HIGH CAPACITY TWO-STAGE PULSE TUBE

Similar documents
Pulse Tube Microcooler for Space Applications

Efficient High Capacity Space Microcooler

ABI Cooler System Protoflight Performance

MIRI Cooler System Design Update

Qualification of Lockheed Martin Micro Pulse Tube Cryocooler to TRL6

Characterization Testing of the Thales LPT9310 Pulse Tube Cooler

Small Scale Cooler: Extending Space Developed Technology into Adjacent Markets

Design of a Large Heat Lift 40 to 80 K Pulse Tube Cryocooler for Space Applications

Cryocooler with Cold Compressor for Deep Space Applications

Pressure Ratio Effect to Warm Displacer Type Pulse Tube Refrigerator

The Development of a New Generation of Miniature Long-Life Linear Coolers

Chart, Inc. Data Sheet 2s241K Cryocooler

Development of a High Frequency Pulse Tube

Experimental Investigation of a 40K Single Stage High Frequency Pulse Tube Cryocooler

High Capacity Flexure Bearing Stirling Cryocooler On-Board the ISS. Sassenage, France (2) THALES Cryogenics B.V. Eindhoven, The Netherlands

Overview of Micro-Miniature Stirling Cryocoolers for High Temperature Applications

Development of a High Frequency Pulse Tube

Data Sheet 2s102K Cryocooler

Gas Spring Effect in a Displacer Pulse Tube Refrigerator

An Advanced Compressor for Turbo-Brayton Cryocoolers

Reduction of Self Induced Vibration in Rotary Stirling Cycle Coolers

LPT6510 Pulse-tube Cooler for K applications

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Air Bearing Shaker for Precision Calibration of Accelerometers

Coaxial Pulse Tube Microcryocooler

Long Transfer Lines Enabling Large Separations between Compressor and Coldhead for High- Frequency Acoustic-Stirling ( Pulse-Tube ) Coolers

LOW SHOCK RELEASE UNIT EASY RESETTABLE AND 100 % REUSABLE. Jens Müller 1, Christoph Zauner 2

A Thermoacoustically Driven Two-Stage Pulse Tube Cryocooler

SPACE COOLER DEVELOPMENTS AT THALES CRYOGENICS TO FIGHT TRIBOLOGICAL FAILURE PHENOMENA

Physics 121 Practice Problem Solutions 11 Faraday s Law of Induction

Characterization Testing of Lockheed Martin Standard Micro Pulse Tube Cryocooler

Development of a 6W high reliability cryogenic cooler at Thales Cryogenics

CHAPTER 6 ENVIRONMENTAL CONDITIONS

The BEI OWL cooler is one of many in a family of linear Stirling-cycle cooler designs developed by the company.

GIMBALLING MAGNETIC BEARING REACTION WHEEL WITH DIGITAL CONTROLLER

Development of the LPT W Concentric Pulse Tube

Thermoacoustic Power Systems for Space Applications LA-UR

MECHATRONICS LAB MANUAL

NIRCam Filter Wheels

HIGH LOAD LOW SHOCK RELEASE UNIT (30 kn)

TE 91 PRECISION ROTARY VACUUM TRIBOMETER

PNEUMATIC HIGH SPEED SPINDLE WITH AIR BEARINGS

Ultra Series: Crossed Roller Ultra Precision Stages

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Fundamental Training. Flow Con t

An Automated System for the Acoustical and Aerodynamic Characterization of Small Air Moving Devices

Passive Vibration Reduction with Silicone Springs and Dynamic Absorber

FEASIBILITY STYDY OF CHAIN DRIVE IN WATER HYDRAULIC ROTARY JOINT

The Reduction of the Noise/Vibration Generated by the Discharge Valve System in Hermetic Compressor for Refrigerator

Preliminary vibration testing and analysis for automotive electronic control units

CRYOGENIC MOTORS FOR HERSCHEL/PACS AND JAMES WEBB/MIRI AND NIRSPEC

Ch 4 Motor Control Devices

Aspects of Permanent Magnet Machine Design

Procedia Engineering 00 (2009) Mountain bike wheel endurance testing and modeling. Robin C. Redfield a,*, Cory Sutela b

Development of a Dual Mode Vibration Isolator for a Laser Communication Terminal

Driving Characteristics of Cylindrical Linear Synchronous Motor. Motor. 1. Introduction. 2. Configuration of Cylindrical Linear Synchronous 1 / 5

Clearance Loss Analysis in Linear Compressor with CFD Method

Active Control of Sheet Motion for a Hot-Dip Galvanizing Line. Dr. Stuart J. Shelley Dr. Thomas D. Sharp Mr. Ronald C. Merkel

产品技术规范. Product Name: Product Technical Specification SMARTSTONE. No.: CPFL0002 Version: A Issued date: Page 1 of 16

Performance of Small-Gap Undulators at the SLS Intermediate Energy Storage Ring

Low Vibration Microminiature Split Stirling Cryogenic Cooler for Infrared Aerospace Applications

USA FALCON 1. Fax: (310) Telephone: (310) Fax: (310) Telephone: (310) Fax: (310)

Eliminating the Need for Payload-specific Coupled Loads Analysis

Diesel-Driven Compressor Torque Pulse Measurement in a Transport Refrigeration Unit

Introduction. 1/2 Overview 1/3 Benefits 1/3 Application. 1/3 Order No. code. 1/4 Protection strategy

Displacement Sensor. Model 8739, 8740, 8741

Linear Shaft Motors in Parallel Applications

Alan R. Klembczyk, Chief Engineer Taylor Devices, Inc. North Tonawanda, NY

MICRO VIBRATION IMPROVEMENT OF A STEPPER ACTUATED MECHANISM

test with confidence HV Series TM Test Systems Hydraulic Vibration

Environmental Qualification Test Report for Spider S3/S5

The Piezoresistive Pressure Transducer

COMPARISON OF PERFORMANCE FEATURES

STT280 SEALED TILT SENSOR

MGA Research Corporation

APS 400 ELECTRO-SEIS. Long Stroke Shaker Page 1 of 5. Applications. Features

IOP Conference Series: Materials Science and Engineering. Related content PAPER OPEN ACCESS

APS 420 ELECTRO-SEIS Long Stroke Shaker with Linear Ball Bearings Page 1 of 5

Magnetostriction in Automotive Position Measurement

DEVELOPMENT OF AN EUROPEAN EDDY CURRENT DAMPER (ECD-100)

ASTM D4169 Truck Profile Update Rationale Revision Date: September 22, 2016

Introduction to Vibration & Pulsation in Reciprocating Compressors

LOW SHOCK NON-EXPLOSIVE ACTUATOR

Lab Electrical Power Engineering I

Titre / Title HIGH RELIABILITY RF COAXIAL LOADS AND ATTENUATORS GENERIC SPECIFICATION

AUTOMOTIVE MAINTENANCE TECHNOLOGY SUBJECT : AUTOTRONIC 2 TITLE: TRANSISTORISED IGNITION WITH HALL GENERATOR TI-H

DSX-Series Vibration

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

Design and Analysis of Hydrostatic Bearing Slide Used Linear Motor Direct-drive. Guoan Hou 1, a, Tao Sun 1,b

LRQ-DE Series Datasheet

Fugitive Emissions Standards & Laboratory Test Methods for Valves

Piezoelectric Direct Drive Servovalve

MAIN PORT MECHANISM FOR PRISMA

S-SERIES DISPLACEMENT TRANSDUCERS

Extruded Positioning Stage

Condition Monitoring of a Check Valve for Nuclear Power Plants by Means of Acoustic Emission Technique

Clearance Seal Compressors with Linear Motor Drives Part I: Background and System Analysis

Development of a High Efficiency Induction Motor and the Estimation of Energy Conservation Effect

M. A. Green, and S. Yu Lawrence Berkeley National Laboratory, Berkeley CA 94720, USA

Lecture 19. Magnetic Bearings

Transcription:

HIGH CAPACITY TWO-STAGE PULSE TUBE C. Jaco, T. Nguyen, D. Harvey, and E. Tward Northrop Grumman Space Technology Redondo Beach, CA, USA ABSTRACT The High Capacity Cryocooler (HCC) provides large capacity cooling at both 35 K and 85 K for space applications in which focal planes and optics require cooling. The compressor is scaled from the High Energy Cryocooler (HEC) compressor and is capable of using input powers up to 700 W. The two linear pulse tube cold heads are integrated with the compressor into an integral cryocooler. A thermal strap between the cold heads improves efficiency and can be positioned to provide cooling for a wide range of applied loads. The cooler has undergone acceptance testing that includes thermal performance mapping over a range of reject temperatures and power levels and launch vibration testing. In addition to the acceptance testing, self induced vibration measurements were made over a range of reject temperatures and power levels. INTRODUCTION The High Capacity Cryocooler (HCC) as shown in Figure 1 is a two-stage pulse tube cooler developed to provide a long life, low mass, higher efficiency space cryocooler on missions such as Space Tracking and Surveillance System. The cooler has an objective to extend the performance of proven, high efficiency, lightweight pulse tube cooler technology to larger capacity, lower temperature and staged operation. FIGURE 1. Two-Stage High Capacity Cryocooler

Because of its high efficiency and very low mass/unit capacity, the HCC can be applied to simultaneously cool long wave infrared (LWIR) focal planes (as low as 30 K) and optics (60 K to 150 K). Although the HCC was designed to cool 2 W @ 35 K and 16.5 W @ 85 K, the variable position strap between the coldheads allows for a broad range of applied loads and temperatures. As delivered, the strap location provides cooling of 1.8 W @ 35 K and 19 W @ 85 K with an input power of 530 W, centerplate temperature of 300K and reject temperature of 285 K. The HCC achieves low input power and large cooling load because of the efficiency of its pulse tube cold heads and its efficient compressor. The low mass results from the use of the second-generation flexure compressor technology developed with Oxford University and productionized for Northrop Grumman by Hymatic Engineering [1]. CRYOCOOLER The cooler characteristics are summarized in Table 1. The HCC two-stage cold heads are designed in an integral parallel configuration. In this design, the 1 st and 2 nd stage cold heads are mounted directly on the compressor center plate. The oscillating flow from the compressor is split into the two cold heads in proportion to their required thermal design performance. The parallel two-stage cold head configuration has the advantage that there is minimal interference in the thermal performance of the two stages, i.e., changes in cooling at one stage has a small effect on the other stage. TABLE 1. Typical Cooler characteristics Cooling load at 85 K Cooling load at 35 K Input power Centerplate temperature Maximum input power capability Cooler mass 19.0 W 1.8 W 530 W 300 K 700 W 14.3 kg The two-stage cold head is mounted onto a back-to-back compressor, designed to achieve both long lifetime and vibration balance. The flexure springs are very stiff in the direction perpendicular to the driven motion (much stiffer than gas or magnetic bearings) so that close tolerance gas gap seals can be maintained and wearing seals can be eliminated. The flexures themselves are designed for maximum stress levels well below the material endurance limits. Their reliability is validated in the compressor since over 10 7 cycles are accumulated in 4 to 5 days with these compressors. The working fluid is dry helium with no lubricants. The drive is a direct voice coil motor similar to a loudspeaker drive, thereby eliminating linkages. The cooler components are shown in Figure 2. The linear cold heads are attached to the centerplate and hermetically sealed with a metal C-ring. The cold heads containing the regenerators, cold blocks, pulse tubes and orifice blocks are mechanically supported against launch loads by a support structure. The two 6.45 cm 2 cold block interfaces are gold plated and located near the midpoint of the cold heads. The 35 K cold head is provided with redundant calibrated platinum resistance thermometers used for temperature control. The thermal strap between the 85 K cold block and the 35 K regenerator provide overall system power reduction. Centerplate temperature is measured using a thermistor bonded to the top of the centerplate between the coldheads. Also located on the centerplate

Structural and thermal support 85K linear cold head Secondary heat rejection surface 35K linear cold head Inertance line Reservoirs Balanced compressor FIGURE 2. Cooler components is an accelerometer that is used to sense cooler self-induced vibration. The accelerometer preamplifier, which is mounted on the centerplate, amplifies the accelerator signal for transmission to the control electronics. Here it is used as an error signal in a feedback loop to reduce the vibration to very low levels. The compressor end caps, which also enclose the reservoir, are hermetically sealed by metal C-rings. The centerplate incorporates simple and effective mechanical and thermal interfaces to payloads. The primary mechanical mounting interfaces of the compressor can adequately remove up to 400 W of heat by direct conductive heat transfer to the mount surface. For greater input powers to the 700 W limit, a secondary thermal interface is provided for extra heat removal capability. After assembly, the bake out process performed on the cooler reduces volatile condensables and water in the machine to negligible levels. All Northrop Grumman coolers are hermetically metal sealed to have minimum detectable leakage rates of helium fluid. The processes have been verified by life tests of similar pulse tube coolers and in-flight history of the eleven other Northrop Grumman pulse tube units that are currently in orbit. COOLER PERFORMANCE Figure 3 shows a typical performance map of the two-stage cooler at fixed input power and reject temperature. Note that as the applied load on the higher temperature coldhead (stage 1) is reduced from the maximum value shown of 19 W to 0 W, the temperature of the lower temperature coldhead (stage 2) with constant load of 1.8 W is affected by only 2.5 K. Similarly when the load on the stage 1 is held fixed and the load on stage 2 is varied from 1.8 W to 0.4 W, the stage 1 temperature varies by less than 1.5 K. This implies that the thermal performance of each cold head is independent of the other. In a parallel

multistage configuration, there is little interference between the stages. This is very important in reducing risk for an immature payload design. Figure 4 shows a typical performance map of the HCC cooler as a function of the input power with a given strap location. As the input power is reduced, the cooling loads are reduced while maintaining the efficiency of the system. In these measurements the HCC cooler maintains its efficiency as the input power is reduced from 500W to 178W. The HCC cooler can be optimized at different first stage cooling temperatures. Table 2 summarizes the performance at two cooling loads at 35 K and different temperatures of the first stage. The High Capacity Cryocooler has undergone acceptance test prior to its delivery to the Air Force. The complete suite of acceptance tests include thermal performance mapping over a wide range of reject temperatures and power levels, launch vibration testing and thermal vacuum tests. The engineering model cooler was tested under the random launch vibration conditions shown in Figure 5, that are acceptance levels. The overall random vibration level is 8.65 Grms. The cooler was also acceptance tested under different thermal conditions. The thermal cycle profile is shown in Figure 6a. Thermal cycle test data is shown in Figure 6b. Extensive thermal and dynamic analyses were conducted on the HCC. The results of the analyses are summarized in Table 3. Additionally, the self-induced vibration of the cooler was measured at various centerplate temperatures and input powers. The 500W/300K results are shown in Figures 7-9 for each of the three axes. The self induced vibration was measured with the cooler mounted inside a bell jar attached to a force plate with four force transducers. The fundamental and harmonics are labeled on the plots in order to distinguish them from the background noise of the vacuum pump and cooling water recirculator. The background noise disappears when the laboratory support systems are not operating, but the cooler operating time during test is then limited. 36 Stage 1 Load 19.0 W Stage 2 Load 1.8 W 35 Stage 2 Coldblock Temperature (K) 34 33 32 Stage 1 Load 0 W Stage 2 Load 1.8 W 31 Stage 1 Load 0 W Stage 2 Load 1.2 Stage 1 Load 18.9 W Stage 2 Load 0.4 W 30 40 45 50 55 60 65 70 75 80 85 90 Stage 1 Coldblock Temperature (K) FIGURE 3. Two stage cold head performance map

2.5 25 2.3 2.1 Cooling Load at 35K Cooling Load at 85K 20 Cooling Load at 35K, Watts 1.9 1.7 1.5 1.3 1.1 15 10 Coolong Load at 85K, Watts 0.9 5 0.7 0.5 0 0 100 200 300 400 500 600 700 Compressor Input Power, Watts FIGURE 4. Two stage cold head performance as function of input power TABLE 2. HCC performance at different temperatures of first stage Stage 1 Temperature Stage 1 Load Stage 2 Temperature Stage 2 Load Input Power 85 K 16.8 W 35 K 2 W 501 W 111 K 12.55 W 35 K 0.7 W 209 W TABLE 3. Thermal, stress and dynamic margin for qualification levels Components Requirement Capabilities Center Plate Temperature Rise @ 400W < 20 K 16.7 K Interface Heat Flux @ 400W < 25 W/in 2 17.6 W/in 2 85 K Cold Head Safety Factor (Yield) Safety Factor (Ultimate) Margin of Safety (Q=90) 1 st Mode 35 K Cold Head Safety Factor (Yield) Safety Factor (Ultimate) Margin of Safety (Q=90) 1 st Mode >1.5 >2.5 >0 >250 Hz >1.5 >2.5 >0 >250 Hz 4.4 5.9 1.55 770 Hz 2.8 3.2 0.27 511 Hz H-Bar 1 st Mode >250 Hz 594 Hz

0.1 PSD, (g2/hz) 0.01 10 100 1000 10000 Frequency, (Hz) Figure 5. Random Vibration Profile TABLE 4. Random Vibration Test Power Spectral Density Frequency (Hz) Reference Fig. 4.2 Acceptance (G 2 /Hz) 20 G20 0.014 70-800 Ghigh 0.050 2000 G2000 0.020 Overall 8.65 Grms Duration, per axis 1 minute

Temperature ( o C) 70 60 50 40 30 20 10 0-10 -20 Non-Operating 2 hours Non- Operating < 2 o C/min 0 24 Operating 1 hour He Leak and Functional Test Operating 1 hour He Leak and Functional -30-40 -50 Non-Operating 2 hours Figure 6a Thermal Cycle Test Profile Time (hr) Operating - 3 cycles 340 320 300 280 260 240 HCC Thermal Cycle Data February 2005 Stage 1 Cold Block Stage 2 Cold Block Centerplate Temperature (K) 220 200 180 160 140 120 100 80 60 40 20 0 5 10 15 20 25 30 35 40 45 50 Time (hours) Figure 6b Thermal Cycle Test Data

10000 HCC Self Induced Vibration 500 W Input Power 300 Centerplate Temperature February 2004 Fx Spectrum, Off-axis Harmonics 1000 131.25 282.71 Force (mn) 100 43.75 Hz 35.61 mn 218.75 19.95 262.50 15.83 350.00 43.62 393.75 43.02 437.50 20.67 10 87.50 16.37 306.25 7.71 1 175.00 2.86 0 50 100 150 200 250 300 350 400 450 Frequency (Hz) Figure 7 Self-induced Vibration: Off-axis Data 10000 HCC Self Induced Vibration 500 W Input Power 300 Centerplate Temperature February 2004 Fy Spectrum, Drive axis Harmonics Force (mn) 1000 100 43.75 Hz 170.06 mn 87.50 101.23 131.25 367.52 175.00 37.81 218.75 40.47 306.25 23.74 350.00 21.13 437.50 10.76 10 262.50 8.10 393.75 21.05 1 0 50 100 150 200 250 300 350 400 450 Frequency (Hz) Figure 8 Self-induced Vibration: Drive-axis Data

10000 HCC Self Induced Vibration 500 W Input Power 300 Centerplate Temperature February 2004 Fz Spectrum, Coldhead axis Harmonics 1000 43.75 Hz 766.88 mn 87.50 293.12 131.25 834.83 Force (mn) 100 218.75 129.80 262.50 73.69 306.25 60.73 350.00 35.10 10 175.00 19.04 393.75 27.57 437.50 10.50 1 0 50 100 150 200 250 300 350 400 450 Frequency (Hz) Figure 9 Self-induced Vibration: Coldhead-axis

ACKNOWLEDGEMENTS This work was sponsored by the MDA. This work was performed for the Air Force Research Laboratory, Kirtland, NM, under contract number F29601-01-C-0226. The support of Thom Davis and Adam Smith is gratefully acknowledged. REFERENCES 1. Tward, E., Chan, C. K., R., Colbert, Jaco, C., Nguyen, T., Orsini R., Raab, J., Adv. In Cryogenic Engineering, Vol. 47B, p. 1077 (2002). 2. Chan, C.K, Nguyen, T., and Jaco, C., Two-stage pulse tube cooler Crycoolers 12, edited by Ronald G. Ross Jr., Kluwer Academic/ Plenum Publishers, New York 2003, pp219-224.