PEDCAP-R-2, R-3 & R-4S/4L-INT

Similar documents
FOSC-100 B/H FOSC-100 B2/H

FOSC-400A4 INSTALLATION INSTRUCTION

Fiber optic splice closure

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

BUDI-S-SP. Building distributor. Introduction. Seals. Kit content. Accessories. TC-957-IP Rev A, Feb Wrap around cable seals

WRSS Wraparound Repair Sleeve Installation Instructions

HVS S 15kV Class

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

Heat Shrink closure Non - Pressurized & Pressurized RTSM Dome Closure RLSS RPBS Vault Closure Lead Sleeve Mechanical Closure Pillar Dp Jointing Kit

Product Installation Instructions. Raychem Corporation Electrical Products 8000 Purfoy Road Fuquay-Varina, NC 27526

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

3 Reenterable Encapsulated PST Dome Closure

WORLDWIDE GUARDWIRE ACCESSORIES INSTALLATION MANUAL PROVEN PERIMETER PROTECTION

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

Universal Splice Tray Installation Instructions

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

3M Cold Shrink QT-III Silicone Rubber Termination

INSTALLATION INSTRUCTION PEM1121ENG ENGLISH

Installation Instruction EPP /92

Installation Instruction Heatshrink Termination For 3 Core Polymeric Cables 7.2kV to 36kV

OPTICAL FIBER CLOSURE

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

Product Number

GENUINE PARTS INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS

Cold Shrink QS T Trifurcating Transition Splice Kit

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

SYSTIMAX 360 FTP Evolve Panel Instructions

Power Connection Kit installation instructions

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

8-Position Cat5E EMT Shielded Slim-Line Modular Plug

SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit

Assembly Instruction EL OCHITO WHITE CONTACTS 1000BASE-T/10GBASE-T TYPE I: PIN /SKT CABLE: S/FTP

I nstallation I nstruction Heatshrink Term ination For 3 Core Polym eric Cables 7.2 kv to 3 6 kv

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

ET-PWR-END-KIT Installation Instructions (part #JSR00)

PSI Anti-Corrosion Tape

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)

Connection kits for joining all types of DEVI self-limiting heating cables to cold tails

Rostra Electronic Cruise Control Install On a Stratoliner or Roadliner

RS 413 SUPPLEMENTAL RESTRAINT SYSTEM CURTAIN SHIELD AIRBAG ASSEMBLY REMOVAL

INSTALLATION INSTRUCTION

Installation Instruction EPP /02. Terminations for Screened Single Core Polymeric Insulated Cables up to 24 kv without Armour

TOYOTA RAV TRAILER WIRE HARNESS Section I Installation Preparation

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

Fiber Connector Shelf (CCS)

EXTERNAL UNDERGROUND EQUIPMENT

3M Mechanical Shearbolt Connectors, QCI Series

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS)

Dash Wiring, Power Module, and Crossmember Installation Instructions

GENUINE PARTS INSTALLATION INSTRUCTIONS

LEXUS GS 350/450h ILLUMINATED DOOR SILLS Preparation

Printer-friendly format 3M Scotchlok Electrical Spring Connectors Y- BOX 5-8#22, 4-6#20, 2-5#18, 2-3#16 AWG, 100 per box, Yellow. Learn More...

B Polyethylene Tape. B Splicing Covering. Holster

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

Please read thoroughly before starting installation and check that kit contents are complete.

FRONT SEAT AIRBAG ASSY RH

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

Installation Instructions K656CY, K656CH and K656I Deadbreak Receptacles

RAV4 TNS310 (Traffic) Plus

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

600/1000V, PVC Insulated Cables according to IEC

Assembly Instruction. EL OCHITO BLUE CONTACTS SuperSpeed USB TYPE I: PIN /SKT CABLE:

Corrosion Protection and Sealing

3M Cold Shrink Splice Kit QS-III 5536A

Heat-Shrinkable Tubing

HANDLING OF ASSEMBLY... 1 RRH END OF ASSEMBLY... 1 BASE STATION END OF ASSEMBLY... 7 POWER CODING REVISION HISTORY... 11

12-Inch Hybrid Fiber Access Terminal Installation Instructions

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999

Heat-Shrinkable Tubing

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

GENUINE PARTS INSTALLATION INSTRUCTIONS

OLDSMOBILE CUTLASS

TOYOTA im INTERIOR LIGHT KIT Preparation

DISPOSAL OF STEERING WHEEL PAD (WITH AIRBAG)

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

C Power Connection Kit

Hot Air Devices for welding, heating, shaping of thermoplastic materials. Floor welding machine Nozzles Accessories

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

GENUINE PARTS INSTALLATION INSTRUCTIONS

INTELLIQUILTER INSTALLATION ON APQS MILLENNIUM/FREEDOM SR ON BLISS-READY TABLE VERSION

DISPOSAL HINT: CAUTION: Never dispose of the horn button assy that has an undeployed

INSTALLATION INSTRUCTION PEM1093ENG ENGLISH

Signal Mirror Installation Instructions

3M Electrical Markets Division. Rubber, Mastic and Specialty Tapes Application Guide. Choose the. Right Tape. for your. Electrical Project

Manual UB20 / UB40 / UB50 / 2 EL WiMo Antennen und Elektronik GmbH

Transcription:

PEDCAP-R-2, R-3 & R-4S/4L-INT INSTALLATION INSTRUCTION TC-061-IP Rev A, Apr 2017 www.commscope.com Joint closure system for telecommunication distribution networks Kit contents PEDCAP-R-2 PEDCAP-R-3 PEDCAP-R-4S/4L 1 PEDCAP sleeve with integrated MVT layer 2 SCOP-200 1 Abrasive strip 1 Aluminium cable foil 1 Cleaning tissue 1 Tie-wrap 1 Installation instruction 1 Dessicant (Silicagel) 1 PEDCAP Sleeve 1 PEDCAP Sleeve 1 MVT Aluminium bag 1 MVT Aluminium bag 3 SCOP-200 4 SCOP-200 2 Abrasive strips 2 Abrasive strips 1 Aluminium cable foil 1 Aluminium cable foil 2 Cleaning tissues 2 Cleaning tissues 2 Tie-wraps 2 Tie-wraps 1 Installation instruction 1 Installation instruction 1 Dessicant (Silicagel) 1 Dessicant (Silicagel) Safety rules - Check manhole for the presence of gas and follow prescribed precautions. - When working with open flame, use standard safety equipment such as gloves, safety glasses etc.... as required. Jointing information Specification A closure approved for use on underground/aerial distribution cables. SCOP-200 must be fitted to each cable. SCOP-200 is also available separately. Packaging:500 pcs/box. For small cables up to 8 mm use SCOP-100. Recommended torches Propane torch e.g. torch FH-T001-0005 nozzle: FH-T001-0020 torch FH-1630-PIE nozzle: FH-1630-PIE-BN28 Description Joint length Joint bundle Max. number max. max. diam. of cables PED-CAP-R-2-INT 200mm 50mm 3 PED-CAP-R-3-INT 120mm 57mm 4 PED-CAP-R-4S-INT 250mm 84mm 4 PED-CAP-R-4L-INT 350mm 84mm 6 Sizing information Description Max. cable Min. cable Max. looped bundle diam.without SCOP bundle diam. without SCOP cable diam. PED-CAP-R-2-INT 30mm 16mm 2 X 18 PED-CAP-R-3-INT 40mm 11mm 2 X 23 PED-CAP-R-4S-INT 60mm 25mm 2 X 28 PED-CAP-R-4L-INT 60mm 25mm 2 X 28 Installation procedure 1 Remove cable sheath(s) to a maximum dimension as described in the jointing information. 2 Where applicable, install screen continuity (not included in the kit). 3 Make the joint according to approved practice. 4 Arrange completed joint in such a way that the bundle length and bundle diameter fit into the corresponding PEDCAP size.

5 Protect the splice with local approved tape. 6 Using the kitted cleaning tissues, clean the cables for a distance of about 300 mm starting from the cable sheath cut. 7 Using the kitted abrasive strip, abrade the cables circumferentially over a distance of about 150 mm for PEDCAP-R-3 and 250 mm for PEDCAP-R-2 and PEDCAP-R-4S/4L, from the sheath cut. 8 For PEDCAP-R-3 and PEDCAP-R-4S/4L temporarily position the aluminium bag over the joint to protect joint and conductors from damage (flame protection). Do not tape. Flame brush the abraded area of each cable for 10 seconds. 9 Position the PEDCAP completely over the joint. Mark the cables at the bottom of the PEDCAP and remove the PEDCAP and aluminium bag. 10 Place a second mark on the cables 30mm below the first mark (for PEDCAP-R-3, R-4S and R-4L only). 11 Install one SCOP on EACH cable, positioning them between the LOWEST mark and the completed joint. Apply SCOP tightly around each cable in the direction as shown on the backing paper, not more than two layers. Note: for cables with diameter less then 8mm: the SCOP-200 may be cut longitudinally in halves following the cable drawing on the backing paper. Apply one half to each small cable in the direction as shown on the backing paper. 12 Apply one layer of aluminium cable foil around each cable. Start at the 3rd SCOP slot from the end, away from the completed joint, in the direction of the cables. Smooth the foils with a blunt tool. 13 Tiewrap the two main cables together. It is important that they touch each other. 2

14 Position the cables following the drawing: 1 + 2 Main cables 3,4,5 and 6 Branch cables (See max. number of cables in the table page 1). 15 For PEDCAP-R-3 and R-4S/4L form the cables into a tight bundle (secure the silicagel to the joint). Slide the aluminium bag completely over it and secure with PVC or heat resistant tape. Do not tape more than 20 mm, or the second slot, onto the SCOP. Notes for heating Regulate flame to a total length of about 200 mm with a yellow tip of about 100mm. Important: During shrinking, move the flame continuously to avoid local overheating and damage. 16 Install the PEDCAP over the joint and start shrinking the PEDCAP from where the Thermo-indicating (TI) paint is applied on the body and move towards the end of the closure, converting all TI paint to black. 17 Continue heating with a soft flame until the adhesive flows at the end of the PEDCAP and between ALL the cables. Quality installation checks * All TI paint has been converted to black. * Adhesive flows around the circumference of the recovered PEDCAP end and in all gaps between the cables. * Each cable has been fitted with a SCOP. * All SCOPs should be covered by aluminum cable foil at the protruding ends of the PEDCAP. 18 Leave the closure undisturbed for a minimum of 30 minutes. 3

Re-entry & reclosing procedure A Re-entry Safety rules - Check manhole for the presence of gas and follow prescribed precautions. - When working with open flame, use standard safety equipment such as gloves, safety glasses etc. as required. 1 Make a ring cut with a hacksaw at the top of the transition area, without damaging the installed joint and conductors. Remove the dome of the PEDCAP. 2 Heat the recovered sleeve area. Make a longitudinal cut in the pre-heated sleeve area without damaging cables or joint. 3 Remove the pre-heated sleeve with a pair of pliers. Note: when removing a PEDCAP-R-4S/4L, if present, remove any inner cardboard liner. Apply additional heat to facilitate removal if required. Remove the taped aluminium bag completely. Note: it is not required to remove SCOP or adhesive from the cables. Protect all cooled adhesive with local approved tape. B Reclosing Safety rules - Check manhole for the presence of gas and follow prescribed precautions. - When working with open flame, use standard safety equipment such as gloves, safety glasses etc. as required. Important - If no cable is added, proceed with step 15-18. - In case an augment is required, the following installation steps apply ONLY TO THE ADDED CABLE. 1 Remake the joint according to approved practices. 2 Arrange the completed joint in such a way that bundle length and bundle diameter fit into the corresonding PEDCAP size. 3 Protect the splice with local approved tape. 4

4 Clean the added cable, using the kitted cleaning tissues. Using the kitted abrasive strip, abrade the added cable in the area of the SCOP (installed on the other cables). Remove temporarily installed local approved tape from existing SCOP. 5 Temporarily position the Aluminium bag over the joint to protect joint and conductors from damage (flame protection). Do not tape. Flame brush the abraded area of each added cable for 10 seconds. 6 Install SCOP at the same position as existing SCOP on the other cables. 7 Apply one layer of aluminium cable foil around the ADDED cable. Start at 30 mm, or the 3rd SCOP slot from the end, away from the completed joint, in the direction of the cables. Smooth the foil with a blunt tool. 8 Remove the tie-wrap from the cable bundle. 9 Apply a new aluminium cable foil over the existing cable bundle. 10 Position the cables following the drawing: 1 + 2 Main cables 3,4,5 and 6 Branch cables (See max. number of cables in the table page 1). 11 For PEDCAP-R-3 and PEDCAP-R-4S/4L form the cables into a tight bundle (secure the silicagel to the joint). Slide the aluminium bag completely over it and secure with PVC or heat resistant tape. Do not tape more than 20 mm, or the second slot, onto the SCOP. 12 Continue the installation as described in the initial instruction: step 16 through 18. 5

Quality installation checks * All TI paint has been converted to black. * Adhesive flows around the circumference of the recovered PEDCAP end and in all gaps between the cables. * Each cable has been fitted with a SCOP. * All SCOPs should be covered by aluminum cable foil at the protruding ends of the PEDCAP. To find out more about CommScope products, visit us on the web at www.commscope.com For technical assistance, customer service, or to report any missing/damaged parts, visit us at: http://www.commscope.com/supportcenter 2017 CommScope, Inc. All rights reserved. PEDCAP and all trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. This product is covered by one or more U.S. patents or their foreign equivalents. For patents, see: www.commscope.com/productpatent/productpatent.aspx.