Portable HEPA System

Similar documents
Air Boss M-Series Media & Adsorption Air Cleaner

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

DESKTOP CONTAINMENT SYSTEM

MODEL SAFETY & INSTRUCTION MANUAL

MODEL MC1500 Installation and Operation Manual Important:

Installation & Service Manual for Portable Fume Collector. Model PFC-800

Affordable portable filtration unit

Portable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500 CFM (2550 M3H) For 2 arm configuration

Owner s manual for installation, usage and maintenance

WELDING FUME EXHAUSTERS & ARMS

quatroair.com AIR TECHNOLOGIES INC.

CA3000C & CA6000C Cartridge Air Cleaners

Owner s manual for installation, usage and maintenance

THE ENVIROMAC MOBILE AIR CLEANER ( ) OWNER S MANUAL

INSTALLATION GUIDE. Greentek. Residential use only MODEL HS 3.0

FA1 Series Air Filtration System. Operations Manual

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

OWNER S MANUAL. Installation and Service Manual

MODEL FA1 Mini Air Filtration System. Operations Manual

D-Series Blowers and Exhausters

SERIES 100 OWNER'S MANUAL. Installation, Operation & Maintenance TOUGH PORTABLES MODEL S130

MODEL MA4210 Installation and Operation Manual Important:

HEPA AIR FILTRATION SYSTEM

15000 TT Series Tube Type

MODEL FA5 Air Filtration System. Operations Manual

Indoor Air Quality Solutions for Machining Applications MistBuster source collection and MX-Series centralized filtration

PORTABLE WELDING FUME EXTRACTOR MODEL: PFE-230

Fume Extraction & Dust Collection

MC2500. Installation and Operation Manual

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

Fume extractor is warranted for two years, parts and labor.

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

MODEL SCA Installation and Operation Manual Important:

MAGNETOGRAPHIC PRINTER

Installation & Service Manual for Vertical Media (VM) Series Collectors

ENGINEERED FOR EXCEPTIONAL PERFORMANCE.

SPH General Manual 400 Series

200, 9200 & 9200-VIB SERIES

ENVIRO UNIT CES SERIES

Ductless Nanoparticle Containment Enclosures

AMAIRCARE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS. Rules for Safe Installation and Operation

MODEL GS1-100 Air Filtration System. Operations Manual

PORTABLE ELECTROSTATIC PRECIPITATOR: SMOG-HOG PCN

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

Powerful. Efficient. RED. Look to Micro Air Dust Collectors for clean air and cost-effective operation.

High Performance Ductless Balance Enclosures

User Manual. Model: FSL300 Dual Port Laser Fume Extractor

WSO Mist Collectors. cáäíê~íáçå=qéåüåçäçöó Ñçê=jáëí=`çääÉÅíáçå

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

Ventilated Balance Enclosures

User s Manual D-Series Blowers and Exhausters

Miracle State Of The Art Air Filtration System!

Installation & Service Manual for VM-10 Series Collectors. Models VM-10 VMH-10

KENYA MARINE AND FISHERIES RESEARCH INSTITUTE

A X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S

PHOENIX MINI-GUARDIAN

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

Owner s Manual Phoenix Guardian HEPA System

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

Why Fume Extraction? Lead-Free Solders Are The Worst

Protector Demonstration Hoods

6-54 HEPA Filter Assembly

OmniAire 2200 Operations and Maintenance Manual

TOTALINE ELECTRONIC AIR CLEANERS

HEPA-AIRE PORTABLE AIR SCRUBBER-PAS1800 INSTRUCTION MANUAL

Leading the way for clean air in the new millennium. S o u r c e C a p t u r e

LINCOLN ENVIRONMENTAL SYSTEMS

After installing the HEPA filters the discharge air should be monitored to ensure proper filtering efficiency. HEPA Filters

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

IMPORTANT SAFETY INSTRUCTIONS

DUST COLLECTORS. Stronger. Better. CLEANER.

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BTX-208. Fume Extraction System _B

AIR FILTRATION DEVICE

PHOENIX GUARDIAN H. E. P. A. SYSTEM

SERVICE INSTRUCTIONS,HOOVER - BAGLESS CLEANERS

Owner s Manual Phoenix Guardian HEPA System

Fume Extraction Planning Guide

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

INSTRUCTION MANUAL. Abatement Technologies, Inc./Remediation Products Division. Abatement Technologies, Inc. Georgia, USA

OmniAire Portable Air Cleaner OA1200PAC

Dust Collectors and Fume Exhausters

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

PRECISE. Glove Boxes

I-6500 Series. Industrial Applications. Operations & Maintenance Manual. Air Purifiers for. Manufactured. Serial number.

INSTALLATION / OPERATION / MAINTENANCE GUIDE

Specialists in HEPA Filtration and Negative Air Machines

Installation & Service Manual for Small Portable Cartridge Collector. Model SPC-1000

OmniAire 600N Operations and Maintenance Manual

Ductless Nanoparticle Containment Enclosures

OWNER S MANUAL MODEL FSHEPA375 WHOLE-HOUSE TRUE HEPA AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

PCR Laminar Flow Cabinets

Turning Air Into Solutions. PLUG FANS TYPE BCPL

Ducted HEPA filter units for highly sensitive areas

Loctite Air Filtration System Part Number EQUIPMENT. Operation Manual

Twin City Fan & Blower

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

THE MAGNUM SUCTION SYSTEM

Americraft is dedicated to assist you, our customer, in all aspects of your air moving requirements.

Transcription:

Operation and Maintenance Manual Portable HEPA System Series - PHS MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015

PORTABLE HEPA SYSTEM GENERAL INFORMATION SAFETY PRECAUTIONS: Keep all paper work relating to the PHS. Do not use the unit to extract easily flammable or explosive gases. Do not mix ferrous and non-ferrous materials within the collector. Protect the electrical power cord from damage Make sure the collector stands firmly and wheels are locked. Use only high grade filter replacements. Do not operate without filter inserts Protect the collector from dampness Unplug the collector before opening any electrical panels ASSEMBLY : Inspect all components for damage due to shipping. Portable cabinet ships completely assembly and ready for use Mount the arm to the top of the collector as shown in the arm instruction sheet supplied with the arm. After mounting arm and adjusting, the collector is ready for use Plug power cord into 120/1 outlet. MAINTENANCE: Except for occasional adjustment of the arm joints, the collector operates maintenance free. Only the filter inserts need to be changed. info@ 1

TECHNICAL DATA MOTOR: FAN: WEIGHT: CABINET: WHEELS: VOLTAGE: AMP DRAW: FILTERS: 1 1/2 HP 1 PHASE TEFC MOTOR 3450 RPM 780 CFM ACTUAL - BACKWARD INCLINE WHEEL CABINET, LESS ARM, IS 250 POUNDS 18 GAUGE STEEL WITH EPOXY POWDER COATING (4) CASTERS 5" DIAMETER WITH LOCKING FEATURE 115/120/1 PRE-WIRED POWER CORD START UP REQUIRES 13 AMPS - MINIMUM 20 AMP SERVICE STANDARD WITH : POLY PREFILTER & 99% HEPA CELL (24X24X12) OPTIONAL FILTERS: A. 24"X24"X9" HEPA 24"X24"X2" CARBON CELL UNIT STANDARD WITH FILTER MONITOR LIGHT info@ 2

The Monoxivent portable filter unit is used mainly for source capture and extraction of welding smoke. Different filter combinations can make the PHS a versatile unit. The contaminated air is drawn in at the top of the cabinet by an arm or central duct attached to the top. The particulate passes through a first stage poly pre-filter. Large particles are trapped in the pre-filter (1). The standard main filter (99% HEPA) then captures and removes even the smallest smoke particles (2). If desired, a third stage filter cell can be supplied (3). This third stage is usually a carbon cell. (3) Carbon Filter (1) Pre - Filter (2) HEPA Filter The poly pre-filter is supplied with a re-useable frame in which only the poly material is removed, thrown out and replaced. info@ 3

PORTABLE HEPA SYSTEM SERIES PHS The PHS unit is supplied with a poly pre-filter and a large HEPA main filter. Filter life cannot be determined since it is unknown as to how many hours a day the unit is used and also the type of application the unit is being used under. A portable unit is normally used for light usage and for maintenance purposes. Portables are not normally used for production type welding stations unless the best answer is a portable unit. Filter replacement should be a considering factor if used under a production/high welding usage application. The HEPA unit is supplied with a filter monitor light, which reads pressure difference between the clean side of the filter as to the dirty air entry side. The light can be sensitive to certain conditions so we suggest the following guideline for best results. A. Change the poly pre-filter weekly or more often based upon usage. The filter is low cost. The poly pre-filter's function is to capture larger particles. A simple holding up of the filter to a light will give a good indication of filter blockage. A clogged pre-filter can activate the filter monitor light, which should be used for the main filter reading. The poly pre-filters are packaged and sold in lots of 10. B. The HEPA main filter is a full 24"x24"x11 1/2". The HEPA filter change suggestion will be based on a couple of factors. The light is one factor but the true test of the HEPA filter is the suction of the fumes at the hood face. If the light comes on and the pre-filter is good, chances are the HEPA is getting loaded. The light is not a panic must change situation. It is an indicator of the filter getting full. Once the light has come on, the operator should now be aware of the suction at the hood face. When the hood can hardly pull any more smoke, then we have a full filter, which should then be changed. We suggest a simple and quick clean out of the machine upon each HEPA filter change. This is just good preventive maintenance. Poly pre-filter part number - 2424PP Pack of 10 HEPA main filter number - 2412-99-P Pack of 1 info@ 4

PHS - HEPA SYSTEM SIDE VIEW, EXPLODED 6" INLET HANDLE POLY PRE-FILTER 24x24x1 HEPA FILTER 24x24x12 (OPTIONAL - Carbon Filter, 24x24x2) 39" CONTROL PANEL POWER CORD DIRECT DRIVE PRESSURE BLOWER 1 HP, 120 V, 3450 RPM DISCHARGE SWIVEL CASTERS (2) LOCKING SWIVEL (2) SWIVEL CIRCUIT BOARD 27" info@ 5

PHS HEPA System Front View F E 39" F A H D B I C 26" A. B. C. D. E. F. G. H. I. Control Panel Counter Run Time Filter Monitor Light Blower on/off Rocker Switch Filter Access Door Access Door Hinges Wheels (4) Blower and Electrical Controls Access Panel Power Indicator Light info@ 6

info@ 7

Portable Fume Arm Assembly Information General Information for the Portable Fume Arm There will be some assembly required for the arm. Please check for all components before starting. 1. Check components for duct mount arms. 1. Arm with internal support structure 2. Base bracket mounted to arm 3. Hood mounted to arm 4. Hose Installed on arm 5. Black nylon swivel collar mounted on base 2. Slide hose back from base bracket. Be sure to see if red bolt is located in Hole 2. If red bolt is not in Hole 2 then remove bolt and rotate the base bracket 90-degrees so hole in bracket will align with Hole 2. Install red head bolt and snug. Arm is normally shipped with red head bolt in Hole 2 (see following page). 3. If mounting arm on Monoxivent portable unit the 8 holes in the black nylon swivel will align with the 8 holes in the top of the portable unit. Using hardware supplied with the arm, bolt the arm to the top of the unit. Tighten bolts evenly and bring to snug. Do not overtighten bolts. Be sure arm swivels easily 360-degrees. 4. The arm will need final adjustment/tuning for easiest movement and to stay in place upon positioning. You will find friction pads and adjustment pivot joints in four (4) places. 1. Pivot point at the bracket. 2. Pivot point in the center of the arm. 3&4. Pivot point at the hood location. Only put enough tension on these pivot joints to hold the arm in any position it is placed. The arm final adjustment is key to the arm being user friendly. Do not over tighten the pivot joint friction discs. Depending on arm usage and movement, occasional adjustments may be required. Based upon the arm s application, cleaning of the internal support structure may require scheduling. info@ 8

Portable Fume Arm Assembly of Hood to Hood Arm Bar on Arm Small Steel Washer Bolt Large Steel Washer Hood Arm Bar Small Steel Washer Nut info@ 9

Portable Fume Arm The drawing shows how the base bracket should be positioned for the arm to mount on a portable or other top mount surface. The arm for portable/top mount should have been supplied as shown. If it is not, then remove the red bolt head bolt and rotate base bracket 90-degrees and line up Hole 2 with hole in bracket and replace the red bolt head and snug. Pivot Direction of Arm Structure Internal Arm Support Structure Red Bolt Head location for Portable/ Top Mount Arm, mount in hole 2, as shown Friction Pivot Joint Bolts (8) Base Bracket Black Nylon Swivel Collar Portable, Table Top, Lid, Duct, or any other flat surface needing a source capture arm. info@ 10