PRE-INSTALLATION GUIDE

Similar documents
User s and Installation Manual

Dry Vacuum System. Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL. Recommend Daily use of Monarch CleanStream

PowerAir Compressor Installation

ClassicSeries Compressor Installation

INSTALLATION and OPERATION INSTRUCTIONS

AirStar Tandem Installation Kit Part Number 85694

Dental Vacuum System. Installation Overview

Installation & Operation

DENTAL AIR SYSTEM. Installation and Operation Manual

Dental Dry Suction. Installation/User Guide

Installation and Operation Manual

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide

INSTRUCTIONS INSTALLATION OF NEMA-3R KIT FOR 43, 44 & 52 FRAME AF-6 DRIVES INTO WELDED ENCLOSURES

Microprocessor Controlled Dental Vacuum System Installation Manual

INSTALLATION GUIDE. Model #GB2 35/50 GPM Grease Interceptor For Indoor Use. Contents

INSTALLATION GUIDE. Model #GB1 20/25 GPM Grease Interceptor For Indoor Use. Contents

PARTS CATALOG EQUIPMENT ACCESSORIES

IMAGING UTILITY ROOM ACCESSORIES

GB2 35/50 GPM Grease Interceptor for Indoor Use

DENTAL AIR SYSTEM. Installation and Operation Manual

Installation Instructions

A-dec 311 Dental Chair and Related Systems

Installation, Operation and Maintenance Manual

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL FRONT LOAD LOBBY UNIT PLAN VIEW FRONT VIEW SIDE VIEW

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

LAWN SPRINKLER, IRRIGATION PUMP

Part Numbers: A1250 and A1350 INSTRUCTION MANUAL

Material required for drilled well application (indoor use only)

A-dec 200 P RE-INSTALLATION GUIDE

215 Gallon Waste Oil Tank With Metering Pump Installation Instructions

330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT. 330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT (30 HEIGHT NOTE SEE W ALL OPENING

HALLMARK INDUSTRIES INC

Priming Systems Installation Instructions


203mm (8") MAXIMUM WALL THICKNESS IN AREA OF UNIT. 203mm (8") MAXIMUM WALL THICKNESS IN AREA OF UNIT (30 HEIGHT NOTE SEE W ALL OPENING

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Self Cleaning Hood System Installation, Operation, and Maintenance Manual

M944T. Soundshield Assembly Instructions

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

VACUUM AIR TUBE mm (4.5") DIA. TUBE SYSTEM OPERATOR UNIT (OVERHEAD DELIVERY) 15160, 15161, OR CUSTOMER UNIT (UNDERGROUND)

Model RM-1 Riser Manifold Commercial and Residential General Description

Active Evacuation System (AES)

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2011

Cabinet and Rack Installation

SHALLOW WELL JET PUMP

Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD

Section 02: Pre-Installation Procedures

55-Gallon Powder Drum Truck

10 Commercial, Industrial, Agricultural Services

Cabinet and Rack Installation


NM650 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...

M673LD3 / M673L3. Soundshield Assembly Instructions. East Coast Branch th Avenue. 15 Aegean Dr. Northwest. Suite 4 Seattle, WA 98107

Reverse Osmosis Systems Section 11 Reverse Osmosis Systems

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04A

Cabinet and Rack Installation

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Installation, Operation and Maintenance Manual

Custom Shipyard and Military Facility Products

M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.08 C M A D I S H M A C H I N E S K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841

PLUMBING PARTS CATALOG

Atomizer 36-DC User Guide

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.03B

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

MODEL TRIMMER. Operating and Maintenance Instructions. Item and

Section. Vacuums. 866-DTE-INFO 147

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

Pre-Installation Guide Performer

70-35-GP Portable CAFS Unit Service Parts List

PowerMax Surgical Suction Producers

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

SuperFlo 9,000 High Volume Pump Product Manual

STAR STOP SHALLOW WELL JET PUMP

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

M843W3. GEM Series Sound Enclosure Assembly Instructions. Gulf Branch th Avenue NW. Southeastern U.S.A W Newport Center Dr

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

INSTALLATION GUIDE. Model #PP1 Pumpout Port Kit For Use with Grease Interceptors Models GB1, GB2 and GB3. Contents

INSTALLATION AND OPERATION MANUAL

Installation Manual. Q Series Quadplex Grinder Systems. Contents

model 2000SN FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS Recessed Wall-Mount Bottle Filling Station

PROPER ELECTRICAL CONNECTIONS

Tools Needed for Mounting Cleá Filling Station

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

Installation, Operation and Maintenance Manual

Automatic Burnout Furnaces 115 to 230-volt Models OPERATOR S MANUAL

MTS-T4-6 APU Warranty SRT Time Guide (Caterpillar/Perkins Engines)

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.05A

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description

BEST PRACTICE CEBP9801. Controls Engineering COE. DATE: May, 1998 Delphi Controls COE Best Practice - Flexible Utility Connections

FCX TECHNICAL BOOKLET

OPTEVA 923 IN LOBBY TELLER (ILT) PLAN mm (60") WIDE PLAN - STAND ALONE FRONT VIEW SIDE VIEW PAGE 1 OF 5 CALL NOTE:

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions

DWV PVC DWV Drain Waste Vent Fittings

PRE-PLUMBED SEWAGE SYSTEM

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA Tel: Ref.

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

MDT5N25 & MTD5N40 SERVICE PARTS

Medium Voltage Induction Motors. 21-L Series New High Efficiency Design for High Capacity Applications 450 kw 18,500 kw (600 HP 25,000 HP)

Transcription:

Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 PRE-INSTALLATION GUIDE All pumps comply with NFPA 99C level 3 requirements. All installations must conform to local codes. System being installed: (AS CHECKED) q V3 q V5 q V7 q 2V3 q 2V3CT q 2V5 q 2V5CT q 2V7 q 3V5 q 4V5 Doctor: Address: Phone#: Dealer: Dealer Address:

MOJAVE SYSTEM CONFIGURATIONS System Components V3 V5 V7 2V3 2V3CT 2V5 2V5CT 2V7 3V5 4V5 From Treatment Room Gas/Liquids/ Solids Gas Exhaust to Outside Vent V3 Pump Assembly 1 0 0 2 2 0 0 0 0 0 V5 Pump Assembly 0 1 0 0 0 2 2 0 3 4 V7 Pump Assembly 0 0 1 0 0 0 0 2 0 0 MT10 Separator Tank MT10 / MT12 Tank Assembly 1 1 1 1 0 1 0 0 0 0 CT20 / CT22 Tank Assembly 0 0 0 0 1 0 1 1 1 1 Liquids/Solids Heat Exchanger Master Controller Assembly 1 1 1 1 1 1 1 1 1 1 Maximum Users 3 5 7 6 6 10 10 14 15 20 Sewer Drain Recommended Number of Simultaneous HVE/SE Users Check Valve Gate Valve V3, V5 or V7 Vacuum Pump Typical MOJAVE System Installation V3 V5 V7 2V3 or 2V3CT 2V5 or 2V5CT 2V7 3V5 4V5 HVE SE HVE SE HVE SE HVE SE HVE SE HVE SE HVE SE HVE SE 3 + 0 5 + 0 7 + 0 6 + 0 10 + 0 14 + 0 15 + 0 20 + 0 2 + 2 4 + 2 6 + 2 5 + 2 9 + 2 13 + 2 14 + 2 18 + 4 0 + 6 2 + 6 5 + 4 3 + 6 7 + 6 12 + 4 12 + 6 13 + 14 0 + 10 4 + 6 1 + 10 5 + 10 9 + 10 9 + 12 10 + 20 Note: 1 HVE = 2 SE s 1 HVE = 2 Nitrous Scavengers 0 + 14 0 + 12 3 + 14 6 + 16 6 + 18 8 + 24 1 + 18 2 + 24 2 + 26 5 + 30 0 + 20 0 + 28 0 + 30 0 + 40 Master Controller Assembly MT10 / MT12 10 Gallon Physical Characteristics Tanks Typical V3, V5 or V7 System Pump Configurations CT20 / CT22 Continuum MT10 / MT12 Tank Stacked onto One V3, V5 or V7 Pump One V3, V5 or V7 Pump Two V3, V5 or V7 Pumps Stacked Three V5 Pumps Stacked Width 13.5 in. (34 cm) 29 in. (74 cm) 25 in. (64 cm) 29 in. (74 cm) 25 in. (64 cm) 25 in. (64 cm) 25 in. (64 cm) Depth 3 in. (8 cm) 22 in. (56 cm) 23 in. (58 cm) 23 in. (58 cm) 21 in. (53 cm) 21 in. (53 cm) 21 in. (53 cm) Height 11 in. (28 cm) 33 in. (84 cm) 50 in. (127 cm) 50 in. (127 cm) 17 in. (43 cm) 34 in. (86 cm) 51 in. (130 cm) Weight 13 Lbs. (6 kg) 75 Lbs. (34 kg) 150 Lbs. (68 kg) 220 Lbs. (100 kg) 145 Lbs. (66 kg) 290 Lbs. (132 kg) 435 Lbs. (197 kg)

ASSEMBLY DIMENSIONS 13.5 in. (34 cm) 3 in. (8 cm) 11 in. (28 cm) Important: The Master Controller is mounted on the front of the MT10 / MT12 or CT20 / CT22 tank chassis. Never stack a CT20 /CT22 Tank on top of any Pump. Never stack a Pump on top of any Tank. Recommend pumps only be stacked a maximum of two high. All units shipped with all leveling feet set to lowest position. 10 in. (24 cm) 11 in. (28 cm) 23 in. (58 cm) 29 in. (74 cm) Master Controller Assembly Dimensions 23 in. (58 cm) 22 in. (56 cm) 25 in. (64 cm) 21 in. (53 cm) 17.5 in. (44 cm) 25 in. (64 cm) 33 in. (84 cm) 42 in. (107 cm) 17 in. (43 cm) MT10 / MT12 10 Gallon Tank Dimensions V3, V5 and V7 Vacuum Pump Dimensions CT20 / CT22 Continuum Tank Dimensions 23 in. (58 cm) 50 in. (127 cm) 34 in. (86 cm) 33 in. (84 cm) 2V3 or 2V5 System Installation Recommended Stacked Pumps with Tank on Side 50 in. (127 cm) V3, V5 and V7 System Dimensions 34 in. (86 cm) 2V7, 2V3CT or 2V5CT System Installation Recommended Stacked Pumps with CT20 / CT22 Tank on Side

SUB FLOOR INSTALLATION - Recommended system installation layout should be used whenever possible. Ceiling 1/2 - Inch Diameter Riser Minimum Slope: 1/4 inch per 10 Feet MAIN LINE See Notes 2, 3 & 4. Junction Box See Note 2. TREATMENT ROOM PLUMBING INSTALLATIONS Interior Wall Sub Floor Riser Connection See B. Main Line Turn Connection See A. Notes: 1. 10-foot Maximum Height from Main Line to Tank. 2. Consult Dental Unit Manufacturer's Guidelines for correct reduced size and height of termination of vacuum line inside junction box. 3. Limit branches. Orient main line under junction box or cabinet. 4. When piping line is above 3/4" I.D. or larger, use 45 Y's & elbows only. 5. Recommend installing separate line connection for scavenger when using Nitrous scavengers in overhead piping installations. Main Line Riser for connection to tank input. See Note 1. OVERHEAD INSTALLATION - Alternate system installation layout should be used only when unable to use the sub-floor plumbing layout. Minimum Slope: 1/4 inch per 10 Feet Interior Wall 1/2-Inch Diameter Riser 10-FT Maximum Height from Riser Trap to Main Line CONNECTOR DETAILS - ALL INSTALLATIONS Ceiling Junction Box See Note 2. Riser Trap See D. Overhead Riser See C. MAIN LINE See Notes 2, 3 4 & 5. q q q q Use only 45 elbows to make turns in main line. Make sure to use the proper pipe type for associated system. If piping is diverted to clear an obstruction, DO NOT MAKE A TRAP. See detail A, Main Line Turn Connections. DO NOT use standard 90 elbows. Important: All installation pipes and fittings provided by plumber. All installations must conform to local codes. A B C D 45 Elbow Clearing & Obstruction Making Turns 45 Elbow 45 ELL Main Line To Dental Unit Junction Box 1/2 Inch Riser 45 Y To Tank 45 Elbow Main Line 1" Min 45 Elbow 1/2 Inch Riser 1/2 Inch Diameter 45 Y To Tank 1/2-Inch Riser To Main Line 1/2-Inch To Dental Unit Junction Box Main Line Turn Connections Sub Floor Riser to Main Line Detail Overhead Riser to Main Line Detail (Prevents liquids from draining down the 1/2 riser.) Riser Trap Detail (45 Elbows)

TYPICAL EQUIPMENT ROOM FLOOR PLAN LAYOUT 48" D E 12" 4" 4" 20" Sewer Drain C 62" F 24" 4" MT10 or CT20 Tank B 76" G A 12" H 1" Single or Stacked Pumps (V3, V5 or V7) 4" 24" Single or Stacked Pumps (V3, V5 or V7) A J Pump/Tank Connection Manifold 4" 80" K 23" 1 Closed Vented Drain OR 2 3 2 Inch Exhaust Inch for Top Pump Connection Top 3 Inch 45 Y 2 Inch Pipe for Addition of Exhaust Vent Assembly. See Note c. Open Drain Pipe 2 Inch Pipe for Addition of Exhaust Vent Assembly. See Note c. Notes: See Installation Note J below for required pipe material. a. All piping and fittings must be 4-inch instead of 3-inch when preparing the site for a 3 pump installation. b. Use a second dual 45 Y fitting configuration when preparing the site for a 4-pump installation. INSTALLATION NOTES: 107" c. Pipe required for the installation of the Exhaust Vent Assembly supplied with each pump. See exhaust ventilation requirements provided on the back cover. A. PUMP INSTALLATION SPACE - Area for stacked or side by side pump installation. Keep 4 inch space from walls. Only stack up to 2 pumps in one area. B. TANK INSTALLATION SPACE - Area for typical side by side tank installation. Keep 4 inch space from walls. Never install the CT20 / CT22 tank on top of a pump. C. SEWER DRAIN - Provide a drain for the removal of waste liquids from the MOJAVE tank. Use an open drain pipe (1 ½ inch P-Trap with 1 inch air gap or floor sink) or a closed vented drain. See detail 1. D. TANK WASHOUT - Provide a water source terminated with a ½ inch FNPT shut-off valve providing water pressure between 20 and 100 psi for daily tank washout. Valve location must be no more than 10 feet from the tank installation to allow connection of supplied 10-foot 3/8-inch Poly tubing to the tank washout port. Provisions for backflow prevention may be required. Check local code requirements. E. MASTER CONTROLLER ELECTRIC OUTLET - Master Controller requires a dedicated standalone 120V, 5 AMP or 220V, 5 AMP grounded receptacle. F. PUMP ELECTRIC SERVICE - Each Mojave pump is wired directly with a dedicated 220V, 20 AMP, single phase 60 Hz circuit. If Main Circuit panel is not located in equipment room, a disconnect box with approved ground is needed for each pump. Disconnect boxes should be mounted no more than 3 feet of each other and 3 feet of installation center line. G. SUB FLOOR INSTALLATION VACUUM LINE - See Plumbing Requirements for connection to tank input via supplied hose. H. OVERHEAD INSTALLATION VACUUM LINE - See Plumbing Requirements for connection to tank input via supplied hose. J. HEAT EXHAUST - See Plumbing Requirements for the exhaust vent line required for specific Mojave configurations. Use metal pipe on systems whenever the Heat Exchanger is removed. Schedule 40 pipe can normally be used on typical Mojave configuration installations with a Heat Exchanger. When installing two pumps, a reducing Y adapter (shown by detail 2 above) is needed to connect both vent tubes to a common 3-inch exhaust vent line. K. PUMP/TANK MANIFOLD - User fabricated to connect 3 or 4 pumps to a tank. Used with 3V5 and 4V5 systems. See Pump/Tank Connection Manifold.

SITE REQUIREMENTS Electrical V3 & V5 V7 2V3 & 2V3CT 2V5 & 2V5CT 2V7 3V5 4V5 Master Controller Voltage Rating Volts AC All pumps 220 Volts Single Phase AC, 50/60 Hz 120 / 220 Voltage Minimum/Maximum Wire Size AWG Minimum Gauge Minimum Circuit Breaker Rating Incoming Power Remote (Low Voltage Wiring) (Qty 1) #10 AWG (Qty 1) (Qty 2) 198/242 Volts AC All pumps (Qty 2) #10 AWG (Qty 2) (Qty 3) (Qty 4) 108/132 Volts AC or 198/242 Volts AC #14 AWG 20A 30A 20A (Qty 2) 20A (Qty 2) 30A (Qty 2) 20A (Qty 3) 20A (Qty 4) 15A Hard wire Connection (Each pump is supplied a 6 foot BX cable) #18 AWG (Qty 4) Wire Connection between the MMC and the Remote Switch Panel. NEMA 5-15R for 120V NEMA 6-15R for 220V (Supplied 10-ft. line cord) Plumbing V3 V5 V7 2V3 & 2V3CT 2V5 & 2V5CT 2V7 3V5 4V5 Exhaust Vent Pipe Using Heat Exchanger One 4 or three 2 PVC Two 3 or four Exhaust Vent Pipe Not Using Heat Exchanger (See note 1) One 4 or three Two 3 or four Minimum Suction Line Pipe 1 PVC 1 1 3 PVC 3 PVC 3 PVC Maximum Suction Line Pipe (See note 2) 1 2 2 4 PVC 4 PVC 4 PVC Riser Pipe Vacuum Line Termination 1 ½ FNPT 1 ½ FNPT 2 FNPT 2 FNPT 2 FNPT 2 FNPT 2 FNPT 2 FNPT Branch Line Pipe Size requirement of Branch piping differs by the number of operatories being serviced. Up to two operatories use 1" PVC Schedule 40. Three to six operatories use 1 Schedule 40. More that six operatories use 2" PVC Schedule 40 Drain Line Pipe 1 Schedule 40 Wash-Out Water Line ½ FNPT Shut-off Valve NOTES 1. Recommended for all new installations. 2. Use maximum internal diameter for the main line when preparing any new installation.

PUMP/TANK CONNECTION MANIFOLD Pump/Tank Connection Manifold Using Accessory Kit Sanitary Tee with 1-1/2 FNPT End Fitting. 3 or 4 depending on system configuration. (Supplied by Plumber) Air ow Fl 3 PVC or Copper Tubing & Elbow (Supplied by Plumber) 3 PVC or Copper Clean-out Plug Used with P/N MIK4 (Supplied by Plumber) Check Valve Installed Flat Side Facing Up Horizontal to Floor 3 or 4 Supplied Check Valves See Kit P/N MIK4 or Copper Tubing for Tank Hose (Supplied by Plumber) 1.5 ft Compression Gasket Connector to Pump 1 ft Swivel Elbow 1/4-inch Vacuum Sample Port to Master Controller 3/4 FNPT Reducing Bushing CustomerSupplied Tee Connector 6-inch Riser Hose Between Manifold and CT20 / CT22 Tank Secured by Flexible Couplers 1-1/2 FNPT to Sanitary Tee Check Valve Side View Note: Hang using at least 3 pipe supports supplied by Plumber. CT20 TANK INLET CONNECTION DETAIL Flat Side Installed Facing Up Hoses From Manifold To Pumps Hose Between Manifold and CT20 / CT22 Tank Secured by Flexible Couplers Hoses From Manifold To Pumps 2 Pipe for connection to Facility Piping from Operatory. 2 Flexible Coupling Connector V3, V5 & V7 PUMP HOSE CONNECTION DETAIL ED CL A S S IF I MEDICAL ELECTRICAL EQUIPMENT Hose from Manifold Connected to Pump via Air Input Filter Gasket Connector WITH RESPECT TO ELECTRICAL SHOCK, FIRE, MECHANICAL AND OTHER SPECIFIED HAZARDS ONLY IN ACCORDANCE WITH UL-60601-1, CAN/CSA C22.2 NO.601.1 66CA

EXHAUST VENTILATION REQUIREMENTS HEAT EXHAUST CONNECTION NOTES 1. VENT LINE - The exhaust vent line required for MOJAVE systems using the Heat Exchanger and systems with the Heat Exchanger removed have different requirements. Use metal pipe on systems without a Heat Exchanger while PVC Schedule 40 pipe can be used on systems with a Heat Exchanger. Do not make a trap in the exhaust vent piping. Do not use 90 ο fittings. Also see Exhaust Vent Protection and Ventilation Requirements below. 2. V3, V5 & V7 PUMP EXHAUST VENT CONNECTION - Connection between the pump and exhaust vent piping is typically made via the supplied 2-inch Black Flex tubing. 3. EXHAUST VENT ASSEMBLY - The supplied assembly must be installed at the lower end of the vent pipe to collect condensation produced during pump operation. The bottom of the Y connector should be located 18 inches from floor. Attach the drain tube to the drip leg quick-connect fitting to allow drainage into floor drain/sink. Typical Flex Tubing See Note 2. 4 Exhaust Vent See Note 1. Exhaust Vent Assembly supplied with Tank Accessory kit. See Detail & Note 3. 18 35 V3,V5 & V7 Pump Heat Exchanger Connection V3 or V5 Pump Top View 2 Flexible Coupler Reducing Bushing Drip Leg Detail View Heat Exchanger Vent Pipe 17-Inch Long Flex Tubing 3/4 MNPT X 1/4 FNPT PVC Bushing 1/4 MNPT X 1/4 Push Elbow Exhaust Vent Protection. If the exhaust piping is venting to the outside of the building, precautions must be taken to protect the equipment room from weather elements and animal intrusion. This can be accomplished by using one of the three methods shown on the right. Roof-Mounted Outside Vent Protection Screen Shroud & Screen Shroud & Screen Wall-Mounted Outside Vent Protection Exhaust Vent Requirements. The MOJAVE equipment must be used in a controlled-temperature environment. Maintain equipment room temperature between 40 and 105 degrees Fahrenheit. An exhaust fan is necessary if room temperature is not maintained by other methods. Adequate forced ventilation must be provided across the unit by placing an appropriate exhaust fan opposite an equivalent air intake vent. The fan should be placed higher than the associated intake vent. Recommended minimum exhaust fan requirements for each MOJAVE unit are listed to the right. MOJAVE Unit Watts (Idle) Watts (Max) BTU/Hr (Idle) BTU/Hr (Max) V3 886 1,601 3,021 5,462 V5 886 2,245 3,021 7,660 V7 1,200 2,245 3,021 7,660 2V3 & 2V3CT 886 3,202 6,042 10,924 2V5 & 2V5CT 886 4,490 6,042 15,320 2V7 See Note 1,200 4,490 6,042 15,320 3V5 886 6,735 9,063 22,980 4V5 886 8,980 12,084 30,640 Note: Only 1 pump is running when operating in idle mode. Corporate Headquarters 1295 Walt Whitman Road Melville, New York 11747-3062 Phone: 800-247-8324 Fax: 888-247-8481 www.airtechniques.com MOJAVE is a trademark of Air Techniques, Inc. Air Techniques, Inc. P/N H5187, Rev. M February 2018