The Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor

Similar documents
The Combustex Pilot Pro 500 Ignition System with Pilot Tip and Flame Sensor

The Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor

Igniter, BMS & Valve Parts Directory Contact Us Toll Free:

PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER

INSTALLATION MANUAL ACL 5500 COMBUSTION SAFETY CONTROLLER

RED DRAGON ELECTRONIC PROPANE FLARE

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING

SERVICE MANUAL (INTERNATIONAL)

IGNITION FLAME SAFETY CONTROLLER

TFL Gas Log Lighter (TFLGLL)

Applies to: Models F, B, FE, and BE with spark pilot

G76x Direct Spark Ignition Controls

SERVICE MANUAL RRG SERIES HEAVY DUTY GAS GRIDDLE - NOTICE - ML ML ML RRG Shown

GEMINI GAS CONTROL PRODUCT INFORMATION

Specifications of STICKTITE and PILOTPAK Nozzles

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

Specifications of STICKTITE and PILOTPAK Nozzles

PT-M90 Automatic Full-Sequence Modulation Gas Control System

E Series CE Approved Intermittent Pilot Ignition Control

Start-up Instructions

Design and Application Details

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

Gas Conversion Kits and Instructions

36H Gas Control Product Information

Water Valve Shutoff. WVS Water Valve Shutoff

Operating Manual. Safety/Process Flare Pilot

LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

High Tension Spark Igniter (HTSI)

BG1600M Intermittent Pilot Ignition Control

(For serial numbers before w/ analog control)

SERVICE MANUAL (INTERNATIONAL)

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

G600 Series Replacement Intermittent Pilot Ignition Controls

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

Part List: Jandy LXI Series Heaters

SECTION 3.00 WARNING WARNING ENGINE STARTUP AND SHUTDOWN PRESTART INSPECTION

Miata - Workshop Manual - Engine

Page 1 sur 5. Diagnostic Trouble Code Diagnosis Charts. Sportage [AL] > 2000 > Engine > 2.0 DOHC

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

G-II PCM MODEL HEATERS: TO DATE. Rev. C

HOT AIR LANCE PART MANUAL Rev. A

DRIVEABILITY - GAS. All symptoms listed above are diagnosed using the same tests. The title for the tests will be P0300-MULTIPLE CYLINDER MIS-FIRE.

MAXIGARD A2000 SPEED SWITCH. Introduction

Crest Heating Boilers FBN(L)

MODEL RVS304. REMOTE CONTROLLED SAFETY PILOT KIT Supplemental Installation Instructions for use with Natural Gas Log Sets

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

G72x Series Direct Spark Ignition Controls

Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

Troubleshooting guide for poor acceleration, black smoke, and flash code 39, SID 147, FMI 7 or 2

Troubleshooting Electronic Ignition

HIGH QUALITY GAS PRODUCTS SINCE 1957

PF 3100 ION PILOT CARD PRO.FIRE

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

SD Bendix M-21 and M-22 AntiLock Modulator Assembly DESCRIPTION M-21 MODULATOR M-22 MODULATOR

TROUBLESHOOTING. 1. What is the model and serial number? If you don t know, how old is it? Give description.

Stock Pot Range. models (Electric) E20-SP, E20-SPC (Gas) G20-SP, G20-SPH.

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

B21 Series BASOTROL Gas Valve

Baumann Series Flexsleev Control Valve Instructions

ROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

High Frequency SineWave Guardian TM

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

GAS FIRED BROILERS 36W36 235W36 43W36 243W36 136W36 C36 V136W36 C45

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

36C and 36D Gas Control Product Information

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

INSTALLATION DATA 712 Series Pilot

AHE S - 12 VDC AHE X - 12 VDC AHE X - 12 VDC

Pilot Capacities/Specifications

Voltmaster Centrifugal Trash Pumps

Series 20 Installation Instructions

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

2.0 Burner Operating Parameters and Requirements

Direct Gas-Fired Heating

6 Gauge Box Set IS0332

Stock Pot Range. Gas & Electric Models. Parts List. GAS Models: ELECTRIC Models: G20-SP G20-SPH E20-SP E20-SPH. G20 shown

Models: AFVK-SP-SPLIT AFVK-SP-H/L-SPLIT AFVK-SP-MH/L-SPLIT INSTALLATION AND OPERATING INSTRUCTION

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

M-SERIES DIAPHRAGM COMPRESSOR REBUILD KIT

Manifold Isolation Valves

SERVICE MANUAL. K Series Gas Kettles 2/3 Jacketed Stationary and Tilting - NOTICE - K40GL Shown

SD SERIES SD 448, SD 1048, SD 660, SD 1060, SD 866 AND SD , 6 AND 8 PIE PIZZA OVENS REPLACEMENT PARTS LIST

Q SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Heating and Gas Installations - December 2014

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Troubleshooting Manual

REV 1.7 PROFIRE 2100 MANUAL BURNER MANAGEMENT SYSTEM

BGH2UNCNTRLHT-01 Universal Hot Surface Ignition Control

DEXEN INDUSTRIES Inc. GENERAL CATALOG. DEXEN INDUSTRIES Inc.

AUTOMATIC REMOTE CAPABLE SAFETY PILOT SYSTEM

Transcription:

OPERATIONS MANUAL The Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor

KEY FEATURES Strong, Reliable Ignition & Pilot Flame Rapid Flame Response LED Flame Status Indicator Fully Protected Ignition Lead with Optional High Temp. Sheath Low Fuel Gas Consumption Robust Aluminum / SS Construction Rated for Class 1, Div. 2 Hazardous Locations B149.3 Compliance * * When installed with a BMS-2000 Series Burner Management System. TECHNICAL SPECIFICATIONS Electrical Environment Power Supply Current Draw Ignition Fuel Gas Fuel Type Working Pressure Maximum Test Pressure Fuel Consumption Physical Operating Temperature Materials and Parts Supply Port Mounting CSA C22.2 Class 1 Div. 2 Groups B, C and D Hazardous Locations 12-24 VDC 75mA (normal operation) 25 KV Natural Gas or Propane 7-9 Psi 15 Psi 8 SCFH, 16,500 BTU/Hr. (nat. gas) -40 to +40 C Aluminum, SS 1/4 NPT 1/2 NPT Close Nipple / Meyers Hub

The Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor OPERATIONS MANUAL Combustex recommends that this manual be read thoroughly before attempting installation or operation of the Pilot Pro 900. SAFETY FIRST. Operational Description Parts List & Diagram Installation Guidelines Operating Procedure Maintenance Requirements p 1 p 2 p 3 p 8 p 8 The Pilot Pro 900 Electronic Ignition Assembly provides the three primary functions required to establish and maintain pilot flames reliably and safely: Pilot flame ignition Flame rod flame sensing Contained and non-intrusive lighting This unit is normally installed with a Combustex BMS-2000 Series Burner Management System or similar type of sequencing apparatus. The Pilot Pro Series igniters have been designed and built around the features of the BMS-2000. All Pilot Pro 900 units are function tested on a BMS- 2000 sequencer prior to shipment from the factory. A clean natural gas or propane supply is required on the supply port. When the pilot fuel gas valve is opened, supplying the igniter with fuel gas, an ignition signal is sent to the electronic ignition assembly from a controller for an 10 second (max.) period. When the pilot gas ignites, a flame rod sensor provides a signal for flame detection. This signal should be used to establish a threshold to indicate flame or flame failure.

2 of 10 15 5 6 USER-SUPPLIED 1/2 PILOT PIPE TO BE SCHED. 40, NOT TO EXCEED 30 16 11 3 8 13 8 12 7 INSTALL SPARK ROD TIP 1/8 FROM WALL OF PILOT HOOD 4 14 SEE WIRING DIAGRAM (P. 6) FOR CONNECTIONS TO IGNITION MODULE 1 9 2 Item Qty. Description Part No. 1 1 Cl. 1, Div. I & II Enclosure Base 1031 2 1 Killark HK2D Cap 1032 3 1 Hub 1/2 x 1/2 F/F 1383 4 1 Spark Rod 1384 5 1 1/2 Ground Clamp 1560 6 1 Burn Nozzle 1386 7 1 Serial Number Tag 1404 8 2 1/2 NPT Close Nipple 1015 9 1 Ignition Module (Flame Rod) 1590 10 1 #10-24 x 5/16 Screw (not shown) 1058 11 1 Ignition Wire (SA) 1416 12 1 Electrode Mounting Bracket 1418 13 1 1/2 Electrical Aluminum Seal 1014 14 1 Ground Wire 1399 15 1 Air / Fuel Mixer Orifice 1535 16 1 Air / Fuel Mixer Venturi Body 1534

3 of 10 MOUNTING Installation as per the Pilot Pro 900 Burner Installation Assembly drawing (see p. 4) is recommended. The mounting location chosen on the vessel should be determined by Operator accessibility and visibility Entry into the fire tube Ease of tubing installation The recommended mounting location of the Pilot Pro 900 shall be located to enable a smooth and reliable ignition of the main flame over the entire firing range of the burner. Mount the pilot end approximately 1.5 behind the main burner and, where possible, at a slight angle so that the pilot flame protrudes into the main gas stream. Note that the pilot flame extends out approximately 5-6 from the end of the pilot. The igniter should be supported at about midpoint within the fire tube with either a J bracket or cross support. The 1/2 pilot pipe between the venturi and burn nozzle is not provided by Combustex. This pipe is user-supplied and fabricated according to the user s specific installation requirements. Combustex recommends the use of schedule 40 pipe not exceeding 30. Note: For proper operation, ensure that the overall installation configuration is such that the length of the ignition wire does not exceed 10 feet.

4 of 10 Combustex Pilot Pro 900 Burner Installation Assembly Top View USER-SUPPLIED 1/2 PILOT PIPE TO BE SCHED. 40, NOT TO EXCEED 30 1.500 1/8 SPARK ROD GAP Notes Ensure ground wire connects Ignition Module ( GND ) and 1/2 ground clamp. End of Pilot Pro 900 igniter unit should be approximately 1.5 behind main burner. Pilot flame extends out approximately 5 inches. Igniter SHOULD NOT be installed with tip extending past the end of the main burner. Mount pilot nozzle on a slight angle so the pilot flame protrudes into main gas stream. Ensure gap between spark rod tip and wall of pilot hood is approx. 1/8. Ensure ignition wire length does not exceed 10 feet.

5 of 10 PIPING The Pilot Pro 900 is normally installed with a Combustex BMS-2000 Series Burner Management System or other similar type of sequencing apparatus. P&ID drawings for the igniter unit are included in the BMS-2000 literature. Installation as per these Combustex-approved drawings is recommended. If the unit is to be installed with a controller other than the BMS-2000, consult the manufacturer s literature for proper piping arrangements. A clean, steady gas supply is required for optimum reliable operation. It is recommended that a filtered instrument regulator be installed upstream of the unit directly at the point where the instrument gas is tapped off of the main fuel gas line. The Pilot Pro 900 is rated for sour gas service, with higher maintenance requirements expected when operated on this type of gas. Where only sour or extreme wet gas is available for fuel, it may be advantageous to operate the pilot and instruments from an auxiliary propane source. For installations where only wet fuel gas is available, it is recommended that a coalescing filter be installed on the pilot gas at a point before the gas leaves the heated building or, in cases where no building exists, directly after the filter regulator. Where concerns of freezing exist, keep the lines as short as possible and slope them back towards a drip pot located in a heated enclosure. Insulating the pilot supply and output lines, along with heat tracing where possible, will help in solving freeze-up problems. These problems can also be minimized on new installations by locating the supply line under the vessel insulation. 3/8 cadmium plated or stainless steel tubing, supported adequately, is recommended. Ensure that when installing the tubing, adequate flexibility is provided, allowing for removal and insertion of the unit during maintenance. Use an approved aluminum thread lubricant on the fittings inserted into the supply and output ports. Avoid stresses created by improperly installed tubing.

6 of 10 Wiring The Pilot Pro 900 is normally installed with a Combustex BMS-2000 Series Burner Management System or similar type of sequencing apparatus. If the unit is to be installed with a controller other than the BMS-2000, consult the manufacturer s literature for proper wiring schematics. The Pilot Pro 900 is CSA approved for Class 1, Div. 2 Group BC or D hazardous locations. Interconnecting wiring between the pilot / ignitor assembly and Combustex BMS-2000 must be #14 or #16 Belden or equivalent with shields tied to the BMS-2000 end only. At this gauge, ensure that the distance between the pilot / ignitor assembly and Combustex BMS unit does not exceed 50 feet. Note: If more than 50 feet is required, increase the wire gauge such that line resistance no greater than 0.5Ω is achieved. High Voltage Ignition Wire to Spark Rod #14 Two Wire Shielded Belden. Shield Tied to BMS Controller Only Terminals Internal to BMS-2000 Controller TS2 (See Note 2) 1 2 3 GND Termiated to 1/2 ground clamp on pilot assembly TS7 (See Note 3) 1 2 3 IGNITOR Module 550/900 Rev 7.2 P/N : 1590 1. ATTACH DC VOLTMETER TO TEST POINT TP1 2. PUSH PB1 BUTTON 3. TURN TRIMPOT1 TO ADJUST DC LEVEL ON TP1 1. FLAME ON/OFF = LED ON/OFF 2. DC VOLTAGE ON TP1 REPRESENTS FLAME QUALITY 3. HIGHER DC VOLTAGE = BETTER FLAME QUALITY ( DC Range 0.0 to 3.0 VDC ) Combustex Corp. PCB P/N : 1589 ASM P/N: 1592 2013 REV 7.2 FQ GND #16 Three Wire Shielded Belden. Shield Tied to BMS Controller Only GND GND +24V FSA FSB IGN CN1 4 5 6 7 8 TS3 1 2 3 4 5 6 4 5 6 7 8 TS8 1 2 3 4 5 6 Notes 1. Igniter O/P in BMS must be configured to YES for Aux Steady Ign O/P 2. TS2 for single burner. TS2 and TS1 for dual burner. 3. TS7 for single burner. TS7 and TS9 for dual burner. 24 VDC 7 8 7 8 Neg Pos

7 of 10 Flame Voltage Levels The Pilot Pro 900 utilizes Flame Ionization Detection for rapid flame response, and the ignition module is preset for typical conditions. Certain environmental and fuel gas variables, however, can result in less-than-ideal pilot flame strength and profile, thereby affecting flame voltage and system operation. Once the unit has been installed and wired, remove the enclosure cap (item #2) to access the ignition module. Use a volt meter to read the DC voltage across the FQ (flame quality) terminal or TP1 node (+) and the GND terminal or node ( - ). See diagram below. First, take a reading without a pilot flame. The NO FLAME ( base) voltage will read 0.5 VDC. Next, ignite the pilot. When the pilot flame is achieved, the red LED will light. Use the volt meter to read the pilot flame signal voltage. High quality pilot flames will generate FLAME ON voltage readings between 2.3 and 2.8 VDC. Wind, poor fuel gas and other factors may degrade the pilot flame quality, indicated by lower voltage readings, and can, in turn, affect overall system operation. If FLAME ON voltage readings are below 2.3 VDC, contact Combustex directly for troubleshooting assistance. 2.6 IGNITOR Module 550/900 Rev 7.2 P/N : 1590 1. ATTACH DC VOLTMETER TO TEST POINT TP1 2. PUSH PB1 BUTTON 3. TURN TRIMPOT1 TO ADJUST DC LEVEL ON TP1 1. FLAME ON/OFF = LED ON/OFF 2. DC VOLTAGE ON TP1 REPRESENTS FLAME QUALITY 3. HIGHER DC VOLTAGE = BETTER FLAME QUALITY ( DC Range 0.0 to 3.0 VDC ) Combustex Corp. PCB P/N : 1589 ASM P/N: 1592 2013 REV 7.2 FQ GND CN1 GND GND +24V FSA FSB IGN

8 of 10 The Pilot Pro 900 is controlled by the Combustex BMS-2000 Series Burner Management System or similar type of sequencing apparatus. Operating instructions and safety information are included in the BMS-2000 literature. If the unit is to be installed with a controller other than the BMS-2000, consult the manufacturer s literature for operating information. Note: It is the responsibility of the operator or controller to ensure that the fire tube has had enough time to be purged of combustible mixtures prior to attempting to relight the unit. Due to the possibility of a control valve leak, the main fuel gas valve should be closed for a period of time to ensure air purging of the fire tube. The main gas valve should not be reopened until a pilot flame has been confirmed. For trouble free operation, a maintenance and inspection schedule should be set up. Every 3 months, test the ignition and shutoff features by manually closing the fuel gas valves to simulate a flame failure condition. Within four seconds of flame failure, the unit will try to relight for the preset number of times and then shut down, locking out the BMS. Retest the unit s FLAME ON and NO FLAME voltage readings using the procedures described on p. 7 of this manual. Once a year remove the assembly and inspect the condition of the flame sensor and ignition wire for excessive corrosion and carbon buildup. Ensure that the orifices in the pilot tip are clear of any particulate as well. All seams and seals around the flame arrester and igniter body should be free of cracks or holes that might allow a flame to escape. If any of these conditions are found, the element should be cleaned or replaced prior to returning to service. Inspect, clean and replace all components as required. Reassemble the unit and test after inspection and maintenance. Combustex offers a service kit for the Pilot Pro 900 complete with 1 year recommended spare parts. This package contains the following items: # 4 - Spark Rod (P/N 1384) # 9 - Ignition Module (P/N 1409) # 11 - Ignition Wire (P/N 1416)

9 of 10

10of 10 The Canalta, Combustex Burner Ignition & Control Systems and Pilot Pro names and logos are trademarks of Canalta Controls Ltd. All other trademarks are the property of their respective owners. Due to Canalta s commitment to quality and innovation, all product designs, specifications and information materials, including the contents of this publication, are subject to change without notice. Responsibility for the proper selection, maintenance and use of any product remains with the customer. SAFETY FIRST. 2011-2015 Canalta Controls Ltd. All rights reserved. Unauthorized reproduction in whole or in part is prohibited.