Initial Development of an Advanced Test Method for Jet Fuel Identification and Characterization

Similar documents
GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology

UPDATE OF THE SURVEY OF SULFUR LEVELS IN COMMERCIAL JET FUEL. Final Report. November 2012

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Application Note. Abstract. Authors. Environmental Analysis

APPLICATION OF SOLID PHASE MICROEXTRACTION (SPME) IN PROFILING HYDROCARBONS IN OIL SPILL CASES

Rapid Qualitative GC-TOFMS Analysis of a Petroleum Refinery Reformate Standard

Analysis of Fatty Acid Methyl Esters (FAMES), and Examination of Biodiesel Samples for these Components, by GCxGC-FID

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

Using the PSD for Backflushing on the Agilent 8890 GC System

CONSTITUTION OF COAL TAR PITCH AND ITS EFFECT ON PROPERTIES

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

High-Temperature Simulated Distillation System Based on the 6890N GC Application

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems

Creation of the 16-hour Engine Test Schedule from the Heavy Heavy-Duty Diesel Engine Test Schedule

Determination of Free and Total Glycerin in B100 Biodiesel

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Application. Gas Chromatography June 1995

White Paper.

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Comprehensive Gas Chromatography (GCxGC) Analysis of High-Ethanol Containing Motor Fuels

REPORT DOCUMENTATION PAGE

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

Application Note. Author. Introduction. Energy and Fuels

Technical Procedure for Gas Chromatography (GC-FID)

Analysis of Glycerin and Glycerides in Biodiesel (B100) Using ASTM D6584 and EN Application. Author. Abstract. Introduction

Definition of White Spirits Under RAC Evaluation Based on New Identification Developed for REACH

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Analysis of Petroleum Fractions by ASTM D2887

DETERMINATION OF N-BUTANOL AND ISOBUTANOL IN GASOLINE USING GAS CHROMATOGRAPHY (GC-FID)

Paragon Scientific Ltd Proficiency Testing Scheme Schedule

Forensic Identification of Gasoline Samples D.A. Birkholz 1, Michael Langdeau 1, Preston Kulmatycki, 1 and Tammy Henderson. Abstract.

Ultrafast GC Performance in the Real World: Multi Lab Studies for Repeatability & Reproducibility

Agilent Multimode Inlet for Gas Chromatography

DIFFERENTIATION OF CRUDE OILS, FUEL OILS, AND USED LUBRICATING OIL USING DIAGNOSTIC RATIOS

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

This presentation focuses on Biodiesel, scientifically called FAME (Fatty Acid Methyl Ester); a fuel different in either perspective.

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

STUDIES ON FUSHUN SHALE OIL FURFURAL REFINING

Meeting the Requirements of ASTM D ( IP548/06 ) with Agilent 1200 LC Systems

1-3 Alkanes structures and Properties :

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

Heating Methods. Reflux and Distillation

Method Development for Capillary GC Systems. Slide 1

Automated Screening of GC-TOFMS Chromatograms with Specific Detection for Chlorine, Bromine, and Sulfur Containing Compounds

Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 )

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

Characterization of Tiki Torch Fuels

Renewable Fuels Association One Massachusetts Ave. NW Suite 820 Washington, DC Telephone: (202) Fax: (202)

Performing ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software

Types of Oil and their Properties

Study of viscosity - temperature characteristics of rapeseed oil biodiesel and its blends

V. G. Spirkin, O. P. Lykov, and O. M. Bel dii UDC

AppNote 6/2006. Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) KEYWORDS

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

Technical Procedure for the Examination of Arson Evidence

Application Note. Authors. Abstract. Energy & Chemicals

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC

CRC Project No. AV-1-04

CHALLENGES WITH PETROLEUM SPILL CHARACTERIZATION Ralph Ruffolo Ontario Ministry of the Environment and Climate Change Laboratory Services Branch 125

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

PETROLEUM SUBSTANCES

INTEREST OF HPTLC FOR FOSSIL DERIVED PRODUCTS ANALYSIS : A SIMPLE APPROACH TO HYDROCARBON GROUP TYPE ANALYSIS

Article: The Formation & Testing of Sludge in Bunker Fuels By Dr Sunil Kumar Laboratory Manager VPS Fujairah 15th January 2018

Metathesis Catalysts

Large Volume Injection of Polycyclic Aromatic Hydrocarbons

Evaluation of Total Petroleum Hydrocarbon in Soil Using LC with Fraction Collector and GC/MS

Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS)

A Comparison of Boat Introduction and Direct Injection using the Thermo Scientific ipro 5000 Series Combustion Analyzer

Simultaneous Determination of Fatty Acid Methyl Esters Contents in the Biodiesel by HPLC-DAD Method

CRC Report No. E-79 COORDINATING RESEARCH COUNCIL, INC MANSELL ROAD SUITE 140 ALPHARETTA, GA 30022

Agilent and ASTM. Update on Recent Activities. Page 1

Operation and Applications of Differential Flow Modulation

Estimation Procedure for Following Vapor Pressure Changes

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

Dr. Carl Rechsteiner, Research Scientist Chevron Corporation Dr. Brian Rohrback, President Infometrix, Inc. Chevron 2012

Module8:Engine Fuels and Their Effects on Emissions Lecture 36:Hydrocarbon Fuels and Quality Requirements FUELS AND EFFECTS ON ENGINE EMISSIONS

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

Correlating TBP to Simulated Distillations. COQA Long Beach, CA

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Agilent Solutions for the Petrochemical and Oleochemical Industries

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

ASTM D for Denatured Fuel Ethanol Automating Calculations and Reports with Empower 2 Software

Stray Gassing of Transformer. Streams and Addi;ves. Ed Casserly, Ph.D. Director - Refinery R&D Ergon Refining, Inc.

Transcription:

CRC Project AV-09-09 Initial Development of an Advanced Test Method for Jet Fuel Identification and Characterization Phase 1 December 2010 CRDINATING RESEARCH CUNCIL, INC. 3650 MANSELL RAD SUITE 140 ALPHARETTA, GA 30022

The Coordinating Research Council, Inc. (CRC) is a non-profit corporation supported by the petroleum and automotive equipment industries. CRC operates through the committees made up of technical experts from industry and government who voluntarily participate. The four main areas of research within CRC are: air pollution (atmospheric and engineering studies); aviation fuels, lubricants, and equipment performance, heavy-duty vehicle fuels, lubricants, and equipment performance (e.g., diesel trucks); and light-duty vehicle fuels, lubricants, and equipment performance (e.g., passenger cars). CRC s function is to provide the mechanism for joint research conducted by the two industries that will help in determining the optimum combination of petroleum products and automotive equipment. CRC s work is limited to research that is mutually beneficial to the two industries involved, and all information is available to the public. CRC makes no warranty expressed or implied on the application of information contained in this report. In formulating and approving reports, the appropriate committee of the Coordinating Research Council, Inc. has not investigated or considered patents which may apply to the subject matter. Prospective users of the report are responsible for protecting themselves against liability for infringement of patents.

LEGAL NTICE This report was prepared by the University of Washington Research Foundation (UW) as an account of work CRC by the Coordinating Research Council (CRC). Neither the CRC, members of the CRC, UW nor any person acting on their behalf: (1) makes any warranty, express or implied, with respect to the use of any information, apparatus, method, or process disclosed in this report, or (2) assumes any liabilities with respect to use of, inability to use, or damages resulting from the use or inability to use, any information, apparatus, method, or process disclosed in this report. 3

Executive Summary CRC Project Final Report Phase 1 December 29, 2010 Initial Development of an Advanced Test Method for Jet Fuel Identification and Characterization Robert E. Synovec, Jamin C. Hoggard and W. Christopher Siegler Department of Chemistry, ox 351700 University of Washington, Seattle, WA, 98195 This is a report of progress toward developing an advanced test method for jet fuel identification and characterization using GC GC TFMS instrumentation. Sample selection, instrumental methods, and data analysis conducted relevant to the development of a test method are detailed in the report and appendices. Results give some compositional (chemical) characteristics of different fuel types, outline compositional trends (similarities and differences) among fuel types, demonstrate the advantage of GC GC over GC, and give further direction and insight into future investigation for characterization and identification of jet fuel using GC GC TFMS and GC GC instrumentation. List of Tables and Figures Figure 1: Retention structure of relevant compound classes using the developed GC GC TFMS methods. Figure 2: 2D GC GC and GC chromatograms (TIC) of sample C3 (Jet A) with select compounds annotated. Figure 3: A comparison of the number of peaks detected in GC GC vs. GC. Figure 4: 2D GC GC and GC chromatograms (TIC) of sample C146 (downgraded jet fuel) with select compounds annotated. Figure 5: 2D GC GC and GC chromatograms (TIC) of sample C378 (JPTS) with select compounds annotated. Figure 6: 2D GC GC and GC chromatograms (TIC) of sample C17 (Stoddard solvent) with select compounds annotated. Figure 7: 2D GC GC and GC chromatograms (TIC) of sample C247 (JP10) with select compounds annotated. Figure 8: 2D GC GC and GC chromatograms (TIC) of sample C268 (priming fluid) with select compounds annotated. Figure 9: 2D GC GC and GC chromatograms (TIC) of sample C435 (Fischer-Tropsch jet fuel) with select compounds annotated. Figure 10: 2D GC GC and GC chromatograms (TIC) of sample C432 (Fischer-Tropsch diesel fuel) with select compounds annotated. 4

Figure 11: 2D GC GC and GC chromatograms (TIC) of sample C840 (ultra-low sulfur diesel fuel) with select compounds annotated. Figure 12: 2D GC GC and GC chromatograms (TIC) of sample C56 (F76) with select compounds annotated. Figure 13: 2D GC GC and GC chromatograms (TIC) of sample C783 (marine gas oil) with select compounds annotated. Figure 14: 2D GC GC and GC chromatograms (TIC) of sample C992 (hydrotreated fatty-acid methylesters) with select compounds annotated. Figure 15: 2D GC GC and GC chromatograms (TIC) of sample C822 (100) with select compounds annotated. Table 1: A summary of the chemical compositions of 13 different fuels by compound class. 5

CRC Project Final Report Phase 1 December 29, 2010 Initial Development of an Advanced Test Method for Jet Fuel Identification and Characterization Robert E. Synovec, Jamin C. Hoggard and W. Christopher Siegler Department of Chemistry, ox 351700 University of Washington, Seattle, WA, 98195 ackground This project explores the use of fast two-dimensional gas chromatography (GC GC) with Time of Flight Mass Spectrometry (TFMS) detection to elucidate the chemical compositions of current petroleum-based fuels as well as unconventional synthetic and alternative fuels. GC GC analysis provides extensive additional characterization information beyond what is available from one-dimensional gas chromatography (GC). This is accomplished by resolving standard GC chromatographic peaks in a second dimension taking advantage (for example) of polarity differences of multiple compounds that may be incorporated in a single GC peak. In other words, GC alone often results in convoluted peaks where confirmation of their identity with mass spectral (MS) analysis becomes quite difficult. Characterization of the thousands of compounds found in distillate fuels by GC GC greatly elucidates their make up with finer resolution and offers new opportunities for correlating fuel specifications and/or fuel performance as a function of fuel composition. GC GC can also offer finer resolution with increased speed (analysis time) compared to standard GC methods. The primary goal of Phase 1 was to determine the extent to which the chemical information obtained from GC GC TFMS instrumentation can be used to more fully understand the nature and compositional distributions of conventional petroleum jet fuels and jet fuels derived from alternative sources. The intent was to qualitatively compare the data from GC GC TFMS instrumentation relative to the data obtained using GC-MS instrumentation. To achieve this goal, the two objectives were (1) to explore the use of GC GC TFMS detection to elucidate the chemical compositions of current petroleum-based fuels as well as unconventional synthetic and alternative fuels, ultimately using the instrument in a fast separation run mode, and (2) to establish a comprehensive fuel compositional database and determine the extent to which chemometric modeling of GC GC TFMS can be used to rapidly determine fit for purpose. To achieve these objectives, the proposed research was separated into two phases, with Phase 1 focusing on the first objective, and with Phase 2 planned to focus on the second objective. Experimental Materials We began by selecting 99 samples for analysis from among the 966 samples contained in the provided NRL Calibration Fuel sample key spreadsheet. Samples were chosen so that each type of fuel was represented. Further details of the sample selection are included in Appendix A. Experimental Approach To better understand the nature and compositional distributions of these fuels (from conventional petroleum fuels as well as fuels derived from alternative sources), 13 samples were selected, each representing a different fuel type; these were analyzed using a slightly modified in-house standard diesel analysis method on a Leco Pegasus III 4D instrument (GC GC TFMS), with the methods used described in the following paragraph: 6

An autoinjector (Agilent 7683 series) was used with a 10 µl syringe, delivering 1 µl of sample to the inlet for each replicate. Samples were injected neat (with no liquid solvent dilution) and the syringe rinsed with acetone between runs. The inlet was configured for a 200:1 split, and used a complex pressure program that essentially corrected the second column flow to be constant and approximated a constant flow of 2.0 ml He/min. The capillary GC columns used were: column 1: 20 m, 250 µm ID, 0.5 µm X-5 film; column 2: 2 m, 180 µm ID, 0.2 µm X- 200 film. The chromatographic temperature profile used was as follows. The temperature program for column 1 began at 50 ºC for 0.25 min, then ramped at 5 ºC/min up to 300 ºC, which was held for 5 min. The temperature program for column 2 was the same except all temperatures were 5 ºC higher. The inlet was set at 275 ºC, the modulator block for +20 ºC, and the transfer line at 305 ºC. Full mass spectra (m/z 12 to 340) were collected at 100 spectra/s after 6 s into each run. A modulation period of 1.5 s was used, where the modulation period is the separation time on column 2. We next developed a faster (15 min run time, 25 min cycle time) GC GC TFMS instrumental method for analysis of all 99 samples provided by Robert Morris (Naval Research Laboratory). Each of the 99 samples was run on the instrument 4 times (yielding 4 replicates) using this fast method. Details of this method follow. An autoinjector (Agilent 7683 series) was used with a 5 µl syringe, delivering 0.5 µl of sample to the inlet for each replicate. Samples were injected neat (with no liquid solvent dilution) and the syringe rinsed with acetone between runs. The inlet was configured for a 150:1 split, and was set to constant flow mode at 2.0 ml He/min. The capillary GC columns used were: column 1: 20 m, 250 µm ID, 0.5 µm X-5 film; column 2: 2 m, 180 µm ID, 0.2 µm X-200 film. The chromatographic temperature profile used was as follows. The temperature program for column 1 began at 40 ºC for 1 min, then ramped at 20 ºC/min up to 290 ºC, which was held for 1.5 min. The temperature program for column 2 was the same except all temperatures were 10 ºC higher. The inlet was set at 280 ºC, the modulator block for +15 ºC, and the transfer line at 290 ºC. Full mass spectra (m/z 12 to 502) were collected at 200 spectra/s after 30 s into each run. A modulation period of 0.5 s was used to ensure that there would be at least 3 (more typically 4) modulations across each peak along the first separation dimension. Results Total ion current (TIC) chromatograms of each of the 13 representative samples analyzed are shown in the figures below along with annotations of selected compounds of interest detected in the samples. Also shown are a figure outlining the retention structure of a number of major compound classes in these separations (Figure 1) and a figure highlighting the difference in separation power of these compounds obtained using GC GC vs. GC analysis by means of a peak maximum finding algorithm (Figure 3), with GC chromatograms for this and subsequent figures obtained by summing across the second separation dimension of the GC GC data. Therefore, the GC chromatograms shown here are formed from eliminating the column 2 separation information by reducing each separation in the column 2 dimension down into a single point. In the peak finding comparison between GC GC and GC, we typically located about four times the number of peaks in a given separation time using GC GC as compared with using GC. Each of the different fuel types analyzed generally showed significant visible differences in chemical composition from the other fuel types, so the capabilities of GC GC TFMS to characterize fuel composition and to determine the chemical similarity (or differences between) fuels in the training set fuels was established. Example TIC chromatograms from some of the 99 sample replicates run with the fast method are included in Appendix. 7

Conclusions To summarize the results of the GC GC TFMS analysis of the 13 different fuels shown in the figures below (Figures 2, 4 15), we present Table 1, which outlines the compositional distribution by compound class. Structural annotation of the compounds shown in each of Figures 2 & 4 15 was based on both mass spectrum and Kovat's retention indices of the compound for the stationary phases employed, using the NIST database as reference. Compounds may elute at a different time or order than expected in another analysis due to the particular stationary phase used, the fact that retention occurs across two different stationary phases, and different instrumental conditions such as temperature program and carrier gas flow rate. A fuel-by-fuel comparative compositional analysis is included in each of the respective figure captions, compositional trends across the different fuels are given in Table 1, and many specific compounds are annotated in the chromatograms in Figures 2, 4 15. Results in Table 1 are very promising in relation to an ultimate goal of correlating fuel performance data with chemical composition (group type) information provided by the 2D GC GC (Figure 1) information. Recommendations for Future Work For future work, including a comprehensive principal component analysis (PCA) may provide clustering in scores plots and may enable similar fuels to be differentiated, which in turn would lead to chromatographic (and m/z) locations (and thus compounds), that can better differentiate the different fuels. In addition, partial least squares (PLS) models of preprocessed data could lead to more discriminating or selective analyses for physical properties (those for which sufficient data was provided) or between the different fuel types, again pointing to compositional differences in different fuel samples or types. Although not a part of the statement of work for the present project, using enough samples, compositional bounds for fuels in terms of commonly measured properties could also be defined through these types of analyses. (Figures begin on next page.) 8

1.5 Time, Column 2, seconds (polarity) 0.0 0 Time, Column 1, minutes 50 (boiling point) Figure 1: The retention structure of several chemical classes for the separation conditions used is shown above. Classes are (from bottom to top): blue alkanes, green branched alkanes, purple cycloalkanes, red monoaromatics, orange diaromatics, black polyaromatics. The scale on the y-axis is from 0 to 1.5 seconds, and the scale of the x-axis is from 0 to 50 minutes retention time. A C D E F A A S S A C A C D (cis) (trans) S C A A D H A A C A C7H16 C9H20 C8H18 C10H22 C11H24 C D C12H26 C13H28 C14H30 C15H32 E F C17H36 C19H40 C16H34 C18H38 C20H42 2D, GC GC 1D GC 50 min 500 1000 1500 2000 2500 3000 Figure 2: 2D GC GC and GC chromatograms (TIC) of sample C3 (Jet A) are shown above annotated with some compounds of interest. The column 1 retention times (s) are vertically aligned. 9

10 7 4.0 3.5 3.0 2.5 2.0 1.5 9.0 11.8 14.6 Column 1 Time, minutes Figure 3: A comparison of the number of peaks detected in a subsection of the GC GC and GC chromatograms (shown in the previous figure) using a local maximum-based peak finding algorithm. 201 peaks were found in the GC GC subsection, while 49 peaks were found in the same subsection of the GC chromatogram. 10

A (cis) C (trans) H 2D, GC GC E F missing A C C9H20 C8H18 C10H22 C11H24 C12H26 C13H28 C14H30 C15H32 E F C7H16 C17H36 C19H40 C21H44C23H48 C16H34 C18H38 C20H42 C22H46C24H50 1D GC 50 min 500 1000 1500 2000 2500 3000 Figure 4: 2D GC GC and GC chromatograms (TIC) of sample C146 (downgraded jet fuel) are shown above annotated with some compounds of interest. The column 1 retention times (s) are vertically aligned. X markers indicate compounds not seen in this sample that are seen in sample C3. For this sample, some of the more volatile compounds seen in C3 are missing, as well as many of the heavier aromatics. 11

H no sulfur compounds (PAHs visible) 2D, GC GC C7H16 C9H20 C8H18 C10H22 C11H24 C12H26 C13H28 C14H30 C15H32 C17H36 C16H34 1D GC 50 min 500 1000 1500 2000 2500 3000 Figure 5: 2D GC GC and GC chromatograms (TIC) of sample C378 (JPTS) are shown above annotated with some compounds of interest. The column 1 retention times (s) are vertically aligned. Sulfur containing compounds present in C3 are not visible in the 2D GC GC chromatogram. There is also a slightly narrower boiling point distribution with more compounds with lower boiling points compared with C3. 12

H 2D, GC GC C7H16 C9H20 C8H18 C10H22 C11H24 C12H26 C13H28 C14H30 C15H32 1D GC 50 min 500 1000 1500 2000 2500 3000 Figure 6: 2D GC GC and GC chromatograms (TIC) of sample C17 (Stoddard solvent) are shown above annotated with some compounds of interest. The column 1 retention times (s) are vertically aligned. This sample looks intermediate between a gasoline and jet fuel; more oxygenated compounds are readily apparent than in most of the other samples. 13

2D, GC GC H C7H16 C9H20 C8H18 C10H22 C11H24 C12H26 C13H28 C14H30 C15H32 1D GC 50 min 500 1000 1500 2000 2500 3000 Figure 7: 2D GC GC and GC chromatograms (TIC) of sample C247 (JP10) are shown above annotated with some compounds of interest. The column 1 retention times (s) are vertically aligned. This sample consists primarily of cyclic alkanes, with some alkane, branched alkane, and aromatic compounds also present. utylated hydroxytoluene is also present, likely added as an antioxidant, but no other oxygenated compounds are readily visible. 14

2D, GC GC H C7H16 C9H20 C8H18 C10H22 C11H24 C12H26 C13H28 C14H30 C15H32 C17H36 C16H34 1D GC 50 min 500 1000 1500 2000 2500 3000 Figure 8: 2D GC GC and GC chromatograms (TIC) of sample C268 (priming fluid) are shown above annotated with some compounds of interest. The column 1 retention times (s) are vertically aligned. This sample could be a mixture of JP10 and jet fuel. However, it contains a significant amount of methylcyclohexane not seen in sample C247. 15

A (cis) C (trans) A C D E G 2D, GC GC A C G D C7H16 C9H20 A C8H18 C10H22 C11H24 C C12H26 C13H28 C14H30 C15H32 E C17H36 C19H40 C21H44C23H48 C16H34 C18H38 C20H42 C22H46 1D GC 50 min 500 1000 1500 2000 2500 3000 Figure 9: 2D GC GC and GC chromatograms (TIC) of sample C435 (Fischer-Tropsch jet fuel) are shown above annotated with some compounds of interest. The column 1 retention times (s) are vertically aligned. This sample consists primarily of branched and normal alkanes, with much fewer aromatic compounds visible than for a petroleum-derived fuel. As expected, the pristane and phytane peaks present for petroleum-derived fuels (containing the sufficiently high boiling point compounds) are not visible (green X's). 16

A C D E G F 2D, GC GC C6H14 C5H12 G A C9H20 C8H18 C10H22 C11H24 C D C12H26 C13H28 C14H30 C15H32 E F C7H16 C17H36 C19H40 C21H44 C23H48 C16H34 C18H38 C20H42 C22H46 C24H50 C25H52 C26H54 C27H56 C28H58 C29H58 1D GC 50 min 500 1000 1500 2000 2500 3000 Figure 10: 2D GC GC and GC chromatograms (TIC) of sample C432 (Fischer-Tropsch diesel fuel) are shown above annotated with some compounds of interest. The column 1 retention times (s) are vertically aligned. This sample is similar to C435 (above), but also contains higher boiling point branched and normal alkanes (those with longer chain lengths). 17

A (cis) C (trans) E no sulfur compounds (PAHs visible) F 2D, GC GC A C C9H20 C8H18 C10H22 C11H24 C12H26 C13H28 C14H30 C15H32 E F C7H16 C17H36 C19H40 C21H44 C23H48 C16H34 C18H38 C20H42 C22H46 C24H50 C25H52 C26H54 C27H56 C28H58 C29H60 1D GC 50 min 500 1000 1500 2000 2500 3000 Figure 11: 2D GC GC and GC chromatograms (TIC) of sample C840 (ultra-low sulfur diesel fuel) are shown above annotated with some compounds of interest. The column 1 retention times (s) are vertically aligned. This sample is somewhat similar to C3, but contains higher boiling point compounds and much fewer heteroatom containing compounds. As such, it resembles a typical ULSD. 18

A (cis) C (trans) A S S S N H 2D, GC GC A S A C C9H20 C8H18 C10H22 C11H24 C12H26 C13H28 C14H30 C15H32 E F C7H16 C17H36 C19H40 C21H44 C23H48 C16H34 C18H38 C20H42 C22H46 C24H50 C25H52 C26H54 C27H56 C28H58 C29H60 1D GC 50 min 500 1000 1500 2000 2500 3000 Figure 12: 2D GC GC and GC chromatograms (TIC) of sample C56 (F76) are shown above annotated with some compounds of interest. The column 1 retention times (s) are vertically aligned. This sample appears similar to diesel fuel, but contains more aromatic and heteroatom containing compounds (particularly for the higher boiling point compounds). 19

A (cis) C (trans) S A S S S N H 2D, GC GC H A S A C C9H20 C8H18 C10H22 C11H24 C12H26 C13H28 C14H30 C15H32 E F C7H16 C17H36 C19H40 C21H44 C23H48 C16H34 C18H38 C20H42 C22H46 C24H50 C25H52 C26H54 C27H56 C29H60 C28H58 1D GC 50 min 500 1000 1500 2000 2500 3000 Figure 13: 2D GC GC and GC chromatograms (TIC) of sample C783 (marine gas oil) are shown above annotated with some compounds of interest. The column 1 retention times (s) are vertically aligned. This sample appears similar to F76, but contains even more aromatic and heteroatom containing compounds (particularly for the higher boiling point compounds). However, the boiling point distribution of this sample is more similar to diesel. 20

A C D E G F 2D, GC GC G D F C7H16 C9H20 A C8H18 C10H22 C11H24 C C12H26 C13H28 C14H30 C15H32 E C17H36 C19H40 C16H34 C18H38 C20H42 1D GC 50 min 500 1000 1500 2000 2500 3000 Figure 14: 2D GC GC and GC chromatograms (TIC) of sample C992 (hydrotreated fatty-acid methylesters) are shown above annotated with some compounds of interest. The column 1 retention times (s) are vertically aligned. This sample appears similar to a Fischer-Tropsch jet fuel (primarily containing branched and normal alkanes), although the distribution of some of the branched compounds appears to be different. Again, no pristane or phytane peaks are visible (green X's). 21

3 4 2 1 3 sterols 4 2 1 2D, GC GC C5H12 1D GC 50 min 500 1000 1500 2000 2500 3000 Figure 15: 2D GC GC and GC chromatograms (TIC) of sample C822 (100) are shown above annotated with some compounds of interest. The column 1 retention times (s) are vertically aligned. This sample mostly consists of a few fatty-acid methylesters (some saturated, others not, and primarily of about five different chain lengths). As opposed to the other samples where there are obvious benefits in resolving compounds of different classes when using GC GC, this sample is simple enough that GC-MS analysis alone would suffice (although some benefit from the GC GC retention structure does remain). 22

Figure # Sample Type alkanes branched alkanes cyclic alkanes di-aromatics yes; high yes; only 2 C3 Jet A concentrations, yes; many yes yes; many yes; many phenanthrene C6-C20 visible yes; high yes; many, but 4 C146 dg-jet concentrations, yes; many yes yes; many fewer more no C6-C24 substituted yes; high yes; many, but 5 C378 JPTS concentrations, yes; many yes yes; many fewer more no C6-C17 substituted yes; high 6 C17 st-solvent concentrations, yes; many yes yes; many yes; few no C7-C15 7 C247 JP10 yes; lower yes; very concentrations, yes; few concentrated C7-C15 yes; some yes; very little no HT 8 C247 priming yes; lower yes; very concentrations, yes; many concentrated C6-C17 yes; some yes no HT yes; lower 9 C435 FTJ concentrations, yes; many yes yes; some no no ethyl acetate C7-C23 yes; lower 10 C432 FTD concentrations, yes; many yes; few yes; some no no no C5-C29 yes; high yes; only 11 C840 ULSD concentrations, yes; many yes yes; many yes; many phenanthrene no C6-C29 visible yes; high 12 C56 F76 concentrations, yes; many yes yes; many yes; many yes C6-C29 yes; high 13 C783 MG concentrations, yes; many yes yes; many yes; many yes C6-C29 yes; high 14 C992 HT-FAME concentrations, yes; many yes; few no no no no C7-C20 15 C822 100 no no no no no no monoaromatics polyaromatics heteroatomics yes; sulfur containing cyclics, dibenzofuran, some alcohol yes; sulfur containing cyclics, some alcohols only 2-(2-methoxyethoxy)- ethanol yes; various oxygenated compounds yes; thiophenes, furans, carbazole yes; various oxygenated compounds, thiophenes, furans, carbazole yes; FAMEs with chain lengths ~8-22, aldehydes, some other oxygenated Table 1: A summary of the chemical compositions of 13 different fuels by compound class, as provided by locations in the 2D separation space. For more details on the specific compounds, see Figures 2, 4 15. 23

Appendix A. Sample Selection Details. 1. Samples were separated by category (i.e. jet fuel, MG, nonfuel, etc.) so as to include samples from each category. 2. Samples labeled as outliers (not including downgraded fuels) were removed. 3. For those categories with more than 14 samples (except the synthetic blends i.e. FT fuels), a design of experiments using Kennard-Stone Uniform mapping of the optimal design space. [Ref: Technometrics Vol. 11 Number 1, 1969] to reduce the number of samples down to 14. The key variables used for this were: Flash point, Freeze point, IP, 90% P, and FP. 4. Samples having few measured property values (especially for the key properties) were removed from the list. 5. Duplicate samples in origin, date, and property values were removed from the list. This was done such that the replicates chosen to be removed were picked at random. From subsequent instrumental analysis, none of the samples chosen by the Kennard-Stone method appeared to be duplicates. 24

Appendix. Example TIC Chromatograms From the Set of 99 Fuels Run using the Fast Method. Sample name, fuel type, and replicate number are given for each of the shown TIC chromatograms. C3 Jet A (rep.3) C290 JPTS (rep.1) C433 FTD (rep.4) 25

C436 FTJ (rep.2) C992 HTFAME (rep.1) C73 dg-jet (rep.3) C822 100 (rep.4) 26

C920 MG (rep.2) C837 ULSD (rep.2) C100 F76 (rep.3) C268 Priming Fluid (rep.4) 27

C247 JP-10 (rep.1) 28