INTELLIGENT MEDIUM POWERBAR impb

Similar documents
INTELLIGENT MEDIUM POWERBAR

HIGH POWERBAR COPPER UL857

CAST RESIN BAR IP68 BUSBAR SYSTEM

PDI PowerWave 2 Bus System

PowerWave Bus System. For More Information Use your QR Reader THE NEXT GENERATION OF FLEXIBLE POWER DISTRIBUTION

Flexible, Customizable Power Solutions for Mission Critical Success

Flexible, Customizable Power Solutions for Mission Critical Success

C1000 Series Automatic Cap Bank

Conduit and Wire. Wire and Cable Whips. Bus Duct, Cable Trays, Overhead or Under Floor Raceways, Strut or Channel Systems

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Power Break II Switchboard

Flexible, Customizable Power Solutions for Mission Critical Success

LSI 20 Series 30A, 120V Surface Busway Components 1

Put the Power in Your Hands

Busway Construction. Bus Bars

Electronic Circuit Breaker ESS20

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Product Selection Guide: T5 Series- 250, 400 & 800 Amps

POWERBUS 225 Busway and Plug-In Units

B BASIC HEAT TREATMENT CONSOLE

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

COMPACT BUSWAY 40 & 60 AMP HOUSING

IN2 Enclosed Switches and Circuit Breakers

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

General Specifications for Lighthouse Power Pedestal

ype UP T Busplugs Low Voltage Switchboard Equipment

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

PowerWave 2 TM Bus System

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Design Standard. Purpose: Design Standard:

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

A. Submit manufacturer's literature and technical data before starting work.

Lithium Power Cabinets

Pow-R-Flex low ampere busway

National Marine Manufacturers Association Product Compliance Specialist Examination D.C. Electrical (2013 MY) ABYC E-11 (08 Amended 09)

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Ultravar TM AUTOMATIC POWER FACTOR CORRECTION & HARMONIC SOLUTIONS

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Generator Fire Safety: Generator assemblies should be located outside the building.

Pretest Module 24 Three-phase Service Entrance

MINUTEMAN POWER TECHNOLOGIES Endeavor LCD Series Product Specifications 1000VA 3000VA Single-phase Uninterruptible Power Supply 1.

Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers

smissline Description

POWERFLOW. Your Idea System! Series. Series BUSWAY BUSBAR TRUNKING SYSTEM 630A 6300A ELECTRIC COMPAC ELECTRIC COMPAC ELECTRIC MAN. CO., LTD.

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

825-P Modular Protection System for motors Specification Guide

Solar Combiner Solutions

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

SURFACE TRACK (120/250V) SPECIFICATIONS

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Metal-enclosed medium-voltage power factor correction system

Motors Automation Energy Transmission & Distribution Coatings UBW. Molded-Case Circuit Breaker UL 489 Listed

Product Selection Guide

CUSTOMER / ACCOUNT INFORMATION Electric Utility Customer Information (As shown on utility bill)

3 - Protection components Motor circuit-breakers

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

A powerful way to manage your power distribution challenges. I Power Distribution Blocks

SECTION PANELBOARDS

.3 Section Waste Management and Disposal.

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Global Product Selection Guide

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

I power distribution. Blocks. challenges. Finger-Safe / FSPDB Series...I2. MPDB Open-Style PDBs... I4. MPDB62-MPDB63 (Mini) Open-Style PDBs...

WavePro LT Busway Cost effective solution for electrical distribution

Remote on/off switch Connector for remote on/off switch available on all models. DIP switch for 50/60Hz selection (48/350 model only)

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

MCCB Plug-in Chassis Type HBC

NS Feeder pillar up to 3200A

Photovoltaic Solar Plan Review

Product Selection Guide: T3 Series- 100 & 225 Amps

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

Underfloor to desk 231

Plug-In Raceway - Power

VASS Electrobar Busway Systems. Global Data Centre Showcase

Document Requirements for Engineering Review PV Systems v1.0 6/9/2017

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Short form catalogue. Motor protection & control

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Rapier AX Air Break Switch Disconnector. engineering brilliant solutions

SECTION MOTOR CONTROL

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

Pow-R-Line 3E Panelboard

Switches & Motor Controls

LIEBERT APM 3-PHASE UPS: 15-90KVA/KW, 60HZ, VAC, SINGLE & DUAL INPUT - SITE PLANNING DATA

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

Transcription:

INTELLIGENT MEDIUM POWERBAR impb

INTELLIGENT MEDIUM POWERBAR impb E+I Engineering s Intelligent Medium Powerbar (impb) is a 600 Volt encased track busduct. The range is available in two bar configurations from 160A to 800A. The bar is housed in an aluminum casing rated IP2X. Key features: Unique open channel system allows busplugs to be placed anywhere along the bar Solid joint pack construction Up to 12ft lengths Busplugs have mechanical/ electrical interlocks and secure to the bar with a ground first, break last safety feature. www.e-i-eng.com 1

TECHNICAL FEATURES impb is constructed from high density 99.99% conductivity copper. The conductors are insulated with a custom UL certified thermoplastic material with outstanding heat characteristics. The insulation has excellent dielectric strength and is impact resistant. impb is constructed with an aluminum housing providing a durable structure which also acts as a ground path. The impb range can be engineered with an over-rated neutral option for busduct systems with non-linear loads. The additional neutral capacity prevents overloading caused by zero sequence harmonic currents. E+I Engineering offer a 100% fully isolated ground for systems where ground isolation is required e.g. systems with heavy microprocessors, based loads or large computer based installations. Busbar Rating (Amps) Housing Size (inches) 4 Pole 5 Pole 160A 6.89 x 1.73 8.27 x 1.73 250A 6.89 x 1.73 8.27 x 1.73 400A 6.89 x 1.73 8.27 x 1.73 500A 7.09 x 2.05 8.46 x 2.05 600A 7.09 x 2.05 8.46 x 2.05 Phase Configurations Configuration Phases Neutral Ground TP/N 100% 100% Case TP/ON 100% 170% Case TP/NG 100% 100% 100% TP/ONG 100% 170% 100% Note: Case refers to the aluminum casing being used as a ground. 2 www.e-i-eng.com

INTELLIGENT MEDIUM POWERBAR impb LENGTHS AND JOINTS Distribution lengths Distribution lengths are designed as an open track system; busplugs can be plugged in anywhere along the bar. The opening is finger safe meeting a rating of IP2X. Straight lengths can be supplied at any length from 2ft - 12ft. Distribution Lengths The impb joint pack securely locks two feeder lengths together with a traditional busduct bolted joint. No special tooling is required and joints may be disassembled and reassembled easily. impb uses custom designed thermally and electrically secure joint packs. Temperature monitoring of joints is available as an option. Busway Joints End Feeds E+I Engineering provide standard cable end boxes with options for cable entry from various points. Center feeds and load bank feeds can also be supplied to meet specific project requirements. Cable End Feed www.e-i-eng.com 3

INSTALLATION The modular design of impb allows it to be easily installed either horizontally or vertically depending on specific project requirements. Hanger brackets are supplied per length. These can be easily attached to drop rods for a seamless installation process. impb can be connected directly to E+I Engineering s High Powerbar (HPB) to provide a full power solution. Typical Underfloor Arrangement Hot Aisle Cold Aisle Arrangement HPB to impb Connection 4 www.e-i-eng.com

INTELLIGENT MEDIUM POWERBAR impb www.e-i-eng.com 5

BUSPLUGS Busplugs impb busplugs are engineered with the safety of the installer and user as the key criteria. All busplugs have a ground first, break last safety feature and can be safely installed using Powerbar s SafeWork Technology. 1. The units interlock onto the busduct with a ground strip. This ensures that the ground is the first point of contact with the busduct system during installation. 2. The mechanical interlock secures the unit to the bar using high tensile strength lockable hardware which cannot be fitted incorrectly. 3. Once fitted to the bar, the engager handle can be turned. This lifts the contacts into the busduct and has a positive lock once fully rotated. Key features: - SafeWork Technology - Individual busplugs rated up to 125A - Interlock feature ensures polarities do not mismatch - Busplugs can be fitted with IEC 309 receptacles, NEMA receptacles or whip cords as required - Circuit breakers or fused disconnects are fitted to the busplug according to the installation requirements Tap off units 6 www.e-i-eng.com

INTELLIGENT MEDIUM POWERBAR impb METERING impb offers advanced metering which allows the user to monitor, integrate and display data center power information via RJ45 Ethernet plug-in connections. Final circuit monitoring is integrated into the busduct to measure the total load of the bar and busplugs. Power calculations of total input power for each busduct run can also be provided. Options: - Voltage for all three phases - Current - phase, ground and neutral - kw, KVa, kvar, power factor, kwh Daisy Chaining Meters Advanced options: - Voltage total harmonic distortion - Overvoltage/ undervoltage alarm threshold - Minimum and maximum current - Demand and percentage load current - Crest factor - Warning and alarm threshold It is also possible to monitor closed and trip status for each MCB. The status signals are fed back to the end feed using the integrated Ethernet cabling. The modules run in a daisy chain from meter to meter utilising the side channel in the housing for cabling. www.e-i-eng.com 7

TECHNICAL DATA Technical Data Rated Current (A) 160 250 400 500 600 Rated Operational Voltage (V) 600 600 600 600 600 Rated Insulation Voltage (V) 1000 1000 1000 1000 1000 Short Circuit Short Circuit Rating (KAIC) 50 50 50 65 65 Phase Conductor Cross Sectional Area (inches²) 0.1891 0.1891 0.3255 0.3952 0.4960 Neutral Conductor Cross Sectional Area (inches²) 0.1891 0.1891 0.3255 0.3952 0.4960 Isolated Ground Conductor 100% Ground Cross Sectional Area (inches²) 0.1891 0.1891 0.3255 0.3952 0.4960 Housing Ground Path Cross Sectional Area (inches²) 2.1886 2.1886 2.1886 3.1465 3.1465 Overall Dimensions Height x Width of 4 Pole System (inches) 6.89 x 1.73 6.89 x 1.73 6.89 x 1.73 7.09 x 2.05 7.09 x 2.05 Weight Weight of 4 Pole System (lbs/ft) 6.35 6.35 9.54 13.07 15.59 8 www.e-i-eng.com

INTELLIGENT MEDIUM POWERBAR impb www.e-i-eng.com 9

10 www.e-i-eng.com

E+I Engineering USA Corp USA Manufacturing Location 400 Supreme Industrial Drive Anderson South Carolina 29621 Tel: +1 864 375 1757 E+I Engineering Ltd. European Manufacturing Location Ballyderowen Burnfoot Co.Donegal Ireland Tel: (UK) +44 (0)28 71353030 (ROI) +353 (0)74 9368719 Powerbar Gulf LLC Middle East Manufacturing Location N16/N17 Al Ghail Industrial Park Ras Al Khaimah PO Box 13229 UAE Tel: +971 (0) 7221 6100 E+I Engineering Ltd. UK Central Office 2/8 Victoria Avenue London EC2M 4NS Tel: +44 (0)20 3206 1650 Email: info@e-i-eng.com WWW.E-I-ENG.COM