Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Similar documents
Model &

Flojet Rewrites the Book on Small Pump Control

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

Model 21OO lndustrial Series

Troubleshooting WARNING

08 general Purpose Pumps

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

50830 Series Low Pressure Centrifugal Pump

FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions

PowerFLO 5800/5900 Series

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 3 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 80. A JDA Global Company

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

Models XXX XXX

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

05 Water Pressure Systems INTRODUCTION

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 2 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 50 BOLTED. A JDA Global Company

OPERATION MANUAL.25 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev.

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

OPERATION MANUAL NT80 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS .5 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 15

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

M-3025CB-AV Fuel Pump

SAFETY MANUAL READ FIRST!

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

HFP-2.2 G.P.M. PRO SERIES HIGH-FLO 12 VOLT PUMPS 68 PUMPS

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL. Model: FSUTL60-12V ( ) Technical Specifications. Assembly Instructions

OWNER S MANUAL. Model: FSUTL40-12V ( ) Technical Specifications. Assembly Instructions

Agriculture Pumps and Accessories

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1

OPERATION MANUAL. DUCTILE Models NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2

Material required for drilled well application (indoor use only)

Features and Benefits Wide Bottom: Translucent Bottle: 2 1/2 Gallon Bottle: Removable Bottle: Large cap: 15 Feet of Coiled Hose:

Marine Pumps & Accessories

SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

SHURFLO AQUA KING II STANDARD 3.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

WORKHORSE. Assembly / Operation Instructions / Parts 15 & 25 GALLON SPOT SPRAYER

OPERATOR S MANUAL A

SUNC3000 / Item #40885

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

1/2" AIR DRIVEN DIAPHRAGM PUMP

GARDEN HOSE UTILITY PUMP

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

INDUSTRIAL PUMP 8000 SERIES

12 Volt DC Diaphragm Pumps Series 400

6 Litre Oil-Less Air Compressor

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

6L Oil-less Air Compressor 53103

Owner's Manual. Model: UTL-60-12V ( ) (60 Gallon Utility Sprayer w/ 5-Nozzle Boom Assembly) Technical Specifications.

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

100 Gallon Skid Sprayer

OWNER S MANUAL. Model: UTV-65-BL ( ) (65 Gallon Lawn & Garden UTV Sprayer w/boomless Boom)

SUPER PUMP OUT SYSTEM

ProFlo FatBoy

40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK

WORKHORSE. Assembly / Operation Instructions / Parts

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

Models Series Series

INDUSTRIAL PUMP 8000 SERIES

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

Troubleshooting 3Z8 038 Rev B

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

Fast-Flo Pump INSTRUCTIONS-PARTS LIST. Table of Contents 1:1 RATIO

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

PureSine 150/300 Pure Sine Wave Inverter User s Manual

Owner's Manual. Model: ATV QR ( ) *** IMPORTANT REMINDER *** (25 Gallon Lawn & Garden/ATV Sprayer w/standard 7-Nozzle Boom Assembly)

MODEL SS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions

US - UP2/OIL 12V US - UP2/OIL 24V

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

MODEL CJ-95 CoilJet Portable HVAC Coil Cleaning System

Rev: Flow Max 115V AC Fluid Pump

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

herkules 338 Air Operated Diaphragm Pump

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

MODEL CJ-200E CoilJet Portable HVAC Coil Cleaning System

Owner's Manual. Model: ATV-20-2-QR ( ) (20 Gallon Lawn & Garden/ATV Sprayer) Technical Specifications. Assembly. General Information

OWNER S MANUAL. Model: FSUTV-45-12V ( ) (45 Gallon Lawn & Garden UTV Sprayer, Boom Ready) Technical Specifications. Assembly Instructions

#9040 FUEL TANK SWEEPER

50 Gallon Skid Sprayer

WORKHORSE. Assembly / Operation Instructions / Parts DELUXE ATV BOOMLESS SPRAYER

HEAVY DUTY ONBOARD AIR SYSTEM

SERVICE MANUAL 200 SERIES MOTORIZED 20352, 20452, 20551, 20552, AND MODELS

OPERATOR S MANUAL SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

1600 PSI ELECTRIC PRESSURE WASHER

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

OWNER S MANUAL. Model: ATV ( ) ***IMPORTANT REMINDER*** Technical Specifications. Assembly Instructions. General Information

Calcium Chloride Pump

Transcription:

Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact Size Quiet Running PumpAgents.com - Click here for Pricing/Ordering Snap-in Port Adapters Flow to 3 GPM/12 LPM Conforms to Electromagnetic Compatibility 89/336/EEC and Machinery Directive 89/392/EEC, EN50081-1 115 VAC INDUSTRIAL DIAPHRAGM PUMPS SPECIFICATIONS Materials Pump Body Glass-filled Polypropylene Diaphragm Santoprene** Valves Viton*or EPDM Hardware Stainless Steel Pump Design Four Piston Diaphragm Type Pressure Switch OFF at 40 psi ON at 25 psi Motor AC Capacitor Start Induction Motor Fan Cooled, Sealed Ball Bearing Thermally Protected, 115VAC, 60Hz, 1ø 1.8 Amp, CSA, UL listed Continuous 25 psi (1.7 Bar) at 75 F (24 C) Ambient Duty Rating Ports 1/2" (13 mm), 1/2" Male Quest, EPDM O-ring Liquid 45 F (7 C) to 130 F (54 C) Temperature For use with Maximum 130 F (54 C) Water Viscosity 250 Centipoise Maximum Shipping Weight 12 lb (5.5 kg) Not designed for outdoor use. Protect from direct splash and spray. Provide adequate ventilation. APPLICATIONS This pump provides excellent service where 115VAC 60hz single-phase power is required for operation. The AC capacitor start induction motor dramatically extends motor service life in applications where permanent magnet DC motors would require regular maintenance to replace worn motor brushes. This pump is the clear choice for continuous duty bulk transfer and recirculation applications. Recommended for use with mild acids and bases compatible with the materials of construction. Typical applications include chemical feed, chemical transfer, coolant re-circulation, condensate removal, tank agitation, thermal mixing, filling, flushing, and washdown applications. Pump will self-prime and can be mounted up to 9 feet above the liquid supply level. Pump can run dry without damage. Built-in pressure switch automatically turns pump off when discharge valve is closed. Snap-in ports for easy installation and maintenance. Optional 40 mesh inlet strainer mounts directly to suction port, and is available with 1/2" or 3/4" hose barb connection. Not for use with gasoline or other flammable liquids. Not for use where flammable vapors are present. Pump must be properly grounded and protected from direct contact with water or other liquids. Models Flow Hertz and Pressure AMP Draw GPM (LPM) Voltage Phase Switch Valves Diaphragm @ 10 psi 31801-0115 3 (12) 115 VAC 60 Hz, ø1 40 PSI Viton* Santoprene** 1.1 31801-1305 3 (12) 115 VAC 60 Hz, ø1 40 PSI EPDM Santoprene** 1.1 * Viton is a registered trademark of DuPont Dow Elastomers L.L.C. ** Santoprene is a registered trademark of Monsanto.

OPERATING INSTRUCTIONS Explosion hazard. Do not pump gasoline or other flammable liquids. To do so can cause an explosion resulting in injury or death.! WARNING Fire hazard. Wiring must comply with applicable electrical standards and include a properly sized fuse or circuit breaker. Improper wiring can cause a fire resulting in injury or death. 1. MOUNTING JABSCO diaphragm pumps are selfpriming and may be located in a dry location above or below the fluid supply. To vertically mount these units, it is best to do so with the motor on top. This will prevent fluid dripping on the motor in the event of a leak. Place pump on a solid surface and secure with four mounting screws being careful not to fully compress the rubber grommets which act as shock absorbers. 2. PLUMBING 1/2" (13 mm) straight hose barb and 1/2" Quest straight port adapters are supplied to fit 1/2" inside diameter hose and 1/2" nut and ferrule installations. Note that Quest fittings are not designed to fit NPT tapered pipe fittings. Use adapter kit 20381-040J with 1/2" male pipe threads for NPT pipe installations. Use 1/2" ID hose and 1/2" fittings minimum. Use hose clamps to prevent air and liquid leaks. Connecting the pump directly to rigid pipe is not recommended. If rigid pipe is used, install a short piece of flexible hose between the pipe and pumphead to eliminate undue mechanical stress on the port fittings. Use a 40 mesh strainer to prevent dirt and debris from entering the pumphead. Use inlet strainer 01740-012J for 1/2" hose barb connection or 01740-004J for 1/2" Quest connection. Periodically clean strainer screen. 3. ELECTRICAL CONNECTION Place ON/OFF switch in OFF position before connecting to wall outlet. Pump must be connected to a properly grounded 3 prong electrical receptacle. Remove power from pump prior to disassemble or maintenance. 4. SELF-PRIMING Pump is self-priming. Vertical dry lift capacity is 9 ft (2.7 m). Be sure suction piping is airtight or pump will not self-prime. 5. RUNNING DRY Pump can run dry indefinitely without damage. 6. CHEMICAL COMPATIBILITY Use with fluids compatible with the materials of construction. Consult factory for Chemical Compatibility Guide. Pump should be flushed with clean water or neutralizing solution after each use to prolong pump life. 7. TEMPERATURE The maximum recommended fluid temperature is 130 F (54 C). Minimum recommended fluid temperature is 45 F (7 C). 8. VISCOSITY The maximum recommended viscosity is 250 centipoise. 9. DUTY CYCLE Motor and pump are designed for continuous operation in a 70 F (21 C) ambient air while pumping against 30 psi (2 bar) discharge pressure. Beyond these parameters an intermittent duty cycle is recommended to maximize pump life. In normal operation, motor case will get hot. Prolonged contact with motor could cause a burn on human skin. 10. START-UP AND OPERATION Check level of fluid in supply tank. Open all valves in system. Switch pump electrical circuit to ON position. Close discharge valve after flow becomes steady. Pump will shut off soon after closing valve. Pump is now ready for automatic operation. Pump will start when outlet valve is opened and stop when valve is closed. If pump is to be inoperative for a considerable period of time, flush pump with water, turn off electrical circuit to pump, and bleed system pressure by opening discharge valve. Do not allow liquid to freeze inside pumphead. Damage to pump may occur. SERVICE INSTRUCTIONS PUMP DISASSEMBLY 1. Remove power from pump. Open discharge valve to relieve system pressure. 2. Push port clips back and disconnect plumbing from pump. 3. Remove the four (4) pumphead screws. 4. Rotate pumphead until cam/bearing set screw is visible through drain notch. 5. Loosen cam/bearing set screw and slide pump off motor shaft. 6. Separate upper housing, lower housing, and check valve assembly as required. PUMP ASSEMBLY 1. Install new outer piston in lower housing with piston tops pointing away from motor. 2. Install new diaphragm in lower housing with the molded O-ring seals facing away from motor. 3. Insert each inner piston through the diaphragm into outer piston. 4. Turn each piston until fully seated. 5. Secure cam/bearing assembly to outer pistons using 18 inch pounds (2.0 Nm) of torque. 6. Slide lower housing on motor shaft. Align set screw with motor shaft indentation. 7. Set screw MUST be positioned over shaft indentation and secured tightly. 8. Check that ferrules are installed in upper housing and O-ring is properly seated. 9. Install check valve assembly in upper housing and fit upper and lower housings together. 10. Align pumphead with motor and tighten four (4) screws evenly using 25 inch pounds (2.8 Nm) of torque. servicing. To reduce risk of shock, pull plug before To reduce risk of electric shock, connect only to a properly grounded, grounded-type receptacle. Pumps have thermal overload protected motors. The motor will automatically shut off if temperature rises due to an overload condition. If the motor shuts off in this manner, turn pump off. Restart pump after motor cools. If pump is not manually turned off after thermal shutdown, pump may turn on unexpectedly when motor cools.

Total Pressure in PSI (bar) Amps SWITCH REPLACEMENT 1. Remove power from pump. Relieve system pressure. Disconnect inlet and outlet hoses. 2. Remove pressure switch cover and disconnect power leads from switch. 3. Remove switch and switch diaphragm from pump by removing two (2) switch mounting screws. 4. Replace switch diaphragm and switch. Reassemble in reverse order. 5. Do not over tighten switch mounting screws. OPTIONAL PORT KITS PERFORMANCE CURVES 50 40 30 20 10 (3) (2) (1) 3 2 1 30649-1004 1/2" Male Quest EPDM O-ring 30653-1004 3/4" Straight 30654-1004 1/2" Straight 30642-1004 90-3/4" 30651-1004 90-1/2" 0 0 0 1 2 3 4 (3.8) (7.6) (11.4) (15.1) Flow in U.S. GPM (LPM) Port Kits contain two ports with O-rings EXPLODED VIEW 5 1 2 3 8 4 9 PARTS LIST 1 2 3 4 5 8 Model Upper Check Diaphragm Cam/Bearing Motor Pressure Housing Kit Valve Kit Kit Kit Kit Switch Kit 31801-0115 18910-4007 18911-7020 18912-3040 18913-0003 18919-2125 18916-0118 31801-1305 18910-4007 18911-7030 18912-3040 18913-0003 18919-2125 18916-0118 Bearing cover 9 not included in diaphragm Kit 3

DIMENSIONS Inches (millimetres) 30801 MODELS 3-1/4 (82.5) 5-5/8 (143.0) 3-13/16 (96.8) 2-9/16 (65.1) 1-11/16 (42.9) 3-1/8 (79.4) 10-7/8 (276.0) 4-9/16 (116.0) 5-3/8 (137.0) 3-7/16 (87.3) 4-3/8 (111.0) 4X 1/4 (6.4) 4X 5/16 (7.9) TROUBLESHOOTING PULSATING FLOW Pump cycles on and off Restricted on outlet remove restriction or increase nozzle size FAILURE TO PRIME Motor operates, but no pump discharge Restricted intake or discharge line Air leak in intake line Debris under check valves MOTOR FAILS TO TURN ON Loose wiring connection Pump circuit has no power Blown fuse Thermal Protector Tripped Pressure switch failure Defective motor PUMP FAILS TO TURN OFF After discharge valve is closed Empty water tank Discharge line leak Defective pressure switch Low voltage to pump Debris under check valves LOW FLOW AND PRESSURE Air leak at pump intake Debris inside pump in check valves Worn bearing (excessive noise) Defective motor THE PRODUCTS DESCRIBED HEREIN ARE SUBJECT TO THE JABSCO ONE YEAR LIMITED WARRANTY, WHICH IS AVAILABLE FOR YOUR INSPECTION UPON REQUEST.

For technical advice or service please take your pump into your local pump service center. To order pump or parts or for pricing please go to the following links : Jabsco Pumps Home >> Jabsco Pumps stock list >>