panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Similar documents
SG-B1 SERIES / SG-A1 SERIES

Safety device new products line up. Introducing a safety door switch with solenoid interlock that is among the world s thinnest*

HS5E Miniature Interlock Switches with Solenoid

HS6B Series Subminiature Interlock Switch

Door Interlock Switches

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

HS1C Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid

Door Interlock Switches

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

HS1E Series Full Size Interlock Switch with Locking Solenoid

HS1E Series Full Size Solenoid Locking Switches

HS5D Miniature Interlock Switches

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

HS5E Miniature Interlock Switches with Solenoid

HS6B HS6E. Angled connection. cable. Compact with three poles of contacts. (HS6B) Small interlock switch with five poles and solenoid.

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

Door Interlock Switches

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

Standard Interlock Safety Switches

HS5D Miniature Interlock Switches

HS5E Series Miniature Solenoid Locking Switches

HS5E Miniature Interlock Switches with Solenoid

HS1E-K Interlock Switches with Solenoid (3-circuit)

Standard Interlock Safety Switches

Interlock Switches. Safety. Selection Guide HS6B Subminiature HS5D Miniature HS2B Full Size...

HS6E - L 4 4 B 01 - G

Door Interlock Switches

Head Removal Detection Function for Safer Performance

HS1L Interlock Switches with Solenoid

HS6E Subminiture Interlock Switches with Solenoid

HS1C-P Interlock Plug Unit with Door Lock

HS6E Subminiature Interlock Switches with Solenoid. Double Installation. Part Number. Cable Length (+) ( ) A2 A1

HS1L Interlock Switches with Solenoid

Solenoid Locking Safety Switches

Section. Safety Products Selection Guide...B-2

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches

Solenoid Locking Safety Switches

HS1E Interlock Swithes with Solenoid

Door Interlock Switches

HS6B Subminiature Interlock Switches

Interlock Switches Interlock Plugs

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

ct O en n Tr ve Solenoid Indicator (1) TÜV rating AC V, 3A 3 Mounting Examples

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Safety-door Switch. Ordering Information

D4GS-N CSM_D4GS-N_DS_E_7_2

HS7A-DMC Non-contact Interlock Switches

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2

2NC (slow-action) Direct. Model. opening

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Safety Limit Switch

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4BS CSM_D4BS_DS_E_8_4

XA Series Emergency Stop Switches (w/removable Contact Block)

Enabling Switches Grip Style Enabling Switches

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Hinged Safety Door Switch

HL (AZH) LIMIT SWITCHES

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Safety Control HR1S-AC. Safety Relay HR1S-AC

2NC (slow-action) Direct. Model. opening

2 Specifications and Ratings. Applicable Standards. Operating Condition. Thermal Current Ith 10A Contact Ratings. Operating Speed

XW Series E-Stops. Safety. ø22mm XW E-Stops Phone: Fax: Web: -

HL (AZH) Limit Switches

XW Series Emergency Stop Switches

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

D4GL. Environment-friendly Switch with Direct Opening Contacts. Guard Lock Safety-door Switch. Model Number Structure

F3S-TGR-KM15/-KM16/-KH16

Emergency Stop Switches Selection Guide

F3S-TGR-KHL1/-KHL3/-KHL3R

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions. Ordering Information

LR-LX-LK-LW Safety Switches with separate actuator

XW Series E-Stops. Safety. Selection Guide ø22mm XW E-Stops

Small Limit Switch D4V

AF40... AF96 3-pole contactors Technical data

Enabling Switches. Safety. Selection Guide

Manual Reset Limit Switch

PRODUCT SPECIFICATION. Stack Lights. Series.

Safety switches with separate actuator

Limit Switches with Positive Opening Mechanism

Power Contactor with Mirror Contacts

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

Overview of types. Technical data. Safety notes

Machine & Process Safeguarding Solution Selection Guide

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Switches & Pilot Devices

D4NH CSM_D4NH_DS_E_7_1

Rectangular-shaped Inductive Proximity Sensor.

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Safety rope switches with reset for emergency stop

Transcription:

655 Door with Key SERIES Related Information General terms and conditions... F-7 General precautions... P.50 PHOTO PHOTO Conforming to Machine & EMC Directives Recognition Certified MEASURE ITY panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key! No forgotten keys, No locked-in workers, No inadvertent machinery operation! The safety door switch with key series locks and unlocks doors with keys. When an operator takes a key into a hazardous area, the safety door switch will not lock, and the equipment will stop, ensuring operator safety by preventing personnel from being closed inside the hazardous area and preventing equipment from starting to operate. worker SG-B/SG-A SG-C SG-D SG-E SD3-A door switch with key series 2 Hazards of the system and robot are isolated by the safety guard. The worker uses the key to unlock the door and disables the system from starting unexpectedly, then removes the key and brings it into the hazardous area. The system remains off until the worker walks out the door and locks the door with the key. This enables the worker carrying the key to work safely in the hazardous area. Door unlocked 2 Key brought into the hazardous area

Door with Key SERIES 656 Additionally, the key selector switch SG-D series can be used to switch equipment modes and unlock door locks with a single key. Partial mode change Key selector switch SG-D series door switch with key series Single key! Energy-saving design, no power supply required 2 Hazards of the system and robot are isolated by the safety guard. When a worker needs to work inside the hazardous area for maintenance, the worker unlocks the safety guard using a key, disables the system from starting (), removes the key and brings it into the hazardous area, and then changes the operation mode of each system to maintenance mode (2). While the worker is carrying out maintenance work in the hazardous area, the safety guard cannot be locked and the system cannot be turned on. This enables the worker to work safely in the hazardous area. Since doors are locked and unlocked with a key, there is no need to supply power to the safety door switch. Door unlocked (safety output off) 2 Equipment mode change PHOTO PHOTO MEASURE ITY Head removal detection function Head removal detection function is employed in the. With this innovative function, the monitor circuit (4-42) turns off when the head is removed from the switch, such as when removing the head to change the head direction. With the head installed on the switch, monitor circuits 4-42 and 5-52 operate in synchronization while the key locks / unlocks the actuator. When the head is removed, 4-42 turns off and 5-52 turns on. This disagreement is detected by the head removal detection function. (4-42) with head removal detection function unlocked locked Head removed unlocked locked When the head removed LOCK UNLOCK (NC) Pink 4 42 Pink / OFF ON OFF (NC) Brown 5 52 Brown / OFF ON ON Note: Head removal detection function is not direct opening. Disagreement SG-B/SG-A SG-C SG-D SG-E SD3-A

657 Door with Key SERIES High-security pin tumbler key types are used All models come with cables pre-installed. Double-insulated design eliminates the need for grounding wires. Choose an actuator based on the door shape and application. Available with rear unlocking button Models with a rear unlocking button allow the door to be unlocked from the inside in the event a worker is left in the hazardous area. Equipment combination examples related to machine safety Straight actuator SG-K2 / SG-K2A Pushbutton type emergency stop switch SG-E series Enable grip switch SG-C series ITY Right-angle actuator SG-K22 / SG-K22A Slide actuator SG-K2S relay unit SF-AC SG-B/SG-A SG-C SG-D SG-E SD3-A ORDER GUIDE door switch with key Rear unlocking button Without With Horizontal / vertical angle adjustable actuators SG-K24 s are not included with door switches and must be purchased separately. Blue Blue Orange Blue Orange Contact arrangement (Note) Orange 23 2 22 Key selector switch SG-D series 4 42 5 52 Note: The contact configuration shows the status when the actuator is inserted and the switch is locked. Key LOCK and UNLOCK positions are as shown on the right. 2 24 2 Blue / Orange / Blue / Orange / 2 Blue / 2 22 Orange / Pink Pink Brown Pink Brown LOCK 4 42 UNLOCK Pink / Brown 53 54 Brown / 4 42 5 52 Pink / Brown / Pink / Brown / Cable length 5 m 6.404 ft 5 m 6.404 ft 5 m 6.404 ft Key removal position A (removable in all positions) B (removable in UNLOCK C (removable in LOCK A (removable in all positions) B (removable in UNLOCK C (removable in LOCK A (removable in all positions) B (removable in UNLOCK C (removable in LOCK es incorporate two detents so that they stop in each position. door switch with key series LOCK Model No. -K2AC-5 -K2BC-5 -K2CC-5 -K2AD-5 -K2BD-5 -K2CD-5 -K2AD-L5 -K2BD-L5 -K2CD-L5 UNLOCK

Door with Key SERIES 658 ORDER GUIDE s s are not included with door switches and must be purchased separately. Straight actuator Type Description Model No. Straight actuator with rubber bushings Slide actuator Right-angle actuator Right-angle actuator with rubber bushings Horizontal / vertical angle adjustable actuators The actuator tensile strength when using this product is,400 N. The actuator tensile strength when using this product is 500 N. SG-K2 SG-K2A SG-K2S SG-K22 SG-K22A SG-K24 Note: When using a safety door switch with key on a hinged door, see page 27 for more information about the minimum door radius with which the switch can be used. SG-K2 SG-K2A SG-K2S SG-K22 SG-K22A SG-K24 ITY Type Model No. Padlock hasp SG-PH2 Padlock hasp (Note ) SG-PH2 Mounting plate (for mounting on an aluminum frame) MS-SG-2 Rear unlocking button kit for a frame (Note 2) Notes: ) The shackle diameter for compliant padlocks ranges from ø5.5 to ø7.5 mm ø0.27 to ø0.295 in. 2) For more information about selecting a back manual unlock button kit for a frame, see the following table: Model No. MS-SG-22 MS-SG-23 Shackle diameter: ø5.5 to ø7.5 mm ø0.27 to ø0.295 in Mounting part* thickness (X) (mm in) Rear unlocking button type When installing an -K2 D-L5 with a rear unlocking button directly MS-SG-22 33 < X 43.299 < X.693 MS-SG-23 23 < X 33 0.906 < X.299 * The mounting part is a frame or a panel that the product is mounted on. Mounting plate (for mounting on an aluminum frame) MS-SG-2 Rear unlocking button kit for a frame MS-SG-22 MS-SG-23 SG-B/SG-A SG-C SG-D SG-E SD3-A

659 Door with Key SERIES ITY SG-B/SG-A SG-C SG-D SG-E SD3-A switch status Door status Circuit diagram (Example: -K2 D-L5) 2 22 Operation characteristics (reference) -K2 C-5 (-2) (23-24) (4-42) (53-54) 2 2 2 22 0 ( mounting reference Approx. 3.3 0.30 (Lock) Approx. 5.3 0.209 Approx. 6.9 0.272 ( completely inserted) 4 42 5 52 4 42 5 52 : Contact ON (closed) : Contact OFF (opened) Approx. 26.4.039 (Travel: mm in) ( pulled out) -K2 D-5 -K2 D-L5 (-2) (2-22) (4-42) (5-52) The characteristics show the contact status when the actuator enters an entry slot of an safety switch. The characteristics shown in the chart above are of the SG-K2 actuator. For the others actuator, add.3 mm 0.05 in. : Closed : Open Status Status 2 Status 3 Rear manual unlock Door closed Machine ready to operate Door closed Machine cannot be operated Door open Machine cannot be operated 0 ( mounting reference Approx. 3.3 0.30 (Lock) Approx. 5.3 0.209 Approx. 6.9 0.272 ( completely inserted) Approx. 26.4.039 (Travel: mm in) ( pulled out) Door closed Machine cannot be operated Door Closed (locked) Closed (unlocked) Open Closed (unlocked) -K2 C-5 (door closed) -2 2 LOCK UNLOCK (door open) 23-24 4 42 23 24 (locked) 53 54 4-42 (unlocked) 53-54 -K2 D-5 (door closed) -2 (door closed) 2-22 Model No. and contact configuration CONTACT CONFIGURATION / OPERATING PATTERNS -K2 D-L5 (locked) 4-42 (locked) 5-52 (door closed) -2 (door closed) 2-22 (locked) 4-42 (locked) 5-52 Notes: ) When the operator is confined in a hazardous area, the actuator can be unlocked manually by pressing the rear unlocking button, which should be accessed easily by the operator. 2) The above contact configuration shows the status when the actuator is inserted and the switch is locked. 3) : Sends monitoring signals of protective door open / closed status or protective door lock / unlock status. When connecting the series to a safety circuit, connect the door monitor circuits (-2) (4-42, 5-52) in series. (GS-ET-9) and the lock monitor circuits

Door with Key SERIES 660 SPECIFICATIONS PRECAUTIONS FOR PROPER Designation door switch with key Item Series series Applicable standards EN 088, IEC 60947-5-, EN 60947-5-, GS-ET-9, UL 508, CSA C22.2 No.4 Standards for use IEC 60204-, EN 60204- Applicable directives Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) Ambient -25 to +70 C -3 to +58 F (No dew condensation or icing allowed) temperature Storage: -40 to +80 C -40 to +76 F Ambient humidity 45 to 85 % RH Pollution degree 3 (Inside 2) Altitude 2,000 m 6,56.68 ft max. Impulse withstand voltage (Uimp) 2.5 kv Rated insulation voltage (Ui) 250 V (Note ) 2.5 A Thermal current Ambient temperature: (Ith) -25 to +60 C -3 to +40 F: 2.5 A max. +60 to +65 C +40 to +49 F:.5 A max. +65 to +70 C +49 to +58 F:.0 A max. Operating condition Rated operational voltage (Ue) / Rated operational current (Ie) Operating frequency operating speed B 0d Mechanical durability Electrical durability Ie Ue 30 V 25 V 250 V Resistive load (AC-2) - 2.5 A.5 A Inductive load (AC-5) -.5 A 0.75 A Resistive load (DC-2) 2.5 A. A 0.55 A Inductive load (DC-3) 2.3 A 0.55 A 0.27 A AC DC 900 operations/hour 0.05 to.0 m/sec. 2,000,000 (ISO 3849- Annex C Table C.),000,000 operations min. (GS-ET-9) Rear unlocking button: 3,000 operations min. (Type - -L5) 00,000 operations min. (AC-2, 250 V A),000,000 operations min. (AC/DC 24 V 00 ma) (900 operations/hour) Electric shock protection class Class II (IEC 640) (Note 2), (double-insulated) Interlock force,400 N min. (GS-ET-9) (Note 3) (500 N min. : SG-K24 actuator) Direct opening travel mm 0.433 in min. (actuator: SG-K2) 2 mm 0.472 in min. (for other actuators) Direct opening force 80 N min. Contact resistance 700 mω max. (initial value, 5 m 6.404 ft cable) Protection IP65 (IEC 60529) Shock resistance Malfunction: 00 m/s 2, Destruction:,000 m/s 2 Vibration resistance Malfunction: 0 to 55 Hz, half amplitude 0.35 mm 0.04 in Destruction: 30 Hz, half amplitude.5 mm 0.059 in Conditional short-circuit current 50 A (250 V) Short-circuit protective device Use 250 V / 0 A fast acting type fuse Material Enclosure: PA66 Cable UL style 2464, No.22 AWG 2-core Operating specifications 2 positions Mechanical durability 00,000 operations min. Key operating durability 0,000 operations min. Key tensile strength.0 N m min. Direct opening force 0.6 N m min. Direct opening degree 60 min. Weight - -5: Approx. 680 g, - -L5: Approx. 700 g Key Notes: ) Ratings approved by UL, c-ul: 25 V 2) Basic insulation of 2.5 kv impulse withstand voltage is ensured between different contact circuits. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. 3) The actuator locking strength is rated at,400 N of static load. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A safety switch) or a sensor to detect door opening and stop the machine. This catalog is a guide to select a suitable product. Be sure to read the instruction manual attached to the product prior to its use. In order to avoid electric shock or fire, turn the power off before installation, removal, wire connection, maintenance, or inspection of the safety switch. If relays are used in the circuit between the safety switch and the load, consider the danger and use safety relays, since welding or sticking contacts of standard relays may invalidate the functions of the safety switch. Do not place a in the circuit between the safety switch and the load. and security can be endangered in the event of a malfunction of the. Do not disassemble or modify the safety switch, otherwise a breakdown or an accident may occur. Do not install the actuator in a location where the human body may come in contact. Otherwise injury may occur. Regardless of door types, do not use the safety switch as a door stop. Install a mechanical door stop at the end of the door to protect the safety switch against excessive force. Do not apply excessive shock to the safety switch when opening or closing the door. A shock to the safety switch exceeding,000 m/s 2 may cause damage to the safety switch. If the operating atmosphere is contaminated, use a protective cover to prevent the entry of foreign objects into the safety switch through the actuator entry slots. Entry of a considerable amount of foreign objects into the safety switch may affect the mechanism of the safety switch and cause a malfunction. Cover the unused actuator entry slot using the slot plug supplied with the safety switch. Do not store the safety switches in a dusty, humid, or organic-gas atmosphere, or in an area subjected to direct sunlight. Use proprietary actuators only. When other actuators are used, the safety switch may be damaged. Do not cut, machine, or otherwise modify actuators. Doing so may cause equipment failure. Do not open the lid of the safety switch. Loosening the screws may damage the safety switch. The locking strength is rated at,400 N. Do not apply a load higher than the rated value. When a higher load is expected, provide an additional system consisting of another safety switch without lock or a sensor to detect door opening and stop the machine. Regardless of door types, do not use the safety switch as a door lock. Install a separate lock using a latch or other measures. Although the SG-K2A / SG-K22A actuators alleviate the shock when the actuator enters the slot on the safety switch, make sure that excessive shock is not applied. If the rubber bushings become deformed or cracked, replace with new ones. ITY SG-B/SG-A SG-C SG-D SG-E SD3-A

66 Door with Key SERIES ITY SG-B/SG-A SG-C SG-D SG-E SD3-A PRECAUTIONS FOR PROPER Do not mount the safety switch facing down as shown in the figure below. Otherwise, the key may fall off due to shock. Cables Do not fasten or loosen the gland at the bottom of the safety switch. When bending the cable during wiring, make sure that the cable radius is kept at 30 mm.8 in minimum. When wiring, make sure that water or oil does not enter the cable. Do not open the lid of the safety switch. Otherwise the safety switch will be damaged. Gland (Unit: mm in) Lid 30 mm.8 in of hinged door When using the safety switch on hinged doors, refer to the minimum radius of doors shown below. When using on doors with small minimum radius, use the angle adjustable actuator (SG-K24). Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure of the correct operation before installation. When using the right-angle actuator (SG-K22) <When the door hinge is on the extension line of the actuator mounting surface> 230 mm 9.055 in 260 mm 0.236 in (4.5.634) (40.3.587) switch (23 9.094) (Unit: mm in) <When the door hinge is on the extension line of the safety switch surface> 70 mm 6.693 in (36.2.425) 90 mm 7.480 in (35.374) switch (6 6.339) (Unit: mm in) When using the right-angle actuator (with rubber bushings) (SG-K22A) <When the door hinge is on the extension line of the actuator mounting surface> Centers 2 mm: 230 mm 0.472 in: 9.055 in Centers 20 mm: 30 mm 0.787 in: 2.205 in (48.2.898) 260 mm 0.236 in (47.850) switch (23 9.094) (Unit: mm in) <When the door hinge is on the extension line of the safety switch surface> Centers 2 mm: 20 mm 0.472 in: 4.724 in Centers 20 mm: 70 mm 0.787 in: 6.693 in (36.2.425) 40 mm 5.52 in (35.374) switch ( 4.370) (Unit: mm in) (48.890) angle adjustment (vertical / horizontal) Using the angle adjustment screw (M3 hexagon-socket-head screw), the actuator angle can be adjusted. Adjustable angle: 0 to 20 The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the actuator entry slot of the safety switch. After adjusting the actuator angle, apply Loctite to the adjustment screw so that the screw will not move. When using the angle adjustable actuator (SG-K24) When the door hinge is on the extension line of the actuator mounting surface: 70 mm 2.756 in When the door hinge is on the extension line of the safety switch surface: 50 mm.969 in <When the door hinge is on the extension line of the actuator mounting surface> (Horizontal adjustment) 70 mm 2.756 in (55.5 2.85) (Vertical adjustment) 70 mm 2.756 in Door hinge switch (55.5 2.85) <When the door hinge is on the extension line of the safety switch surface> (Horizontal adjustment) (Vertical adjustment) 50 mm.969 in Door hinge (36.2.425) 50 mm.969 in Door hinge switch (36.2.425) Mounting Mount the safety switch on a fixed piece of machinery or guard and the actuator on a hinged door. Avoid mounting both the safety switch and actuator on a hinged door. Doing so may cause equipment failure. For more information about how to mount the devices, see the following diagram: (Application on sliding doors) Door SG-K2 switch series Hook Door stop SG-K22 (58 2.283) (38.496) Application on hinged doors SG-K2S Door Recommended tightening torque for mounting screws Recommended screw tightening torque Screw tightening torque For mounting the safety switch (M4 screw) (Note ).8 to 2.2 N m For mounting the actuator (SG-K2 : Two M4 screws) (Note ) (SG-K2A / SG-K22A : Two M4 screws) (Note, 2) (SG-K2S : M5 screw) (Note ) (SG-K22 :Two M4 phillips screws) (SG-K24 : Two M4 screws) (Note ) For mounting the head (M3) For mounting the manual rear unlocking button (M3 screw with washers) Notes: ) The above recommended tightening torques of the mounting screws are the values confirmed with hexagon-socket-head bolts. When other screws are used and tightened to a smaller torque, make sure that the screws do not come loose after mounting. 2) In the case of SG-K2A or SG-K22A, using two M4 screws and two attached washers, fasten the actuator securely on the door. Refer to p.50 for general precautions..8 to 2.2 N m.0 to.5 N m 4.5 to 5.5 N m 0.8 to.2 N m.0 to.5 N m 0.9 to. N m 0.5 to 0.7 N m M4 screw Washer Rubber bushing Hinged door M4 tapped hole

Door with Key SERIES 662 DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. -K2-5 Door switch When using vertical mounting / straight actuator (SG-K2) 30.8 Slot plug (Note) 28.02 76.7 3.020 53.7 2.4 RP RP 26.4.039 42.2.66 73.2 2.882 4.64 26.4.039 6.2 0.244 5.2 0.205 5.2 0.205 6.2 0.244 ± 0.433 ± * 5 0.97 36.2.425 06 4.73 45.7 5.736 * center position ø25 ø0.984 R2.2 R0.087 When using vertical mounting / straight actuator (SG-K22) 35.378 (6.3 0.248) switch layout 20 0.787 33.299 40.575 20 to 22 0.787 to 0.866 06 4.73 4-holes for M4 ø4.3 ø0.69 or M4 tapped hole 76.7 3.02 53.7 2.4 5 0.97 28.02 73.2 2.882 36.2.425 06 4.73 45.7 5.736 6 ± 0.236 ± * R2.2 R0.087 35.378 (6.3 0.248) 20 0.787 33.299 40.575 30.8 29.6.65 cover Slot plug (Note) 38.496.8 0.07 6 0.630 76.7 3.020 53.7 2.4 RP RP 27.7.09 4.5.634 73.2 2.882 40.3.587 27.7.09 2.6 ± 0.496 ± * 5 0.97 36.2.425 06 4.73 45.7 5.736 ø25 ø0.984 R2.2 R0.087 mounting reference position As shown in the figure on the right, the mounting reference position of the actuator when inserted in the safety switch is: The actuator stop on the actuator lightly touches the safety switch. * The actuator stop is used to adjust the actuator position. Remove the actuator stop after the actuator position is mounted. (6.3 0.248) 35.378 switch SG-K2 29.6.65 20 cover switch layout 20 0.787 33.299 40.575 06 4.73 4-holes for M4 ø4.3 ø0.69 or M4 tapped hole 76.7 3.02 53.7 2.4 5 0.97 36.2.425 73.2 2.882 7.6 ± 0.299 ± * Door stop Door stop 06 4.73 45.7 5.736 Operation key * center position Notes: ) Plug the unused actuator entry slot using the plug supplied with the switch. 2) When mounting the safety switch, be sure to conform to the dimensions and secure in place with four screws. -K -L5 When using horizontal mounting / straight actuator (SG-K2) 20 to 22 0.787 to 0.866 R2.2 R0.087 (6.3 0.248) 20 0.787 switch 35.378 33.299 40.575 Door switch (rear unlocking button type) Mounting part * thickness (X): to 6 mm to 0.236 in 6 < X < 23 mm 0.236 < X < 0.906 in : Not mountable 23 X 53 mm 0.906 X 2.087 in : Use a rear unlocking button kit. (refer to page, 30) * The mounting part is a frame or a panel that the product is mounted on. With the dimension, the rear unlocking button rod does not touch the hole even when the safety switch moves sideways. Note: Plug the unused actuator entry slot using the plug supplied with the switch. cover SG-K22 ITY SG-B/SG-A SG-C SG-D SG-E SD3-A

663 Door with Key SERIES DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. ITY SG-K2 Straight actuator (SG-K2) 6.2 0.244 5.2 0.205 28.02 4-R 2.2 R0.087 0 0.394 30.8 () 2 0.472 32.4.276 (6 0.236) 0.8 0.03 6.4 0.252 5 0.59 26.024 (Note ) 2 0.079 7.3 0.287 43.8.724 5.3 0.602 0.8 0.03 2-ø4.3 ø0.69 0.8 0.03 When mounted (5 0.97) 26.5.043 2.5 3 0.52 0.098 Washer 2-ø0 ø0.394 2-ø9 ø0.354 Rubber bushing 30.5.20 material: Stainless steel (SUS) Thickness: 2.5 0.098 6 0.630 5 0.59 2.5 0.098 6 0.236 8-R2.6 R0.02 5 0.59 (Note) 2 0.079 56 2.205 4 0.55 5 37.5.476 0.97 9 0.748 8 (40.575) 30.7.209 0.709 3 0.8 75 2.953 layout (Straight / Right-angle actuator) 2-M4 thread Straight actuator with rubber bushings (SG-K2A) Slide actuator (SG-K2S) * Mounting pitch is set to 2 mm 0.472 in in factory. When setting the mounting pitch to 20 mm 0.787 in, widen the pitch of rubber cushions to 20 mm 0.787 in. * The actuator has movement flexibility to the directions shown in B. B layout Straight actuator with rubber bushings, Right-angle actuator with rubber bushings 2-M4 thread 2 0.472 ( ) * Mounting pitch can be widened to 20 mm 0.787 in by moving the rubber bushings. 2-ø5.2 ø0.205 35.378 34.339 48.5.909 Body material: Stainless steel (SUS) layout 6-M5 thread 5 2.008 32.5.280 Right-angle actuator (SG-K22) 30.8 28.02 4.5 0.77 (Note) 34.339 33.299 2 0.079 7.2 0.283 7.2 0.283 0.8 0.03 5 0.59 2 0.079 cover 2-ø4.4 ø0.73.6 0.063 Right-angle actuator with rubber bushings (SG-K22A) When mounted (39.7.563) When mounted 0.8 0.03 (.2 0.44) 5.8 0.622 8.5 0.335 30.8 2-ø9 ø0.354 2-ø0 ø0.394 2 0.079 5 0.59 A () 2 0.472 Rubber bushing Washer * When the mounting pitch is 2 mm 0.472 in (factory setting), the When mounted 0.8 0.03 actuator has movement flexibility to (5 0.97) the directions shown in A and B. * When the mounting pitch is 20 mm 0.787 in, the actuator has B movement flexibility to the directions 2-ø4.3 ø0.69 (Note) shown in B. Side the rubber cushions together with the screws. SG-B/SG-A SG-C SG-D SG-E SD3-A 49.929 Horizontal / Vertical angle adjustable actuators (SG-K24) Horizontal adjustment 5 0.59 3 0.8 Orienting insert 7 0.276 (Vertical adjustment) Orienting insert Angle adjustable screw (M3 hexagon-socket-head screw) (Note) 8.5 0.728 29.42 (Note) 0.8 0.03 20 23 0.906 26.024 38.496 (Hole for M4) 3.6 0.42 R2. R0.083 Angle adjustable screw (M3 hexagon-socket-head screw) 2 0.079 layout horizontal / vertical angle adjustable actuators 2-M4 thread Changes in the orientation of adjustment for angle adjustable (vertical / horizontal) actuators The orientation of adjustment of angle adjustable (vertical / horizontal) actuators is determined by the position in which the orienting insert (white plastic) is installed on the back of the actuator. Install the insert according to the desired orientation of adjustment. Exercise care not to lose the orienting insert. The actuator will not operate properly without the orienting insert. 38.496 SG-PH2 28.02 8 0.35 2-R4 R0.57 Padlock hasp (Optional) 2-ø8 ø0.35 20 Note: The actuator stop is used to adjust the actuator position. Remove the actuator stop after the actuator position is mounted. 6.5 0.650 60 2.362

Door with Key SERIES 664 DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. MS-SG2 Mounting plate (Optional) 2-2.8 0.504 2-6.6 0.260 4-M4 thread 40.575 6 0.236 0 0.394 4-R3.3 R0.30 42.2.66 50.7.996 Mounting plate hole layout When installing the -K2 -L5 (rear unlocking button type), provide a rear unlocking button a hole on the MS-SG2. (40.575) (3.4 0.528) 2 0.827 64. 2.524 switch mounting hole layout 3.4 0.528 ø8 ø0.709 hole for rear unlocking button (Note) 70 6.693 2 0.827 06 4.73 87 7.362 ø8 ø0.709 hole for rear unlocking button (Note) (87 7.362) 06 4.73 door switch with key series Connection link material: Stainless steel (SUS) Screw: Steel 22 0.866 4-C3 C0.8 4-R6.4 R0.252 Material: Anodized aluminum A6063 Weight: Approx. 80 g 4-M4 thread 20 to 22 0.787 to 0.866 Note : With the dimension, the rear unlocking button rod does not touch the hole even when the safety switch moves sideways. MS-SG-22 / MS-SG-23 ø0.4 ø0.409 Button (PA66) Hinge + plate [Stainless steel (SUS)] ø40 ø.575 Button pressed 2.3 0.839 (unlocked) 27.3.075 Button released 73 2.874 3.5.240 40.575 6 0.630 30.8 Pin [Stainless steel (SUS)] Total thickness of mounting frame, panel, and mounting plate: 23 to 43 mm 0.906 to.693 in 25.5.004 33.299 60.5 2.382 4-M4 thread Rear unlocking button kit for a frame (Optional) Rear unlocking button mounting dimensions ø8 ø0.709 hole for rear unlocking button (Note) 2 or 4-M4 thread 6 to 30 0.63 to.8 Example : When mounted on a 30 mm.8 in frame using the mounting plate above MS-SG-2, select MS-SG-22 since the mounting part thickness (X) is 40 (X = 0 + 30 = 40).575 (X = 0.394 +.8 =.575). For more information about selecting a back manual unlocking button kit for a frame, see the following table: Mounting part* thickness (X) (mm in) Model No. Rear unlocking button type When installing an -K2 D-L5 with a rear unlocking button directly MS-SG-22 33 < X 43.299 < X.693 MS-SG-23 23 < X 33 0.906 < X.299 * The mounting part is a frame or a panel that the product is mounted on. 33.299 25.5.004 60.5 2.382 ITY SG-B/SG-A SG-C SG-D SG-E SD3-A Note : With the dimension, the rear unlocking button rod does not touch the hole even when the safety switch moves sideways.