SPH-400 i Series General Manual

Similar documents
SPH General Manual 400 Series

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

ZENOTEC Air + Instructions for Use. ivt (120 volt) & ivt25-912(230 volt)

ivac TWIN Premium Turbine Dust Collectors

Premium Turbine Dust Collectors

I-6500 Series. Industrial Applications. Operations & Maintenance Manual. Air Purifiers for. Manufactured. Serial number.

Source Capture Air Purification System

quatroair.com AIR TECHNOLOGIES INC.

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Installer s Manual. PCO/UV N-Duct Model

EXT DUCTLESS FUME HOOD

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

CA 5054 Owner s Guide

Owner s Guide. ca6154

Owner s Guide CA 5055

Owner s Guide. ca5354

Owner s Guide CA 4555

Owner s Guide ca4054 ca4554

VTC610 Series Voltage Converter. Installation & Operation Manual

EXT HEPA/CARBON FUME HOOD

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

RK Standby Battery Operator s Manual

Owner s Guide. ca5154

For ELECTRONIC INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS TO BE USED IN CONJUNCTION WITH: SERVICE GUIDE for Gage Unit

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

Owner s Guide CARS & CA4B5

Installation & Operation Manual Chef Base

Installation & Service Manual for Portable Fume Collector. Model PFC-800

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

O W N E R ' S M A N U A L

Premium Pond Pump 330 Gallons Per Hour

8-Bay Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual. Please read before using this equipment.

MODEL MC1500 Installation and Operation Manual Important:

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

AeraMax Pro AM IV. Please read these instructions before use. Do not discard: keep for future reference.

Owner s Guide PR1BZ PR1BZLR

OMEGA CORDLESS SERIES VACUUM INSTRUCTION MANUAL

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

High Capacity Battery Charger

RK Standby Battery Operator s Manual

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

Quest H5. Quest Dry. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest H5:

Operating Manual PFB-2500

ES25 Battery-powered ACSR Cutter with 120 V Charger with 220 V Charger

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

PATRIOT INSTRUCTION MANUAL FMGRID-16, FMGRID-24, FMGRID-30 ELECTRIC GRIDDLES

Premium Waterfall Pump 1200 Gallons Per Hour

Read this entire manual before operation begins.

Heated Bakery Merchandiser Series. Series: WBC Operation Manual

Table of Contents. Safety Information Main Functions Set-Up Operation Maintenance Troubleshooting Specifications Customer Support Warranty Information

VTC1000 Series Voltage Converter. Installation & Operation Manual

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

ca1153 Owner s Guide

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

Countertop B.I.B. Butter Dispenser Instruction Manual Model #2496

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AA-98 AirPac II Compressor 110V

n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

Quick Start Guide Expansion Battery Pack UPS-OLEBPR-1 UPS-OLEBPR-2

Further information: Berriman Associates Model 850P.2 Owners Manual

REMOVAL OF FACTORY GAUGE ULTRA FLHT & FLHX (STREET GLIDE

Owner s Manual GLASSLINED PUMP TANK

Natural Fiber Planter Fountain

GA-160 Gas Amplifier

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

600 Amp Battery Jumper with Air Compressor

2SHE Series Direct-Drive Shutter Fans

For BLOWER INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

GW-120 Bar Glass Washer

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE

MODEL 585 BATTERY BACKUP PEDESTAL SUMP PUMP PREINSTALLATION CHECKLIST SEE BELOW FOR LIST OF WARNINGS CAUTION SEE BELOW FOR LIST OF CAUTIONS

Owner s Guide APS596Z

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BTX-208. Fume Extraction System _B

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

Owner s Guide CA 1055

Document No D1 Revised December Atlantic Ultraviolet Corporation

Duo Charger. for Digital Camera and Camcorder Batteries. Owner's Manual. Please read before using this equipment.

Owner s Guide CARS & CA2LCD5

FA1 Series Air Filtration System. Operations Manual

Illumifalls Patio Pond

COLT CELL BATTERY CHARGER Installation and Operating Instructions

HYDRAULIC LEVELING SYSTEMS OPERATIONS MANUAL (For systems with touch pad part number , , , , or no number at all)

ARM-EVAC 50. Benchtop Plenum/Arm Extractor MANUAL NO REV. B

Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC

SUNC3000 / Item #40885

Portable Electric/Gas Compressor Operating Instructions

MODEL H INSTALLATION INSTRUCTIONS

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Export Bucket Pump Instruction Manual Models: 2114XE & 2114XD

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Series 2100 Operating Instructions

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

INDOOR LED BAR DIGIT HOCKEY SCOREBOARD INSTRUCTION MANUAL REVISION DATE: PART#:

Transcription:

Operations & Maintenance Manual SPH-400 i Series General Manual Models: SPH-425, SPH-426, SPH-4B5, SPH-4BU5, SPH-4B6 with i Series contols. ------------------------------------------------------------------------Engineering Clean Air------------------------------------------------------------------------ 30 Hymus Blvd., Montreal, Quebec, Canada H9R 1C9 Tel.: (514) 630-4444 Fax: (514) 630-4454

QUATRO 1- INTRODUCTION You are now the owner of a Quatro SPH System, an advanced effective indoor air purification system designed specifically to remove particulate matter and/or gas phase contaminants. You can expect a noticeable improvement in air quality as the SPH begins the process of reducing microscopic airborne particulate as well as harmful and odorous gases. 2- IMPORTANT SAFETY PRECAUTIONS WARNING- To reduce the risk of severe injury read and follow all instructions -To reduce the risk of electric shock, do not expose to water or rain. Do not operate the system in areas with excessive moisture. -Ensure to use proper voltage as noted on the serial # sticker -All filters must be in place whenever this machine is in operation. -Use only on a grounded electrical circuit; do not use any two-wire electrical prong adapters to defeat the three-pronged plug on the end of the cord. -Disconnect power prior to accessing unit, when checking or replacing filters, or servicing motor (blower). -When servicing the motors be careful when touching the exterior of the motor as soon as it has been turned off; it may be hot enough to be painful or cause injury. With modern motors, this condition is normal when operated at rated load and voltage, as they are built to operate at higher temperatures. SAVE THE INSTRUCTION FOR FUTURE REFERENCE 3- IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk of fire or injury read and follow all instructions. -Do not install or operate the system in an enclosed space. Do not block discharge grill. Keep all objects at least 6 away from the casing. NEVER place the system up against a wall. -Do not kink hose or restrict airflow in any way. SAVE THE INSTRUCTION FOR FUTURE REFERENCE 4- IMPORTANT OPERATIONS INSTRUCTIONS WARNING To reduce the risk of damage to your system read and follow all instructions. Failure to follow these guidelines may result in undesired operation or damage that will not be covered under warranty. -THE SYSTEM IS DESIGNED TO BE CONSTANTLY POWERED (PLUGGED IN). USE THE ON/OFF ONLY SWITCH TO TURN THE SYSTEM ON & OFF -ALWAYS SWITCH THE POWER OFF BEOFRE UNPLUGGING THE SYSTEM FROM THE MAIN POWER SOURCE OR BEFORE CUTTING POWER TO THE RECEPTACLE. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE SYSTEM THAT IS NOT COVERED UNDER WARRANTY. -QUATRO IS NOT LIABLE FOR MISAPPLIED EQUIPMENT. ALWAYS CHECK SYSTEM VOLTAGE BEFORE PLUGGING INTO POWER SOURCE Warning: This is a class A product. In domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. Page 2

QUATRO 5- PRE START-UP CHECKLIST a) Place the SPH System in the desired area for use. b) Install filters in sequence depending on the application. For Dust/Odor Applications (2 Filters) 1 st filter to be lowered into place is Part # : AG097 2 nd filter to be lowered into place is Part #: F074 3 rd filter to be lowered into place is Part # : F071 With The Metal Support Frame 4 th (Optional) filter to be lowered into place is Part #: F069-71 Note: This filter is not used when the optional Knock Out Pad (F166-125)is used on the inlet c) Close lid and adjust latches for a snug fit d) Connect the supplied hose to your equipment 6- START-UP a) Insert male end of power cord into grounded circuit of the proper voltage and that can handle the system amperage. b) Turn the SPH System On. The system does not need to be on all the time nor does it need a warm up period. It can be turned on and off as needed. c) Air purifier should now be functioning and operational; d) Adjust controls to desired airflow. If noise and suction are acceptable operate at max speed for max removal. WARNING: DO NOT OPERATE UNIT UNLESS ALL FILTERS ARE IN PLACE. Note: The filters in this system are not cleanable. They need to be removed and disposed of periodically. See Sections 8 & 9. 7- i Series Controls i Series Controls Our i Series Controls feature soft touch On/Off, Speed Up & Speed Down Buttons and a remote operation interface that can accommodate any of the Quatro hand or foot remotes as well as be adapted to power switching remote control power plug (Contact Quatro For More Info). It also features a visual and audible Replacement Indication System for the filters and the motor brushes & and automatic system pressure compensation system called Autoflow. After setting the minimum speed required to properly evacuate your equipment the controls will automatically increase the motor speed to compensate for the increased pressure of dirtying filters until maximum speed is reached and after a filter change will automatically decrease the speed to the original set point. Remote Operation To enable the remote system startup simply put the unit on with the power button on the control panel AND THEN activate the remote switch. L5 on the SPH System will go on indicating that the remote signal had been accepted. Whenever the remote signal is supplied the unit will instantly start and when the remote signal is stopped the unit will stop after a 30 second delay. The Fifth LED ON indicated the unit is receiving a remote signal to operate. The first LED flashing slowly indicate the unit is in standby an is waiting for a remote signal to operate. At this point the On/Off switch will only serve to switch between Standby and Off. If you wish to return the unit to regular On/Off operation (with the panel mounted switch) AFTER REMOTELY TRUNIGN THE UNIT OFF just unplug the power and plug it back in FROM THE WALL PLUG. After the unit is plugged back in, regular function of the On/Off switch is restored. Page 3

Light Diagnostics Table (Rev C10-4 & D10-4) Light Led 1 Led 2 Led 3 Led 5 Audible Alert System Operation Low System Pressure Service Motors Service Filters Slowly Slowly Slowly Second 4 Hours 15 Mins 5 Mins Second Condition Unit in operation Unit is operating using POWER button on panel, no remote signal Unit in operation Unit is operating using remote signal (or mc2 signal if provided) Shutdown delay (Remote /mc2 signal has been removed) Unit is in Standby mode, waiting for remote signal (or mc2 signal if provided) to start unit Abnormally Low Pressure, Unit has or Will Shut Down If Not Corrected Action Check Motor(s), Check Motor Brushes, Verify If Filters Are Installed, Close All Filter Access Points 50 hrs of life left in brushes Order brushes if not already on hand. If Brushed on hand change now and reset alert. 30 hrs of life left in brushes Unit Will SHUT DOWN In 30 Hours to prevent motor damage 10 hrs of life left in brushes Unit Will SHUT DOWN In 10 Hours to Motor Brush Life Expired Unit Shut Down prevent motor damage Replace ALL motor brushes. (iv-111: #AB112, ivt-121: #AB114) Reset Brush Life Alert Filter Pressure High Prepare To Replace/Service Filters Hour Second Hour Filter Pressure Close To Critical Replace/Service Filters Now. Continued Operation Will Result In Unit Shutdown Critical Pressure, Unit Shut Down Verify Blockage, Verify All Filters Replace Filter (s) ASAP Replace Filter (s) ASAP HEPA Filter: AG183 Cartridge Filters: iv-111: AG181, : ivt-121: AG182 ------------------------------------------------------------------------Engineering Clean Air------------------------------------------------------------------------ 30 Hymus Blvd., Montreal, Quebec, Canada H9R 1C9 Tel.: (514) 630-4444 Fax: (514) 630-4454

8- SPH-400 Series Specifications Dimensions, Height: 28.5 (724mm) + arm Voltage / Current Dimensions, Width: 12.75 (324mm) Max. Power Consumption: Dimensions Length: 15.75 (400mm) Approx. Weight: 115/1/60: 12.9 amps 230/1/50: 6.5 amps (60Hz) 115V: 1650 watts 230V: 1500 watts (60Hz) 70lbs (27gs) Without Filters 9- FILTER REPLACEMENT GUIDE SPH-400 Proper maintenance is critical to extend the life of the filtration system. The information presented below outlines basic maintenance procedures ensuring the unit will provide trouble-free operation for years to come. The purifier is designed to allow quick access to the filters. The Replacement Indication System monitors system pressure and tells you when the particulate filters need servicing. It is good practice to replace the Pre Filter (F071) & Optional Dust Pads (F166-125) every 1-3 months and to rely on the Replacement Indication System to change the Hepa (F074). The Chemical Filter (AG097) should be replaced once a year or when odor is detected breaking through the system. Every time the Chemical Filter (AG097) is changed the Gel Seal should be inspected. If damaged, repair with Part Number AR020 for proper operation If a critical pressure is reached the unit will shut down to prevent damage. This will occur even if your equipment is in mid process. It is advised to change the filter when prompted or ASAP to avoid a shutdown. See Section 8 for more details. 10- FILTER REPLACEMENT INSTRUCTIONS Access to all filters are through the top cover for the SPH System. Part Numbers F071, F074 & AG097 are a simple drop in affair. Part number F166-125 is stuck on the inlet deflection plate of the cover and is replaced by peeling away and replacing with another. Filters in order from top to bottom Pre-Filter Pad Installed Bottom View Pre-Filter Pad Installed Top View F071 2 Dust Filter AS052 Dust Filter Frame F074 2 HEPA Filter AG097 8 Chemical Filter Odor Filter Refilling - Ensure that the unit is unplugged, unlatch top section and remove. - Pull out AG097 and discard any remaining odor granules, refill with new odor granules. - Inspect Gel Seal. If damaged, repair with Part Number AR020 before putting the system back into operation - Put filter tray back into position (Stage IV/ bottom). Secure top back into position and both latches. The airtight seal should be maintained. If you do not wish to replace the chemical the entire module can be purchased. The part number is AG097 Consult local authorities for proper filter disposal procedures. ------------------------------------------------------------------------Engineering 30 Hymus Blvd., Montreal, Quebec, Canada H9R 1C9 Clean Air-----------------------------------------------------------------------Tel.: (514) 630-4444 Fax: (514) 630-4454

QUATRO 11- MOTOR SERVICE The Replacement Indication System will prompt you when it is time to change the motor brushes. If the warning is ignored the unit eventually will shut down to prevent damage. This will occur even if your Rayjet is in mid process. It is advised to change the brushes when prompted or ASAP to avoid a shutdown. See Brush Replacement Instruction Below. Brush Replacement Instructions You do not have to remove turbine from unit to change brushes! To access motor, turn system upside down and remove the bottom caster plate. Once removed the motors and brushes will be accessible. 1) Ensure that the system is unplugged from power before servicing the blower; 2) Unlatch and remove top cover, and remove all filters 3) Turn unit upside down 4) With a Phillips screwdriver, remove (8) screws along the perimeter of the unit, lift off base You should now see the 2 motors Blower access caster plate View of blowers once caster plate is removed 6) Using a phillips screwdriver, unscrew the 2 screws holding down each of 2 gold colored brush casings (see Figure 1) 7) Lift gold colored tab and lift/pull out each brush (Figure 2 shows right brush removed) 8) Replace each brush onto turbine motor, screwing down the phillips screws over tab. Screws Figure 1 Figure 2 Figure 3 9)Assembly is the reverse of steps 1-8. RESET BRUSH ALARM If Motor Brushes are replaced WHILE BRUSH REPLACEMENT LIGHT was FLASHING Unplug POWER to unit Replace Motor Brushes Close motor access door Plug power back to the unit When you Press POWER ON, Motor will START BUT Brush Replacement Light will continue flashing HOLD UP & DOWN ARROWS (at the same time) until unit BEEPS (5 seconds) at this point Brush Light will Dim (other lights may be dimming or ON) using UP/DN arrows, Press UP until Service Motor(s) light is FLASHING press POWER button, Service Motor light will go OFF, speed will default to LOW SPEED to break new brushes in (to prolong brush life) do not press anything for 20 seconds IT IS ADVISED TO LET MOTOR OPERATE AT LOW SPEED FOR 15 MINUTES If Motor Brushes are replaced AFTER MICROPROCESSOR HAS SHUT UNIT DOWN (Brush Replacement Light is FULL ON, not flashing) Unplug POWER to unit Replace Motor Brushes Close motor access door Plug power back to the unit When you Press POWER ON, Motor WILL NOT START but Brush Replacement Light will BE ON HOLD UP & DOWN ARROWS (at the same time) until unit BEEPS (5 seconds) at this point Brush Light will be ON (others may be lit or dimming using UP/DN arrows, Press UP until Service Motor(s) light is FLASHING press POWER button, Service Motor light will go OFF, speed will default to LOW SPEED to break new brushes in (to prolong brush life) do not press anything for 20 seconds IT IS ADVISED TO LET MOTOR OPERATE AT LOW SPEED FOR 15 MINUTES Page 2

12- TROUBLESHOOTING GUIDE Symptoms Possible Cause Suggested Solution QUATRO Unit Will Not Start Unit Starts, Then Stops Excessive noise Faulty Power Supply Control Panel Circuit Breaker Tripped Unit Not Plugged Into Receptacle Excessive Pressure Hose Blocked Particulate Filter Blocked Filter Not Installed Motor Bearing Failure Rubber Motor Isolators Broken Check Breaker Box Reset Circuit Breaker Plug Unit In Change filters, look for system blockage Remove Obstruction Replace F071 / F074 Install Filters Replace Motor Replace Isolator 13- WARRANTY QUATRO Air Technologies warrants its equipment to be free from defect in material and workmanship under normal use and service for a period of one year from date of shipment. QUATRO's obligation under this warranty shall be limited to replacing any parts, thereof, which shall be demonstrated to have been defective. This is expressly in lieu of all other warranties, express or implied, including the warranties of merchantability and fitness. QUATRO claims no warranty as to merchantability or as to the fitness of the merchandise for any particular use and shall not be liable for any loss or damage. No person, firm or corporation is authorised to assume for QUATRO any other liability in connection with the sale of these goods. Equipment, parts and material manufactured by others and incorporated in QUATRO's equipment are warranted by QUATRO only to the extent of the original manufacturer's liability to QUATRO Conditions and Limitations: This warranty does not cover abuse, misuse, maintenance negligence, improper assembly, acts of vandalism, acts of God, fear wear, modifications of the equipment or installation of a part not recommended by QUATRO Air Technologies, as well as operation of the equipment at voltages other than those specified by QUATRO Air Technologies Inc. 14- SPH-400 i Series REPLACMENT FILTER & PARTS Qty Description Part 1 Control Panel 120V AE085-16 1 Control Panel 230V AE085-26 4 Caster (Single) H042 1 Cover Gasket Roll (40') H006 1 Gel Repair Kit AR020 1 Blower Motor Assy 120v AB001 1 Blower Motor Assy 230v AB002 1 Power Cord 120v E220 1 Power Cord (Euro 230V) E130 1 Pre-Filter Pad (12 Pack) AG168 1 Pre-Filter Pad (25 Pack) AG169 1 2 Dust Filter F071 1 2 Hepa Filter F074 1 8 Chemical Filter (General Purpose) AG097* * Chemical Filter Refill Kit Is Available Part Number NC-GPC Page 3