Series CC Condensate Units

Similar documents
Domestic. Pump Series CS Condensate Units SINGLE OR DUPLEX 1,000 THRU 150,000 SQ. FT. EDR-250 THRU 37,500 LB./HR.

TYPE PC Propeller Condensate Pumps

W4100, W4200 & W4300 Electric Pump

SERIES WC & WCS. Watchman Series & WCS Condensate Units. Replacement Parts for. Hoffman PARTS LIST DN0436. Hoffman Pump

SUBMITTAL DATA WATER PRESSURE BOOSTER SYSTEMS

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

SECTION H3 TRAYMASTER SERIES DEAERATORS

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

Hydropak Booster Systems. Series motralec

SECTION H4 BOILERMATE DEAERATORS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Duplex Commercial Pressurizer -DCP

Packaged Design Day Tank Systems

SAMPLE SPECIFICATIONS

MODEL 10LH SPECIFICATION

M20 Duplex Pump Data C8 Controller Data Sheet

OPTIONS. Catalog Number (July. 2017) The content herein is subject to change without notification. OP-1

University of Houston Master Construction Specifications Insert Project Name

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

Product Numbering System Typical Specifi cations, Models 4AC, 4AE, 6AC, 6AE, 8AC Pump Assembly, Types AC & AE

Automatic Self-Cleaning Strainer/Filter Systems

3x3x7B Series 80 In-Line Mounted Centrifugal Pumps

Models & Options Lubrication. 1/2 Through 10 Hp Models 1Ø 3Ø 1/2 Through 10 Hp Models 1Ø and 3Ø

Regenerative Turbine Pumps

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

4700 SERIES. Technical Specifications. Condensate Units - Cast Iron Tank. Features

Series MSC Sewage Chopper Pumps

Series 774 Automatic Skid Package

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Hoffman Specialty General Catalog

Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION. Packaged Pump Sets for Diesel/Fuel Oil Application Page 1

ITT. Goulds Pumps. AquaForce PRESSURE BOOSTING SIZING GUIDE. Engineered for life. Building and Municipal Applications.

September 22, 2016 To: All Contractors Re: Boiler Back-Up Fuel Tank System Renovation. Dear Sir:

Multiple vacuum pumps and associated equipment ASME air receiver NEMA 12 multiplex control panel

Deep Well Pump Control Valve

Inspection, Testing, and Maintenance Fire Pumps NFPA 25, Chapter 8 as amended by CCR, Title 19 Page 1 of 8

Tank Filling Systems. for Petroleum Products

STEAM TRAPS. Inverted Bucket Steam Traps (continued) Series B. Dimensions in. (mm)

FLOMAX SELF PRIMING CENTRIFUGAL PUMP FEATURES. 3 MP PUMPS, INC. PHONE: (800) FAX: (586) FLOMAX 5 FLOMAX 8

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

5GB, 7GB, 10GB, 18GB, 25GB, 33GB

CIRCULATION HEATERS SPECIFICATIONS DESCRIPTION FEATURES CH & CHP SERIES HEAT EXCHANGE AND TRANSFER, INC. 6 to 480 kw and higher. Flanged construction

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY

M50 L50 Series Multistage Regenerative Turbine Pumps

Regenerative Turbine Pumps

Automatic Self-Cleaning Strainer/Filter Systems

PATTERSON PUMP COMPANY

Regenerative Turbine Pumps

Consider The Possibilities...

Updated: October 2012

2 30 HP RECIPROCATING AIR COMPRESSORS. R-Series

Series

D51 D61 D71 D91 Series

SERIES: WG6-2 SELF-PRIMING CENTRIFUGAL PUMPS

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

Six-Inch Submersible Pumps

High Level Alarm Panel

Multiple vacuum pumps and associated equipment ASME air receiver NEMA 12 multiplex control panel

UD SERIES COMPRESSORS

Minuteman Vertical Pumps

ITT. Goulds Pumps. 5GB, 7GB, 10GB, 18GB, 25GB, 33GB High Pressure Multi-Stage Booster Pump. Engineered for life. Residential Water Systems FEATURES

3800 Series. Single Stage End Suction Pumps. Capacities to 4200 G.P.M. (954 m 3 /hr) Heads to 520 Feet (180 Meters) Temperatures to 300 F (149 C)

Bell & Gossett Parts List CP-302F-PL. Replacement Parts for Series 1522 Uni-Built Centrifugal Pumps

Duplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, with Steel Cover

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

CLOSED COUPLED CENTRIFUGAL PUMPS

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

Tank Filling Systems for Petroleum Products

Series: G5-1¼, G6-1¼ RPM - 60Hz. CAPACITIES TO 80 GPM (5 LPS) HEADS TO 135 FEET (41 M)

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

1SV (e-sv) 60 Hz 3500 RPM

20EVP-A SERIES. Vertical In-Line Self-Priming Centrifugal Pumps for Petroleums and Solvents. Marlow Pumps. Marlow Pumps.

Reliant Series Systems Fuel Tanks DAY TANKS FILTRATION TANKS SPECIALTY TANKS

CLOSED COUPLED CENTRIFUGAL PUMPS

Smart controls Reliable operation User friendly design Plug and play operation

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover

CLOSED COUPLED CENTRIFUGAL PUMPS

DETAILED EQUIPMENT SPECIFICATION HIGH PURITY LABORATORY WATER SYSTEM

Materials of Construction Cast Iron Bronze Cast Iron Stainless Stainless Stainless Neoprene Ni-Resist A * A A

SECTION METERS AND GAGES FOR PLUMBING PIPING

AS Series Simplex and AD Series Duplex Lubricated Climate Control Air Compressors

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

1SV (e-sv) 50 Hz 2900 RPM

Series: G5-1¼, G6-1¼ RPM - 60Hz. CAPACITIES TO 80 GPM (5 LPS) HEADS TO 135 FEET (41 M)

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM

High Temperature Chemical Process Inline Pumps

2 30 HP RECIPROCATING AIR COMPRESSORS. R-Series

Series 4600F. HSC Fire Pumps & Packaged Systems

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

MOTOR SPEED PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1442 Page 1442.

GM25 Motor Dimensional Information

Transcription:

Bulletin S-215F Series CC Condensate Units Simplex or Duplex 1,000 thru 15,000 sq. ft. EDR 250 thru 7,500 lb./hr. Cast Iron Receivers: for years of dependable service; warranted for 20 years from date of shipment against failure due to corrosion. Centrifugal Pumps: provide generous running clearances. Standard 500 RPM for best hydraulic efficiencies, optional 1750. Float Switches: Double pole heavy duty, externally adjustable. Maximum Condensate Temperature: 200 F (9 C) 209 F (98 C) available at certain points OPTIONAL EQUIPMENT INCLUDES: Factory Mounted Control Panels Water Level Gauge Dial Thermometer Inlet Basket Strainers Suction Butterfly Valves (Available on pump with capacities to 115gpm [45 L /M]) Types of Alternation Discharge Pressure Gauges High Level Alarm Domestic Pump Equipment Selection Programs

SERIES CC CONDENSATE UNITS MOTOR HORSEPOWER RECEIVER SYSTEM CAPACITY PRESSURE 500 1750 SIZE MODEL CAPACITY SIZE CAPACITY GPM ( L /M) PSIG (kpa) RPM RPM IN. (mm) NUMBER GAL. (L) IN. (mm) 15* (10) 1/ 1/ 61.5CC 20* (18) 1/ 1/2 1,000 thru 6,000 62CC 6 (2) 25* (172) 1/2 /4 62.5CC Simplex 0* 1/2 6CC 6 (2) 1 /4 **4 /4 250 thru 1,500 (19) 64CC 14 (5) 50 (45) **4 lb./hr. 65CC Duplex 60 (414) 2 /4 **4 (11-680 kg/hr) 66CC 75 (518) /4 **4 67.5CC 90 (621) /4 **4 69CC 2 (87) 15* (10) 1/ 1/ 91.5CC 20* (18) 1/ 1/2 1,000 thru 9,000 92CC 9 (4) 25* (172) 1/2 /4 92.5CC Simplex 0* /4 9CC 9 (4) 1 /4 **4 /4 250 thru 2,250 (19) 94CC 14 (5) 50 (45) **4 lb./hr. 95CC Duplex 60 (414) 2 /4 **4 (11-1,021 kg/hr) 96CC 75 (518) /4 **4 97.5CC 90 (621) /4 **4 99CC 2 (87) 15* (10) 1/ 1/ 121.5CC 20* (18) 1/ 1/2 122CC 12,000 25* (172) 1/2 /4 122.5CC 12 (45) 0* /4 1 /4 **4 /4 (19) 12CC 124CC 14 (5),000 lb./hr. 50 (45) **4 125CC (1,61 kg/hr) 60 (414) 2 /4 **4 126CC 75 90 (518) (621) /4 5 /4 **4 **4 127.5CC 129CC 2 (87) 15* (10) 1/ 1/2 151.5CC 20* (18) 1/ /4 152CC 15,000 25* (172) 1/2 1 /4 152.5CC 15 (57) 0* /4 1 /4 **4 /4 (19) 15CC 154CC 14 (5),750 lb./hr. 50 (45) **4 155CC (1,701 kg/hr) 60 (414) 2 /4 **4 156CC 75 (518) /4 **4 157.5CC 90 (621) 5 /4 **4 159CC 2 (87) 15* (10) 1/ 1/2 221.5CC 20* (18) 1/2 /4 222CC 22,000 25* (172) /4 1 /4 222.5CC 0* /4 22CC 22 (8) **4 (8) 224CC 2 (87) 5,500 lb./hr. 50 (45) 2 /4 **4 225CC (2,495 kg/hr) 60 (414) /4 **4 226CC 75 (518) /4 **4 227.5CC 90 (621) 5 /4 **4 229CC 15 (10) 1/2 /4 01.5CC 20 (18) /4 /4 02CC 0,000 25 (172) /4 02.5CC 0 (114) 0 1 /4 **4 (8) 0CC 04CC 6 (16) (76) 7,500 lb./hr. 50 (45) 2 /4 **4 05CC (,2 kg/hr) 60 (414) /4 **4 06CC 75 (518) 5 /4 **4 07.5CC 90 (621) 5 /4 **4 09CC 15 (10) 1/2 /4 71.5CC 20 (18) /4 1 /4 72CC 7,000 25 (172) /4 72.5CC 7 (1) 0 2 /4 **4 (8) 7CC 74CC 6 (16) (76) 9,250 lb./hr. 50 (45) /4 **4 75CC (4,196 kg/hr) 60 (414) /4 **4 76CC 75 (518) 5 /4 **4 77.5CC 90 (621) 5 /4 **4 79CC 15 (10) /4 /4 451.5CC 20 (18) 1 /4 1 /4 452CC 45,000 25 (172) 1 /4 452.5CC 0 2 /4 45CC 45 (170) 2 /4 **4 (8) 454CC 6 (16) (76) 11,250 lb./hr. 50 (45) /4 **4 455CC (5,10 kg/hr) 60 (414) /4 **4 456CC 75 (518) 5 /4 **4 457.5CC 90 (621) 5 /4 **4 459CC = Lb./hr. Condensate 4 * Maximum Condensate Temperature: 209 F (98 C) 500 RPM ONLY. ** 500 RPM is standard. 1750 RPM is not available. 500 RPM units to 50 psi discharge pressure use B design receiver as standard. 500 RPM units 60 psi or more use A design receiver. 1750 RPM units use A design receiver. 2

SERIES CC CONDENSATE UNITS MOTOR HORSEPOWER RECEIVER SYSTEM CAPACITY PRESSURE 500 1750 SIZE MODEL CAPACITY SIZE CAPACITY GPM ( L /M) PSIG (kpa) RPM RPM IN. (mm) NUMBER GAL. (L) IN. (mm) 15 (10) 1 1 601.5CC 20 (18) 602CC 60,000 25 (172) 602.5CC 60 (227) 0 2 2 ** 60CC 604CC 52 (197) (76) 15,000 lb./hr. 50 (45) ** 605CC (6,804 kg/hr) 60 (414) 5 ** 606CC 75 (518) 5 ** 607.5CC 90 (621) 7 1 /2 ** 609CC 15 (10) 751.5CC 20 (18) 752CC 75,000 25 (172) 2 2 752.5CC 18,750 lb./hr. 75 (284) 0 50 (45) 5 ** ** 754CC 755CC 75 (284) 4 (102) (8,505 kg/hr) 60 (414) 5 ** 756CC 75 (518) 7 1 /2 ** 757.5CC 90 (621) 7 1 /2 ** 759CC 15 (10) 901.5CC 90,000 20 (18) 2 2 902CC 25 (172) 2 2 902.5CC 90 (41) 0 90CC 5 ** 24,250 lb./hr. 904CC (11,000 kg/hr) 50 (45) 5 ** 905CC 60 (414) 7 1 /2 ** 906CC 75 (284) 4 (102) 75 (518) 7 1 /2 ** 907.5CC 15 (10) 2 1121.5CC 112,000 20 (18) 2 2 1122CC 25 (172) 1122.5CC 112 (424) 0 112CC 5 ** 28,000 lb./hr. 1124CC (12,701 kg/hr) 50 (45) 5 ** 1125CC 60 (414) 7 1 /2 ** 1126CC 120 (454) 4 (102) 75 (518) 10 ** 1127.5CC 15 (10) 2 1501.5CC 150,000 20 (18) for 500 RPM 1502CC 25 (172) 5 5 units 1502.5CC 150 (568) 0 5 5 150CC 7 1 /2 7,500 lb./hr. ** (76) 1504CC 50 (45) 7 1 /2 (17,010 kg/hr) ** for 1750 RPM 1505CC 60 (414) 10 ** units 1506CC 75 (518) 10 ** 1507.5CC 120 (454) 4 (102) = Lb./hr. Condensate 4 **500 RPM is standard. 1750 RPM is not available. STANDARD UNIT FEATURES: Cast Iron Receiver, sizes 14 gallon (5L) and larger have provision for second pump. Receiver sized for 1 minute net storage. Cast Iron Receivers are warranted for 20 years from date of shipment against failure due to corrosion. Centrifugal Pump(s) with drip-proof motors. Pump capacity sized 2 times system return rate. Float switch(es). ORDERING INSTRUCTIONS: Specify basic Model No., RPM, single or duplex, phase, operating voltage, special features. TEFC and explosion proof motors available. The motor horsepower requirement is often greater using explosion proof as they have unity service factor. A horsepower increase is not necessary using TEFC motors. OPTIONAL FEATURES AVAILABLE AS SPECIFIED: Water level gauge w/shut-off valve* Dial Thermometer* Inlet Basket Strainer Discharge Pressure Gauges NEMA 4 or NEMA 7 Float Switches Mechanical Alternator provides sequencing of duplex pumps and standby of second pump on high level. (NEMA 4 or 7 mechanical alternators available on receiver sizes 6 gallons [16L] and larger) Control Panels, see page 4. (Control Panels cannot be mounted on 6 & 9 gallon [2 & 4L] receivers, use 14 gallon [5L] minimum) Suction Butterfly Valve " (76mm) (Available for pump capacities to 75 gpm [284 L /M]) Suction Butterfly Valve 1 /2" (89mm) (Available for pump capacities to 76 to 115 gpm [288 to 45 L /M]) TEFC or Explosion Proof Motors High Level Float Switch/Standby Float Switch (Consult factory for arrangement) Lifting Eyes (Available on Receiver sizes 2 gallon [87L] and larger) Tapping/openings not drilled on 9 or 14 gallon (4 or 5L) unless option is specified. *Not available on 6 gallon (2L) receivers.

6 & 9 GALLON RECEIVER WITH 609PF 2DCC25 6 1 /2 (165) MIN. DIAL THERMOMETER (OPTIONAL 9 [4] GAL ONLY) OPTIONAL BASKET STRAINER SHIPPED LOOSE GAUGE GLASS (OPTIONAL 9 [4] GAL ONLY) 609PF FLOAT SWITCH FOR CONTROL /4 (19) NPT 1 1 /2 (4) NPT 16 1 /2 (419) 1 1 /4 (2) NPT VENT 8 1 /4 (210) (5) 12 15 /16 (29) A B C NPT 2 1 /8 (54) 4 1 /4 (108) 1 1 /4 (2) 1 1 /4 (2) NPT DRAIN 22 /4 (578) BUTTERFLY SUCTION VALVE (OPTION NOT SHOWN, SEE NOTE #1) DIMENSIONS IN INCHES (mm) GAL. (L) A B C 6 8 9 /16 7 1 /16 6 11 /16 (2) (217) (179) (170) 9 10 7 /8 9 /8 9 (4) (28) (229) 1. For optional Butterfly Suction Valve, add 2" (51mm) to 22 /4" (578mm) dimension. 2. Optional Discharge Pressure Gauges (not shown) shipped loose. 6 & 9 GALLON RECEIVER WITH ALL OTHER PF S (EXCEPT 609PF) 2DCC26 6 1 /2 (165) MIN. DIAL THERMOMETER (OPTIONAL 9 [4] GAL ONLY) OPTIONAL BASKET STRAINER SHIPPED LOOSE GAUGE GLASS (OPTIONAL 9 [4] GAL ONLY) /4 (19) NPT WITH ORIFICE 2 /8 (594). TYPE PF FLOAT SWITCH FOR CONTROL 1 1 /2 (4) NPT 16 1 /2 (419) 1 1 /4 (2) NPT VENT 8 1 /4 (210) (2) 20 (508) A B C NPT 1 1 /4 (2) 1 1 /4 (2) NPT DRAIN 24 1 /2 (622) BUTTERFLY SUCTION VALVE (OPTION NOT SHOWN, SEE NOTE #1) 4 DIMENSIONS IN INCHES (mm) GAL. (L) A B C 6 8 9 /16 7 1 /16 6 11 /16 (2) (217) (179) (170) 9 10 7 /8 9 /8 9 (4) (28) (229) 1. For optional Butterfly Suction Valve, add 2" (51mm) to 22 /4" (578mm) dimension. 2. Optional Discharge Pressure Gauges (not shown) shipped loose.

14 GALLON A DESIGN RECEIVER (S ON DIFFERENT SIDES) WITH 609PF 2DCC11 5 / 8 (17) LAG FLOAT SWITCH /HIGH LEVEL ALARM FLOAT SWITCH 5" (127) (FLOAT SWITCH) 7" (178) (MECH. ALT.) 609 2 (584) 2 1 /4 (591) NPT 12 (05) 10 1 /2 9 7 /8 (267) (251) 14 GAL. ONLY (5 L) 1 1 /4 (2) NPT VENT LEAD FLOAT SWITCH /MECH. ALT (DUPLEX) /FLOAT SWITCH FOR SINGLE / 4 (19) NPT 1 1 /4 (2) NPT 9 1 / 2 (241) 1 1 / 2 (8) (5) 5 /4 (146) WATER GAUGE NO. 2 5 /8 (16) 1 /4 (44) 8 (20) (76) 17 SQ (42) 26 1 /2 (67) 1 1 / 8 (29) 2 /8 (60) / 4 (19) 1 / 4 (6) 5 (127) 14 1 /4 (62) 1 /2 (851) TYP (5) 1. Optional equipment furnished at extra cost when ordered. 2. Optional Discharge Pressure Gauge ASM and Inlet Basket Strainer shipped loose.. Optional Butterfly Valve requires the addition of 2" (51mm) to G (duplex) and H dimensions. 4. Pump discharge varies with pump specification. 14 GALLON A DESIGN RECEIVER (S ON DIFFERENT SIDES) WITH ALL OTHER PF S (EXCEPT 609PF). STANDARD FOR ALL 1750 RPM. STANDARD FOR 500 RPM UNITS 60PSI OR HIGHER PRESSURE 2DCC12 LAG FLOAT SWITCH /HIGH LEVEL ALARM FLOAT SWITCH 7" (178) (MECH. ALT.) 5" (127) (FLOAT SWITCH) 5 /8 (17) 2 (584) 2 1 / 4 (591) NPT 12 10 1 / 2 (05) 9 7 / 8 (267)(251) 14 GAL. ONLY (5 L) 1 1 /4 (2) NPT VENT LEAD FLOAT SWITCH /MECH. ALT (DUPLEX) /FLOAT SWITCH FOR SINGLE PRESSURE GAUGE ASM. 1 1 / 4 (2) NPT 9 1 /2 (241) 1 1 / 2 (8) (5) 5 / 4 (146) WATER GAUGE NO. 2 5 /8 (16) 1 /4 (44) 8 (20) (76) 17 SQ (42) 0 (762) 1 1 /8 (29) /4 (19) 5 (127) 14 1 /4 (62) 7 (8) TYP (5) 1. Optional equipment furnished at extra cost when ordered. 2. Optional Inlet Basket Strainer shipped loose.. Optional Butterfly Valve requires the addition of 2" (51mm) to G (duplex) and H dimensions. 4. Pump discharge varies with pump specification. 5

14 GALLON B DESIGN RECEIVER (S ON SAME SIDE) WITH 609PF 2DCC27 VENT (IF LAG FLOAT SW OR HLA USED) ALL DIMENSIONS IN INCHES (mm) DIAL THERMOMETER 6 (152) 6 1 /2 (165) MIN OPTIONAL BASKET STRAINER SHIPPED LOOSE 1. For optional Butterfly Suction Valve, add 2" (51mm) to 22 /4" (578mm) dimension. 2. Optional Discharge Pressure Gauges (not shown) shipped loose. GAGE GLASS THIS DUPLEX UNIT ONLY / 4 (19) NPT 609PF LEAD FLOAT SW DUPLEX/ MECH ALT DUPLEX FLOAT SW SIMPLEX 2 1 /4 (591) NPT 22 1 /2 (572) 1 1 /4 (2) NPT VENT (IF LAG FLOAT SW OR HLA NOT USED) 1 (286) 12 15 /18 (29) 11 / 4 (298) 10 1 /4 9 7 / 8 (260) (251) NPT 2 1 / 8 (54) 4 1 /4 (114) 11 5 /8 (295) 1 / 8 1 / 8 (5) (79) 1 1 /4 (2) NPT DRAIN 1 1 /2 (42) 22 /4 (578) BUTTERFLY SUCTION VALVE (OPTION NOT SHOWN, SEE NOTE 1) LAG FS DUPLEX/ HIGH LEVEL ALARM (HLA) 14 GALLON B DESIGN RECEIVER (S ON SAME SIDE) WITH ALL OTHER PF S (EXCEPT 609PF). STANDARD FOR 500 RPM UP TO 50 PSI PRESSURE 2DCC28 25 /8 (645) VENT (IF LAG FLOAT SW OR HLA USED) DIAL THERMOMETER GAGE GLASS 6 (152) 6 1 / 2 (165) MIN. OPTIONAL BASKET STRAINER SHIPPED LOOSE THIS DUPLEX UNIT ONLY ALL DIMENSIONS IN INCHES (mm) 1. For optional Butterfly Suction Valve, add 2" (51mm) to 24 1 /2" (622mm) dimension. 2. Optional Discharge Pressure Gauge(s) (not shown) shipped loose. /4 (19) NPT WITH ORIFICE TYPE PF 20 (508) 2 1 / 4 (591) 11 /4 (298) NPT 10 1 /4 9 7 /8 (260) (251) 22 1 / 2 (572) 1 1 / 4 (2) NPT VENT (IF LAG FLOAT SW OR HLA NOT USED) 11 1 / 2 (286) 1 7 / 8 NPT (5) 11 5 /8 (295) 29 /8 (746) (2) NPT 1 1 /2 (4) BUTTERFLY SUCTION VALVE (OPTION NOT SHOWN, SEE NOTE 1) LAG FS DUPLEX/ HIGH LEVEL ALARM (HLA) 6

2 GALLON 2DCC1 MECHANICAL ALTERNATOR (MA) LEAD FS DUPLEX/ MA DUPLEX/ FS SIMPLEX WITH HLA LIFTING EYE 1 /2 (89) NPT VENT FLOAT SWITCH(ES) NO. 2 LAG FS DUPLEX/ FS SIMPLEX LESS HIGH LEVEL ALARM (HLA)/HLA ALL NO. 1 BUTTERFLY VALVE (OPTION NOT SHOWN) ALL DIMENSIONS IN INCHES (mm) 1. Optional Inlet Basket Strainer shipped loose. 2. Optional Butterfly Valve(s) requires the addition of 2" (51mm) to overall dimension. Receiver Capacity: Gross 2 Gallons (87L) Net 16 Gallons (61L) 2 1 /4 (591) 1 1 /16 (2) 2 /4 (70) 10 (254) 1 (25) NPT DRAIN GAUGE GLASS PRESSURE GAUGE ASSEM /4 (19) 2 (51) NPT 10 (254) NPT 1 1 /4 (2) 20 1 /2 (521) 2 (584) 8 /8 (975). (4) SLOTS FOR Ø1/2 (Ø1) MTB. STUDS PROJECTING 1-1/2 (8) ABOVE FLOOR 1 /4 17 1 /2 (445) (44) 21 (5) 22 1 /4 SIMPLEX (565) SEE 7 /4 (956) NOTE #2 DUPLEX 6-120 GALLON 2DCC14 LIFTING EYE VENT 1 /2 (89) NO. 1 1 /2 (89) LEAD FS DUPLEX/ MA FOR 6, 52, 75 DUPLEX/ FS SIMPLEX WITH HLA FLOAT SWITCH(ES) MECHANICAL ALTERNATOR NO. 2 LAG FS DUPLEX/ MECH. ALT 120 DUPLEX FS SIMPLEX LESS HLA/ HIGH LEVEL ALARM (HLA) 6 & 52 DIMENSIONS IN INCHES (mm) REC. CAP VENT K L GROSS NET & O/F A B C D E F G H J M N P DRAIN 6 25 2 21 1 /4 24 /4 2 24 1 15 1 /16 26 5 /16 2 1 /2 /4 8 7 1 15 /16 12 1 /2 1 1 /4 1 (16L) (95L) (51) (76) (5) (629) (546) (610) (0) (2) (668) (64) (19) (965) (9) (49) (18) (2) (25) 52 2 24 1 /4 27 /4 25 1 /4 27 /4 14 16 1 /16 29 5 /16 2 7 /8 1 41 /4 1 15 /16 1 1 /2 1 1 /4 1 (197L) (125L) (51) (76) (616) (705) (641) (705) (56) (427) (745) (7) (25) (1041) (105) (49) (4) (2) (25) 75 48 2 1 /2 4 27 /4 1 /4 29 /4 1 1 /4 16 19 1 /162 1 /16 1 /2 1 44 1 /2 44 1 /2 2 /16 15 7 /2 1 1 /4 1 (284L) (182L) (64) (102) (705) (806) (756) (794) (6) (50) (8) (89) (25) (110) (110) (56) (87) (2) (25) 120 91 2 1 /2 4 6 1 /4 9 /4 0 /4 2 /4 20 24 41 /16 4 1 48 /8 55 /8 2 1 /2 19 7 /2 1 2 1 /2 (454L) (44L) (64) (102) (921) (1010) (781) (82) (508) (610) (1046) (102) (25) (1229) (17) (64) (488) (25) (64) H M (O/F) GAUGE GLASS 2 1 /4 (591) RD FS FOR HLA 75 & 120 2 1 /2 (64) NPT PRESS GAUGE ASSEM (OPT) E 1 /4 (44) DRAIN A B G SIMPLEX L DUP H BUTTERFLY VALVE (OPTION NOT SHOWN) P C D K J F (4) SLOTS FOR Ø1/2 (Ø1) MTG. STUDS PROJECTING 1-1/2 (8) (6) & 1-/4 (44 ) (52-10) (121-048) ABOVE FLOOR. 1. Optional Inlet Basket Strainer shipped loose. 2. Optional Butterfly Valve(s) requires addition to the overall dimension as follows: 2" for 0-75 GPM (51mm for 0-284 L /M) 5" for 76-115 GPM (122mm for 288-215 L /M). All openings are NPT. 7

250 GALLON 2DCC15 12 (05) 6 (152) ALL DIMENSIONS IN INCHES (mm) 16 (6) (76) NPT VENT 1. Optional Basket Strainer shipped loose. 2. Optional Butterfly Valve(s) requires addition to the overall dimension as follows: 2" for 0-75 GPM (51mm for 0-284 L /M) 5" for 76-115 GPM (127mm for 288-45 L /M) NO. 1 NO. 2 LAG FLT SW DUPLEX/ HIGH LEVEL ALARM 2 1 /4 (591) LIFTING EYE GAUGE GLASS FLT SW SIMPLEX/ LEAD FLT SW DUPLEX MECH ALT DUPLEX G 4 (102) NPT BASKET STRAINER SEE NOTE 2 14 (56) MIN 2 1 /2 (64) NPT 2 (81) PRESSURE GAUGE ASSEMBLY (8) 7 /8 (22) 25 15 /16 (659) DOMESTIC TYPE PF 24 (610) (4) SLOTS FOR Ø1/2 (Ø1) MTG. STUDS PROJECTING 2" (51) ABOVE FLOOR 17 (42) 24 (610) 9 1 /2 (241) 56 (1422) 60 (1524) 1" (25) NPT DRAIN BUTTERFLY VALVE (OPTION NOT SHOWN) SEE NOTE 2 (8) 29 (77) 2 (81) 47 5 SEE NOTE 2 /8 (1210) OPTIONAL ELECTRIC CONTROLS Description of Optional Panel Components Magnetic Starters must be used on all phase motors and single phase motors over 2 HP. Disconnect Switches and Circuit Breakers. Either fuses or a circuit breaker is required ahead of the starters to protect against short circuits. A disconnect switch or circuit breaker also provides a means of shutting off power for service. Control Power Switching Relay should be supplied in Duplex or Triplex units when individual pump disconnect switches are specified. This relay is recommended in order to maintain control power to the water makeup system in the event pump #1 disconnect switch is turned off or pump #1 fails. In this event the control power will be automatically supplied by pump #2. Selector Switches Auto-Off-Hand selector switches provide a means of shutting off pumps and a means of testing in the Hands position. Off-Hand-Lead-Lag selector switches may be furnished on duplex units with 2 float switches to provide manual alteration. Electric Alternator may be furnished on duplex units to provide automatic sequencing of lead pump. Use only when magnetic starters are provided and only with 2 float switches. Transformer is required by the National Electrical Code to reduce control voltage when power supply exceeds 250 volts. A transformer is recommended when voltage exceeds 10 volts. Refer to local codes for requirements. Pilot Lights Pump running pilot lights are available to indicate pump operation. Audible Alarm An alarm to indicate low or high water level may be furnished. A separate tank mounted level switch should be provided with an alarm. Specified Panel Components to be furnished with unit at extra cost. Standard panels are supplied with NEMA 2 enclosures and are U.L. listed unless otherwise specified. Domestic Pump COPYRIGHT 1984, 2001 BY ITT INDUSTRIES, INC. PRINTED IN U.S.A. 11-01 Domestic Pump 8200 N. Austin Avenue Morton Grove, IL 6005 Phone: (847) 966-700 Facsimile: (847) 966-9052 http://fhs.ittind.com