Model SL-12K-A SCISSOR LIFT. wheel alignment model. (11000 LBS / 5000Kg Capacity) INSTALLATION & OPERATION INSTRUCTION (SECOND EDITION)

Similar documents
Model FP14KO-A Wheel alignment & Open Front Four-Post Lift

CONTENTS. Product Features and Specifications Installation Requirement Installation Exploded View Operation Instruction...

30-SS1203A 12,000 LB CAPACITY SCISSOR ALIGNMENT LIFT INSTALLATION AND SERVICE MANUAL P/N:

ATTENTION. 1. Do not attempt to use the power unit to extend your cylinder. This must be done manually.

Read this entire manual before operation begins.

Read this entire manual before operation begins.

Read this entire manual before operation begins.

Installation/Operation/Service Manual

CONTENTS. Product Features and Specifications Installation Requirement Steps of Installation 4. Exploded View Test Run...

CONTENTS. Product Features and Specifications...1. Installation Requirement Steps of Installation.. 5. Exploded View Test Run...

Models: SURFACE MOUNTED FOUR-POST LIFTS INSTALLATION AND OPERATION MANUAL

Models PR-12F PR-12C PR-15C SURFACE MOUNTED TWO-POST LIFTS INSTALLATION AND OPERATION MANUAL

CONTENTS. Product Features and Specifications...1. Installation Requirement...3. Steps of Installation...4. Exploded View Test Run...

Model FP12K-K Flat Deck Four-Post Lift

Read this entire manual before operation begins.

ASSEMBLY & OPERATION INSTRUCTION MANUAL

Atlas PV-9WP Addendum

GLO-8000 SERIES (GLO-8000 & GLO-8000XLT)

CONTENTS. Product Features and Specifications...1. Installation Requirement Steps of Installation.. 5. Exploded View Test Run...

Read this entire manual before operation begins.

Jema Autolifte A/S. Manual Release INSTALLTION, OPERATION AND MAINTENANCE MANUAL JA3500F ORIGINAL FOUR POST LIFT. Capacity: 3500KG

Model FP14KA-C Alignment Four-Post Lift

Installation Instructions X-Force UTV Lift (000 Series) Capacity 2,275 lbs (1,035 kg)

GLO-7000 SERIES (GLO-7000 & GLO-7000XLT)

WHIP INDUSTRIES, INC.

Read this entire manual before operation begins.

USE AND MAINTENANCE MANUAL

Operation Manual & Instruction

TWO POST LIFT. Operation Manual & Instruction STRONGMAN TOOLS LTD

Model PL-7 / PL-7X AUTOMOBILE STACKER INSTALLATION AND OPERATION MANUAL

ATD-4P14CCA 14,000 lb Capacity Closed Front Alignment Lift ASSEMBLY & OPERATION INSTRUCTION MANUAL

Index. 1. Important safety instructions Overview of the lift Installation instructions Operation instructions 8-9

Read this entire manual before operation begins.

Installation Instructions Capacity 10,000 lbs. (100 Series Lift)

Read this entire manual before operation begins.

INSTALLATION and OPERATION MANUAL

TP15KC-KX Two-Post Clear Floor Lift

Twin Power. Manual. Pneumatic Multiturn actuator in Standard and ATEX design WARNING! WARNING! Mounting. Assembly example

Hand Pallet Truck NC. Operation Manual

Suzuki Samurai 6.5 Transfer Case Gear Kit, KIT

Read this entire manual before operation begins.

Ford Meter Box Test Bench Installation Instructions

MR6K-48X. Mid-Rise Scissor Lift ASSEMBLY & OPERATION INSTRUCTION MANUAL. 6,000 lbs.

MAGNAGLIDE AIR OPERATOR VERTICAL MOUNT

Installation Instructions Capacity 10,000 lbs. DP10 (200 Series Lift)

Installation Instructions

4QJY4.0-C & 4QJY4.0-C1 four post parking lift. Manual

Southwest Windpower Instruction Sheet AIR-X Circuit Replacement Kit

BMK-18 U.S. Patent #5,298,158

TOYOTA HIGHLANDER RUNNING BOARD HIGHLANDER HV Preparation

ESCO EQUIPMENT SUPPLY COMPANY FORKLIFT JACK. Instruction Manual. Forklift Jack

ATD-2P9A 9,000 lbs. Two Post Clear Floor Lift Owner s Manual

HYDRAULIC TROLLEY JACK K Distributed by Kincrome Tools and Equipment:

INSTALLATION & OPERATION MANUAL

Throttling Pendulum Gate O-ring Replacement Procedure Rev. A, May 2012

INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION MANUAL. HydroPort EXTREME. 915 W. Blue Starr Dr. Claremore, OK (918)

Part# JL AIR IT UP 4 Tire On Board Air Delivery System. (Requires External Air Source)

Two Post Surface Mounted Lift 12,000 LBS. CAPACITY 3000 LBS. PER ARM

INSTALLATION MANUAL. Table of Contents

OPERATION INSTRUCTIONS GFA-W-150\300\500\1000

Floor Plate Style Lift And Overhead Beam Style Lift. Two Post Lift

Mobile Column Lift Set

Remove the 3-11mm nuts holding mirror on. Don t drop the nuts!

Installation and Service Manual

SPO15, SPO18 I N S T A L L A T I O N I N S T R U C T I O N S

Model 2300DL Installation Guide

70 Series 8700 Coupler 2-pc Hub & Shaft Three Phase Brake Instructions IP43 & IP56 (NEMA 2 & 4) Housing

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

10K ALL-IN-ONE 2 POST V-SERIES 42010DSA 42010VSA

INSTALLATION MANUAL & OPERATION INSTRUCTIONS. OVERHEAD CAR LIFT 2-POST LIFT AUTO HOIST APlusLift HW-10KOH

PNEUMATIC SLIDING VALVE

Distributed by Kincrome Group

L DODGE CUMMINS BD FLOWMAX LIFT PUMP KIT

Part No amatic 350

IN-GROUND POOL COVER INSTALLATION GUIDE

RUNWAY SCISSOR LIFT. SURFACE AND FLUSH MOUNTED LIFT (0000 SERIES) 14,000 lb. Capacity (7,000 lbs. per axle) INSTALLATION INSTRUCTIONS

WARNING NOTICE CAUTION ASSEMBLY INSTRUCTIONS

2005 Toyota RAV AUTOMATIC TRANSMISSIONS U240E & U241E Overhaul

Distributed by Kincrome Group

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Chrysler TorqueFlite Shift Improver Kit Part No A-727 (V-8) A-904 (V-8) (A-998 & A-999)

Signet 2517 Brass Paddlewheel Flow Sensor * *

Property of American Airlines

OPERATION AND PARTS MANUAL

SL15/20-6 AND SL15/20-10 INSTALLATION INSTRUCTIONS

KIT No , and 80590

Model Q4P12E and Q4P12X

70 Series 8700 End Mount Three Phase Brake Instructions IP43 (NEMA 2) Housing

INSTALLATION and OPERATION MANUAL

PRSalpha Air Drill (Double Valve)

USE AND MAINTENANCE MANUAL SCISSOR LIFT FOR ALIGNMENT STD-8035

Installation Instructions Shifter Improver Kit Fits:1988 and Later TurboHydramatic 400, TH-400/TH-475 (3L80/3L80-HD) Catalog # 20261

Torqueflite Manual/Automatic Valve Body

Z-Gate Universal Shifter

INSTALLATION AND OPERATION MANUAL 9,000 POUND CAPACITY COMMERCIAL GRADE FOUR-POST LIFTS

EE 6435S, 6435A, 6435B Electrical Release FOUR POST LIFT with PD

Purging Air From Divider Block Lubrication Systems

Service manual Be-Ge 3000

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

Transcription:

Model SL-12K-A SCISSOR LIFT wheel alignment model (11000 LBS / 5000Kg Capacity) INSTALLATION & OPERATION INSTRUCTION (SECOND EDITION) 2007. 6.

CONTENTS Chapter 1 Introduction & Specifications --------------------------------------- page 3 Chapter 2 Packing list ------------------------------------------------------------- page 4 Chapter 3 Installation -------------------------------------------------------------- page 5 Chapter 4 Maintenance ------------------------------------------------------------ page 15 Chapter 5 Trouble shooting ------------------------------------------------------- page 16 Chapter 6 Appendix ---------------------------------------------------------------- page 17 2

INTRODUCTION Model SL-12K-A scissor lift is used in wheel alignment, vehicle checking and maintenance for various types of cars and light trucks. Features: - Superior synchronization in two platforms with graceful out looking. - The movable recesses of the front wheel turntable (optional part) and extra long rear slide plate can be fit for different models of cars. - The pneumatic double-teeth self-locking system and the anti-explosive pipe insurance device works automatically while lowering. The sliding block is made by super-friction materials. SPECIFICATIONS CAPACITY: 5000Kg / 11000 LBS MOTOR POWER: 220V, single phase, 2.2Kw, 10A HYDRAULIC OIL: 10-WT hydraulic oil or Dexron III ATF oil or equals WORKING TEMPERATURE: 5 40 NOISY: 76 db OVERALL LENGTH: 6320 mm OVERALL WIDTH: 2120 mm PLATFORM LENGTH: 5030 mm PLATFORM WIDTH: 635 mm MAX PLATFORM HEIGHT: 1870 mm MIN PLATFORM HEIGHT: 180 mm LIFTING TIME (MAX): 50 sec LOWERING TIME (MAX): 60 sec FIG. 1. 3

Packing Description number Standard parts 1 Oil hose and accessory PACKING LIST Detail information and quantity 1. M16 anchor bolts * 16 sets; M18 anchor bolts * 4 sets; 2. Dia. 6*4 mm air hose * 1 set; Dia. 8*5 mm air hose * 3 meter; 3. 1.5mm wire * 5 meter. 4. Flexible steel hose * 6 meter 5. Limit switch and wire * 1 set 6. High pressure oil hose * 8 pieces. 7. User s manual 8. Dia 14mm combined seal washer * 2 pieces 9. Plastic strip * 10 pcs 10. Air hose connector dia 6, T shape, * 1 pc, 11. Air hose connector dia 6, elbow shape, * 1 pc, 12. Front stop board * 2 pcs, stop board support * 2 pcs 13. Hose cover ( elbow shape) * 1 pair 2 Control cabinet 3 Main platform 1. M16 height adjust bolts * 16 sets; 2. Height shim: 800mm * 2pcs, 150mm*2pcs. 4 Sub platform Same as main platform above 5 Ramp Ramp with exile * 2 pcs, 6 Hose cover 1000mm*3 pcs, 950mm*2 pcs, 750mm*2 pcs TOOLS REQUIRED IN INSTALLATION Rotary hammer drill or similar 3/4 Masonry bit Hammer 4 foot level Open-end wrench set: 7/16 1-1/8 Socket and ratchet set: 7/16 1-1/8 Hex-key / Allen wrench set Medium crescent wrench Medium pipe wrench Crow bar Chalk line Medium flat screwdriver Tape measure: 25 foot minimum Needle nose pliers 4

INSTALLATION IMPORTANT NOTICE These instructions must be followed to insure proper installation and operation of your lift. Failure to comply with these instructions can result in serious bodily harm and void product warranty. Manufacturer will assume no liability for loss or damage of any kind, expressed or implied resulting from improper installation or use of this product. PLEASE READ ENTIRE INSTRUCTION BEFORE STARTING TO ASSEMBLE THE LIFT STEP 1: (Selecting Site) Before installing your new lift, check the following: 1. LIFT LOCATION: Always use architects plans when available. Check layout dimension against floor plan requirements making sure that adequate space is available(see Fig.2). The specified safety distances from walls must be 1000 mm at least. The room ceiling height must be 4000 mm at least also. 2. FLOOR REQUIREMNETS: The lift should be installed on a 3000 PSI concrete with little gradients. Thickness of concrete 150 mm. The leveling of whole area 10 mm. FIG. 2. STEP 2: (Unloading and Unpacking) 1. After unloading the lift, place it near the intended installation location. 2. Remove the shipping bands and packing materials from the unit. 3. Remove the packing brackets and bolts holding the power unit. (Do not discard bolts, they may be used in the assembly of the lift ) STEP 3: (Site Layout) 1. Determine which side will be the approach side. 2. Now determine which side you prefer the power unit to be located on. Note that the power unit can be located on either side. It is helpful to try and locate the power unit with the driver side of the vehicle when it is loaded on the lift to save steps during operation. 3. Once a location is determined, use a carpenter s chalk line to layout a grid for the platform locations. (See Fig.1). Keep all dimensions and square within 1 / 8, otherwise malfunction of the lift will occur. 5

4. Before continuing with the installation it is helpful to get a visual look of the shop and other clearances. Also, this is a good time to drive a vehicle into the position and check for adequate clearance. NOTE All models MUST be installed on 3000PSI concrete only confirming to the minimum requirements. New concrete must be adequately cured by at least 28 days minimum. STEP 4: (Platform installation) 1. Using forklift or crane to move the platforms to the desired location. Note: the turntable recess shall be in the front and the rolling jack wheel notch shall be inside. Note: Put the bottom steel sheet under the frame, holes to holes. 2. Check the distance between the two platforms. The platforms shall be in parallel and the diagonal of the two platforms shall be equal. (Difference less than 5 mm). 3. Using forklift or crane to lift up the platform about 1000 mm as shown in Fig 3. (Hint: Using two floor jacks to lift up the platform in two ends a little then lift the whole platform in the middle. The platform will be rested on the safety ladder) 4. Locate the power unit to the desired position.( Fig 4 & Fig.5) FIG. 3 Main platform Power unit Fig. 4 Sub platform Fig. 5 6

5. Connecting the hydraulic hoses according to Fig. 6 Fig. 6 Hose connection Note: Hose no. 7 and no. 8 has been connected in factory Valve H (with handle) in this position shown is open. 7

Fig 7 Fig. 8 Main cylinder connection (No. 4 and No.5 ). Sub cylinder connection ( No. 6). Assistant cylinder connection (No. 7 for main assistant cylinder No. 8 for sub assistant cylinder) (They are all fixed by manufacturer)., Fig 9 Power unit outlet connection (No. 1 and No. 2) Fig. 10 8

6. Connecting the air hose according to Fig.11 The air hose has been connected to the safety devices on the main and sub platform already. The work in installation is to connect the hose to the power unit. ( Fig 4). Warning: the air supply shall be cut off while connecting. Fig. 11 Fig. 12 (L1/L2 or L3/L4 on platforms) Fig. 13 (elec.-magnetic air valve K) Fig. 14 (Air supply connector for rolling jack ) 9

7. Mount the switch on the inside of the bottom frame of the main platform ( Fig 15) Fig. 15 8. Connecting the cables to the power unit according to Fig. 16 &17 Fig.16 QS: MAIN POWER SWITCH SB0: EMERGINCY BUTTON SB1: LIFT UP BUTTON SB2: LOWER DOWN BUTTON SB3: LOCK BUTTON SQ1: HEIGHT LIMIT SWITCH DQ: AIR VALVE (Position No.111 can be No. 109) 10

Fig. 17 WARNING: While connecting the power cable, cut off the power supply first. STEP 5: (Platform adjustment) 1. platform longitudinal leveling (Rear end) Fig.8 (Front end) Fig.19 Fig.20 11

Using the pipe level will be easy for this work. Fill the pipe with water and attach it to the front end (Fig.19) and rear end (Fig. 20) of the platform. Checking the water level, if needed, screw down the adjusting bolts to lift the platform a little then put some shims under the frame to make the platform level in whole distant. (Fig. 21). Difference <= 5 mm. Note: while inserting the shims under the frame, both sides shall be considered. Fig. 21 2. cross section By using the level (Fig 22) or the pipe level (fig.23), it is easy to level the platform in cross section by inserting the shims under the bottom frame. Difference <= 3 mm. Note: This level work shall be done at both ends for each platform. It is better to check the platform in longitude again after the cross leveling. Fig. 22 Fig.23 STEP 6: (accessory mounting and anchoring) 1. Rear ramps mounting.( Fig. 24) 2. Front stops mounting. (Fg.25) 3. Hose cover mounting (Fig.26) Fig.25 Fig.24 4. Using rotary hammer drill to dig the holes for anchors. Clean the hole then anchor it. Be sure not to move the platform during this work. (Fig.27) Fig. 26 12

Fig.27 WARNING: Before carrying out the following steps, please check again all hoses and cables. Carefully check the power supply ( 220V, 1ph, 20A ) and compressed air supply (6-8 bars). STEP 7: (Platform initializing and leveling) 1. Turn on the main power switch (Fig.28) and compressed air supply valve. Open the cabinet door of the power unit on the back to find the valve H and G. 2. Close the valve H by turn the handle 90 degree to be parallel to the pipe. Open the valve G by counter clockwise turning. (Fig. 29) Fig.28 3. Press the Lift up button on the power unit to raise the main platform to about 1000 mm high.( Fig. 30) (f the platform is already 1000 mm high, please raise it a little more.) 4. Press the Lower down button to lower the main platform to lowest position. (Fig. 31) 5. Press the Lift up button again to raise the main platform to 1400 mm. (Fig.32) Fig. 29 Fig. 30 Fig.31 13

Fig. 32 Fig. 33 6. Open the valve H. Close the valve G.(Fig. 33) 7. Press the lift up button to raise the sub platform to about 1000 mm high.( Fig. 32) (If the platform is already 1000 mm high, please raise it a little more.) 8. Press the lower down button to lower the sub platform to the lowest position ( Fig. 34) 9. Repeat the lifting and lowering of the sub platform Fig. 34 for 6-7 times to get the air out of the cylinders. 10. Then lift the sub platform to the same height of the main platform. Level these two platforms using level or water pipes.( Fig. 35-36) Difference <= 3 mm. 11. Close the valve H. Open the valve G. (Fig. 29) 12. Press the lift up button to raise both platform to Fig. 35 1700mm high. Adjust the position of the limit switch on the bottom frame. (Fig.37) Raise up the platform to tough the limit switch to check it works. Note: The ceiling height shall be considered in this adjustment. Fig. 36 Height limit switch The lift is ready for working now. Fig.37 MAINTENANCE 1. Daily a. Check power supply cables, compressed air hoses, oil hoses before operation. b. Check the voltage of the power supply and the pressure of the compressed air. c. Check the parallel and leveling of the platforms. 2. Monthly 14

a. Check the leveling between the platforms. If necessary, do as following steps. First lift up the platforms to about 1400 mm high without loading.(fig. 30) Close the valve G, open the valve H. (Fig.33) Press the lift up or lower down button to make the sub platform same height as the main platform using level or water pipe level.(fig 35-36) Close the valve H, open the valve G. (Fig. 29) Now the lift is ready for working. b. Grease the necessary part of the lift such as sliding plate on the bottom frame, upper rolling dolly, shafts and the safety locking bars. c. Check all anchor bolts on the bottom frame and tighten them up in necessary. d. Chang the oil in tank after first three months or 10 hours accumulated working hours. 3. Yearly a. Clean the filter of the oil tank and change the oil totally with new one. b. Check all parts of the lift for any possible problem. 15

TROUBLE SHOOTING Fault Possible cause Solutions The motor does not start Connection of power Check and re-connect the cables. although the lifting-up has supply cables are not been pressed. correct. In lifting operation, the motor runs, but there is no lifting movement. When press Lower down button, the platform is not lowered. The lift lowers extremely slowly under normal loads. The platforms are not synchronous and not in the same height. Noisy lifting and lowering. The contactor (KM in Fig.16) in the circuit of the motor does not work. The limit switch is not work. The motor turns inverse. Lifting with light load is normal but not with heavy load. The hydraulic oil in tank is not enough. The valve G is not open.( Fig. 16) The safety locks are not released form the safety teeth. The safety locking pawl is not lifted. The solenoid air valve does not work. The lowering solenoid valve is energized but does not work. The hydraulic oil has too high viscosity or frozen, deteriorated (in Winter). The antiknock valve for preventing oil pipe burst is blocked. The air in the oil cylinder is not vent completely. Oil leakage on oil pipe or at its connections. The valve H can not be closed totally. Lubrication is not enough. The base or the lift frame is twisted. If the motor starts when forcing the contactor closed down with an isolated rod, check the control circuit. If the voltage at two ends of the contactor coil is normal, replace the contactor. Short-circuit terminal 10# and 0#, which are connected with the limit switch, and if the trouble disappears, check the limit switch, or replace it with a new one. Change the phases of the power supply cables. Or call engineer to change the connection inside the motor. The safe pressure of the over-flow valve (E in Fig 16) shall be increased by turning the knob clockwise slightly. The spool of the lowering solenoid valve (C in Fig.16) is stuck by dirt. Clean the spool. Add some hydraulic oil to the tank. Turn counter clockwise and open the valve G. First lift up the platform a little to open the safety lock then lowering it. The air pressure is not high enough to lift up the safety locking pawl. Please increase the pressure be 6-8 bar. If the solenoid air valve is energized, but does not open the air loop, check or replace the solenoid air valve. Check the plug and coil of the lowering solenoid valve. Check the tightness of its lock nut on the coil. Replace with new hydraulic oil in accordance with the instruction book. Shut off air supply and thus lock the safety pawl of the lift Remove the antiknock valve from the oil supply hole at the bottom of the cylinder, then clean the antiknock valve. Refer to STEP 7 in INSTALLATION. Tighten oil pipe connectors or replace oil seals then initialize the system and do leveling again. Replace valve H, and then level the platforms. Lubricate all hinges and motion parts (including piston rod) with oil or grease. Again level the platforms and make the bottom frames stable. 16

APPENDIX 1. PARTS DRAWING 17