Butterfly Valve Type 58 (PDCPD)

Similar documents
Butterfly Valve Type 57P

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

Butterfly Valves ASAHI AV VALVES

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1

3-Way Ball Valve Type 23H

Diaphragm Valve Type 72

Diaphragm Valves Type 15

Butterfly_Valve_Type57P

Sediment strainer (Type Y)

Contents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Rotary Damper. Type 57: 40~350mm (1 1/2 ~14 ) Type 56: 400mm (16 ) Type 75: 450~600mm (18 ~24 ) Contents

Air Release Valve (PDCPD) Air Release Valve for Water (PDCPD + Epoxy Resin Coating) User s manual. Air Release Valve. Air Release Valve for Water

contents (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 User s Manual

Constant Flow Valves ASAHI AV VALVES H-V019-E-6. Contents. Serial No. User s Manual

Ball Valve Type 21 21α Nominal size mm (1/2-4 )

Diaphragm Valve Type 14 Pneumatic Actuated Type AV

Diaphragm Valve Type 14 Pneumatic Actuated Type AP. User s Manual. Contents H-A065-E. Serial No.

Rotary Damper Pneumatic Actuated Type TA

Rotary Damper Electric Actuated Type S

Butterfly Valves Pneumatic Actuated Type TA Type TW

3-Way Ball Valve Type23 Pneumatic Actuated Type TA

3-Way Ball Valve Type 23 Electric Actuated Type T

Ball Valve Type Pneumatic Actuated Type TA

Diaphragm Valve Type 16 (Pneumatic Model Type AD)

Diaphragm Valve True Union Diaphragm Valve Pneumatic Actuated Type AI

User s Manual. Compact Ball Valve Type27 Pneumatic Actuated Type AR mm (3/8-2 ) Contents. Installation, Operation and Maintenance Manual

3-Way Ball Valve Type23 Pneumatic Actuated Type AR. User s Manual. 15~50mm(1/2-2 ) Contents. Installation, Operation and Maintenance Manual

Pneumatic Actuated Type AA

Pneumatic Actuated Type AR. User s Manual. 15~50mm(1/2-2 ) Contents. Installation, Operation and Maintenance Manual

Pneumatic Actuated Type AR. User s Manual. 15~50mm(1/2-2 ) Contents. Installation, Operation and Maintenance Manual

Diaphragm Valve Type 14 Pneumatic Model Type AV

Diaphragm Valves Type 14 True Union Diaphragm Valves Type14

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Operating & Maintenance Manual For Steam Conditioning Valve

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

Danfoss Butterfly Valve

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

Butterfly valves Figure 56 Installation & Maintenance Instructions

OPERATION MANUAL. Diaphragm Pump. TD/TD2 Series TD-08, 15, 20/TD2-25. Introduction

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

KEYSTONE. Check valves Figure 85/86 Installation & Maintenance Instructions. Figure 85. Figure 86.

VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

MAINTENANCE MANUAL G15 Series

Keystone Figure 85/86 Check valves Installation and Maintenance Instructions

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

Installation, Operation, and Maintenance Manual

Installation and operating manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR INSTRUMENT ISOLATION VALVE

DeZURIK 24" THRU 36" RESILIENT BUTTERFLY VALVES

KEYSTONE. Butterfly valves Figure 9 Installation & Maintenance Instructions. Please read these instructions carefully

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Disassembly and Reassembly Manual

Doc. No. NDP 210M-04 MAINTENANCE MANUAL YAMADA AIR-OPERATED DIAPHRAGM PUMPS DP-10

TBV OPERATION AND MAINTENANCE MANUAL SERIES 1800: FLANGED BALL VALVE. For technical questions, please contact the following:

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Swing-Flex Check Valve

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

KEYSTONE Figure 990/991 Butterfly valves Installation, operation and maintenance instructions

Maintenance Manual for Brake of Geared Traction Machine

OPERATIONS MANUAL LEVER CHAIN HOIST

2" - 24" OS Series Butterfly Valves. Operation and Maintenance Manual. Job Name: Contractor: Date:

Series 2200/2220 Control Valve. Operation and Maintenance SCOPE OF MANUAL MAINTENANCE DESCRIPTION VALVE INSTALLATION

USER INSTRUCTIONS. Kämmer SmallFlow / / SP Low and Micro Flow Valves. Installation Operation Maintenance

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

Doc. No. NDP 033M-14 MAINTENANCE MANUAL YAMADA AIR-OPERATED DIAPHRAGM PUMPS. DP-5F series DP-10F series DP-20F series DP-25F series DP-38F series

NYL Resilient Seated Butterfly Valves Operation and Maintenance Instructions

Installation, Operation, and Maintenance Manual

Read and understand this manual for safely usage.

CHASSIS CONTENTS EXTERIOR PARTS 6-1 FRAME COVER 6-2 REAR FRAME COVER 6-4 FRONT WHEEL 6-6 FRONT BRAKE 6-10 HANDLEBARS 6-17 FRONT FORK 6-19

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES

Val-Matic 4-20 Air/Vacuum Valve

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

Crispin Valves Operating Guide. Crispin

Installation, Operation, and Maintenance Manual

MODCO TM FIGURE 500 CLOSURE

PNEUMATIC SLIDING VALVE

INSTRUCTION MANUAL. for BUTTERFLY VALVES

Operation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves

DOUBLE OFFSET BUTTERFLY VALVE

Surplussing Valve SP-COSR-16

Instructions. for Installation, Operation and Maintenance of ABO Butterfly Valves, Series 600 and 900

[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No:

Doc. No. NDP 173M-05 MAINTENANCE MANUAL YAMADA AIR-OPERATED DIAPHRAGM PUMPS. DP-15 series

DeZURIK 2 20" BOS BUTTERFLY VALVES

MUELLER GAS. Shur StopTM Unit 812 PE Line Stopping. System 8" 12" SDR Reliable Connections. General Information 2

TRITEC (TT2) Instruction Manual

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

3M TM Filter Housing 1BS-T/1BS-TW Series

Transcription:

Serial No. H-V074-E Butterfly Valve Type 58 (PDCPD) 700mm (28 ) User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation, unpacking and storage 3 (4) Name of parts 4 (5) Working pressure and temperature 5 (6) Installation procedure 6 (7) Support setting procedure 10 (8) Operating procedure 11 (9) General instructions for fluid flowing 11 (10) Inspection items 11 (11) Troubleshooting 12 (12) Handling of residual and waste materials 12 Butterfly Valve Type 58 700mm (28 )

This user s guide contains information important to the proper installation, maintenance and safe use of an ASAHI AV Product. Please store this manual in an easily accessible location. <Warning & Caution Signs> Warning Caution <Prohibited & Mandatory Action Signs> This symbol reminds the user to take caution due to the potential for serious injury or death. This symbol reminds the user to take caution due to the potential for damage to the valve if used in such a manner. Prohibited: When operating the valve, this symbol indicates an action that should not be taken. Mandatory action: When operating the valve, this symbol indicates mandatory actions that must be adhered to. (1) Be sure to read the following warranty clauses of our product - Always observe the specifications of and the precautions and instructions on using our product. - We always strive to improve product quality and reliability, but cannot guarantee perfection. Therefore, should you intend to use this product with any equipment or machinery that may pose the risk of serious or even fatal injury, or property damage, ensure an appropriate safety design or take other measures with sufficient consideration given to possible problems. We shall assume no responsibility for any inconvenience stemming from any action on your part without our written consent in the form of specifications or other documented approval. - The related technical documents, operation manuals, and other documentation prescribe precautions on selecting, constructing, installing, operating, maintaining, and servicing our products. For details, consult with our nearest distributor or agent. - Our product warranty extends for one and a half years after the product is shipped from our factory or one year after the product is installed, whichever comes first. Any product abnormality that occurs during the warranty period or which is reported to us will be investigated immediately to identify its cause. Should our product be deemed defective, we shall assume the responsibility to repair or replace it free of charge. - Any repair or replacement needed after the warranty period ends shall be charged to the customer. - The warranty does not cover the following cases: (1) Using our product under any condition not covered by our defined scope of warranty. (2) Failure to observe our defined precautions or instructions regarding the construction, installation, handling, maintenance, or servicing of our product. (3) Any inconvenience caused by any product other than ours. (4) Remodeling or otherwise modifying our product by anyone other than us. (5) Using any part of our product for anything other than the intended use of the product. (6) Any abnormality that occurs due to a natural disaster, accident, or other incident not stemming from something inside our product. Butterfly Valve Type 58 700mm (28 ) 1

(2) General operating instructions Warning Caution - Using a positive-pressure gas with our plastic piping may pose a dangerous condition due to the repellent force particular to compressible fluids even when the gas is under similar pressures used for liquids. Therefore, be sure to take the necessary safety precautions such as covering the piping with protective material. For inquiries, please contact us. For conducting a leak test on newly installed piping, be sure to check for leaks under water pressure. If absolutely necessary to use a gas in testing, please consult your nearest service station beforehand. - Do not step on or apply excessive weight on valve. (It can be damaged.) - Do not use the valve in conditions where the fluid may have crystallized. (The valve will not operate properly.) - Keep the valve away from excessive heat or fire. (It can be damaged, or destroyed.) - Always operate the valve within the pressure vs. temperature range. (The valve can be damaged or deformed by operating beyond the allowable range.) - Allow sufficient space for maintenance and inspection. - Select a valve material that is compatible with the media. For chemical resistance information, refer to CHEMICAL RESISTANCE ON ASAHI AV VALVE. (Some chemicals may damage incompatible valve materials.) - Keep the valve out of direct sunlight, water and dust. Use cover to shield the valve. (The valve will not operate properly.) - Perform periodic maintenance. (Leakage may develop due to temperature changes or periods of prolonged storage, rest, or operation.) Butterfly Valve Type 58 700mm (28 ) 2

(3) General instructions for transportation, unpacking and storage Installation,Operation and Maintenance Manual - When suspending and supporting a valve, take care and do not stand under a suspended valve. Warning Caution - This valve is not designed to handle impacts of any kind. Avoid throwing or dropping the valve. - Avoid scratching the valve with any sharp object. - Do not over-stack cardboard shipping boxes. Excessively stacked packages may collapse. - Avoid contact with any coal tar creosote, insecticides, vermicides or paint. (These chemicals may cause damage to the valve.) - When transporting a valve, do not carry it by the handle. - Store products in their corrugated cardboard boxes. Avoid exposing products to direct sunlight, and store them indoors (at room temperature). Also avoid storing products in areas with excessive temperatures. (Corrugated cardboard packages become weaker as they become wet with water or other liquid. Take care in storage and handling.) - After unpacking the products, check that they are defect-free and meet the specifications. - Once you have taken the product out of its packaging or crate, clean the inside of the valve with a clean piece of cloth. Butterfly Valve Type 58 700mm (28 ) 3

(4) Name of parts Nominal size: 700mm (28 ) No. DESCRIPTION No. DESCRIPTION No. DESCRIPTION [1] Body [7] Stem (A) [15] Screw [1a] Inserted Metal of Body [8] Bush [16] Key [2] Disc [9] O-Ring (C) [17] Gear Box [2a] Inserted Metal of Disc [10] Stem Holder (B) [18] Gasket [3] Seat [11] Washer (A) [19] Washer (B) [4] O-Ring (A) [12] Bolt (A) [20] Nut [5] O-Ring (B) [13] C -Type Retaining Ring [21] Bolt (B) [6] Stem (B) [14] Stem Holder (A) [22] Cap Butterfly Valve Type 58 700mm (28 ) 4

(5) Working pressure and temperature Nominal size: 700mm (28 ) Butterfly Valve Type 58 700mm (28 ) 5

(6) Installation procedure Warning Caution - When suspending and supporting a valve, take care and do not stand under a suspended valve. - Be sure to conduct a safety check on all hand and power tools to be used before beginning work. - Wear protective gloves and safety goggles as fluid remain in the valve even if the pipeline is empty. (You may be injured.) - When installing a pipe support by means of a U-band or something similar, take care not to over-tighten. (Excessive force may damage the pipe.) - Do not install the valve with the disc fully closed. (The disc may pinch into the seat, resulting in a high operating torque and preventing the valve from operating properly.) - When installing pipes and valves, ensure that they are not subjected to tension, compression, bending, impact, or other excessive stress. - Use flat faced flanges for connection to AV Valves. - Ensure that the mating flanges are of the same standards. - The gasket is unnecessary. (The seat carries out the role of the gasket.) - The valve disc is in the position indicated by solid Fig. 6-1 lines in figure to the right prior to shipment from the factory. If the valve is opened or closed after unpacking, it must be reset in this position before installation. Failure to do so will result in damage to the surface of the valve seat during handling and installation. - Care must be used during piping installation to ensure that the pipes or flanges are properly aligned so that the valve disc does not contact them in any setting. Misalignment as in figure below will result in damage to the valve. Fig. 6-2 INTERFERENCE OF THE DISK Butterfly Valve Type 58 700mm (28 ) 6

In case of an abutting thick walled flange and pipe, shave the flange or the pipe inner diameter in order to avoid contact of pipe and disc. If the inside diameter of the connecting pipe is larger than dimension D below, shaving is not necessary. Nominal Size Diameter D mm (inch) mm (inch) 700 (28 ) 661 (26.02 ) 1) Set the short pipes. Set the short pipes with suitable stands so that the center of the valve in the upright position aligns with that of the short pipe. Using a cloth, wipe foreign matter away from the flange surfaces of the short pipes. Fig.1 2) Stand the valve upright. Wind the nylon sling around the head part of the body and gradually raise it up. After standing the valve upright, wipe foreign matter away from the seat with a cloth. Warning - Support the valve up by looping a belt around the gearbox like Fig 2. The eyebolt in the gearbox is designed to support the weight of gearbox, so avoid lifting up the whole valve with the eyebolt. Use it just as a support to stand the valve upright. Fig.2 Nylon sling Butterfly Valve Type 58 700mm (28 ) 7

3) Lower the valve gradually between the short pipes onto the spacer. Lower the valve carefully without damaging the flange surfaces of short pipes The required face to face dimension of each valve size is shown below. Make sure that the valve is slightly closed. Fig.3 Nominal Size Face-to-face Dimension mm (inch) mm (inch) 700 (28 ) 169 (6.65 ) 4) Connect the valve loosely to one of the short pipes. Match the bolt hole of the short pipe with that of the valve, and put four stud bolts into the inserted metal parts (part 1a), then tighten nuts lightly by hand. Fig.4 5) Set the second short pipe with the valve. Using the nylon sling, loop the short pipe and tighten nuts using the same procedure as step 4). Fig.5 6) Put the bolts through the full bolt holes and plumb in. Move the pipe gradually to match holes one another, and set nuts. *Tighten the bolt-nuts of the valve and the flange in the full bolt holes at first, and then tighten the bolt-nuts on the inserted metal parts. Fig.6 Butterfly Valve Type 58 700mm (28 ) 8

7) Tighten up the nuts according the tightening torque values listed below Tighten the nuts in a diagonal manner. All penetrated bolts should be tightened first, and the inserted metal parts should be tightened after. Fig.7 Nom. Size Bolt tightening torque mm (inch) N m (kgf cm) 700 (28 ) 130 (1,330) 8) Using the nylon sling, lift up around the flange sides of both short pipes to set in the required position. Hook a wire through the eyebolt in order to stabilize the valve. JIS Standard (10K) Unit: mm (inch) Nominal Size Bolt A Bolt B Quantity mm (inch) d L S d1 L1 Bolt A Bolt B Nut Washer 700 (28 ) M30 320 (12.60 ) 66 (2.60 ) M30 105 (4.33 ) 20 8 48 48 Notes ; The above figures are bolt size in the case of using the JIS B 2220 "Steel pipe flanges" nominal pressure 10K. Bolt A Bolt B Butterfly Valve Type 58 700mm (28 ) 9

(7) Support setting procedure Necessary items Spanner wrench U-type clamp (with bolt) Rubber sheet - Do not subject valve pump vibrations. (The valve may be damaged.) Caution - Set the valve support. (The valve may be damaged because the actuator is heavy.) Horizontal installation Set the stand under the valve. Spread the rubber sheet on the pipe and secure pipe with U-type clamp. Vertical installation Spread the rubber sheet under the gearbox, and fix it with the stand. Spread the rubber sheet on the pipe and secure pipe with U-type clamp. Butterfly Valve Type 58 700mm (28 ) 10

(8) Operating procedure - Do not use the valve to fluid containing slurry. (The valve will not operate properly.) Caution - The installed valve must never be opened or closed when foreign matter such as sand is present in the pipeline. - Do not exert excessive force in closing the valve. - When operating the handle, be sure to do so with your hand. (Using a tool may damage the handle.) Turn the handle gently to open or close. Check the travel indicator on the top of the gearbox, and turn the handle. Right turn (Clockwise) Shut direction Left turn (Counter clockwise) Open direction Nominal Size mm (inch) Number of hand wheel rotation 700 (28 ) 55 (9) General instructions for fluid flowing 1) Make sure that any foreign matter is not in the pipe, which may damage the valve seat before fluid flowing. Open the valve fully when the fluid starts flowing. 2) Although the sealing adjustment of disc is already adjusted, if the valve leaks during operation, loosen the stopper bolt in the actuator and find the volume of tightening. (10) Inspection items Caution - Perform periodic maintenance. (Leakage may develop due to temperature changes or over periods of prolonged storage, rest or operation.) Inspect the follow items; (1) Check for any flaw, crack, or deformation on the outside. (2) Check whether fluid leaks to the outside. (3) Check whether there are protrusions or retirement of seat. (4) Check the smoothness of handle operation. Butterfly Valve Type 58 700mm (28 ) 11

(11) Troubleshooting Problem Cause Treatment The valve does not operate smoothly. The protrusion of the seat. The uneven or excessive tightening of the bolt. The stopper is not adjusted properly. Loosen the bolt and adjust. Adjuster the stopper. Fluid is not stopped in the full closed position. The seat is damaged or worn. Foreign matter is in the valve. The disc is damaged or worn. The connecting bolts are too much tightened or tightened unevenly. Replace the seat. Disassemble the valve and clean. Replace the disc. Reset the valve. Fluid leaks to the outside. The seat is damaged or worn. Replace the seat. The handle does not work smoothly. The valve does not operate. Foreign matter is adhered. The gearbox is damaged. The connecting bolts are too much tightened. The gearbox is damaged. The stem is damaged. Reset the valve. Replace the gearbox. Reset the valve. Repair or replace. Replace the stem. (12) Handling of residual and waste materials Warning - Make sure to consult a waste treatment dealer for recommendations on the proper disposal of plastic valves. (Poisonous gas is generated when the valve is burned improperly.) Butterfly Valve Type 58 700mm (28 ) 12

Butterfly Valve Type 58 700mm (28 ) Distributor http://www.asahi-yukizai.co.jp/en/ Information in this manual is subject to change without notice. 2016.8 PDCPD Butterfly Valves 700-1200mm (28-48 )