Flow. PanaFlow LZ. User s Manual. bhge.com

Similar documents
GE Measurement & Control Solutions. Model T9. Ultrasonic Flow Transducer. Installation Guide

T5 Flare Gas Transducer

GE Measurement & Control Solutions. CModel C-RS. Ultrasonic Flow Transducer. Installation Guide

GE Measurement & Control. Model T17. Ultrasonic Flow Transducer. Installation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

GE Sensing & Inspection Technologies. Model UTXDR. Panametrics Ultrasonic Flow Transducer. Installation Guide

INSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

GE Measurement & Control. DewPro MMY30. User s Manual

SITRANS P measuring instruments for pressure

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

AquaTrans AT600. Panametrics Clamp-on Ultrasonic Liquid Flow Meter. Imagination at work. Version 3 (12/1/14)

AquaMaster4 Electromagnetic flowmeter flanged sensor

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

GETTING STARTED GUIDE NI Channel Sinking Digital Input Module

RVP-R- VAV controller. In explosion-proof version

Flow Measurement SITRANS F S Clamp-on

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Operator Instructions for Tension Links

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Operation Manual for. CU2 Helmholtz Coil System Closed-Loop Module

CU2 Closed Loop Module

VLM20 In-line Vortex Flowmeter

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

Rosemount 485 Annubar Threaded Flo-Tap Assembly

1000 Series Piston Type Differential Pressure Gauges

GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

Rosemount 585 Annubar Flanged Flo-Tap Assembly

MV Series. Smith Meter Turbine Meters. Features. Operating Specifications SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 2.0 (2/18)

Operating Instructions

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

Solenoid Operator 0516 / 1216

Rosemount 485 Annubar Flanged Assembly

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Mod: KLD6-12/35XLAS-N

GETTING STARTED GUIDE NI AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous

1100 Series Piston Type Differential Pressure Gauges

Condensed Version of Operator s Manual For The VL600 Series Flowmeters

Ex m Solenoid Operator Type 0519

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

CPC DX (CPC Dual Transfer Skid) Redundant current to pressure converter assembly

GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

BARTON 7400 Precision Gas Turbine Flow Meters

Lamp kit. Installation manual SIM 7 series R

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

DIAMOND POINT VIBRATING PROBES

NI 9251 with mini XLR

Installation and Operating Manual

Rosemount 285 Annubar Pak-Lok Assembly

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF

Manual Turbine Flow Meters HM Series

Surface thermocouple Model TC50

Cylindrical Silencers

ECO PLUS RAPID DOOR USER S AND INSTALLER S MANUAL

SFI SPECIFICATION 49.2 EFFECTIVE: MARCH 22, 2011 *

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Cable resistance thermometer Model TR40

Power-Limiting Cables

Magnetic-inductive flow meter for hazardous areas

Masoneilan * Series

Installation Instructions for Appleton Mercmaster LED Luminaire

GE Panametrics Ultrasonic Flow Meter

Safety Shock Absorbers SCS33 to SCS64

Rosemount 405 Compact Primary Element. Quick Start Guide , Rev HA June 2016

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

362 Clamp Meter. Users Manual

289 Series Relief Valves

TIDALFLUX 2300 F Quick Start

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

INSTALLATION RULES for SCS/SENSOR Pt100

SeekTech Inductive Clamp

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes

Model DFX Doppler ultrasonic flow meter

Proximity Transmitters, and Seismic Vibration Transmitters

SFI SPECIFICATION 14.3 EFFECTIVE: AUGUST 25, 2017 *

Installation and Operation Manual. Value Switch Package (VSP and VSP+)

Installation, Operation, and Maintenance Manual

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

HTSB system System overview

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Net +Plus Connection Code

Logix 3800 Digital Positioner

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Rosemount 3095FT MultiVariable Flow Data Logger

Differential Pressure Transmitter

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

These installation and maintenance instructions must be read in full and completely understood before the installation!

Transcription:

Flow PanaFlow LZ User s Manual bhge.com 910-316 Rev. A September 2017

Preface Product Registration Thank you for purchasing your PanaFlow LZ from Baker Hughes, a GE Company. Please register your product at www.gemeasurement.com/productregistration for product support such as the latest software/firmware upgrades, product information and special promotions. Services BHGE provides customers with an experienced staff of customer support personnel ready to respond to technical inquiries, as well as other remote and on-site support needs. To complement our broad portfolio of industry-leading solutions, we offer several types of flexible and scalable support services including: Training, Product Repairs, Extended Warranties, Service Agreements and more. Please visit www.gemeasurement.com/services for more details. Terms and Conditions Sales Terms and Conditions for your recent purchase of a BHGE product, including the applicable product Warranty, can be found on our website at the following link: www.gemeasurement.com/sales-terms-and-conditions Typographical Conventions Note: These paragraphs provide information that provides a deeper understanding of the situation, but is not essential to the proper completion of the instructions. IMPORTANT: These paragraphs provide information that emphasizes instructions that are essential to proper setup of the equipment. Failure to follow these instructions carefully may cause unreliable performance. CAUTION! This symbol indicates a risk of potential minor personal injury and/or severe damage to the equipment, unless these instructions are followed carefully. WARNING! This symbol indicates a risk of potential serious personal injury, unless these instructions are followed carefully. Safety Issues WARNING! It is the responsibility of the user to make sure all local, county, state and national codes, regulations, rules and laws related to safety and safe operating conditions are met for each installation. Attention European Customers! To meet CE Marking requirements for all units intended for use in the EU, all electrical cables must be installed as described in this manual. PanaFlow LZ User s Manual 3

Preface Auxiliary Equipment Local Safety Standards The user must make sure that he operates all auxiliary equipment in accordance with local codes, standards, regulations, or laws applicable to safety. Working Area WARNING! Auxiliary equipment may have both manual and automatic modes of operation. As equipment can move suddenly and without warning, do not enter the work cell of this equipment during automatic operation, and do not enter the work envelope of this equipment during manual operation. If you do, serious injury can result. WARNING! Make sure that power to the auxiliary equipment is turned OFF and locked out before you perform maintenance procedures on this equipment. Qualification of Personnel Make sure that all personnel have manufacturer-approved training applicable to the auxiliary equipment. Personal Safety Equipment Make sure that operators and maintenance personnel have all safety equipment applicable to the auxiliary equipment. Examples include safety glasses, protective headgear, safety shoes, etc. Unauthorized Operation Make sure that unauthorized personnel cannot gain access to the operation of the equipment. 4 PanaFlow LZ User s Manual

Preface Environmental Compliance RoHS The PanaFlow LZ fully complies with RoHS regulations (Directive 2011/65/EU). Waste Electrical and Electronic Equipment (WEEE) Directive BHGE is an active participant in Europe s Waste Electrical and Electronic Equipment (WEEE) take-back initiative (Directive 2012/19/EU). The equipment that you bought has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health and the environment. In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems. Those systems will reuse or recycle most of the materials of your end life equipment in a sound way. The crossed-out wheeled bin symbol invites you to use those systems. If you need more information on the collection, reuse and recycling systems, please contact your local or regional waste administration. Please visit http://www.gemeasurement.com/environmental-health-safety-ehs for take-back instructions and more information about this initiative. PanaFlow LZ User s Manual 5

Preface [no content intended for this page] 6 PanaFlow LZ User s Manual

1.0 Contents Introduction................................................................................................ 1 Unpacking the PanaFlow LZ System........................................................................ 2 Site Considerations........................................................................................ 3 Installing Cable Glands..................................................................................... 5 Specifications............................................................................................. 12 2.0 Introduction To ensure safe and reliable operation of the PanaFlow LZ flow meter system, it must be installed in accordance with established guidelines. Those guidelines are discussed in this manual and in the flow transmitter User s Manual. IMPORTANT: The PanaFlow LZ flow meter system may be supplied with a variety of GE flow transmitters (XMT1000, XMT910, XMT900, XMT868i, etc.). Be sure to refer to the User s Manual for your specific flow transmitter. Attention! Because the PanaFlow LZ system has the flexibility to use several different GE flow transmitters, the photographs used in this manual may appear slightly different from your system. However, the basic instructions are valid for all PanaFlow LZ systems. WARNING! The PanaFlow LZ flow meter can measure the flow rate of many fluids, some potentially hazardous. The importance of proper safety practices cannot be overemphasized. WARNING! Be sure to follow all applicable local safety codes and regulations for installing electrical equipment and working with hazardous fluids or flow conditions. Consult company safety personnel or local safety authorities to verify the safety of any procedure or practice. Attention! To meet CE Mark requirements, all cables must be installed as described in the flow transmitter User s Manual. CE Mark compliance is required for all systems intended for use in EU countries. PanaFlow LZ User s Manual 1

3.0 Unpacking the PanaFlow LZ System Before removing the PanaFlow LZ system from the crate, please inspect the flow meter. Before discarding any of the packing materials, account for all components and documentation listed on the packing slip. The discarding of an important item along with the packing materials is all too common. If anything is missing or damaged, contact GE Customer Care immediately for assistance. 3.1 Identification The PanaFlow LZ meter has up to three separate labels for identification, depending on its configuration. The system is mounted as a single unit. 3.2 Lifting the PanaFlow LZ System Figure 1 below indicates the proper way to attach the lifting straps to any GE flow meter system. Attention! Because the PanaFlow LZ system has the flexibility to use several different GE flow transmitters, the photographs used in this manual may appear slightly different from your system. However, the basic instructions are valid for all PanaFlow LZ systems. WARNING! This is the only approved way to lift a PanaFlow system into position in the pipeline. Never lift the system by the flow transmitter mounted on top of the flowcell. Figure 1: Lifting a Typical GE PanaFlow System 2 PanaFlow LZ User s Manual

4.0 Site Considerations 4.1 Local Mounting The flow transmitter accuracy is affected by the flowcell location in the process piping and on the orientation of the transducers. Thus, in addition to accessibility for maintenance, adhere to the following installation guidelines: Locate the flowcell so that there are at least 10 pipe diameters of straight, undisturbed flow upstream and 5 pipe diameters of straight, undisturbed flow downstream from the measurement point (see Figure 2 below). Undisturbed flow means avoiding sources of turbulence in the fluid (e.g., valves, flanges, expansions, elbows, etc.), avoiding swirl, and avoiding cavitation. 10D Flow Direction Figure 2: Minimum Straight Run Pipe Requirements Locate the transducers on a common axial plane along the pipe. Also, locate them on the side of the pipe instead of on the top or the bottom, because the top of the pipe tends to accumulate gas and the bottom tends to accumulate sediment. Either condition will cause unwanted attenuation of the ultrasonic signals. There is no similar restriction with vertical pipes, as long as the fluid flow is upward to prevent free falling of the fluid or a less than full pipe (see Figure 3 below). 5D Horizontal Flowcell Vertical Flowcell GOOD Flow Direction BAD Flow Direction GOOD Flow Direction BAD Figure 3: Good and Bad Flowcell/Transducer Orientations CAUTION! Do not place thermal insulation on or around the transducers, the junction boxes, or the meter electronics. The transducer and junction box act as a heat sink that protects the transducer from high and low temperatures. PanaFlow LZ User s Manual 3

4.2 Remote Mounting The standard flow transmitter enclosure is a powder-coated, aluminum, IP67 explosion-proof enclosure. Typically, the enclosure is mounted as close as possible to the transducers. When choosing a site for a remote-mount installation, which is recommended for process temperatures exceeding 150 C, make sure the location permits easy access to the enclosure for programming, maintenance and service. Attention! For compliance with the European Union s Low Voltage Directive, this unit requires an external power disconnect device such as a switch or circuit breaker. The disconnect device must be marked as such, clearly visible, directly accessible, and located within 1.8 m (6 ft) of the transmitter. 4.3 Cable Lengths Locate the flow transmitter as close as possible to the transducers. The maximum distance from the transducers for remote mounting is 1000 ft (300 m) using RG-62 coaxial cable or equivalent. If longer distances are required, consult the factory for assistance. 4.4 Transducer Cables When installing the transducer cables, always observe established standard practices for the installation of electrical cables. Do not route transducer cables alongside high amperage AC power lines or any other cables that could cause electrical interference. Also, protect the transducer cables and connections from the weather and corrosive atmospheres, and be sure to follow the manufacturer's installation guidelines if cable glands are provided. 4.5 Insulation Do not place thermal insulation on or around the transducer locations or the flow transmitter. The enclosures act as heat sinks that protect against high and low temperatures. 4.6 Vibration Exposure Considerations Whenever possible, install the flow transmitter in a location isolated from vibrations. Avoid installing it near equipment that generates low-frequency, high-energy random vibrations. 4.7 Sunlight Exposure The installer should consider and limit exposure of the flow transmitter to direct sunlight. Sunshades should be utilized in extreme environments. 4 PanaFlow LZ User s Manual

5.0 Installing Cable Glands When wiring the PanaFlow LZ system in accordance with the instructions in the flow transmitter User s Manual, it is essential that the cable glands be properly installed. To accomplish this, carefully complete the following steps: WARNING! Failure to properly install the cables in the glands will compromise the environmental ratings of the PanaFlow LZ system. Note: These instructions apply to all installations using the GE 704-861, 704-862, and 704-863 cable assemblies. 1. Remove the Rubber Boot from the cable gland and slide it back over the cable (see Figure 4 below). Rubber Boot Back Nut Middle Nut Threaded Entry Figure 4: Removing the Rubber Boot 2. Disassemble the Cable Gland (see Figure 5 below). However, DO NOT try to separate the pieces of the Armor Clamp that secures the cable armor, as these pieces are permanently assembled. Armor Clamp Figure 5: Disassembling the Cable Gland PanaFlow LZ User s Manual 5

5.0 Installing Cable Glands (cont.) 3. Tighten the Threaded Entry (see Figure 6 below) with a wrench to form a permanent joint. Threaded Entry Figure 6: Tightening the Threaded Entry 4. Insert the Coaxial Cable into the Threaded Entry (see Figure 7 below). Threaded Entry Coaxial Cable Figure 7: Inserting the Coaxial Cable into the Threaded Entry 6 PanaFlow LZ User s Manual

5.0 Installing Cable Glands (cont.) 5. Push the Coaxial Cable into the gland until the Armor Clamp is fully inserted into the Threaded Entry section. (see Figure 8 below). Armor Clamp Threaded Entry Figure 8: Inserting the Armor Clamp into the Gland 6. Screw the Middle Nut onto the cable gland to secure the clamped section (see Figure 9 below). Middle Nut Figure 9: Installing the Middle Nut PanaFlow LZ User s Manual 7

5.0 Installing Cable Glands (cont.) 7. Tighten the Middle Nut completely by hand (see Figure 10 below). Middle Nut Figure 10: Tightening the Middle Nut by Hand 8. Tighten the Middle Nut with a wrench, but be very careful not to overtighten the nut or the Armor Wires may be broken (see Figure 11 below). Middle Nut Figure 11: Tightening the Middle Nut with a Wrench 8 PanaFlow LZ User s Manual

5.0 Installing Cable Glands (cont.) 9. Screw the Back Nut over the Retaining Collar (see Figure 12 below). Back Nut Figure 12: Screwing the Back Nut Over the Retaining Collar 10. Hand tighten the Back Nut to secure the Coaxial Cable and make a weather-tight seal (see Figure 13 below). Back Nut Figure 13: Tightening the Back Nut by Hand PanaFlow LZ User s Manual 9

5.0 Installing Cable Glands (cont.) 11. Slide the Rubber Boot down the cable and over the Cable Gland Assembly (see Figure 14 below). Rubber Boot Back Nut Figure 14: Sliding the Rubber Boot Over the Cable Gland Assembly 12. Make sure the Rubber Boot completely covers the Cable Gland and that no tears have occurred in the boot during the assembly process (see Figure 15 below). Rubber Boot Threaded Entry Figure 15: The Completed Cable Gland Assembly 10 PanaFlow LZ User s Manual

5.0 Installing Cable Glands (cont.) 13. After the coaxial cables have been properly installed in their cable glands, they must be connected to the terminal blocks inside the flow transmitter enclosure (see Figure 16 below) as follows: Attention! Because the PanaFlow LZ system has the flexibility to use several different GE flow transmitters, the photographs used in this manual may appear slightly different from your system. However, the basic instructions are valid for all PanaFlow LZ systems. a. Connect the transducer wires to their terminal block per the instructions in the User s Manual for your flow transmitter. b. Make sure all of the transducer wires are properly dressed and that they are neatly arranged inside the flow transmitter enclosure. c. Use the flexible strain reliefs inside the flow transmitter enclosure to keep all of the transducer wires clear of the threaded areas. Flexible Strain Relief Figure 16: Terminating the Transducer Cables PanaFlow LZ User s Manual 11

6.0 Specifications 6.1 Operation and Performance Fluid Types Liquids: acoustically conductive fluids, including most clean liquids, and many liquids with small amounts of entrained solids or gas bubbles Flow Measurement Correlation Transit Time model Paths 1-Path: 2 in. to 24 in. (50 mm to 600 mm) pipe 2-Path: 3 in. to 24 in. (80 mm to 600 mm) pipe Pipe Sizes 2 to 24 in. (50 to 600 mm) Pipe Material Carbon steel Stainless steel (316/316L) Accuracy ±0.5% of reading for velocity above 2 ft/s (0.6 m/s) up to 40 ft/s (12.2 m/s) with a resolution of ± 2 mm/s Accuracy statement assumes measurement of a single phase homogeneous liquid with a fully developed symmetrical flow profile passing through the meter. Applications with piping arrangements that create an asymmetrical flow profile may require extended piping straight runs and/or flow conditioning for the meter to perform to this specification. Repeatability ±0.3% of reading typical Range (Bidirectional) ±0.1 to 40 ft/s (0.03 to 12.19 m/s) Measurement Parameters Dependent upon flow transmitter used. Please refer to individual flow transmitter product data sheet. 6.2 Electronics/Flow Transmitter Temperature Range Operating: -40 to 140 F (-40 to +60 C) Storage: -67 to 167 F (-55 to 75 C) 12 PanaFlow LZ User s Manual

6.3 Meter Body and Transducer Pressure Rating Up to maximum allowable flange operating pressure at temperature, per ASME B16.5 Temperature Range WT Transducers:-40 to 175 C (-40 to 347 F) BWT Transducers:-40 to 100 C (-40 to 212 F) -40 to 250 C (-40 to 482 F) Temperature rating of -20 C if used with carbon steel meter body Transducer Material 316L Stainless steel (buffers) Meter Body Materials Carbon steel Stainless steel (316/316L) Certification Electronics/Transducers: Explosion-proof Class I, Division 1, Groups B,C&D ATEX Flameproof II 2 G Ex d IIC T6 IECEx Flameproof II 2 G Ex d IIC T6 (BWT only) Flow Cell: NACE MR0175 and MR0103, PED 2014/68/EU Dimensions Refer to drawings 712-2122 to 712-2125 Drawing Description 712-2122 General arrangement drawing, PanaFlow LZ, 2 & 3, 1 path, 2 traverse, tilted diameter 712-2123 General arrangement drawing, PanaFlow LZ, 4 to 24, 1 path, 1 traverse, tilted diameter 712-2124 General arrangement drawing, PanaFlow LZ, 3 & 4, 2 path, 1 traverse, tilted diameter 712-2125 General arrangement drawing, PanaFlow LZ, 6 to 24, 2 path, 1 traverse, mid-radius PanaFlow LZ User s Manual 13

6.4 Transducer Cables Integral Cables Mineral insulated cables with potted cable glands (for North America & Canada hazardous locations) Armored flame retardant coaxial cables with ATEX/IECEx certified cable glands (for European hazardous locations) Remote Cables ATEX/IECEx: Armored RG-62 for ATEX/IECEx US/CAN: Non-armored RG-62, conduit not included Remote cables are not included and must be ordered separately. Maximum cable length is 1000 ft (300 m). 14 PanaFlow LZ User s Manual

Customer Support Centers U.S.A. The Boston Center 1100 Technology Park Drive Billerica, MA 01821 U.S.A. Tel: 800 833 9438 (toll-free) 978 437 1000 E-mail: sensing@ge.com Ireland Sensing House Shannon Free Zone East Shannon, County Clare Ireland Tel: +353 61 61470200 E-mail: gesensingsnnservices@ge.com bhge.com 2017 Baker Hughes, a GE company All rights reserved. Baker Hughes reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your BHGE representative for the most current information. The Baker Hughes logo is a trade mark of Baker Hughes, a GE company. The GE Monogram is a trademark of the General Electric Company. 910-316 Rev. A