Process Protection Motion sensors

Similar documents
Process Protection Motion sensors

Process Protection Motion sensors

Motion sensors. Milltronics MFA 4p 6/17. Overview

Process Protection. 7/2 Product overview. 7/3 Acoustic and motion sensing. Acoustic sensor for pump monitoring 7/5 SITRANS DA400

Belt Scales Speed sensors

Level Measurement Point level measurement - RF Capacitance switches

Belt Scales Speed sensors

Belt Scales Belt scales accessories

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Belt Scales Milltronics belt scales

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement Continuous level measurement Ultrasonic transmitters

Point level measurement Capacitance switches

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Continuous level measurement - Radar transmitters

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Belt Scales Milltronics belt scales

Level Measurement Continuous level measurement - Capacitance transmitters

Weighfeeders SITRANS WW200

Belt Scales Milltronics Belt Scales

Belt Scales Milltronics belt scales

Level Measurement Point level measurement - Vibrating switches

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview.

Belt Scales Milltronics belt scales

Flow Measurement SITRANS F M

Continuous level measurement Capacitance transmitters

Flow Measurement SITRANS F M

Belt Scales. Speed Sensors. Milltronics Bend Pulleys. 4/48 Siemens WT Technical specifications. Overview

Level Measurement Point level measurement - Vibrating switches

Ultrasonic Non Contact Sensors

Flow Measurement SITRANS F C

Shaft Speed Switches. SCP Series Speed Switch. M Series Speed Switch M100T/M5000T. Our Most Popular Speed Switch!

Level Measurement Point level measurement - Rotation paddle switches

PRODUCT INFORMATION BULLETIN

Armstrong In-Line and Insertion Vortex Flow Meters

MODEL CMS INSTALLATION INSTRUCTIONS A. INTRODUCTION 1. USAGE 2 2. HOW IT OPERATES 2 B. SPECIFICATIONS 1. ELECTRICAL 3 2.

STOCKTROL-H VIBRATING LEVEL SWITCH. Instruction Manual June 2002

Flow Measurement SITRANS F C

ROTARY Point Level Measurement for Inventory Control

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

GTV Series High Pressure Control Valves

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Shock/Vibration Control Switches

Solids Flowmeters LVDT flowmeters

RS85 Vibrating fork level switch

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

RP-4000 Reserve Power Control

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

SITRANS F M. Flow sensor MAG 1100 F 3/59

V200 Series Positioners

MAXIGARD A2000 SPEED SWITCH. Introduction

ELECTRICAL INSTALLATION

Seismic Sensor Accessories SA, SV & ST 6000 Series

2-Way/2 Position Valves

PROCAP Capacitance Level Sensors

Models UP1/2/3/4/5/6/7 Universal pneumatic rotary actuators. Measurement made easy. High performance actuators for precision damper control

Model 550 Series Vibration Switches

Belt Scales. 4/35 Speed sensors 4/35 Milltronics TASS 4/37 Milltronics RBSS 4/40 SITRANS WS100 4/45 SITRANS WS300 4/50 Milltronics bend pulleys

PROCAP Capacitance Level Sensors

RPPN3 - RPPN7 Industrial pressure switch

Rotary Paddle Bin Monitor MODEL KA & KAX

PCVS Series Control Valve Supervisory Switch

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Belt Weighing. Milltronics Belt Scales. Introduction. 4/2 Siemens WT

Super-Safe-Plus Roto-Bin-Dicator

Appendix. Clearance. Skewed profiles. Application Schematics

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT.

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

R F C a p a c i t a n c e TrueCap

Solids Flowmeters. 6/2 Introduction. 6/6 LVDT flowmeters 6/6 SITRANS WF100 6/11 SITRANS WF200 series 6/16 SITRANS WF300 series

RDN4 - RDN8 Differential pressure switch

ILE - 61 SENSING HEAD

Electromagnetic Flow Monitor magphant

Linear Valve Electric Actuator

Model Q45H/ Residual Chlorine Monitor...

Level instruments. Point level measurement - Vibrating switches SITRANS LVL100. 5/78 Siemens FI Horizontal mounting.

Pratley Ezee-Fit Box Replacement Gaskets Replacement Gasket for the Pratley Ezee-Fit Box

RPPN6 - RPPN8 Industrial pressure switch with high overpressure resistance

Instruction Manual October milltronics MD-36 SPEED SENSOR

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

DPT TARGET TYPE FLOWMETERS

Shock/Vibration Control Switches Installation Instructions Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94 GENERAL INFORMATION LISTED*

BinMaster Price Book

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

Cable (Rope) Pull Switches Lifeline 4

Data Sheet. A-Series Miniature Watertight Pressure Switches

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Model DFX Doppler ultrasonic flow meter

Temperature Measurement Resistance thermometers

PRO REMOTE Series CAPACITANCE PROBE

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

KEL DIFFERENTIAL PRESSURE FLOWMETERS

DIESEL Engine Fire Pump Controllers Features

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Transcription:

Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Design Benefits Up to 100 mm (4 inch) gap between target and probe Switch selectable overspeed or underspeed detection Setpoint adjustment 0.15 to 3 000 PPM (pulses/minute) Adjustable start-up time delay Visual indication of probe operation and relay status General purpose, suitable for majority of industrial applications; rugged probe designs provide unmatched reliability Application The MFA 4p detects changes in the motion and speed of rotating, reciprocating or conveying equipment. It warns of equipment malfunction and signals through contacts to shut down machinery in case of a slowdown or failure. Its reliability makes it a cost-effective way to protect valuable process equipment. The single setpoint system suits most industrial applications. This versatile unit can be used on tail pulley shafts, driven pulleys, motor shaft sensing, belt or drag conveyors, screw conveyor flights, bucket elevators, fans and pumps. A special feature is the adjustable 0 to 0 second time delay, allowing the monitored device to accelerate to normal running speed before monitoring begins. A wide range of probes are available to suit specific needs, including high temperatures and corrosive installations. The CE approval allows the MFA 4p to consistently meet the needs of the mining aggregate, cement and other primary and secondary industries. Key Applications: tail pulleys, motor shaft sensing, screw conveyor flights, bucket elevators Mounting for Milltronics MSP-12, MSP-3, XPP-5 (0.25) dia. Hole for 1/4-20 bolt 95 (3.75) dia. Probe clearance hole 133 (5.25) 25 (1) 2" NPSL (0.25) dia. Hole for 1/4-20 bolt Note: Mounting flange supplied with probe. Mounting for Milltronics MSP-9 Panel (0.25) dia. Hole for 1/4-20 bolt 95 (3.75) dia. Probe clearance hole Probe flange (0.25) dia. Hole for 1/4-20 bolt Milltronics MSP-12, MSP-3, MSP-9, XPP-5 mounting, dimensions in mm (inch) Siemens FI 01 2018 /17

Standard Milltronics MSP-12 Heavy-duty general purpose motion probe Long lasting aluminum body with internal amplifier Convenient mounting flange and locknut for fast installation and setup Temperature rating: -40... +0 C (-40... +140 F) Enclosure rating: Type/NEMA 4X,, IP7 Milltronics XPP-5 CSA hazardous approval (Class I, Div. 1, Groups A, B, C, D; Class II Div. 1, Groups E, F, G; Class III) Aluminum body that is fully potted Convenient mounting flange and locknut 3/4" NPT male hub connection Operating temperature from -40... 0 C (-40... 140 F) Enclosure rating: Type/NEMA 4X,, IP7 High temperature Milltronics MSP-3 Heavy-duty, high temperature aluminum probe designed to withstand operating temperatures from -50... 20 C (500 F) Cast aluminum probe with convenient mounting flange and locknut 1.5 m (5 ft) of high temperature PTFE cable provided. Up to 30 m (100 ft) may be used. Amplifier remote mounted in enclosure 140 x 140 x 100 mm (5.5 x 5.5 x 4 inch), available in cast aluminum (½" NPT conduit entry), painted steel (Type/NEMA 4, IP5 rating), or stainless steel (Type/NEMA 4X, IP5 rating) Amplifier temperature rating -40... +0 C (-40... +140 F) Enclosure rating: Type/NEMA 4X,, IP7 Stainless high temperature Milltronics MSP-9 Heavy-duty, high temperature 304 stainless steel probe Special construction allows operation of probe in environment from -50... 20 C (500 F) 1.5 m (5 ft) special high temperature PTFE cable provided. Up to 30 m (100 ft) may be used. Amplifier remote mounted in enclosure 140 x 140 x 100 mm (5.5 x 5.5 x 4 inch), available in cast aluminum (½" NPT conduit entry), painted steel (Type/NEMA 4, IP5 rating), or stainless steel (Type/NEMA 4X, IP5 rating) Enclosure rating: Type/NEMA 4X,, IP7 Amplifier temperature rating -40... +0 C (-40... +140 F) Milltronics RMA (Remote Mounted Amplifier) Available for internal mounting within Probe, or in enclosure for remote mounting Enclosures available in cast aluminum (½" NPT entry), painted steel (Type/NEMA 4 rating) or stainless steel (Type/NEMA 4X, IP5 rating) Operating temp. from -40... +0 C (-40... +140 F) Enclosure rating: Type/NEMA 4X,, IP7 Milltronics motion probes Technical specifications Mode of operation Measuring principle Motion monitor and alarm Typical application Monitoring loss of motion in tail pulley, screw flights, bucket elevators Features Switch selectable overspeed or underspeed detection Setpoint adjustment: 0.15... 3 000 PPM Adjustable start-up time delay: 0... 0 seconds Visual indication of probe operation and relay status Output 2 relays working in unison, each providing 1 SPDT Form C relay contact, rated 8 A at 250 V AC resistive Performance Repeatability ± 1 % Dead band ± 0.25 % Dynamic Range Ambient Temperature Range Design Enclosure rating Enclosure dimensions Enclosure material Power Supply Certificates and approvals 0... 7200 PPM -20... +50 C (-5... +122 F) Type 4X/NEMA 4X/IP5 (standard and optional stainless steel) Type 4/NEMA 4/IP5 (optional mild steel) 10 x 240 x 82 mm (.3 x 9.5 x 3.2 inch) Optional: mild steel or 304 (1.4301) stainless steel 203 x 254 x 102 mm (8 x 10 x 4 inch) Polycarbonate Optional: mild steel or stainless steel 100... 240 V AC, 50/0 Hz, 15 VA, ± 10 % of rated voltage CE, RCM, EAC, KCC, CSA US/C, FM /18 Siemens FI 01 2018

MFA 4P Motion Failure Alarm Controller A highly sensitive single setpoint motion sensor system, used with MSP probes. 7MH7144-7 7 77 Milltronics RMA Remote Mounted Amplifier Remote mounted amplifier for Milltronics MSP-3 and MSP-9 motion sensing probes. 7MH7145-0 7 Click on the for the online configuration in the PIA Life Cycle Portal. Click on the for the online configuration in the PIA Life Cycle Portal. Enclosure NEMA 4X, polycarbonate enclosure 1 NEMA 4, painted mild steel enclosure 2 NEMA 4X, 304 (1.4301) stainless steel enclosure 3 Input Voltage 100... 240 V AC, ± 10 %, 50/0 Hz, 15 VA A Enclosure Aluminum enclosure, IP5, Type/NEMA 4X, ½" NPT entry Painted steel, Type/NEMA 4, IP5 rating 304 (1.4301) stainless steel enclosure, Type/NEMA 4X, IP5 rating A C D Speed detection version Standard, underspeed (U/S) or overspeed (O/S), A switch selectable Slow speed (S/S), U/S or O/S detection, B switch selectable (limit of 15 ppm) Approvals CE, RCM, EAC, KCC, CSA US/C, FM 2 Further designs Please add "-Z" to and specify Order code(s). Manufacturer s test certificate: According to EN 10204-2.2 Acrylic coated, stainless steel tag [9 x 50 mm (2.7 x 1.97 inch)]: Measuring-point number/ identification (max. 27 characters), specify in plain text Order code C11 Y15 Further designs Please add "-Z" to and specify Order code(s). Manufacturer s test certificate: According to EN 10204-2.20 Acrylic coated, stainless steel tag [38 x 51 mm (1.5 x 2 inch)]: Measuring-point number/ identification (max. 1 characters), specify in plain text Operating Instructions All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation Spare Parts Card, RMA Order code C11 Y18 7MH7723-1DT Painted mild steel, heated enclosure with viewing window for use down to -50 C (-58 ºF) (finished unit is mounted inside enclosure) [483 x 584 x 203 mm (19 x 23 x 8 inch)] A35 Stainless steel, sun/weather shield (finished unit is field mounted inside enclosure) [357 x 305 x 203 mm (14 x 12 x 8 inch)] S50 Operating Instructions All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation Spare Parts Transformer 7MH7723-1DX Circuit Card, standard 7MH7723-1DU Circuit Card, Slow speed 7MH7723-1DV Lid with overlay for MFA 4p 7MH7723-1GY Siemens FI 01 2018 /19

Milltronics Motion Sensing Probes 7MH714- A series of motion sensing probes used with the 7 7 7 MFA 4p. Milltronics MSP-3: heavy-duty, high temperature aluminum Milltronics MSP-9: heavy-duty, high temperature stainless steel Milltronics MSP-12: heavy-duty, general purpose Milltronics XPP-5: hazardous rated Note: Milltronics MSP-3 and MSP-9 probes require the use of Milltronics RMA (amplifier) Click on the for the online configuration in the PIA Life Cycle Portal. Cable Length Standard length (as described in Model options) 1) 0 Add Order code Y01 and plain text: "Total cable length... m" Extended cable length 2... 30 m (.... 98.4 ft) 2) 1 Extended cable length 31... 50 m 2 (101.7... 14 ft) 4) Extended cable length 51... 100 m 3 (17.3... 328.1 ft) 4) Model [standard cable length/type] MSP-3, ½" NPT cable inlet 3) B [1.5 m (5 ft) high temperature cable] MSP-9 [1.5 m (5 ft) high temperature cable] 3) 4) D MSP-12, ½" NPT cable inlet XPP-5 [1.5 m (5 ft) cable, (CSA Class I, Groups A, B, C and D; Class II Groups E, F, and G)] XPP-5 [10 m (32.8 ft) cable, (CSA Class I, Groups A, B, C, and D; Class II Groups E, F, and G)] E G H Further designs Please add "-Z" to and specify Order code(s). Total cable length: enter the total cable length in plain text description Acrylic coated, stainless steel tag [13 x 45 mm (0.5 x 1.75 inch)]: Measuring-point number/identification (max. 1 characters), specify in plain text Cable gland kit Manufacturer s test certificate: According to EN 10204-2.2 Operating Instructions All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation Spare Parts Locknut, for MSP-3, MSP-7, MSP-12, XPP-5 Mounting flange, for MSP-3, MSP-7, MSP-12, XPP-5 Mounting bracket for MSP-9 Lid, 1/2" NPT cable inlet for MSP-3, MSP-7, MSP-12 Lid for MSP-9 Lid gasket, for MSP-3, MSP-9 Lid gasket, for MSP-7, MSP-12 Motion cable gland adaptor kit Order code Y01 Y17 A57 C11 7MH7723-1CR 7MH7723-1CS 7MH7723-1CT 7MH7723-1CU 7MH7723-1CV 7MH7723-1CW 7MH7723-1CX 7MH7723-1JU XPP-5 [15 m (49.2 ft) cable, (CSA Class I, Groups A, B, C, and D; Class II Groups E, F, and G)] J Approvals CE, RCM, EAC, KCC A 1) No Y01 needed in Order code for standard length 2) Only available with model options B, D, G, H, J 3) MSP-3 and MSP-9 probes required the use of RMA (amplifier) 4) Available with Model options G, H, and J only /20 Siemens FI 01 2018

Dimensional drawings Type 4X/NEMA 4X/IP5 Polycarbonate Enclosure Type 4/NEMA 4/IP5 Painted Steel Enclosure & Type 4X/NEMA 4X/IP5 Stainless Steel Enclosure 10 (.325) 131 (5.138) Lid screws, 4 places 82 (3.225) 203 (8.0) 152 (.0) 273 (10.75) 254 (10.0) 19 (0.75) 228 (8.975) 240 (9.455) Suitable location for conduit entrances. Lid Enclosure Ø8 (0.31) 178 (7.0) 227 (8.94) 19 (0.75) Mounting holes 4.3 (0.17) diameter, Mounting screw 21 (0.83) Suitable location for Conduit Entrance (customer specified) Standard Probe MSP-12 0 (2.375) 127 (5) 187 (7.375) 2" NPSL Mounting flange Locknut Probe body Gasket 8 (3.375) Cap c/w 1/2" NPT conduit entrance Hazardous Locations XPP-5 ¾" NPT Cable Probe body (potted aluminum junction box) Probe body (potted aluminum housing) 2" NSPL Locknut 143 (5.3) 9.4 (0.37) 41.2 (1.2) 171.5 (.75) nominal Nameplate Mounting flange Milltronics MFA 4p and probe, dimensions in mm (inch) Siemens FI 01 2018 /21

High temperature probe MSP-3 0 (2.375) 2" NPSL Mounting flange Locknut Probe body Gasket 89 (3.5) 127 (5) 187 (7.375) 8 (3.375) 1/2" NPT tapped both sides Cap c/w 1/2" NPT conduit entrance 15 (.5) Mounting centers Ø 8 (0.312) 4 holes 111 (4.375) Mounting centers 140 (5.5) High temperature stainless steel probe MSP-9 Ø8 (3.375) Ø22 (0.875) 2 places 51 (2) Gasket Clamps 178 (7) 111 (4.375) Cap c/w Ø22 (0.875) hole 152 () 171 (.75) 191 (7.5) Mounting centers 152 () Ø8 (0.312) 4 holes Milltronics probes, dimensions in mm (inch) /22 Siemens FI 01 2018