73 ON OFF OFF ON OFF OFF ON OFF 9 ON 0FF OFF ON OFF OFF OFF OFF 74 OFF ON OFF ON OFF OFF ON OFF 10 OFF ON OFF ON OFF OFF OFF OFF 75 ON ON OFF ON OFF OFF ON OFF 11 ON ON OFF ON OFF OFF OFF OFF 76 OFF OFF ON ON OFF OFF ON OFF 12 OFF OFF ON ON OFF OFF OFF OFF 77 ON OFF ON ON OFF OFF ON OFF 13 ON OFF ON ON OFF OFF OFF OFF 78 OFF ON ON ON OFF OFF ON OFF 14 OFF ON ON ON OFF OFF OFF OFF 79 ON ON ON ON OFF OFF ON OFF 15 ON ON ON ON OFF OFF OFF OFF 80 OFF OFF OFF OFF ON OFF ON OFF 16 OFF OFF OFF OFF ON OFF OFF OFF 81 ON OFF OFF OFF ON OFF ON OFF 17 ON OFF OFF OFF ON OFF OFF OFF 82 OFF ON OFF OFF ON OFF ON OFF 18 OFF ON OFF OFF ON OFF OFF OFF 83 ON ON OFF OFF ON OFF ON OFF 19 ON ON OFF OFF ON OFF OFF OFF 84 OFF OFF ON OFF ON OFF ON OFF 20 OFF OFF ON OFF ON OFF OFF OFF 85 ON OFF ON OFF ON OFF ON OFF 21 ON OFF ON OFF ON OFF OFF OFF 86 OFF ON ON OFF ON OFF ON OFF 22 OFF ON ON OFF ON OFF OFF OFF 87 ON ON ON OFF ON OFF ON OFF 23 ON ON ON OFF ON OFF OFF OFF 88 OFF OFF OFF ON ON OFF ON OFF 24 OFF OFF OFF ON ON OFF OFF OFF 89 ON OFF OFF ON ON OFF ON OFF 25 ON OFF OFF ON ON OFF OFF OFF 90 OFF ON OFF ON ON OFF ON OFF 26 OFF ON OFF ON ON OFF OFF OFF 91 ON ON OFF ON ON OFF ON OFF 27 ON ON OFF ON ON OFF OFF OFF 92 OFF OFF ON ON ON OFF ON OFF 28 OFF OFF ON ON ON OFF OFF OFF 93 ON OFF ON ON ON OFF ON OFF 29 ON OFF ON ON ON OFF OFF OFF 94 OFF ON ON ON ON OFF ON OFF 30 OFF ON ON ON ON OFF OFF OFF 95 ON ON ON ON ON OFF ON OFF 31 ON ON ON ON ON OFF OFF OFF 96 OFF OFF OFF OFF OFF ON ON OFF 32 OFF OFF OFF OFF OFF ON OFF OFF 97 ON OFF OFF OFF OFF ON ON OFF 33 ON OFF OFF OFF OFF ON OFF OFF 98 OFF ON OFF OFF OFF ON ON OFF 34 OFF ON OFF OFF OFF ON OFF OFF 99 ON ON OFF OFF OFF ON ON OFF 35 ON ON OFF OFF OFF ON OFF OFF 100 OFF OFF ON OFF OFF ON ON OFF 36 OFF OFF ON OFF OFF ON OFF OFF 101 ON OFF ON OFF OFF ON ON OFF 37 ON OFF ON OFF OFF ON OFF OFF 102 OFF ON ON OFF OFF ON ON OFF 38 OFF ON ON OFF OFF ON OFF OFF 103 ON ON ON OFF OFF ON ON OFF 39 ON ON ON OFF OFF ON OFF OFF 104 OFF OFF OFF ON OFF ON ON OFF 40 OFF OFF OFF ON OFF ON OFF OFF 105 ON OFF OFF ON OFF ON ON OFF 41 ON OFF OFF ON OFF ON OFF OFF 106 OFF ON OFF ON OFF ON ON OFF 42 OFF ON OFF ON OFF ON OFF OFF 107 ON ON OFF ON OFF ON ON OFF 43 ON ON OFF ON OFF ON OFF OFF 108 OFF OFF ON ON OFF ON ON OFF 44 OFF OFF ON ON OFF ON OFF OFF 109 ON OFF ON ON OFF ON ON OFF 45 ON OFF ON ON OFF ON OFF OFF 110 OFF ON ON ON OFF ON ON OFF 46 OFF ON ON ON OFF ON OFF OFF 111 ON ON ON ON OFF ON ON OFF 47 ON ON ON ON OFF ON OFF OFF 112 OFF OFF OFF OFF ON ON ON OFF 48 OFF OFF OFF OFF ON ON OFF OFF 113 ON OFF OFF OFF ON ON ON OFF 49 ON OFF OFF OFF ON ON OFF OFF 114 OFF ON OFF OFF ON ON ON OFF 50 OFF ON OFF OFF ON ON OFF OFF 115 ON ON OFF OFF ON ON ON OFF 51 ON ON OFF OFF ON ON OFF OFF 116 OFF OFF ON OFF ON ON ON OFF 52 OFF OFF ON OFF ON ON OFF OFF 117 ON OFF ON OFF ON ON ON OFF 53 ON OFF ON OFF ON ON OFF OFF 118 OFF ON ON OFF ON ON ON OFF 54 OFF ON ON OFF ON ON OFF OFF 119 ON ON ON OFF ON ON ON OFF 55 ON ON ON OFF ON ON OFF OFF 120 OFF OFF OFF ON ON ON ON OFF 56 OFF OFF OFF ON ON ON OFF OFF 121 ON OFF OFF ON ON ON ON OFF 57 ON OFF OFF ON ON ON OFF OFF 122 OFF ON OFF ON ON ON ON OFF 58 OFF ON OFF ON ON ON OFF OFF 123 ON ON OFF ON ON ON ON OFF 59 ON ON OFF ON ON ON OFF OFF 124 OFF OFF ON ON ON ON ON OFF 60 OFF OFF ON ON ON ON OFF OFF 125 ON OFF ON ON ON ON ON OFF 61 ON OFF ON ON ON ON OFF OFF 126 OFF ON ON ON ON ON ON OFF 62 OFF ON ON ON ON ON OFF OFF 127 ON ON ON ON ON ON ON OFF 63 ON ON ON ON ON ON OFF OFF 128 OFF OFF OFF OFF OFF OFF OFF ON 64 OFF OFF OFF OFF OFF OFF ON OFF 129 ON OFF OFF OFF OFF OFF OFF ON 65 ON OFF OFF OFF OFF OFF ON OFF 130 OFF ON OFF OFF OFF OFF OFF ON 925-0259 Rev B 9

2.7 EXTERNAL OVERRIDE This feature can be used to prohibit measurements during a vessel filling cycle. The IMS software will notify the user that a measurement cannot be taken while a filling operation is in progress. Located on the SmartBob circuit board (just below the RS-485 terminals), is the terminal block labeled OVERRIDE. A connection must exist across these terminals for normal operation of the remote unit, see Figure 6. A contact on an external relay can be used to disable the remote unit during a fill cycle to prevent burying the Bob. The use of this feature is optional, if not used, leave the factory installed jumper in the terminal block. FIGURE 6 NC C External Relay OVERRIDE Located on PCB Coil 2.8 PROTO JUMPER SETTING The TS1 is capable of operating in two different modes as selected by the PROTO jumper located on the TS1 circuit board. The desired mode is dependent upon what type of controlling device the TS1 is operating with and is normally set at the factory in accordance with a particular customer order. PROTO A operates in a polling mode and PROTO B in a non-polling mode. The PROTO setting and corresponding controlling devices are listed below. PROTO A e-bob software SBC-A console QUCM MUCM PROTO B IMS software SBC console RSU console 925-0259 Rev B 10

3.0 TESTING THE REMOTE OPERATION 3.1 TS1 MANUAL CYCLE AND RETRACT SWITCHES The TS1 circuit board contains several push switches which allow certain manual operations of the unit. The function of each push button switch is described below. CYCLE RET HI RET LO FWD Momentarily pushing this button starts a measurement cycle. The bob will descend and retract as in normal operation. When this switch is pushed, the motor retracts the bob under HI torque. This switch may be used to help free a buried bob. Do not push this switch when the bob is seated at the top or the cable may pull down in its supply spool and become stuck. Use this switch to retract a free bob. As long as the switch is pushed the motor runs under low torque and allows the bob to be retracted and seated at the top without stressing the cable. This switch allows the motor to run forward and let out line to lower a bob It only runs while the switch is held in. 3.2 LED INDICATORS BUSY RPLY RX TX STATUS This LED indicates when data traffic is present on the RS-485 network. This LED indicates when that particular TS1 sends data out on the RS-485 network. If a wireless modem is installed, this LED indicates when data is received over the wireless. Lighting of this LED should be immediately followed by the lighting of the BUSY LED. This LED indicates when data is transmitted over the air from the wireless modem. This LED should light when ever any unit on the RS-485 network sends data. This LED turns on when the unit switches to low torque retract mode. This LED should light at the end of each retract cycle and on power up of the TS1. NOTE: On power up, the TS1 performs a low torque retract operation to insure that the bob is fully retracted following a power off period. 925-0259 Rev B 11

3.3 TROUBLESHOOTING If the remote fails to cycle, verify that the Input Power is present at the terminal block and that the POWER LED located on the circuit board (in lower right corner), is lit. This LED should be lit whenever the power is present at the board terminals. If the unit still does not operate, consult the factory at 800 278-4241. 4.0 WARRANTY AND CUSTOMER SERVICE 4.1 LIMITED WARRANTY The manufacturer warrants this equipment for one (1) year according to the following terms: 1.) This warranty extends to the original purchaser only and commences on the date of original purchase. The original purchaser must mail to the manufacturer the Warranty Registration card to confirm the equipment purchase. Failure to do so may void the warranty. 2.) The manufacturer will repair or replace any part of this equipment found to be defective, provided such part is delivered prepaid to the factory. Manufacturer s obligation is limited to the cost of material and labor to repair or replace and does not include transportation expenses. 3.) This warranty shall not apply to any product that has, in our judgement, been tampered with, altered, subject to misuse, neglect or accident. In addition, the warranty does not extend to repairs made necessary by normal wear. 4.) This warranty is in lieu of all other warranties, expressed or implied. 4.2 CUSTOMER SERVICE BinMaster offers a toll-free Customer Service phone number, 800 278-4241. You may call the Customer Service Department for technical and application assistance Monday through Friday from 8:00 AM to 5:00 PM Central Time. International customers call us at (402) 434-9102 or reach us via Fax at (402) 434-9133. E-mail questions to info@binmaster.com. 925-0259 Rev B 12

Cable Replacement Instructions Nylon Cable Supply Pulley Idler Pulley Timing Pulley Idler Pulley 1.) Remove the Bob and discard the old nylon cable. 2.) Tie a knot 18 from the end of the cable. This will keep from paying out all of the cable in the event the unit is lowered into a empty vessel. 3.) Thread the same end of the cable through the hole on the front of the supply pulley flange and tie a knot to secure the cable to the supply pulley. 4.) Located on the PC board is a button labled RET-LO. Pressing and holding the button will wind the cable onto the supply pulley. 5.) Thread the nylon cable through and around the idler pullies and the timing pulley as shown in the above illustration. 925-0259 Rev B 13

Limiting the Nylon Cable Length It is important to limit the length of the cable on the TS1 remote, so that the bob is not lowered into an airlock, screw conveyor or any other area that the Bob might become trapped in. The TS1 is shipped with 30 of cable unless otherwise specified. Disregard these instructions if the unit was ordered with the exact amount of cable necessary for your vessel. 1.) Remove the cable from the supply pulley by pressing the CYCLE button in the center of the PC board. Keeping the cable taunt, pull on the cable as the cable spools off the pulley. When the line is all payed out, the motor will reverse and try to rewind the cable. Hold the cable tight so it cannot rewind. The motor should now be shut off. 2.) From the throat of the TS1, measure the height of your vessel or the maximum distance you want the bob to travel. Cut the cable at this distance. 3.) Attach the cable to the bob as shown in the bob assembly instructions. 4.) Test the knot by pulling on the cable and bob. 5.) Rewind the cable onto the supply pulley or lower the cable and bob into the vessel. To rewind onto the supply pulley: Pull the cable taunt. Load the supply pulley by pressing (and hold) the RET-LO button located on the circuit board. Pressing this button will start the supply pulley turning in a clockwise direction, with the cable winding over the top. 6.) Continue installation of the unit on your vessel. 925-0259 Rev B 14

Bob Assembly Instructions (With Nylon Cable) Cap Teflon Ball Sleeve Pipe Fitting Rubber Ball O ring Washer Knot Washer Knot Digestible Bottle B7 This Bob is designed for granular material with a density from 20 lbs. per cubic foot and greater. The B7 Bob should be filled with a material that is compatible with the material that is stored in the storage bin. Total weight of the Bob when full should be 16 oz. The B7 is made from an engineering plastic which will not damage the material handling auger in the unlikely event that the Bob should become separated from the unit. Spherical Float B8 This Bob is a hollow 5 sphere made of stainless steel and is designed for bulk products with a density from 1.5 lbs. to 20 lbs. per cubic foot. This Bob may also be used in liquid applications. 925-0259 Rev B 15

SmartBob Remote Mounting Template 5/16 Diameter Through Hole 6 Holes Equally Spaced 4 1/4 Diameter Cutout 5 1/8 Diameter Bolt Hole Circle 925-0259 Rev B 16

SmartBob Remote Mounting Template 7.00 inch Bolt Circle 5/16 Diameter Through Hole 6 holes equally spaced on a 7.00 Bolt Circle 4 1/2 Diameter Cutout 7.00 Diameter Bolt Hole Circle template_7 inch