INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

Similar documents
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

MODEL SS INSTALLATION INSTRUCTIONS

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

INSTALLATION INSTRUCTIONS MODELS S S S S SSN S SSW SSN SPRINKLER PUMPS

Material required for drilled well application (indoor use only)

INSTALLATION INSTRUCTIONS MODEL Z Z Z Z 1.5 HP 115/230V Z Z 2.0 HP 115/230V Z Z

MODEL H INSTALLATION INSTRUCTIONS

MODEL P INSTALLATION INSTRUCTIONS

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

MODEL INSTALLATION INSTRUCTIONS. 12 Volt UTILITY PUMP

HALLMARK INDUSTRIES INC

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

PRESSURE BOOSTER 150

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

PRE-PLUMBED SEWAGE SYSTEM

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

ESE Series Cast Iron Sewage Pumps

OWNER S MANUAL CONVERTIBLE JET PUMP

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

STAR STOP SHALLOW WELL JET PUMP

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Owners Manual: - Pumps

SHALLOW WELL JET PUMP

2 Wire Plus Ground 3 Wire Plus Ground IL0655

Installation & Operating Manual

Installation Instructions and Parts Manual CPJ SERIES JET PUMPS. Shallow Well Jet Pumps. Convertible Jet Pumps. Ejectors (Purchase separately)

OWNERS GUIDE TO INSTALLATION AND OPERATION OF 1/2-5 HP, 5, 7, 10, 15, 19 & 27 GPM 4 SUBMERSIBLE PUMPS

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

HALLMARK INDUSTRIES INC. Deep Well Submersible Pumps Operating & Installation Instructions

INSTALLATION INSTRUCTIONS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

Installation Operation Parts

SPECIFICATIONS: Tank Size: 80 gallons PUMP RPMs: 1050 CFM: 40PSI; 90 PSI Max Pressure: 150 PSI Thermal overload protection

Jet Pumps. Convertible Shallow Well. 6/13 Rev (3/14)

Owner s Manual & Safety Instructions

Vertical Jet Pumps. SSJ Series. Call OWNER S MANUAL

SS/SSH Submersible Pump. Owner s Manual

LAWN SPRINKLER, IRRIGATION PUMP

8000 / 10,000 / 12,000

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

GARDEN HOSE UTILITY PUMP

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

SUNC3000 / Item #40885

Please contact your supplier (supplying dealer or contractor) if service is necessary or if you have any questions or need further assistance.

Installation Instructions

Models 3305P, 3307P, 3310P

SELF PRIMING CHEMICAL SERVICE PUMPS

Matala. VersiFlow Series. Instruction and Maintenance Manual

Operating Instructions & Parts Manual

Model &

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

QWIK JON ULTIMA 203 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT

Installation & Operating Manual

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

GeyserMax-Flow Series

June14. Type

Cascade Owners Manual

M o d e l J E U. Self Priming Jet Pump. Operating Instructions, Installation & Maintenance Manual. Ebara Fluid Handling

INSTALLATION AND SERVICE MANUAL

MH Series - Horizontal Multistage Pump OWNER'S MANUAL

Grind Pro Series. Operator Manual. Manufacture by:

Utility Distribution System

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

Potable Water Convertible Jet Pumps

WELDING FUME EXHAUSTERS & ARMS

Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual

TECHNICAL BROCHURE BHSJ. Basic Convertible Pump HSJ MULTI-STAGE CONVERTIBLE JET PUMPS - 60 HZ

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

6L Oil-less Air Compressor 53103

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Centrifugal Constant Pressure Control

DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

Medi-Flow. Model M101 & M101D Medicator Instructions GETTING TECHNICAL ASSISTANCE

Installation & Operating Manual

SUPER PUMP OUT SYSTEM

User s Manual D-Series Blowers and Exhausters

6-12 WIDESPREAD 6-12 W. Cleopatra Series INSTRUCTION GUIDE SAVE THIS INSTRUCTION GUIDE

INSTALLATION & OPERATION MANUAL

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

MODEL CJ-200E CoilJet Portable HVAC Coil Cleaning System

Owner s Manual Drill and Light Weight Portable Utility Pumps

Transcription:

INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Blvd. Dagenais West LAVAL (QUEBEC) CANADA H7L 5X9 MODELS 503132S 503332 503232S 503732 TEL : 514.337.4415 FAX : 514.337.4029 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping. However, occasional damage may occur due to rough handling. Carefully inspect your pump for damages that could cause failures. Report any damage to your carrier or your point of purchase. SHALLOW WELL & CONVERTIBLE JET PUMPS Please read these instructions carefully. Failure to comply to instructions and designed operation of this system, may void the warranty. PAGE 3 PAGE 8 2014 BUR-CAM Printed in Canada 510078

Safety Instructions : This fine pump that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures: A B C D CHECK WITH YOUR LOCAL ELECTRICAL AND PLUMBING CODES TO ENSURE YOU COMPLY WITH THE REGULATIONS. THESE CODES HAVE BEEN DESIGNED WITH YOUR SAFETY IN MIND. BE SURE YOU COMPLY WITH THEM. WE RECOMMEND THAT A SEPARATE CIRCUIT BE LEAD FROM THE HOME ELECTRICAL DISTRIBUTION PANEL PROPERLY PROTECTED WITH A FUSE OR A CIRCUIT BREAKER. WE ALSO RECOMMEND THAT A GROUND FAULT CIRCUIT BE USED. CONSULT A LICENSED ELECTRICIAN FOR ALL WIRING. THE GROUND TERMINAL ON THE THREE PRONG PLUGS SHOULD NEVER BE REMOVED. THEY ARE SUPPLIED AND DESIGNED FOR YOUR PROTECTION. NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DO NOT ONLY UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER PLUG FROM THE RECEPTACLE. Monthly Mandatory check-up : 1. Inspect the pump for any obvious condition that necessitates cleaning, correction, adjustement or repair. 2. Clear the surrounding of any paper, leaves or other debris. 3. Assure that the pump is secure for proper operation. 4. Assure that there is adequate clearance from any combustible materials or stucture. Stored materials must be kept away from the pump. Shelves or cabinet structures must not be in close proximity over the pump. 5. Assure that the motor is securely plugged into a proper GFCI electrical outlet 6. Test the GFCI outlet by pressing its test switch. This should prove that the outlet is energized and will trip off to protect against a ground fault. Be sure to reset the GFCI by pressing its reset switch. 7. Observe that the plumbing can carry the water safely into the residence. Material required for drilled well application (indoor use only) Shallow well pump installation Desired length of polyethylene 1 pipe, 100 PSI, CSA or UL approved, to link up from pumping level to pump. 1 1 foot valve (750756 or 750752P). 1 well seal, as per well casing diameter (750929 6 x 1 ). 1 1 well seal elbow (750860). 1 1 male adaptor (750865 or 750871) and 1 1¼ to 1 male adaptor (150181). 8 1 stainless steel clamps (750885). Teflon tape. Deep well pump installation Desired length of polyethylene 1 and 1¼ pipe, 100 PSI, CSA or UL approved, to link up from pumping level to pump. 1 1¼ foot valve (750757 or 750753P). 1 well seal, as per well casing diameter (750926 6 x 1¼ x 1 ). 1 1 well seal elbow (750860). 1 1¼ well seal elbow (750861). 1 1¼ venturi adaptor (750864). 2 1 male adaptors (750865 or 750871) and 1 1¼ male adaptor (750866 or 750872). 8 1 stainless steel clamps (750885). 8 1¼ stainless steel clamps (750886). Teflon tape. Tools Screwdrivers, hacksaw to cut pipe, knife to assist in pipe cutting, round file to smooth pipe ends, pipe wrench, adjustable wrench to tighten fittings, propane torch and welding material. 2

APPLICATION (503132S and 503232S) This pump is designed for shallow well installation for water levels no deeper than 25 feet. CAPACITY : 1/2 HP 3/4HP 5 815 865 US GPH 10 715 755 US GPH 15 630 665 US GPH 20 550 575 US GPH 25 500 530 US GPH FRICTION LOSS IN PIPE NOT INCLUDED FEATURES Easy to prime pump body. Totally enclosed, fan cooled motor, bearing to bearing. Built for a continuous use. Full time connected run capacitor, to eliminate starting wear vs regular motor. Thermal and overload protection. Noryl impeller, built-in injector 1/2 HP, 115 / 230 VAC, 60 Hz, 8.6 A / 4.3 A (at start :15 A / 7.5 A). 3/4 HP, 115 / 230 VAC, 60 Hz, 8.8 A / 4.4 A. (at start :15 A / 7.5 A). STEP 1 INSTALLATION STEPS We recommend that you install your pump in a clean and dry location where there is adequate room for servicing at a later date. Protection from freezing temperatures and good ventilation should be considered as well, to provide the pump an environment for long life. Locating the pump as close as possible to the water source will reduce friction losses encountered in the suction pipe. Friction losses in the suction pipe must be taken into consideration when the horizontal offset is greater than 50 feet. The suction pipes should be increased from 1 to 1 1/4. This will reduce friction losses and allow the pump to give maximum performance. A new well should be checked to determine that it is free from sand. Sand will damage the seal and the impeller. Have your well driller clean the well before your installation. Never run the pump dry. Damage to the seal may occur. Fill pump body and suction pipe with water before turning on the power. VERY IMPORTANT Please be advised that the Fluomac Electronic unit is a state of the art product and will give you years of trouble free service. However, if the unit cycles ''ON and OFF'', this means there is a leakage in your plumbing. For example: A toilet leak, the leakage must be repaired to maintain the system pressure. Furthermore, if you are pumping water from a sand point or if you have indication that your well may contain sand, a sand filter must be installed in the suction of the pump. Sand will damage the unit, due to its abrasive nature and will void warranty. For more information, we are enclosing a brochure on our Sand Filter model # 750896, which is available from any Burke Retailers or Wholesalers. In the meanwhile, if you have any questions concerning your pump, please contact us on our toll free number 1-800-361-1820 before returning the pump to the point of purchase. The above conditions are not on warranties. The warranty covers manufacturing defects only. THE RUN OF HORIZONTAL PIPE FROM THE TOP OF YOUR WELL INTO THE HOUSE, WHERE YOUR PUMP WILL BE LOCATED, MUST BE INSTALLED IN A TRENCH, BELOW THE FROST LEVEL OF YOUR AREA. 3

SHALLOW WELL APPLICATION SEE DIAGRAM ON PAGE 5 STEP 2 STEP 3 STEP 4 Cut the desired length of poly pipe to run from the top of the well to the pumping level. Smooth the pipe cuttings with your round file. (Check that no cut-out parts are left inside of pipe. This may block pump injector or impeller). Tape male adaptor threads with teflon tape and thread adaptor into the foot valve. Slide 2 stainless steel clamps over one end of pipe and use torch to soften pipe. Insert the male adaptor and foot valve into this pipe end. Tighten clamps with screwdriver when cool. For security against leaks, we suggest to install 2 stainless steel clamps on each adaptor. Insert the well seal elbow through the opening of the seal. Slide 2 stainless steel clamps over the free end of the previously cut pipe and soften pipe with your torch. Attach pipe to the well seal elbow (end protruding at bottom of well seal). Tighten clamps with screwdriver when cool. Install the well seal and piping assembly into your well casing. Tight down the well seal bolts using your adjustable wrench. To facilitate servicing at a later date, you may use a pitless adaptor and a sealed well cap instead of an elbow and a well seal as describe in steps 3 and 4. STEP 5 STEP 6 STEP 7 for sand or well points Install your pump in the house, on a sound foundation, as close as possible to the basement wall. Locate the suction inlet in the front of the pump. Thread an adaptor into inlet using teflon tape. Do not over tighten. Cut the desired length of pipe from pump location to the well seal and connect both ends using the previous way, with stainless steel clamps and torch. Before connecting your pipe to the pump, fill the succion line with water. Do not fill in your trench to the house until you have checked for any leaks in your connections or trouble in your water system. Sand or well points are limited to areas where water bearing sand or gravel lies below the surface, and where there are no boulders or rocks to interfere with the driving into the ground of the point. The amount of water any one well point will supply is usually rather limited. Sometimes, it is necessary to use more than one point to increase the supply of water, entering to the pump s suction. THE IMPORTANT INSTALLATION STEP IN USING WELL POINTS IS THAT A CHECK VALVE MUST BE USED IN THE SUCTION PIPE LEADING TO THE SUCTION INLET, AS CLOSE TO THE PUMP AS POSSIBLE, TO KEEP SUCTION LINE AND PUMP WELL PRIMED. 4

SHALLOW WELL APPLICATION STEP 5 Install your pump and thread an adaptor into inlet. STEP 6 Cut poly pipe and connect both ends. STEP 3 Insert well seal elbow through the seal and attact to pipe. STEP 4 Install well seal and piping into well casing. Well point optional installation STEP 7 You may install one or more sand points to increase the supply of water. Check valve, close to pump. STEP 2 Cut poly pipe and install the check valve. 5

PRIMING INSTRUCTIONS PLEASE, FOLLOW THESE STEPS TO EASILY PRIME YOUR PUMP. STEP 8 STEP 9 STEP 10 Connect your discharge line, using a ball valve, as illustrated. (Photo 1) Fill the suction line with water and connect it to the suction inlet. (Photo 1) STEP 10 Remove the plug of the priming pipe and fill the pump body with water. (Photo 1) STEP 8 1 flexible hose for 3 to 5 ft. STEP 11 Screw the plug to the priming pipe using teflon tape. (Photo 2) STEP 11 STEP 9 PHOTO 1 STEP 12 Connect the pump. The pump should delivered water to the plumbing line within 30 secondes. If not, unplug the pump and repeat from step 10. In accordance with the length of your suction line, you may have to repeat these steps a few times. PHOTO 2 STEP 12 NOTE : After installation, if the pump is cycling on-off and/or comes on when you are not visibly using water, the pump is not defective. It means you have a leak on the discharge side of the pump. The leak must be localised and needs to be repaired. If you need assistance to determine same, please call 1 800-361-1820. The pump is warrantied by the manufacturer and you must call us to determine procedures. The pump can not be returned to the point of purchase without our prior consent. 6

BOOSTER PUMP APPLICATION NEVER RUN THE PUMP DRY 2 PRESSURE GAUGE OPEN Minimum pipe size 1 STEP 1 To use this pump for pressure boosting, read carefully the instructions for shallow well application, then connect the pump to your water supply as per the pictures on right. FLOW 3 CLOSE TO OPERATE THE PUMP STEP 2 Use appropriate union (not shown) to connect pipes for an easy service at a later date. STEP 3 If your incoming pressure is higher than 20 PSI, install a pressure reducer (not shown) between the ball valve #1 and the pump, setted to 20 PSI. This will prevent an excess of pressure on the house distribution piping. FLOW STEP 4 Install a pressure gauge as per the pictures on the right, to monitor the pressure in piping. OPEN 1 STEP 5 STEP 6 Set the ball valves as per to operate the pump picture. Open the nearest faucet and connect the pump to an electrical outlet. When all the air will be remove from the piping, close the faucet. The pump will stop after 7 to 10 seconds. Then, it will turn on when a faucet is open. FLOW 3 2 PRESSURE GAUGE CLOSE Minimum pipe size 1 WARNING In a booster pump application the incoming pressure must never be higher than 20 to 25 PSI. FLOW OPEN CLOSE TO SERVICE THE PUMP 1 7

Important notice: For the models 503332 and 503732, the priming instructions and the booster pump application are identical to the models 503132S and 503232S. Refer to pages 7 and 8. Your ejector is factory pre-assembled with the venturi 510066.2, for an optimum performance when the pumping level is between 25 to 60 (7.5 meters to 18 meters) depth, in reference to the pump position. So, this is a deep well application mode. The ejector is positioned into the well and is connected to the pump using 2 pipes (see page 13). If the pumping level is deeper than 60 (18 meters) in reference to the pump position, it is mandatory to unscrew the pre-assembled venturi and to replace it by the venturi 510066.3, also as a deep well mode application with the ejector positioned into the well. For deep well application mode, 60 and deeper. Factory pre assembled, for deep well application mode, 25' à 60'. 510066.3 510066.2 510066.1 9/32" 21/64" 31/64" 7.1mm 8.3mm 12.2mm For shallow well application mode. In the case of a pumping level lower than 25 (7.5 meters), unscrew the pre-assembled venturi and replace it by the venturi 510066.1. Then screw the ejector to the pump body. This becomes a shallow well mode application where only one pipe is required to pump water (see page 11). Use the included flow control valve to connect your pump to your home plumbing distribution pipe system. Install this valve to the pump discharge and close the valve completely by turning the top screw clockwise. Then, turn the screw counter-clockwise for one turn only and proceed to the following priming process of the pump. Follow all these inside step by step instructions to install your pump. Use teflon tape on all threads. (1) Install the pump discharge fittings as illustrated. (2) Fill the suction line with water and connect it to the suction inlet. (3) Remove the priming plug and fill the pump body with water. (4) Screw the plug to the priming inlet. (5) Connect the pump to the receptacle. The pump should deliver water to the plumbing line within 30 seconds. If not, unplug the pump and repeat the process at step 3. After priming the pump, you can adjust Flow control valve the flow control valve to obtain the best performance of the pump. Remember that when you open this valve, you reduce the suction capacity. This valve is used to balance the discharge flow with the suction requirement. The deeper your suction distance, the more closed the valve should be for optimum performance. 1 Priming plug. 3-4 1 Flow control valve Discharge connection 5 Suction connection 2 8

APPLICATIONS (503332 and 503732) This pump is designed for shallow well installation for water level up to 25 feet, with injector screwed on pump body; or for deep well installation for water level up to 85 feet, with 2 pipes and injector down in the well. CAPACITY AT 20 PSI. SHALLOW WELL DEEP WELL 1/2 HP 3/4 HP 1/2 HP 3/4 HP 5 900 950 10 800 850 30 500 525 15 650 700 40 400 425 20 450 500 50 300 325 25 300 350 80 150 175 US GPH US GPH FEATURES High performance noryl impeller.. Industrial motor totally enclosed, fan cooled. Full time connected run capacitor, to eliminate starting wear vs regular motor. Thermal and overload protection. Built for a continuous use. 1/2 HP, 115/230 VCA, 60 Hz, 8.6 A/4.3 A. 3/4 HP, 115/230 VCA, 60 Hz, 8.8 A/4.4 A. FRICTION LOSS IN PIPE NOT INCLUDED. (at start : 15 A/7.5 A) INSTALLATION STEPS STEP 1 We recommend that you install your pump in a clean and dry location where there is adequate room for servicing at a later date. Protection from freezing temperatures and good ventilation should be considered as well, to provide the pump an environment for long life. Locating the pump as close as possible to the water source will reduce friction losses encountered in the suction pipe. Friction losses in the suction pipe must be taken into consideration when the horizontal offset is greater than 50 feet. The suction pipes should be increased from 1 to 1¼. This will reduce friction losses and allow the pump to give maximum performance. A new well should be checked to determine that it is free from sand. Sand will damage the seal and the impeller. Have your well driller clean the well before your installation. Never run the pump dry. Damage to the seal may occur. Fill pump body and suction pipe with water before turning on the power. before turning on the power. VERY IMPORTANT Please be advised that the Fluomac Electronic unit is a state of the art product and will give you years of trouble free service. However, if the unit cycles ''ON and OFF'', this means there is a leakage in your plumbing. For example: A toilet leak, the leakage must be repaired to maintain the system pressure. Furthermore, if you are pumping water from a sand point or if you have indication that your well may contain sand, a sand filter must be installed in the suction of the pump. Sand will damage the unit, due to its abrasive nature and will void warranty. For more information, we are enclosing a brochure on our Sand Filter model # 750896, which is available from any Burke Retailers or Wholesalers. In the meanwhile, if you have any questions concerning your pump, please contact us on our toll free number 1-800-361-1820 before returning the pump to the point of purchase. The above conditions are not on warranties. The warranty covers manufacturing defects only. THE RUN OF HORIZONTAL PIPE FROM THE TOP OF YOUR WELL INTO THE HOUSE, WHERE YOUR PUMP WILL BE LOCATED, MUST BE INSTALLED IN A TRENCH, BELOW THE FROST LEVEL OF YOUR AREA. 9

SHALLOW WELL APPLICATION SEE DIAGRAM ON PAGE 11 STEP 2 STEP 3 STEP 4 Cut the desired length of poly pipe to run from the top of the well to the pumping level. Smooth the pipe cuttings with your round file. (Check that no cut-out parts are left inside of the pipe. This may block pump injector or impeller). Tape male adaptor threads with teflon tape and thread adaptor into the foot valve. Slide 2 stainless steel clamps over one end of the pipe and use torch to soften pipe. Insert the male adaptor and foot valve into this pipe end. Tighten clamps with screwdriver when cool. For security against leaks, we suggest to install 2 stainless steel clamps on each adaptor. Insert the well seal elbow through the opening of the seal. Slide 2 stainless steel clamps over the free end of the previously cut pipe and soften pipe with your torch. Attach pipe to the well seal elbow (end protruding at bottom of well seal). Tighten clamps with screwdriver when cool. Install the well seal and piping assembly into your well casing. Tight down the well seal bolts using your adjustable wrench. To facilitate servicing at a later date, you may use a pitless adaptor and a sealed well cap instead of an elbow and a well seal as describe in steps 3 and 4. STEP 5 STEP 6 STEP 7 for sand or well points Install your pump in the house, on a sound foundation, as close as possible to the basement wall. Locate the suction inlet in the front of the injector. Thread an adaptor into inlet using teflon tape. Do not over tighten. Cut the desired length of pipe from pump location to the well seal and connect both ends using the previous way, with stainless steel clamps and torch. Do not fill in your trench to the house until you have checked for any leaks in your connections or trouble in your water system. Sand or well points are limited to areas where water bearing sand or gravel lies below the surface, and where there are no boulders or rocks to interfere with the driving into the ground of the point. The amount of water any one well point will supply is usually rather limited. Sometimes, it is necessary to use more than one point to increase the supply of water, entering to the pump s suction. THE IMPORTANT INSTALLATION STEP IN USING WELL POINTS IS THAT A CHECK VALVE MUST BE USED IN THE SUCTION PIPE LEADING TO THE SUCTION INLET, AS CLOSE TO THE PUMP AS POSSIBLE, TO KEEP SUCTION LINE AND PUMP WELL PRIMED. 10

SHALLOW WELL APPLICATION STEP 5 Install your pump and thread an adaptor into inlet. STEP 6 Cut poly pipe and connect both ends. STEP 3 Insert well seal elbow through the seal and attact to pipe. STEP 4 Install well seal and piping into well casing. Well point optional installation STEP 7 You may install one or more sand points to increase the supply of water. Check valve, close to pump. STEP 2 Cut poly pipe and install the check valve. 11

DEEP WELL APPLICATION SEE DIAGRAM ON PAGE 13 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 STEP 8 Locate your injector body in your package. Using teflon tape, screw the 1¼ venturi adaptor over the injector venturi (black tube), into the 1¼ opening of injector body. Install the 1 male thread adaptor in the 1 opening in injector body. Securely tighten both adaptors with pipe wrench. With teflon tape on threads, install a 1¼ nipple into the 1¼ foot valve, then screw this assembly into the 1¼ bottom opening of the injector. Cut the desired length of 1 and 1¼ poly pipes to run from the top of the well to the pumping level. Smooth the pipe cuttings with your round file. (Check that no cut-out parts are left inside of the pipe. This may block pump injector or impeller). Slide 2 stainless steel clamps over one end of each pipe and use torch to soften pipe. Fix the 1 and 1¼ pipes respectively on the 1 adaptor and 1¼ venturi adaptor. Tighten clamps with screwdriver when cool. For security against leaks, we suggest to install 2 stainless steel clamps on each adaptor. Insert both well seal elbows through their opening of the seal. Slide 2 stainless steel clamps over the free ends of the previously cut pipes and soften pipes with your torch. Attach pipes to the well seal elbows (ends protruding at bottom of well seal). Tighten clamps with screwdriver when cool. To facilitate servicing at a later date, you may use a pitless adaptor and a sealed well cap instead of an elbow and a well seal as describe in steps 3 and 4. Install the well seal and the injector piping assembly into your well casing. Tight down the well seal bolts using your adjustable wrench. Install your pump in the house, on a sound foundation, as close as possible to the basement wall. Locate the openings in the front of the pump body. Thread respectively 1 and 1¼ adaptors into corresponding openings using teflon tape. Do not over tighten. Cut the desired length of pipes from pump location to the well seal and connect both ends using the previous way, with stainless steel clamps and torch. Do not fill in your trench to the house until you have checked for any leaks in your connections or trouble in your water system. 12

DEEP WELL APPLICATION STEP 7 Install your pump and thread adaptors into their respective opening. STEP 8 Cut 1" and 1 ¼" poly pipes and connect both ends. STEP 5 Insert well seal elbows thru the seal and attach to pipe. STEP 6 Install well seal and piping into well casing. STEP 4 Cut 1" and 1¼" poly pipes. STEP 2 Screw 1¼" venturi adaptor and 1" adaptor into injector body. STEP 3 Install 1¼" nipple into 1¼" foot valve, then screw in injector. 13

REPAIR PARTS Ref Parts Descriptions Ref Parts Descriptions 1 510054 Motor 1/2 HP 1 510054-2 Motor 3/4 HP 2 510055 Motor Screws (4) 3 510053 Seal Plate O-Ring 4 510052 Mecanical Seal 5 510048 Impeller 6 510047 Diffuser 7 510065 Diffuser Plate 8 510051 Diffuser Plate O-Ring 9 510050 Diffuser Plate Washers (3) 10 510049 Diffuser Plate Screws (3) 11 510069 Venturi 12 510046 Nozzle 13 510045 Pump Body 14 750769 1/4" Pressure Gauge (not shown) 15 510077 Capacitor (not shown) 16 506375 SS Priming tube 17 506377 Priming plug and washer 18 506376 Discharge fitting 19 600600GP Fluomac 18 19 03 04 05 06 07 09 16 17 01 10 02 11 12 13 08 503132S / 503232S 2014 Repair parts may be ordered from your autorized point of sale or from BUR-CAM PUMPS 14

REPAIR PARTS Ref Parts Descriptions Ref Parts Descriptions 1 510054 Motor 1/2HP 1 510054-2 Motor 3/4HP 2 510055 Motor Screws (4) 3 510053 Seal Plate O-Ring 4 510052 Mechanical Seal 5 510048 Impeller 6 510047 Diffuser 7 510065 Diffuser Plate 8 510051 Diffuser Plate O-Ring 9 510050 Diffuser Plate Washers (3) 10 510049 Diffuser Plate Screws (3) 11 510072 Flow Regulator 12 510058 Pump Body 13 510061 Ejector Gasket 14.1 510066.1 Short Venturi 14.2 510066.2 Long Venturi (25'-60') 14.3 510066.3 Long Venturi (60 +) 15 510070 Nozzle 16 510062 Ejector Body 17 510063 Washers (2) 18 510064 Ejector Cap Screws (2) 19 750969 1/4" Pressure Gauge (not shown) 20 510077 Capacitor (not shown) 21 506375 SS Priming tube 22 506377 Priming plug and washer 23 506376 Discharge fitting 24 600600GP Fluomac 23 24 22 03 04 05 06 11 21 01 07 09 10 02 12 13 14 15 16 08 17 18 503332 / 503732 2014 Repair parts may be ordered from your autorized point of sale or from BUR-CAM PUMPS 15

TROUBLE SHOOTING GUIDE CHECKLIST NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DON T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE. TROUBLE PROBABLE CAUSE ACTION Motor does not run. Switch is off position Blown fuse Tripped breakerù Dirty pressure switch Defective pressure switch Defective motor Turn switch to on position Replace Reset Clean Replace Replace Motor runs but no water is delivered. Pump does not deliver to full capacity. Pump does not shut off. Pump starts and stop too often. Air spurts from fawcets. Pump not primed Leaky suction line Foot valve plugged Ejector nozzle clogged Water level below foot valve Suction lift to great Improper voltage Water level below foot valve Ejector nozzle clogged Excessive friction in pipe Improper voltage Leaky discharge line Motor not up to normal speed Improper setting of pressure switch Ejector nozzle clogged Pressure tank waterlogged Leaky foot valve Leaky suction line Foot valve do not close properly Pressure switch out of adjustment Leaky discharge line (toilet etc.) Leaky suction line Gaz in water Airlogged tank (galvanized) Prime with clean water Check pipe and pipe connections Clean Clean Check foot valve level Water level lower than lift capacity Check voltage Check foot valve level Clean Too small or dirty pipe Check voltage Check all pipes for leak Check power cable and voltage Reset or replace Clean Drain tank and restart Replace Check pipe and pipe connections Clean or replace Adjust on/off setting Check all pipes for leak Check pipe and pipe connections Check and consult factory Replace air volume control TO THE END CONSUMER If you have any problems with the product, before advising the store, where you ve purchased the pump, please contact us at 514 337-4415, and ask for our sales department, and they will be pleased to help you with any questions you might have, concerning your installation. 16