TDK Lambda TEP INSTRUCTION MANUAL

Similar documents
EVS RP6020. Instruction Manual

RP Instruction Manual

HWS 15A-150A Series. Instruction Manual

LS200 Series Instruction Manual

DRB-1 Series Instruction Manual

ZWS-BAF Series. Instruction Manual. TDK-Lambda. ZWS-BAF Series Instruction Manual A H

ZWS-BP Series. Instruction Manual. TDK-Lambda. ZWS-BP Series. Instruction Manual A C

PFE700SA Series Instruction Manual

DRL-1 Series Instruction Manual

PFE1000FA Series. Instruction Manual

ZWD100PAF Series Instruction Manual

ZWD225PAF Series Instruction Manual

CN100A110 SERIES Instruction Manual

CCG Series Instruction Manual

Instruction Manual PFE500F 1000F SERIES. TDK-Lambda PFE500F 1000F Series INSTRUCTION MANUAL

PAF500F24 SERIES Instruction Manual

PAF F280 SERIES Instruction Manual

Instruction Manual. TDK-Lambda. PFE300SA 500SA Series INSTRUCTION MANUAL

HWS Series Instruction Manual

CN-A110 SERIES Instruction Manual

PAF SERIES. Features. Model naming method PAF 500 F / Conformity to RoHS Directive. Applications. Product Line up. DC/DC Module 400W-700W PAF

PAF F48 SERIES Instruction Manual

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

2W, Low Cost DIP, Dual Output DC/DC Converters

Basic Characteristics Data

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-480 Series, 480W

Basic Characteristics Data

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

Basic Characteristics Data

Basic Characteristics Data

PRODUCT SPECIFICATION File: EA-520H1U-01 Date: Apr., 7, 2005

Basic Characteristics Data

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

*Last time buy date of PAH200H: Mar. 29, *Last time buy date of PAH50S, 75S, 100S, 150S, 200S: Dec. 2, PAH450S PAH75D

Basic Characteristics Data

HEAVY DUTY POWER RELAYS FEATURES

1. DBS series. Applications Manual

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

(typ.) (Range) ±18 330# 89 MPW MPW

Basic Characteristics Data

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

RSS Series Panel Mount Solid State Relays. 4,000 RMS (minute)

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

PRODUCT SPECIFICATION File: EA-250U1C-10 Date: May, 25, 2005

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Basic Characteristics Data

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

Basic Characteristics Data

Filterpack FR-BFP2-(H)0.4K to (H)15K

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

PRODUCT SPECIFICATION File: EA-400H2U-02 Date: Feb., 16, 2005

MYPMA01218RCF-CAB Non-isolated type

18091-PS. Preliminary General Specification PSM (AC) PES REV: PAGE. 1 of 8

(DC/DC) SERIES to 96.5% (typical) Product Lineup. Ordering Information. Features. General Description. Super high efficiency

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

Applications Manual of DPG serises

Technical Information Solid State Relays. Glossary. Solid State Relays

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

LESTRONIC II BATTERY CHARGER MODEL 07210

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

XLR Energy Storage Module

Pressure sensor with built-in amplification and temperature compensation circuit

Basic Characteristics Data

1-50 KVA SINGLE-PHASE SERVO REGULATOR INSTRUCTIONS FOR USE SERVO SINGLE-PHASE VOLTAGE REGULATOR

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

1 Terminal Block A-22

MODEL ELC-12/60-D BATTERY CHARGER

EZA2500 Series. TDK-Lambda. EZA2500 Series INSTRUCTION MANUAL V C

Power Supply Technical Information

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

MODEL ELC-12/40-CVM-D BATTERY CHARGER

PRODUCT SPECIFICATION File: EA- 400ET1-10 Date: Jul., 28, 2006

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)

Model Number Structure

TECHNICAL DATA Troubleshooting Tips for DC to DC Converter

Model Number Structure

Basic Characteristics Data

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

XLM 62V Energy Storage Module

PG02S Series 2W DC/DC CONVERTER, SIP-Package

Features. Description. Table of Contents

PRODUCT SPECIFICATION File: EA-600ETF-C10 Date: Mar. 29, 2010

DH50 SERIES. DATASHEET Rev. A

Hinged Safety Door Switch

Basic Characteristics Data

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Transcription:

BEFORE USING THE POWER SUPPLY UNIT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard. DANGER Never use this product in locations where flammable gas or ignitable substances are present. There are risks of igniting these substances and exploding by an arcing. INSTALLATION WARNING When installing, ensure that work is done in accordance with the instruction manual. When installation is improper, there is risk of electric shock and fire. Installation shall be done by Service personnel with necessary and appropriate technical training and experience. There is a risk of electric shock and fire. Do not cover the product with cloth or paper etc. Do not place anything flammable around. This might cause damage, electric shock or fire. WARNING on USE Do not touch this product or its internal components while circuit is live, or shortly after shutdown. There may be high voltage or high temperature present and you may receive an electric shock or burn. While this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation. For products with no cover, do not touch them as there are high voltage and high temperature parts inside. Touching them might cause injury such as electric shock or burn. There are cases where high voltage charge remains inside the product. Therefore, do not touch even if they are not in operation as you might get injured due to high voltage and high temperature. You might also get electric shock or burn. Do not make unauthorized changes to this product nor remove the cover as you might get an electric shock or might damage the product. We will not be held responsible after the product has been modified, changed or dis assembled. Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. Please stop using it immediately and shut off the product. It might lead to fire and electric shock. In such cases, please contact us. Do not attempt repair by yourself, as it is dangerous for the user. Do not operate and store these products in environments where condensation occurs due to moisture and humidity. It might lead fire and electric shock. Do not drop or apply shock to this product. It might cause failure. Do not operate these products mechanical stress is applied. CAUTION on MOUNTING Confirm connections to input/output terminals are correct as indicated in the instruction manual before switching on. Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within specifications, otherwise the product will be damaged. Input line, please use the wires as short and thick as possible. Do not use this product in special environment with strong electromagnetic field, corrosive gas or conductive substances and direct sunlight, or places where product is exposed to water or rain. Mount this product properly in accordance with the instruction manual, mounting direction and shall be properly be ventilated. Please shut down the input when connecting input and output of the product. CAUTION on USE Product individual notes are shown in the instruction manual. If there is any difference with common notes individual notes shall have priority. Before using this product, be sure to read the catalog and instruction manual. There is risk of electric shock or damage to the product or fire due to improper use. Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within specifications, otherwise the product will be damaged, or cause electric shock or fire. If the built in fuse is blown, do not use the product even after replacing the fuse as there is risk of abnormality inside. Be sure to request repair to our company. For products without built in protection circuit (element, fuse, etc.), insert fuse at the input to prevent smoke, fire during abnormal operation. As for products with built in protection circuit, depending on usage conditions, built in protection circuit might not work. It is recommended to provide separate proper protection circuit. For externally mounted fuse do not use other fuses aside from our specified and recommended fuse. When used in environments with strong electromagnetic field, there is possibility of product damage due to malfunction. When used in environment with corrosive gas (hydrogen sulfide, sulfur dioxide, etc.), there is possibility that they might penetrate the product and lead to failure. When used in environments where there is conductive foreign matter or dust, there is possibility of product failure or malfunction. Provide countermeasure for prevention of lightning surge voltage as there is risk of damage due to abnormal voltage. Connect together the frame ground terminal of the product and the ground terminal of the equipment for safety and noise reduction. If the ground is not connected together, there is risk of electric shock. Parts with lifetime specifications (built in fan electrolytic capacitor) are required to be replaced periodically. Set the overhaul period depending on the environment of usage and perform maintenance. Take care not to apply external abnormal voltage to the output. Especially, applying reverse voltage or overvoltage more than the rated voltage to the out put might cause failure, electric shock or fire. <Page> 1/12 B094 04 01B

1. Model name identification method TEP 200 280 / Option (*1) (*1) Blank:With cover type. (Standard) Rated Output Voltage Output Power (W) Series Name 2. Terminal Explanation 1 2 +V : + Output terminal (+280V) V : Output terminal(0v) 3 4 5 6 7 Safety Earth Terminal: (Provided both Input side and Output side) +Vin : Input terminal :Connect to PV+ Vin : Input terminal: Connect to PV Power On SMD Green LED When output is normal, Green LED is ON When output is shut Down, LED is OFF Power Fail signal (Open collector when power Fail) (5045 02A: Molex) The signal L level is depends on circuit external. The maximum sink current is 2mA. 20Vmax. *Screw Terminals: F4121C S 9602 (FUJICON) sized M4 * Connector (MOLEX) for Power Fail Signal Vertical Header(CN51) Housing Crimp Terminal 5045 02A 51191 0200 50802 Hand Crimping Tool: 63811 5200(MOLEX),11 26 0023(MOLEX) or equivalent. Use recommended crimping tool and wire. Matching housing and terminal pin Not included with the product. ( 1, 2 )( 3 )( 4, 5 ) ( 7 ) are basic isolated each other. <Page> 2/12

3. Connecting method Pay attention to the input wiring. If it is connected to wrong terminal, the power supply will be damaged. TDK Lambda Input must be NOT Live when making connections. Connect terminal (2 terminals) to Safety Earth (frame ground of the equipment etc.) by thick wire for safety and improvement of noise reduction. Intend to be used Factory wiring only. Use isolated Ring Terminal for wiring. For safety purpose. Do NOT stress on PCB when wiring. The surface mounted device might be damaged. Recommended torque : 1.2N m(12.2kgf cm) Max <Page> 3/12

4. Explanation of Functions and Precautions 4 1. Input Voltage Range Input voltage range is 300 1000VDC. Input voltage, which is out of specification, might lead unit damage. TEP allow temporary overvoltage up to 1060V duration 1 second. Between Input+ and Input, leaded MOV (B72225S4751K1 EPCOS) fitted after input Fuse. TEP is surge tested with external SPD (STP1000YPVM Mersen) on input terminal. 4 2. Output Voltage Output voltage is set to the rated value at shipment. No output voltage adjustment available. 4 3. Inrush Current TEP equipped Power thermistor to limit the inrush current. So that higher current will flow at higher ambient temperature or re input condition. Please select input switch and fuse carefully with the high temperature and re input the power condition. Please consider protection coordination as well. The inrush current value in the specification is under cold start at 25. 4 4. Over Voltage Protection (OVP) The OVP function (Inverter shut down method, manual reset type) is provided. OVP function operates within 295 350V When OVP triggers, the output will be shut down. To reset OVP, remove the input of power source for a few minutes, and then re input. In addition, the setting value of OVP is fixed and not adjustable. Pay attention not to apply higher voltage externally to the output terminal to avoid unit failure. In addition, between Vout+ and Vout, leaded MOV(B72210P2321K1 EPCOS) fitted. 4 5. Over Current Protection (OCP) TEP provide over current protection. OCP type is constant current with delay shut down. OCP function operates when the output current exceeds 101% of maximum DC output current of specification. The outputs will be shut off after 250ms of continued OCP condition. To reset shut off, remove the input of power source for a few minutes, and then re input. (Same as OVP reset). OCP setting is fixed and not to be adjusted externally. This function effective at turn on time as well. So that when capacitive load, unit might have start up failure. When output rise, TEP is in over current mode and might shut the output off before output voltage rise. For pure capacitive load, TEP will bear over 800uF. When start up failure, please check the load condition. The recommended load condition are startup with no load with extra capacitor only, wait a few second for reset over current mode then take load by switch control or start up in control off mode on downstream converters. In addition, when the downconverter have PFC, the charging current leads TEP to over current mode. 4 6. Output Ripple & Noise The standard specification for maximum ripple value is measured according to measurement circuit specified by JEITA RC 9131B. When load lines are longer, ripple will becomes larger. In this case, electrolytic capacitor, film capacitor, etc. might be necessary to use across the load terminal. The output ripple cannot be measure accurately if the probe ground lead of oscilloscope is too long. Power Supply +V V Load Coaxial Cable 1.5m 50W R C R:50W C:4700pF Oscilloscope 100MHz <Page> 4/12

4 7. Series Operation TEP designed as NOT intend to use in series operation. 4 8. Parallel Operation TEP output voltage is designed to decline when load is higher. This enables parallel operation for power up by droop method. Use a pair of nearest output voltage units for better power balancing. The balancing is affected by output voltage differences. Also, internal Oring Diode offers protection against external over voltage applied to control point. Parallel use intend to up to 2 units only. Note the total output power should be less than 360W to avoid units shut down. Voltage Control point +Vo + Internal Oring Diode LOAD -Vo - +Vo Internal Oring Diode -Vo 4 9. Isolation Test Isolation test is NOT performed on each unit. The isolation is verified by withstand Voltage test. 4 10.Withstand Voltage TEP is designed to withstand 3.0kVAC between input and output, 3.0kVAC between input and Safety Earth. Output to Safety Earth withstands 2kV. Also input/output to signal 2kVAC. When testing withstand voltage, set current limit of withstand voltage test equipment at 20mA. The applied voltage must be gradually increased from zero to testing value and then gradually decreased for shut down. When timer is used, the power supply may be damaged by high impulse voltage at timer switch on and off. Connect input and output as follows. IN OUT 3kVAC 1min (20mA) IN Safety Earth 3kVAC 1min (20mA) Out Safety Earth 2kVAC 1min (20mA) Signal (IN/OUT) 2kVAC 1min (20mA) Wired Externally IN Safety Earth +Vin -Vin Safety Earth +Vo -Vo PF Signal+ PF Signal- Out Signal Note1: This product has discrete ceramic capacitor in secondary circuit to Safety Earth. Some of the withstand voltage tester may generate high voltage at the matching with ceramic capacitor and may cause the unit damage. So, please check the waveform of test voltage. Note2: In case of testing Earth Continuity test, The Input/Output Earth Terminal must be externally wired. The wire size should satisfy safety requirement. <Page> 5/12

5. Mounting Method 5 1. Mounting Procedure TEP employ safety cover made of policarbornate. To mount TEP PCB, screw the 7 holes first on customer provided isolation stud. The isolation stud should be suitable for required creepage /crearancec. After screw the TEP PCB, fit on the safety cover for safe operation. Cover fitting procedure: (The output upwards) a. Insert cover edge into the slit left side. b. Slide down the cover until fully hook. c. Insert rivet right side (4 points) d. Screw the2 of mount hole (left side) e. Confirm the cover is fully fitted on TEP PCB. Note; For detail, refer to the leaf which attached with Cover and Rivet in the carton box. <Page> 6/12

5 2. Mounting Method (1) TEP is convection cooling type power supply. In the consideration for the heat dissipation and safety, please take a distance more than 50mm for air intake/out go. (2) Please take into consideration for insulation distance (space) more than 16mm from dead metal of enclosure as PCB type power supply(pollution degree 3). The insulated stud must be height minimum 10mm. The screw head for stud is 6.4mm away from circuit inside. Then kept 16mm creepage.the screw head/washer size shoud be less than 6.4mm. (3) The required spacing surround the PCB is 2mm min. Since the PCB edge to circuit kept 6.4mm, air gap 2mm will satisfy safety spacing/creepage. (4) When utilize insulator, please consider 16mm creepage. When mounting, DO NOT stress on PCB. (5) Recommended torque for mounting screw (M3 screw): 0.49 N m (5.0 kgf cm) (6) Protection Cover is in packaged on factory shipment. (See the item of Protection Cover in this section.) 5 3. Output De rating according to the Mounting Directions The Mounting Directions refer to the figures below. Recommend standard mounting is direction (B). Mounting direction (A), (B) and (C) are allowed. Mounting direction (D) is NOT allowed. When the mounting direction is (A), ambient temperature should be 50degC or less. When removing the cover, direction (A), (B) and (C) does NOT required de ratings. However, 80% de rating required for direction (A) with Cover. Mounting Direction 40mm 40mm Output Input 50mm Min Input Output 40mm 50mm Min Input Output 50mm Min 40mm Output Input 50mm Min (A) (B) (C) (D) Standard Mounting Not Possible Note: The Cover height is 41mm max on component side. Component height in component side: 39mm Max PCB thickness 1.6mm. Lead height 2.5mm Max. Cover fixing 10mm. Total height including component lead less than 45mm.(Without cover.) Mount with 9 xφ3.5holes. Use stud with necessary spacing required by Safety instruction.(5.5mm Spacing/16mm creepage for 1000V) Recommended insulated type stud to keep spacing. https://us.schurter.com/bundles/snceschurter/epim/_prodpool_/newds/en/typ_transipillars.pdf http://www.hirosugi.co.jp/products/pom/as B.html https://www.electronicfasteners.com/wp content/uploads/2014/09/linecard_richco.pdf#search=%27richco+standoff%27 <Page> 7/12

Protection Cover ( In packaged on shipment as standard) To avoid electric shock /burning hazard, protection cover is provided. The cover is in packaged on factory shipment. Use cover as standard for safety purpose. The cover height will be 41mm from PCB. The cover is made of flame retardant polycarbonate material t=0.8mm. Coating To avoid electric shock /burning hazard, Coating is provided. The coating protects PCB solder side only by spray coating. The coating material is 1 2577 Dow corning. This does NOT mean Any Warranty for Humidity or Dust proof. <Page> 8/12

Output De rating according to the input Voltage TEP require output power de rating according to input voltage. Refer to figures below. When employ protection cover, the 80% power de rating is required at mounting A only. TDK Lambda Output (W) Output Power De Rating 200W (280V 0.72A) 100W (280V 0.36A) Output VS Input De rating Curve Operation Temperature Range 20Deg C to +60Deg C 300V 450V 1000V Vin Output Power Temperature De Rating 200W Mount A removing Cover. 160W Mount B,C (With Cover./removing Cover.) Mount A With Cover. 20 40 50 60 Ta <Page> 9/12

6. Wiring Method (1) TEP designed as Factory wiring only. No field wiring allowed. (2) The output load line and input line shall be separated, and use all lines as thick and short as possible to make lower impedance. The output load line(+/ ) and input line(+/ ) shall be twisted or use shielded wire to improve noise sensitivity. Also, please pay attention for Voltage/Temperature rating of wire. (3) Noise can be eliminated by attaching a capacitor to the load terminals. (4) The recommended wire type, torque and crimp type terminal : Recommended Wire Recommended crimp type terminal Recommended torque D t Note 1: When using separate loads, use of two pcs. of 0.8mm thick crimp type terminal is recommended. Note 2: For recommended diameter, refer to wire maker recommended allowable current and voltage drop. Mounting piecs (MAX) (MAX) (MAX) Terminal M4 Screws AWG14 22 6.8mm 0.8mm 2 piece 1.0N m (10.2kgf cm) 1.2N m (12.2kgf cm) 7. The life expectancy The life expectancy of the power supply is 5years. The life of the power supply depends on the life of the built in aluminum electrolytic capacitor. The life expectancy is not a guaranteed value, please consider as a reference. Please do not use the product which passed over the life expectancy. There is a risk of unexpected output shutdown and specifications may not be satisfied. Please contact us for maintenance or exchange the product which passed over the life expectancy. <Page> 10/12

8. External Fuse Rating Surge current flows when input turn on. Use slow blow fuse or time lug fuse. Fast blow fuse cannot be used. Fuse rating is specified by inrush current value at input turn on. Do not select the fuse according to actual input current (rms.) values. TEP employs internal fuse as 0508001MXEP (Little Fuse) 1000V1A rated Fast blow/high braking type. Select the fuses which have more surge current capability. Please consider protection coordination for selecting fuses. TDK Lambda 9. Before concluding that the unit is at fault Before concluding that the unit is at fault, make the following checks. (1) Check if the rated input voltage is connected. (2) Check if the wiring of input and output is correct. (3) Check if the wire size is not too thin. (4) Check if the output current and output power does not over specification. (5) Audible noise can be heard when input voltage waveform is not DC. (6) Audible noise can be heard during Dynamic Load operation. (7) Ensure that a large capacitor is not connected on the output side. When large capacitor fitted, due to charging current, OCP might operate. And the OCP duration exceeds 250ms, TEP will shut the output off. 10. Warranty Period Warranty Period applies 5years. Condition: Ambient Temperature 40degC, average load is 80 %( 160W) Do NOT use over warranty period. Regular maintenance recommended. Following cases are not covered by warranty (1) Improper usage like dropping products, applying shock and defects from operation exceeding specification of the unit. (2) Defects resulting from natural disaster (fire, flood etc.) (3) Unauthorized modifications or repair. 11. Safety instruction (Reference Only) TEP is NOT approved by safety. Also, NOT designed to meet full Safety requirement. TEP is a DC DC converter intend to be used with an end product utility interactive inverter intend for pho tovolic input from PV arrays which have maximum Array Short circuit current 3092A. The end product is an isolated type and provides a 440V three phase output with maximum voltage of 254V (L N). TEP have the following characteristics. Open type intend for use in end product enclosure Intend to be used in end product inverter Intend to be used with UL evaluated Galvanic Isolation via Transformer at AC mains Intend to be used with UL evaluated Surge Suppressor on DC input (Rated1000V) Factory wiring only No User Accessible circuits(basic insulation present only between input and output circuits and line circuit to Earth GND) To be evaluated as Recognized Component QIKH2 US Only <Page> 11/12

Typical Application UL Evaluated Impulse Surge Capability: PV side: TEP employ leaded MOV (B72225S4751K1 EPCOS) inside. When required surge capability, please consider at application NOT apply over voltage in TEP PV side. TEP require External SPD(STP1000YPVM Mersen) in PV side. Output side: TEP employ leaded MOV(B72210P2321K1EPCOS). This absorber aim to provide to clamp the surge voltage less than 600V. However, the absorber can NOT clamp the surge voltage when surge current is higher than a tens ampere s. So, when require higher capability of surge, please consider in application NOT exceeding 500V in TEP output. TEP should be tested with condition in customer end products. So, the surge capability should be tested in END products. And NOT TEP alone. END of Instruction Manual. <Page> 12/12