Flanders Electric Engineering Division

Similar documents
Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

SWITCHGEAR DIVISION PRODUCT PROFILES

University of Houston Master Construction Specifications Insert Project Name

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

B BASIC HEAT TREATMENT CONSOLE

*PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS*

ECET 211 Electric Machines & Controls Lecture 1-3 (Part 2) Electrical Safety in the Workplace Electrical Safety in the Workplace

FEBRUARY 14, 2017 Elastimold Solid dielectric switchgear customer presentation

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

Integrated Power Solutions

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Medium Voltage Metal-Enclosed Switches

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Switchgear Skid, C1192

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Air-insulated switchgear UniGear type ZS1

Power/Vac Switchgear Concepts And Basic Configurations

T300MVi JK OEM POWER CELLS MEDIUM VOLTAGE VACUUM CONTACTOR. Reliability in motion. Reliability in motion

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

PUB NLH 174 Island Interconnected System Supply Issues and Power Outages Page 1 of 4

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Linear Fluorescent Lampholders. Compact Fluorescent Lampholders (CFL s)

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Issued Revised Approved Reviewed October 31, 1984 October 22, 2002 J. Ross J. Fuller

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Medium Voltage Metal-Enclosed Switches

IN2 Enclosed Switches and Circuit Breakers

INSTALLATION INSTRUCTIONS

RV Park Equipment Product Focus. Power Pedestals Distribution Equipment

C1000 Series Automatic Cap Bank

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

NEXT STEP B) SAFETY :

PRODUCT/SERVICE CLASSIFICATION CLASS 285 ELECTRICAL EQUIPMENT AND SUPPLIES (EXCEPT CABLE AND WIRE)

Power Distribution - 30KVA - 480V to 120V & 220V - Ten 120 Volt GFCI Outlets - Two 220 Volt Outlet

Metal Clad Switchgears

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

Transmission & Distribution Glossary of Electrical Terms

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Power Distribution - 30KVA - 480V to 120V & 220V - Ten 120 Volt GFCI Outlets - Two 220 Volt Outlet

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme)

User's Manual. Earth Ground Resistance Tester. Model Introduction

Eaton Corporation An Overview Eaton Corporation. All rights reserved.

University of California, San Diego Cal (IT) 2 Technical Assignment #2. Brian Smith

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

Eylander Electric Inc

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Evaluating Water-Damaged Electrical Equipment

Solid Dielectric, Single Phase Reclosers

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

75 KVA Transformer Power Distribution - 480V to 120/208V - Nema 3R V and 8 120V Outlets

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

Joslyn Clark Controls, Inc. Simple, Safe, Retrofit Programs to Significantly Extend Life of Existing Circuit Breakers

MaxSG Low Voltage Switchgear

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Cutler-Hammer. January 2001

Generation Interconnection Facilities Study For

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

Power/Vac Vacuum Replacement Breakers for GE Magne-Blast Type AM & AMH Breakers

SafeLink The Ultimate RMU. Rex de Bruyn PTMV New Zealand. ABB Ltd - Page 1 ABB

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

SafeGear TM Motor Control Center Arc resistant metal-clad construction

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

Selection Guide Motor Control Device Solutions

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

RUS accepted Catalog O-vst18

STL. Series. Emergency Lighting Inverter 3kW to 160kW Central System

Section 18. Medium Voltage Equipment. BuyLog Catalog 18-1

Typical Specification

Two Recent Case Studies in the Mining Industry

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE

Magnetech Products & Services

Ampgard The name motor applications rely on

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

HIGH POWER RECTIFIER SYSTEMS

A. Submit manufacturer's literature and technical data before starting work.

Electrical Existing Conditions and Building Load Summary Report

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

INSTALLATION & OPERATION MANUAL

DS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1

INSTALLATION INSTRUCTIONS

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Cutler-Hammer. January 2001

Transcription:

Flanders Electric Engineering Division Welcomes You to an Overview of Reconditioned Switchgear Lou York Bill Oxby

Reasons for Reconditioning Switchgear Cost Savings Reuse material Buswork Building/enclosure Components Energy Efficiencies Shorter Production outages often required with switchgear upgrades

Reasons for Reconditioning Switchgear con t Technology Upgrade Obsolete Parts Replacement Vacuum Contactors/Breakers Solid State Protection Web Enabled Power Monitoring Equipment (wireless Ethernet) Environmental Considerations Removal of Equipment From Old Mines More Energy Efficient Components

Basic inspections/cleanings on all components Visually inspect for hot spots/fluid leaks etc. Visually inspect all Connections i.e. Power Cable Clamps (draglines) Fuse Clips (loose, corrosion) Meggar/Hi Pot Line and Load Conductors Inspect Insulators, Bushings and Surge Arrestors Thoroughly Clean Compartment Remove: Dirt, Rocks, Excess oils, Rodent infestation Inspect all components for excess wear and damage

Basic inspections/cleanings on all components (con t) Clean and Calibrate Electro-Mechanical Protection Devices (if not being replaced) Oil Analysis where necessary For Load Break Switches Adjust and lubricate linkages as necessary

Technology Upgrades Typically Recommended Change OCB s (Oil Filled Circuit Breakers) to Vacuum Circuit Breakers Replace Capacitive Trip Devices Depending upon Age Change Electro-Mechanical Overload protection devices to Solid State Improve Repeatability and Accuracy

Technology Upgrades Typically Recommended (con t) Replace old lighting with more energy efficient lighting -High pressure sodium or Metal Halide on outside -Replace incandescent lights with fluorescent bulbs in sockets Replace low voltage, air contactor size 4 and above with vacuum contactors and any medium voltage with vacuum contactor -Improves contactor life (number of cycles) -Minimizes effect of environmental elements on contacts

Safety Related items must do Simulate all Ground Faults Upgrade all receptacles to GFCI type Repair all door interlocks per MSHA Install new safety signage/warning labels Check Ground Monitor (Coal Mines)

Standards Followed National Electrical Code UL/c UL Underwriters Laboratory EIA RS821 Electronics Industries Assoc.: Construction Standards Mining Safety and Health Administration ANSI American National Standards Institute NFPA 79 Electrical Standard for Industrial Machinery

Just a few examples

Example # 1 Medium Voltage Pump Sub Specifications 7200/480Y, 225KVA Description of operation - Transformer and Breaker to Feed Pumps for Water Removal

Example # 1 Medium Voltage Pump Sub Summary Material Cost $6,500.00 Repair Load Switch Replace two 480VAC Breakers Labor cost $1,200.00 Total Cost $7,700.00 Estimated Cost of new $30,000

Example # 2 OCB Vacuum Retrofit Specifications Voltage: 7200VAC Current: 400 Amp Description of Operation Dragline Contactor for Motor Starting with Overload and Ground Fault Protection

Example # 2 OCB - Vacuum Retrofit Summary Material Cost $9,000.00 Labor cost $1000.00 Total Cost $10,000.00 Estimated Cost of new Switchgear: $55,000.00 Other Savings/Benefits: Installation of new contactor during normal outage time.

Example # 3 Portable Breaker House Specifications Voltage: 4160 VAC Current: 1200 Amps Description of operation Converted 7200VAC Portable Breaker House to 4160 Line Drop Station

Example # 3 Portable Breaker House Summary Items Replaced (2) Potential Transformers (PT s) (3) 5kV Bushing Assemblies Material Cost $5,000.00 Labor cost $8,000.00 Total Cost $13,000.00 Estimated Cost of new $50,000.00

Example # 4-3 Way Switch House Specifications Voltage 7200 VAC Current 400 amps Description of operation - Switches to Provide Alternative Feed for Distribution. Single Main to 3 feeds

Example # 4 3 Way Switch House Summary Material Cost $900.00 Mechanical Interlocks Calibration Labor cost $1,000.00 Total Cost $1,900.00 Estimated Cost of new $25,000.00

Example # 5 Large Portable Substation Specifications Voltage 23,000VAC Current 1000 amps Description of operation - Power Feed and Distribution to Dragline

Material Cost Example # 5 Large Portable Switchgear Summary Items Replaced Replaced 25KV OCB Contacts and Changed Oil Ground Monitor GE Potential Transformer Labor cost $11,000.00 Total Cost $27,000.00 $16,000.00 (includes purchase of used skid) Estimated Cost of new $75,000.00

Questions???