Conduit and Wire. Wire and Cable Whips. Bus Duct, Cable Trays, Overhead or Under Floor Raceways, Strut or Channel Systems

Similar documents
Put the Power in Your Hands

Flexible, Customizable Power Solutions for Mission Critical Success

Flexible, Customizable Power Solutions for Mission Critical Success

Flexible, Customizable Power Solutions for Mission Critical Success

PowerWave Bus System. For More Information Use your QR Reader THE NEXT GENERATION OF FLEXIBLE POWER DISTRIBUTION

168 Georgetown Road Canonsburg, PA USA Phone: Toll Free: Fax:

PDI PowerWave 2 Bus System

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design

COMPACT BUSWAY 40 & 60 AMP HOUSING

Raising the bar for flexible power.

Product Selection Guide

FiberGuide Fibre Management Systems

FACT SHEET Standard: Electrical Safety

Product Selection Guide: T5 Series- 250, 400 & 800 Amps

BEST PRACTICE CEBP9801. Controls Engineering COE. DATE: May, 1998 Delphi Controls COE Best Practice - Flexible Utility Connections

University of California, San Diego Cal (IT) 2 Technical Assignment #2. Brian Smith

INTELLIGENT MEDIUM POWERBAR impb

Global Product Selection Guide

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

Snake Bus Power Distribution

INTELLIGENT MEDIUM POWERBAR

POWERBUS 225 Busway and Plug-In Units

Metal Raceway Systems. tomorrow. Wiremold Metal Raceway. Innovative from Day One.

Product Selection Guide

SURFACE TRACK (120/250V) SPECIFICATIONS

PowerWave 2 TM Bus System

LED Power Systems. As retailers and brands enhance their in-store. for Retailers and Brands

BUSWAY Low Voltage (Pow-R-Flex)

Connecting Lighting & Controls

ECET Distribution System Protection. Overcurrent Protection

Power Mod. Introduction.

Plug-In Raceway - Power

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

LSI 20 Series 30A, 120V Surface Busway Components 1

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

LB - LIGHTING BUSWAY 25-40A

Bright Ideas for Custom Power Solutions

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Service Entrance Methods

Solar Combiner Solutions

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

Busway. Siemens STEP 2000 Course. STEP 2000 Courses distributed by

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium

Grounding Of Standby & Emergency Power Systems

UNDERGROUND SERVICES - SECONDARY

GE Industrial Solutions. From houses to high-rises GE Residential products and solutions

T&B Cable Tray. In this section...

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

Pow-R-Flex low ampere busway

Electrical Wiring Practices

Product Selection Guide: T3 Series- 100 & 225 Amps

NEC REQUIREMENTS FOR GENERATORS

Data Bulletin. Wire Temperature Ratings and Terminations INTRODUCTION WHY ARE TEMPERATURE RATINGS IMPORTANT?

Evaluating Water-Damaged Electrical Equipment

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections

Power and Cooling. Chassis Power System

Transfer Switch TS-50. Owner s Manual

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

G20GB12 Gry 3W1CKT Plugmold. Features Made in USA STEEL RACEWAY, THERMOPLASTIC RECEPTACLE Number of Outlets 48 Outlet Center Distance

Solar Combiner Solutions

Elegance Electrician s Installation Guide

Tradition. Technology. Innovation.

Bring power safely and conveniently to wherever

Understanding Electrical Terms

G20GB606 PLGMD 6'SGL CRT 6" 2000 Gray. Manufacturer Information. Packaging Carton 1 Package 2 Weight Per each Description

DIY 15 Amp Portable Generator Transfer Switch

OCEAN COUNTY ARES EMERGENCY GENERATOR USE By WX2NJ. The following was taken from September and October Ocean County ARES Newsletters in 2012:

New Product Bulletin. PowerCINCH The Modular Power Distribution and Motor Control Connection System for Machinery Applications

systems Systems Emergency Lighting Inverter 120 or 277V 60 Hz Power

Midwest Dry Type Transformers

2016 Photovoltaic Solar System Plan Review List

TONY S TECH REPORT. Basic Training

Busway Construction. Bus Bars

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

Installation and Construction Notes for EVSE4

STL. Series. Emergency Lighting Inverter 3kW to 160kW Central System

Design Standards NEMA

Choosing Household Wiring for Low EMF

POWERFLOW. Your Idea System! Series. Series BUSWAY BUSBAR TRUNKING SYSTEM 630A 6300A ELECTRIC COMPAC ELECTRIC COMPAC ELECTRIC MAN. CO., LTD.

TECH XP250 INSTALLATION AND OPERATION MANUAL. Manufacturer of UL Listed Products.

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Transfer Switch GPTS 30

essentia audiotoo s User Manual Rev 2.0 September 2015 Mains Multiplier 5 Mains Multiplier 7 Mains Multiplier 8

BusBars Feed Through Terminals 114 PowerPosts 115. Terminal Blocks

Design Standard. Purpose: Design Standard:

ProFlex HOT MELT SYSTEMS. The Ultimate In High-Volume Production And Flexibility.

Generator Fire Safety: Generator assemblies should be located outside the building.

III. Substation Bus Configurations & Substation Design Recommendations

XP600/1100/2000 INSTALLATION AND OPERATION MANUAL

A. Submit manufacturer's literature and technical data before starting work.

smissline Description

NEC 2011 Code Changes

Owners Installation, Operation, and Safety Manual

Overcurrent Protection (2014 NEC) (Homestudy)

GET GROUNDED. Renewable Energy System Grounding Basics

STABILINE. Surge Protective Devices. PT1 Series Type 2 SPD. Installation, Operation and Maintenance Manual

SECTION WIRING DEVICES

TECH XP600/1100 INSTALLATION AND OPERATION MANUAL. Manufacturer of UL Listed Products.

Transcription:

Conduit and Wire Must be scrapped whenever reconfiguration of the electrical layout is needed. Many runs may be needed for applications with a high volume or high density of electrical loads. It is labor intensive to install or add more loads, and typically requires a high number of homeruns. Wire and Cable Whips Can easily become a confusing jungle which can not be maintained or relocated as facility electrical requirements change. Cost of power outages, and running replacement or new cables can be extremely expensive. Bus Duct, Cable Trays, Overhead or Under Floor Raceways, Strut or Channel Systems Are difficult to relocate electrical loads; can end up with far more wires and homeruns. The old, conventional industrial bus duct systems are much larger, heavier, harder to work with, expensive and overkill in many applications. 2 For A Representative or Distributor Near You, Call: 800.245.6378 or Visit Our Website at www.uecorp.com.

For 40, 50 or 60 Amp, 480 Volt, Single or Three-Phase You Simply INSERT & SNAP It s that simple. Whether it s a light fixture, outlet box, drop cord or pigtail just insert the plug-in unit into the busway slot until it snaps into locked position. For 60 or 100 Amp, 600 Volt, Single or Three-Phase You Simply INSERT, TURN & LOCK It s that simple. Whether it s a light fixture, outlet box, fused box, drop cord or circuit breaker box just squeeze, turn and relocate in seconds. For 100, 160 or 225 Amp, 600 Volt, Single or Three-Phase You Simply INSERT, TURN & LOCK It s that simple. Whether it s an outlet box, fused box, drop cord or circuit breaker box just turn, remove and relocate in seconds. 3

The Track Busway Concept STARLINE is the first system to be called a track busway system. Introduced in 1988, it continues to lead the way in changing the way you think of power distribution. The track busway concept refers to the continuous access plug-in slot or track, in the bottom of the busway sections. Plug-in units can be inserted into the busway at the point-of-use, as close together or far apart as desired. And product design is in accordance with NEC Article 368, Busways, conforms with IEC standard for busways, and standard systems are UL Listed. ISO 9000-2000 Compliant, for quality standards. Plug-in units include simple duplex receptacles, fused disconnects, drop cords with cord receptacles or even quad boxes, power poles, circuit breakers in a wide variety of configurations and three-phase disconnects. Compact 40, 50 & 60 Amp Systems Power Feed Fast Installation and Reconfiguration STARLINE s preassembled modular design can be installed in less than half the time of any conventional conduit and wire method and at a considerable cost savings. All system components can be disassembled and reused at new locations. Plug-in units can be added, removed or relocated instantly with in-house personnel, with no additional installation costs. Reliability is the backbone design criteria for all STARLINE Track Busway systems. The unique compression connection concept at the connection points assures that the connections run cooler than the conductor busbar itself. Scalability allows the user to install only what is needed without tying up capital funds for initial unneeded material. The user can simply add to busway sections and plug-in units as the need arises OR simply relocate a unit from another location in a matter of seconds without shutting down the power. 100, 160 & 225 Amp Systems Power Feed Bus Connector For more details about STARLINE Track Busway, call the 800 number or visit the website listed below. 4 For A Representative or Distributor Near You, Call: 800.245.6378 or Visit Our Website at www.uecorp.com.

1.62" 1.79" End Cap Tee 1.66" 2.58" Housing Section B40 40Amp B50 50Amp B60C 60Amp B60 60Amp Support Hardware Elbow B100C 100Amp 2.38" Support Hardware 4.19" End Cap B100 100Amp B100NG 100Amp/ 200% Neutral Isolated Ground B225G 225Amp Isolated Ground B225 225Amp Tee End Piece Elbow 5

In Industrial Manufacturing & Assembly Plants The design flexibility and the ability to make changes quickly and easily have made STARLINE the electrical distribution and factory lighting standard by today s leading manufacturers and high-tech companies. Entire systems can be setup in a matter of hours with relocation of power drops in minutes, often without outside labor. In College Engineering Labs & Vo-Tech Shops Quick change over and the ability to plug-in the widest possible selection of plug-in units on the same system, often at different voltages, has made STARLINE the system of choice for Engineering and Research Labs at leading Universities, Colleges, and Vo-Tech Shops. In Retail Outlets STARLINE s Compact Series are the newest addition, and are ideal for retail power supply and lighting. The snap-in plug allows the retail owner to use any light fixture. Retail-style drop cords or power poles provide single or three-phase power to aisles, gondolas, check-outs and perimeters throughout the store. 6 For A Representative or Distributor Near You, Call: 800.245.6378 or Visit Our Website at www.uecorp.com.

In Test Labs Custom plug-in units, shown here with breakers and dual drop cords, solve a high-density problem. Custom units can often be designed to meet special customer needs, with quick availability and reasonable cost. In Mission Critical Data Centers The compression busbar connection design is a prime reason why STARLINE has superior reliability and is the chosen electrical backbone for data centers and colocation sites throughout the world. Scalability allows the user to add additional STARLINE Busway sections and plug-in units as sites are filled up over time. In High-Tech Production & Assembly Work stations, scientific equipment, test equipment and computers are typically located throughout high-tech facilities, including electronics, circuit board manufacturers, aerospace, bio-medical facilities, clean rooms, and other high-tech industries. STARLINE puts the power where you need it, where a high-density of plug-in units and frequent reconfigurations are required. 7

Plug-In Monitoring Packages Current Monitoring Current monitoring can be provided for individual power drops or each busway run. Readout devices include audio alarm, visual alarm, meters and serial data transmission for remote location. Bus Shield TVSS Surge Suppressor STARLINE Busway systems can be protected from voltage surges with the Bus Shield TVSS unit. This TVSS unit is contained in a plug-in unit, and when it s turn-n-lock connected to the busway run near the power feed, it absorbs common surges that can occur, from sources such as equipment start-ups, lightning, and exterior interference. For details, consult factory. System Capacities (all shown as three-phase) System No. Amps Volts Neutral ISO GRD. Size B40 40 480 100% No 1.66" x 1.62" B50 50 480 100% No 1.66" x 1.62" B60C 60 480 100% No 1.66" x 1.62" B60 60 600 100% No 2.58" x 1.79" B100C 100 600 100% No 2.58" x 1.79" B100NG 100 600 200% Yes 4.19" x 2.38" B160 160 600 100% No 4.19" x 2.38" B225 225 600 100% No 4.19" x 2.38" B225G 225 300 100% Yes 4.19" x 2.38" Visit our Website at www.uecorp.com or call 800.245.6378, for the location of the nearest STARLINE Applications Engineer. 3089 Washington Pike Bridgeville, PA 15017 USA phone: 800-333-3490 or 412-221-4400 fax: 412-221-6828