GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc

Similar documents
GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc

(770) Turning Parts Changers Into TROUBLESHOOTERS!

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

Torque Converter, Transmission Pump, Screen And Filter

HYDRAULIC STEERING MANIFOLD HM260 TABLE OF CONTENTS. 1. GENERAL INFORMATION... p TECHNICAL SPECIFICATIONS... p. 01

Introduction. General Information. Systems Operation

Hydrostatic Drive. 1. Main Pump. Hydrostatic Drive

Module 5: Valves. CDX Diesel Hydraulics. Terms and Definitions. Categories of Valves. Types of Pressure Control Valves

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Section 7.1. Wheel Drive Circuit - General System

Troubleshooting Bosch Proportional Valves

Hand-operated Hydraulic Control Valve 4- way 2-position 4 Ports

Troubleshooting the Transmission Hydraulic System

OPERATION AND PARTS MANUAL

Pilot Oil Supply Circuit

Cartridge Valves Technical Information. Spreader Valves. Spreader Valves SCHEMATIC MODEL PRESSURE FLOW* WEIGHT SPR-2FFL12 SPR-2FFLC12 SPR-2FFLW86

Lesson 5: Directional Control Valves

Spreader Valves SPR-2FFL12, SPR-2FFLC12 & SPR-2FFLW86

SERIES Waterman* DESCRIPTION FLOW PRESSURE PAGE NO.

Appendix A. Standard Symbols for Hydraulic Components

Section 35 Chapter 2 HYDRAULIC SYSTEM HOW IT WORKS AND TROUBLESHOOTING NH

LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks:

Exercise 3-1. Basic Hydraulic Circuit EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Complete hydraulic circuit

BRAKE SYSTEM, HYDRAULICALLY ACTUATED - 631G TRACTOR Cat Tractors with standard shoe/drum brakes

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

ME 360 Test #3 Spring 08 5/5/08. Closed book, closed notes portion of test. Total of 25 out of 100 points for questions #1 to #6.

LogSplitterPlans.Com

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Implement Circuit

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

Solenoid valve. Solenoid Coil

3406E Truck Engine 5EK01821-UP(SEBP ) - Document Structure. Media Number -RENR Publication Date -01/02/2008 Date Updated -07/02/2008

Section 35 Chapter 9

Fluid Maintenance. The hydraulic oil performs four functions in the hydraulic system:

Exercise 3-1. Basic Hydraulic Circuit EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Complete hydraulic circuit

LECTURE 15 TO 17 DIRECTIONAL CONTROL VALVES FREQUENTLY ASKED QUESTIONS

Section 6.1. Implement Circuit - General System. General: Implement Control Valve:

3PC Directional Control Valves

Grout Pump Automatic & Manual Troubleshooting Gas Wiring Diagram

three different ways, so it is important to be aware of how flow is to be specified

Electropneumatics Basic Level Set of Overhead Transparencies TP 201

The Discussion of this exercise covers the following points:

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Eaton Directional Control Valves. h y d r a u l i c s. Models and 31930

MP18/SIC & SIO Stacking Valve System Technical Information Manual

Chapter 13: Application of Proportional Flow Control

OPERATION AND SERVICE MANUAL. McGILL UNIVERSITY PROJECT: MCS-3237 SUBJECT: HYDRAULIC POWER UNIT AND ROTARY ACTUATORS DECEMBER 2001

Basic Hydraulics. Module 2: Actuators and directional control valves. Curriculum Development Unit PREPARED BY. August 2013

Troubleshooting Guide for Slide-Out (S) Extending (Drifting) from Stowed Position

PNEUMATICS CONTENTS HST-TAMPER

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

CIRCLE SEAL CONTROLS

800SVRM-7 5/04 RATE-OF-FLOW CONTROL 800 SERIES CONTROL VALVES

MP18 Stacking Valve System Technical Information Manual

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

and RD5000 or by the Utility section in the Series 20 valves. 7. The internal pilot pressure is used to initiate the spool shift when a solenoid is en

HOW THE SPRAGUE PRODUCTS BOOSTERS WORK

200C II BRAKE SYSTEM

ASSIGNMENT Chapter 4 AIRCRAFT ELECTRICAL SYSTEMS

Pressure Control Valves

2. Hydraulic Valves, Actuators and Accessories. 24 Marks

FLUID POWER P&IDs. IDENTIFY the symbols used on engineering fluid power drawings for the following components:

CS-SCB Sander Control Block Manual

Chapter 6 Pneumatic Logic Sensors and Actuators

SV SOLENOID OPERATED

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

Catalog HY /US Flow Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE LPM/GPM BAR/PSI

CH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G

CLS100 Proportional Load Sensing Mobile Valve

DISCUSSION OF FUNDAMENTALS. A hydraulic system can be controlled either manually or automatically:

Servo and Proportional Valves

General Valve Assembly Information

OPERATION AND PARTS MANUAL

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

Service and Parts Manual. Minimum Filtration Required:

Introduction. Installation. Maintenance. Bill of Materials

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

OPERATION AND PARTS MANUAL

Commercial Products Hydraulics Hydrostatics Schematics and Test Equipment

36EFC. Series & EFC Valve Package

Hydraulic Master Cylinders

MPD Manifold 4-1/ psi with Integrated Control System

JIS symbols used in this catalog are old symbols following JISB0125-1: Refer to JISB0125-1: 2007 or JFPS2011: 2006 for new symbols.

CLS180 Proportional Load Sensing Mobile Valve

Tests & Adjustments - General Machine. General Safety Hydraulic Tank Turbo Boost Regulator

Air Driven Gas Boosters

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Solenoid valve VDHT standard BSP (British Standard Pipe)

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS

Eaton Heavy Duty Hydrostatic Transmissions

MPD Manifold 4-1/ psi with Integrated Control System

MPD Manifold 4 x psi with Integrated Control System and Coriolis Flowmeter

TABLE OF CONTENTS. 1. Before You Begin 3 Disclaimer 3 What Is Included 3 Optional Accessories 3 Unpacking Instructions 3 Claims 3 Contact Us 3

Hydrostatic Power Train

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

ISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description

TECHNICAL CHARACTERISTICS

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Job Sheet 5 Hydraulic Unit Circuit

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS

Transcription:

Hydraulic Consulting, Inc This special promotional CD is to demonstrate how your hydraulic troubleshooting manual can be ordered as an Adobe Acrobat ebook. It can be installed on any computer with the included Acrobat Reader and viewed wherever it will be the most helpful. Your ebook can be distributed across a Local Area Network, or copies can be made for distribution to all technical staff. Reader software is even included to download it to a PDA or Palmtop. Click the button to zoom in on portions of the document Click the button to search the entire document for any phrase or keyword Click the button to either show or hide the navigation pane. Click the button to print all or part of the document Call, Write or Fax GPM today for pricing and other details The document may be navigated either by clicking the Bookmarks tab to view by subject or click the Thumbnails tab to see miniature pictures of each page: GPM Hydraulic Consulting, Inc. P.O. Box 689 Social Circle, GA 30025 www.gpmhydraulic.com gpm@gpmhydraulic.com

Indexing Table Symbol Description M1 Gauge By moving the selector on the gauge to the M1 position, the pressure downstream of the fixed displacement pumps will be indicated. When the Index Table is operating, the maximum pressure will be limited by the No. 01.45.25 remote relief setting, 45 bar. When the broaching rams are operating, the maximum pressure will be limited by the No. 01.44.24 remote relief valve setting, 115 bar. When the Y01.36.20, Y01.37.20 and Y01.38.20 solenoids are de-energized, all pumps will return back to the tank at low pressure. A lower pressure will be indicated on the selector gauge at that time. M5 PF1 PF2 Gauge When the selector on the gauge is turned to the M5 position, the setting of the 04.10.09 pressure reducing valve will be read. The recommended setting of this valve is 40 bar. Pump This 18 GPM, fixed displacement, pump cartridge will supply a constant volume of oil to the Indexing Table actuators as well as the broaching rams. This pump cartridge is mounted in the same housing as the PF2 pump cartridge. PF1 is located on the back end of the pump assembly. Pump This 36.5 GPM, fixed displacement, pump cartridge will supply a constant volume of oil to the Indexing Table actuators as well as the broaching rams. This pump cartridge is located in the same housing as the PF1 pump cartridge. PF2 is located nearest the pump drive shaft. Troubleshooting Broaching Machine Hydraulics Page 1

PF3 PF4 Pump This 18 GPM, fixed displacement, pump cartridge will supply a constant volume of oil to the Indexing Table actuators as well as the broaching rams. This pump cartridge is mounted in the same housing as the PF4 pump cartridge. PF3 is located on the back end of the pump assembly. Pump This 36.5 GPM, fixed displacement, pump cartridge will supply a constant volume of oil to the Indexing Table actuators as well as the broaching rams. This pump cartridge is located in the same housing as the PF3 pump cartridge. PF4 is located nearest the pump drive shaft. SO1.18.13 Filter Assembly The filter assembly contains a three way manual valve, which selects one element or the other for filtering the PF2 pump volume. If the selected element becomes contaminated and the pressure drop Page 2 Troubleshooting Broaching Machine Hydraulics

across the element reaches the pressure switch s setting, a signal will be sent indicating the condition. This signal may give the operator an alarm or possibly shut the machine down depending on the electrical programming. The three way valve should be shifted at this time to select the clean element. If this is not done and the pressure drop across the element reaches the internal check valve s spring setting, the oil will then bypass to the system unfiltered. The filter condition should be checked or changed regularly to prevent contamination from entering the system. SO1.49.28 Pressure Switch The switch is used to electrically indicate an extreme high pressure condition. During normal operation, the maximum hydraulic pressure will be determined by the setting of the No. 01.44.24 remote relief valve, 115 bar. Once the setting of the switch is reached, an electrical signal will be sent indicating an over pressure condition. Depending upon the electrical programming, a shut down of the machine may occur. This particular switch is used as an over pressure device for the No. 1 broaching ram. SO1.52.28 Pressure Switch The switch is used to electrically indicate an extreme high pressure condition. During normal operation, the maximum hydraulic pressure will be determined by the setting of the No. 01.44.24 remote relief valve, 115 bar. Once the setting of the switch is reached, an electrical signal will be sent indicating an over pressure condition. Depending upon the electrical programming, a shut down of the Troubleshooting Broaching Machine Hydraulics Page 3

machine may occur. This particular switch is used as an over pressure device for the No. 2 broaching ram. SO4.06.06 Pressure Switch This switch will actuate when the Indexing Table fully lowers. An electrical signal will be sent once the pressure reaches a setting of 30 bar. This pressure switch is used to energize the Y04.09.08 B solenoid to return the table cylinders to the home position. Y01.36.20 Directional Valve When the PF1 pump volume is required to operate the Indexing Table and/or Broaching Rams, the valve solenoid is energized. This permits the No. 01.21.23 logic valve to operate as a high pressure relief. The pressure that the logic valve opens will be at either 45 bar (when Y01.43.20 is de-energized) or 115 bar (when the same solenoid is energized). The solenoid is energized when necessary to broach the part at the following speeds; 5, 15, 20, and 30 m/minute.. When the PF1 volume is not required to operate the Table or Broaching Rams, the valve solenoid is de-energized. This permits the No. 01.21.23 logic valve to open at low pressure (100 PSI or less). This permits the pump volume to return back to the tank at low pressure. Very little heat is created in this mode of operation. The valve is a two position, four way (with the A port plugged), single solenoid, spring return, directional valve. Y01.37.20 Directional Valve When the PF2 pump volume is required to operate the Indexing Table and/or Broaching Rams, the valve solenoid is energized. This permits the No. 01.23.23 logic valve to operate as a high pressure relief. The pressure that the logic valve opens will be at either 45 bar (when Y01.43.20 is de-energized) or 115 bar (when the same solenoid is energized). The solenoid is energized when necessary to broach the part at the following speeds; 10, 15, 25, and 30 m/minute. Page 4 Troubleshooting Broaching Machine Hydraulics

When the PF2 volume is not required to operate the Table or Broaching Rams, the valve solenoid is de-energized. This permits the No. 01.23.23 logic valve to open at low pressure (100 PSI or less). This permits the pump volume to return back to the tank at low pressure. Very little heat is created in this mode of operation. The valve is a two position, four way (with the A port plugged), single solenoid, spring return, directional valve. Y01.38.20 Directional Valve When the PF3 and PF4 pump volumes required to operate the Indexing Table and/or Broaching Rams, the valve solenoid is energized. This permits the No. 01.25.23 logic valve to operate as a high pressure relief. The pressure that the logic valve opens will be at either 45 bar (when Y01.43.20 is de-energized) or 115 bar (when the same solenoid is energized). The solenoid is energized when necessary to broach the part at the following speeds; 15, 20, 25, and 30 m/minute. When the PF3 pump volumes are not required to operate the Table or Broaching Rams, the valve solenoid is de-energized. This permits the No. 01.25.23 logic valve to open at low pressure (100 PSI or less). This permits the pump volume to return back to the tank at low pressure. Very little heat is created in this mode of operation. The valve is a two position, four way (with the A port plugged), single solenoid, spring return, directional valve. Y01.43.20 Directional Valve When operating the Indexing Table or the entire machine in the manual mode of operation, the valve solenoid is de-energized. The spool directs pilot pressure on the top of the three logic valves to the 45 bar remote relief valve. Once the pilot pressure reaches the 45 bar setting, the selected logic valves will open permitting the excess pump s volume to return back to tank through the specific logic valve. Troubleshooting Broaching Machine Hydraulics Page 5

When the broaching rams are commanded to operate, the valve solenoid energizes. The solenoid will shift the spool into the B position. Pilot pressure is now blocked through the valve because of the pipe plug in the B port. Pilot pressure on top of the logic valves can now build to the setting of the 115 bar remote relief valve. If this pressure is reached while the broaching rams are operating, then the specific logic valve would open dumping the specific pump back to tank at high pressure. Y01.43.20 is a two position, four way (with the B port plugged), single solenoid, spring return, directional valve. Y01.48.20 Directional Valve When the solenoid is de-energized, pressure in the line is ported to the No. S01.49.28 pressure switch. If the setting of this switch is reached 120 bar, then an over pressure condition will be indicated. Depending on the electrical programming, a shut down of the machine may occur. When the valve solenoid energizes, the system pressure is blocked to the pressure switch. At the same time the pressure in the switch is ported to tank through the valve spool. This valve is used for high pressure protection when the No. 1 broaching ram is machining apart. Y01.48.20 is a two position, four way (with the B port plugged), single solenoid, spring return, directional valve. Y01.51.20 Directional Valve When the solenoid is de-energized, pressure in the line is ported to the No. S01.52.28 pressure switch. If the setting of this switch is reached, 120 bar, then an over pressure condition will be indicated. Depending on the electrical programming, a shut down of the Page 6 Troubleshooting Broaching Machine Hydraulics

machine may occur. When the valve solenoid energizes, the system pressure is blocked to the pressure switch. At the same time the pressure in the switch is ported to tank through the valve spool. This valve is used for high pressure protection when the No. 2 broaching ram is machining apart. Y01.51.20 is a two position, four way (with the B port plugged), single solenoid, spring return, directional valve. Y04.03.03 Directional Valve When necessary to lower the Index Table, a voltage is applied to the A solenoid on this valve. Pressurized Y04.09.08 Y04.03.03 fluid is then directed through the spool to the top side of the actuator. As the table lowers, the oil that is forced out of the bottom side of the actuator will return back to the tank through the valve spool. The valve is detented which means that if the voltage were removed, then the spool would remain in the A position. When the command is given to raise the table, a voltage is applied to the B solenoid. The solenoid will shift the spool into the B position directing oil to raise the table. The oil that is forced out of the top side of the cylinder will return to the tank through the valve spool. The spool will remain in the B position because of the valve detent until the A solenoid is energized. The valve is a two position, four way, double solenoid, detented, directional valve. Troubleshooting Broaching Machine Hydraulics Page 7

Y04.09.08 Directional Valve To rotate the table clockwise, a voltage is applied to the A solenoid. Flow from the pumps is then ported to extend the top cylinder (as shown on the schematic) and at the same time retract the bottom cylinder. Once the table is lowered and the No. S04.06.06 switch setting (30 bar) is reached, the B solenoid of this directional valve is energized. Volume is then directed to the bottom cylinder, which after it extends forces the top cylinder to retract to the home position. The turntable is now ready for the next rotation cycle. 01.21.23 Logic Valve This valve is controlled by the Y01.36.20 directional valve. When the PF1 pump volume is not required to operate the Indexing Table or Broaching Rams, the valve solenoid is de-energized. This permits any pressure on top of the logic valve to bleed back to the tank. The logic valve will then open at low pressure (100 PSI or less) directing the pump volume back to the tank at low pressure. When the pump volume is required to operate the Index Table or Broaching Rams, the valve solenoid is energized. Pilot pressure is then ported to the top of the logic valve piston. This pressure will be limited to 45 bar when operating the table and 115 bar when operating the broaching rams. If either of these two pressures are reached during the specific operation, the logic valve will shift open. The pump volume will then return to the tank at high pressure. Heat will be created when this occurs. The logic valve is located inside the valve manifold. 01.22.16 Logic Valve This logic valve will operate as a check valve in this circuit. As long as the pressure at the valve inlet can build higher than the pressure at the outlet, oil can flow from the pump to the system. Once the pressures nearly equalize on both sides of the valve, the piston will shift closed because of the force of the spring. The logic valve is located inside the valve manifold. Page 8 Troubleshooting Broaching Machine Hydraulics

01.23.23 Logic Valve This valve is controlled by the Y01.37.20 directional valve. When the PF2 pump volume is not required to operate the Indexing Table or Broaching Rams, the valve solenoid is de-energized. This permits any pressure on top of the logic valve to bleed back to the tank. The logic valve will then open at low pressure (100 PSI or less) directing the pump volume back to the tank at low pressure. When the pump volume is required to operate the Index Table or Broaching Rams, the valve solenoid is energized. Pilot pressure is then ported to the top of the logic valve piston. This pressure will be limited to 45 bar when operating the table and 115 bar when operating the broaching rams. If either of these two pressures are reached during the specific operation, the logic valve will shift open. The pump volume will then return to the tank at high pressure. Heat will be created when this occurs. The logic valve is located inside the valve manifold. 01.24.16 Logic Valve This logic valve will operate as a check valve in this circuit. As long as the pressure at the valve inlet can build higher than the pressure at the outlet, oil can flow from the pump to the system. Once the pressures nearly equalize on both sides of the valve, the piston will shift closed because of the force of the spring. The logic valve is located inside the valve manifold. 01.25.23 Logic Valve This valve is controlled by the Y01.38.20 directional valve. When the PF3 and PF4 pumps volumes are not required to operate the Indexing Table or Broaching Rams, the valve solenoid is de-energized. This permits any pressure on top of the logic valve to bleed back to the tank. The logic valve will then open at low pressure (100 PSI or less) directing the pump volume back to the tank at low pressure. When the pump volume is required to operate the Index Table or Broaching Rams, the valve solenoid is energized. Pilot pressure is then ported to the top of the logic valve piston. This pressure will be limited to 45 bar when operating the table and 115 bar when operating the broaching rams. If either of these two pressures are reached during the specific operation, the logic valve Troubleshooting Broaching Machine Hydraulics Page 9

will shift open. The pump volume will then return to the tank at high pressure. Heat will be created when this occurs. The logic valve is located inside the valve manifold. 01.26.16 Logic Valve This logic valve will operate as a check valve in this circuit. As long as the pressure at the valve inlet can build higher than the pressure at the outlet, oil can flow from the pump to the system. Once the pressures nearly equalize on both sides of the valve, the piston will shift closed because of the force of the spring. The logic valve is located inside the valve manifold. 01.27.17 Fixed Orifice This orifice will control the rate that the logic valve shifts open and closed. 01.28.17 Fixed Orifice This orifice will control the rate that the logic valve shifts open and closed. 01.29.17 Fixed Orifice This orifice will control the rate that the logic valve shifts open and closed. 01.30.18 Fixed Orifices These orifices are located in a single block and are used to reduce the flow rate in and out of the directional valve. 01.31.18 Fixed Orifices These orifices are located in a single block and are used to reduce the flow rate in and out of the directional valve. 01.32.18 Fixed Orifices These orifices are located in a single block and are used to reduce the flow rate in and out of the directional valve. Page 10 Troubleshooting Broaching Machine Hydraulics

01.33.19 Fixed Orifice The size of the orifice determines the flow rate to the Y01.43.20 directional valve and 01.44.24 and 01.45.25 remote relief valves. 01.34.19 Fixed Orifice The size of the orifice determines the flow rate to the Y01.43.20 directional valve and 01.44.24 and 01.45.25 remote relief valves. 01.35.19 Fixed Orifice The size of the orifice determines the flow rate to the Y01.43.20 directional valve and 01.44.24 and 01.45.25 remote relief valves. 01.39.21 Check Valve The check valve will permit free flow from the top of the logic valve piston to the pilot pressure circuit. The check valve will block flow in the opposite direction. 01.40.21Check Valve The check valve will permit free flow from the top of the logic valve piston to the pilot pressure circuit. The check valve will block flow in the opposite direction. 01.41.21Check Valve The check valve will permit free flow from the top of the logic valve piston to the pilot pressure circuit. The check valve will block flow in the opposite direction. 01.44.24 Remote Relief Valve When the broaching rams are machining a part, the Y01.43.20 directional valve solenoid is energized. Pilot pressure through the directional valve is now blocked. This permits the maximum pressure on top of the 01.21.23, 01.23.23 and 01.25.23 logic valves to build to the setting of this relief, 115 bar. If the pressure at the outlet port of any of the three pump circuits builds to the setting, the valve will shift open also allowing the specific logic valve to open as well. Troubleshooting Broaching Machine Hydraulics Page 11

Flow from the pump will then return back to tank through the specific logic valve at high pressure. Heat will be created when this occurs. 01.45.25 Remote Relief When the Indexing Table is operating, the Y01.43.20 valve solenoid is de-energized. Pilot pressure from the 01.21.23, 01.23.23 and 01.25.23 logic valves is directed to this remote relief valve. If the pressure downstream of the pumps were to reach the valve setting, 45 bar, the logic valves would shift open dumping the pumps volumes back to the tank at high pressure. Heat will be created when this occurs. 04.02.02 Check Valve The check valve will permit free flow from the pumps to raise and lower the Indexing Table cylinder. Once the table is raised the command is given to rotate in a clockwise direction. This check valve will lock oil in the bottom of the raise and lower cylinder. This check will prevent the table from dropping as it rotates. 04.07.07 Check Valve When raising the table, oil will free flow through this check valve and into the bottom of the cylinder. There is another connection at the bottom of the cylinder that will also allow oil in and out of the cylinder. With dual flow paths, more volume can be ported into the cylinder for raising. The check valve will block the flow in one line as the cylinder lowers. This limits the amount of oil that flows out of the bottom side back to the tank. 04.08.02 Check Valve The check valve will allow flow from the pumps into the Indexing Table cylinders. After the table is rotated, the table is commanded to lower. This check valve will lock oil in the Indexing Table cylinders when this occurs. Page 12 Troubleshooting Broaching Machine Hydraulics

04.10.09 Pressure Reducing Valve This valve will reduce the system pressure down to 40 bar for operating the Indexing Table. The valve spool will shift between the fully open and fully closed positions permitting only enough oil through to maintain the setting of the 40 bar spring. This valve is of the cartridge type and is screwed into the side of the block. Troubleshooting Broaching Machine Hydraulics Page 13

Indexing Table Troubleshooting Broaching Machine Hydraulics Page 14

Troubleshooting Broaching Machine Hydraulics Page 15

Troubleshooting Broaching Machine Hydraulics Page 16

Troubleshooting Broaching Machine Hydraulics Page 17