Atomizer 36-DC User Guide

Similar documents
Parts Catalog TECHNICAL DOCUMENTS TABLE OF CONTENTS. Electric. Other. Non-electric

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

I Button Chemical Dispenser. Overview. Installation Instructions

Residential R.O. components

WATER TREATMENT COMPONENTS. Residential R.O. components

2016 PRODUCT CATALOG. Fogco Systems, Inc Fogco.com FOGCO

QUALITY MISTING PUMPS

AD-830. Parts Manual thru 1997

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

MASTER. Water Conditioning Corp. Installation and Operation Manual. MCA Combination Series Residential Units

QUALITY MISTING PUMPS

Nessie Water Mist Nozzles

PRICE LIST

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

665 Series Dispenser. Metering tip kit

Reverse Osmosis System

WATER SOFTENER SERIES DAY TIMER INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

Material required for drilled well application (indoor use only)

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Troubleshooting WARNING

AQT-275 SERIES SERVICE MANUAL CONTROL VALVES

HSE M11 (AFTER SERIAL # )

Users Manual Certified Series Direct Drive Pump 1-7 LPM

Rev: Flow Max 115V AC Fluid Pump

INSTALLATION AND USER MANUAL

Installation Instructions

WATER SOFTENER SEMI AUTOMATIC INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

LAWN SPRINKLER, IRRIGATION PUMP

*Please Note* All Instructions, Manuals, Extra Orifices, Adjustment Tools, Setting Charts, Etc. MUST BE GIVEN TO END USER!

Iron Gate Air Pump System Manual

MAC FAUCETS FA400 WALL MOUNT FAUCETS

TROUBLESHOOTING. 1. What is the model and serial number? If you don t know, how old is it? Give description.

23200 Navigator Dilution Control System 4 Button Model (NAV 4)

INSTALLATION INSTRUCTIONS

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

& Tower for PWM Control. Maximum Application Rates with Two 5.3 GPM Electric Pumps

GE Infrastructure Water and Process Technologies. Merlin Point of Use Drinking Water System. Installation and Maintenance Manual

65 Series. Valve Operation Manual

Mizer Single Pump and Starter Box

Installation & Operation

AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES

201 East Street South, PO Box 278, Vernon Center, MN U.S.A PRICE LIST

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

PBF OWNER S MANUAL PBF-510 PINSPOTTER MACHINERY DIVISION

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

MICROPROCESSOR CONTROL WATER SUPPLY SYSTEM (MPR-01AW)

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC

K5 Drinking Water Station Installation Instructions

SERIES-1 SERIES-1.5 SERIES-2 AEC GROUP 3600 WEST CARRIAGE DRIVE SANTA ANA CA

SHURFLO AQUA KING II STANDARD 3.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

Installation / Operation Manual

This catalog contains the following geothermal accessory products and specification guides:

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

Reverse Osmosis Systems Section 11 Reverse Osmosis Systems

INSTALLATION INSTRUCTIONS

Part# JL AIR IT UP 4 Tire On Board Air Delivery System. (Requires External Air Source)

MF-12A MF-12A OWNER S MANUAL MF-12A PINSPOTTER MACHINERY DIVISION

TotalPac 3 Deluge system Pneumatic release

Fog Misting System. Misting systems have been used in outdoor cooling applications for decades. These systems can provide outdoor cooling

36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

8650 Enterprise Drive, Peosta IA / Fax

SHALLOW WELL JET PUMP

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

Compressor Installation Guide

Certo Chemical Dilution System

CATALOG OF REPLACEMENT PARTS

STAR STOP SHALLOW WELL JET PUMP

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

Designed to quickly and safely test fire hose lines!!

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

348002K/348012K Manifold Block Style Service Manual 12/2000

USER MANUAL MODEL NUMBER: FST FSTK FSTV. Flooded Suction Tank. English

MC2500. Installation and Operation Manual

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

ILLUSTRATED PARTS LIST

Field-IQ & PumpRight for PWM Control. Pump Models & Flow Capability. Max Flow GPM

SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

2) Mark wall at 5 10 for center line of bottom bolt-hole in wall brackets on transition box side of floor.

or OWNER S MANUAL MODEL R

INSTALLATION INSTRUCTIONS

Drip-n-Gro Dual Top Feed Drip System Instruction Manual

MODEL H INSTALLATION INSTRUCTIONS

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

MODEL SS INSTALLATION INSTRUCTIONS

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Iron Gate Feed Pump Manual

Compact LTC Oil Filtration System Manual

Chemical Free Iron Sulphur Filtration System Owner's Operation and Maintenance Manual

PowerAir Compressor Installation

Installation Manual. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL

1600 PSI ELECTRIC PRESSURE WASHER

350 S. St. Charles St. Jasper, In Ph Fax

ClassicSeries Compressor Installation

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines

Heavy Duty Sprayer Owners Manual Model MS-O

UltraDose From Lyn Distributing

Transcription:

TECHNICAL INSTRUCTIONS Atomizer 36-DC User Guide SERVICE CASE HUMIDIFICATION Specification Sheet... 2 Installation Guide... 3 Layout Diagram... 4 Maintenance Guide... 5 Wiring Diagram... 6 Pull Sheet... 8 SEP 23, 2015 Specification Sheet 2 SEP 23, 2015

Specification Sheet Mist bar with clips and welter wings Features Automated dampening system Nozzle free micro mist bar Reverse osmosis water filtration removes dissolved minerals Safe 24 V power supply Factory assembled for easy mounting and installation Color coded plumbing Integrated timing modules Powder coated cabinet Low energy consumption Can fit any type of case Maximum performance Scheduled maintenance includes system check and easy annual filter change Model ATOMIZER 36-DC Maximum length for moist on 36 feet (10 m) Nozzles supported N/A Location Requirements Electrical Source Water Supply Inlet Pressure Drain Maintenance Prefilter (#11009) Membrane (#11076) Specifications Size: Height Width Depth Weight Water Pressure Gauges Operating Voltage Unit Power Consumption Pressure Tank Pump Solenoid Valve: Mist Purge Air Compressor Droplet size Tubing Materials Heat Resistant Tube Mist Bar Materials Dimensions 100/115/230 V AC, 50-60 Hz 1/2" FPT Adapter with Shutoff Valve 30 psi (2 bar) minimum Floor Drain or 1/2" Drain Pipe Change every year Change every year 18.5 inches (47 cm) 14 inches (36 cm) 4.25 inches (11 cm) 36 lb (16.3 kg) Product, Inlet 24 V DC 120 V, 1 A / 240 W 230 V, 2 A / 230 W 24 oz / 125 psi Diaphragm Plastic 1/4" FPT Plastic 1/4" FPT N/A Over 30 microns Color coded Polyethylene High pressure rated N/A PVC UV Stabilized 0.5 H x 1.25 W (inches) Bar Flow Orifice Approx. 5/32" Mist Tips Materials: Tip Polyacetal Plastic Check Valve Rubber Spring Stainless Steel Valve Seat Nylon Plastic O-Rings Rubber 2 MIATECH TECHNICAL INSTRUCTIONS Atomizer 36-DC User Guide Specification Sheet SEP 23, 2015

Installation Guide WATER SUPPLY Connect the green 1/4" tubing to your water supply and insert the green tubing into the green port marked inlet. Important: When cutting tubing, make sure the cut is straight to insure a proper seal. A tube cutter tool is recommended (part #27002). DRAIN/BRINE Run the red and yellow 1/4" tubing from your drain supply to the AT 36-DC and insert the red tubing into the red port marked drain and the yellow tubing into the yellow port marked brine. If draining into a floor sink drain, a 5" inch air gap is required. Note: The air gap is required for sanitation reasons when draining into a floor sink drain. MIST BAR FEED LINE Install mist bar into display case using mounting clips. Run the 3/8" mist tube from the system to the far end of the mist bar run (see layout diagram). Starting from the far end, using the 1/4" tubing and 3/8" x 1/4" reducer (#17052) connect mist line to the mist bar elbow. Cut the 3/8" mist tubing in places next to each feed port on a bar. Then using the 3/8" x 1/4" x 3/8" tee (#17104) and 1/4" tubing, attach to every feed port on a mist bar run. Check for kinks in the line. Secure feed lines to the case using cable ties provided (#24078) and self-drilling #8 screws (#24001). Additional insulation might be needed if tubing is located inside the refrigerated case to avoid any freezing. TEST SYSTEM Turn on water supply. Turn on power switch. Turn the OFF time adjustment knob dial all the way up (see picture 2). Once the pump stops, the OFF dial can be turned down if product requires more moisture. The pump will turn OFF once the product pressure reaches about 125 psi and will turn back ON when the product pressure Picture 2 drops below 95 psi. Set the ON time dial pot, which is located on the Timer Module (#23181), to approximately 1/2 second. Watch the mist pulsate out of bar over the product displayed. Keep in mind this setting should be short bursts of highpressure atomized mist to avoid saturating the product with moisture. The OFF time duration should be set for a minimum 15-25 minutes (3-5 o clock position) depending on product and case environment. POWER SUPPLY Connect the low voltage power supply adapter from transformer in the female connector. Check the transformer input voltage tag located on the top of the transformer to make sure the appropriate step-down transformer matches the proper voltage supplied. Next, plug the transformer power cord into the power supply receptacle (100 V, 120 V or 230 V 50/60 Hz) (see picture 1). Picture 1 Warning: AT 36-DC unit is operating under 24 Volt DC, therefore only Miatech DC transformer should be used. 3 MIATECH TECHNICAL INSTRUCTIONS Atomizer 36-DC User Guide Installation Guide SEP 23, 2015

Layout Diagram 4 MIATECH TECHNICAL INSTRUCTIONS Atomizer 36-DC User Guide Layout Diagram SEP 23, 2015

Maintenance Guide Maintenance Requirements 1. Prefilter and membrane should be replaced at the same time once a year. 2. Nozzles should be wiped down when case is cleaned. 3. Gauges should be checked for adequate inlet and product pressure. 4. Unit should be inspected for leaks. 5. TDS reading should be taken to ensure it does not exceed 50 % of the inlet water reading. 6. If more or less moisture is desired, remember that only small changes make a big impact and may take a day before fully realized. Typically settings are on for about 5 seconds for about every 20 minutes of OFF time. 1 Troubleshooting Problem Some tips are dripping after mist. Most of the tips are dripping after mist. Solenoid Valve is buzzing or skipping mist cycles. Timing for mist times is inconsistent. Solution Replace tips with new ones. Bad ball checks. This suggests purge valve is not opening or a line restriction exist. Verify that no tubing is kinked between the system and bar, along with no kinks in the red tubing. Check red Drain/Purge line to verify water is dumping to release pressure in the mist bar after each mist cycle. Adjust the Purge Valve ON time to at least 2 seconds to see if the issue is resolved. Check to see if valve is getting an electric pulse after mist cycle. If not check wiring connections or replace timing module. If a 24 V pulse exists then purge valve will need to be replaced. If water is exiting the red line after each mist then a line restriction must exist. This will sometimes cause a slow ON for mist as well. This could be caused by feed ports on mist bar being over tightened, potentially cutting off the water supply to the bar. In this case the solenoid valve may need to be replaced. First check to see if the valve is receiving approximately 24 V signal from the timer during the mist cycle, if not the timer should be replaced. Replace timing module. In rare cases it may require the replacement of the dial pot for OFF time. 2 3 4 5 6 Pump never turns off. (Providing it has inlet pressure and the filters/ membranes are not clogged). If product pressure rises substantially above 145 psi, replace high pressure switch. If pump never reaches 125 psi product and inlet water exists then replace pump. 7 14 12 13 15 11 8 16 9 17 10 18 14 19 Pump never turns on. Mists for split second and begins dripping or only drips. 1. 24 V DC Transformer 115 V (#23211), 230 V (#23212) 2. Power switch (#23132) 3. 5 amp reset breaker (#23247) 4. Green LED panel mount (#23140) 5. Inlet gauge (#15005) 6. Product gauge (#15005) 7. Dial pot 20 K (#23246) 8. Mist valve (under the metal plate) (#12048) 9. Timer module (#23181) 10. 24 oz Accumulator black tank (#21003) Check the breaker, high pressure switch, transformer or pump needs replaced. Watch Product gauge during a mist cycle. If it drops near 0 psi, then pressure tank has lost air pressure. All water will need to be drained from the tank and refilled with air to 65 psi. If the air pressure is not holding, replace the tank. If water comes out of the Schrader valve, the tank needs to be replaced. 11. Carbon filter (#11009) 12. Low energy 75 gpm membrane inside (#11076) 13. Housing membrane (#11074) 14. Flow restrictor (#11012) 15. Brine valve (#12050) 16. Purge valve (#12048) 17. Pressure switch (#14001) 18. Low flow pump (#10025) 19. 1 way check valve (#17149) 5 MIATECH TECHNICAL INSTRUCTIONS Atomizer 36-DC User Guide Maintenance Guide SEP 23, 2015

Wiring Diagram 6 MIATECH TECHNICAL INSTRUCTIONS Atomizer 36-DC User Guide Wiring Diagram SEP 23, 2015

Notes

Pull Sheet Pack PART NO. PART NAME AMOUNT Insp. 17131 88 MPT x 44T Male Connector - QC 1 18004 66 Black Tube (to mist bar) 30' 18023 44 Red Tube (purge/drain) 30' 18024 44 Green Tube (inlet) 30' 18025 44 Yellow Tube (brine) 30' 24001 #8 x 3/4" Self-tapping Screw (Phillips) 30 24003 12" Nylon Tie 6 24078 Cable Tie 6" Black 30 24034 #14 x 2 1/2 Flat Sheet Metal Screw (Phillips) 4 24035 #14 Plastic Anchor 4 23211 115 / 24 Volt DC Transformer See Mist Bar 23212 230 / 24 Volt DC Transformer Pull Sheet DATE PULLER CHECKER Miatech Inc. 9480 SE Lawnfield Road Clackamas, OR 97015 www.miatech.org For further technical support in North America call 1-800-933-6478 If outside North America call to the USA at 1-503-659-5680