Solenoid Valve DF-SB-series

Similar documents
Solenoid Valve DF-SA-series

Solenoid Valve ST-SA-series

Solenoid Valve ST-IA-series

Center Center Exhaust Pressurized PS-32AS PS-32BS PS-32AD PS-32BD PS-520S PS-520D PS-53CD PS-53ED PS-53PD. Series PS. Function

Type 6213 EV, 6281 EV

Solenoid valves VZWM-L, NPT

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Servo-operated 2/2-way solenoid valves Type EV220A

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

3/2-way Solenoid Valve, direct-acting, NC or NO

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

2/2-way Solenoid Valve for liquids and gases

Solenoid valves VZWM-L

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Solenoid valves VZWM-L

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

2/2-way Solenoid Valve with servo diaphragm

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Technical Principles of Valves

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

Solenoid valve Types EV220B 15 - EV220B 50

Solenoid valves 2/2-way servo operated type EV220B 15 50

Assisted lift operated 2/2-way solenoid valves Type EV250B

Solenoid valve Types EV220B 15 - EV220B 50

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

2/2-way assisted lift operated solenoid valve type EV250B

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

Direct-acting 2/2-way plunger valve

how to use solenoid valves INDUSTRIAL CONTROLS DKACV.PS.600.A3.02 / 520B1389

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210B. February 2002 DKACV.PD.200.A B1504

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Nessie 2/2 way Solenoid valves for High Pressures and High Temperatures, type VDHT

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Solenoid Valves. Product Information. It s all at Albion

3/2-way Solenoid Valve for pneumatics

GEMÜ 205 Electrically operated solenoid valve

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

OPD min max a c max d c. code [ISO 228 G] [mm] [l/min] [barg] [barg] [barg] code [Volts/Hz]

2/2- and 3/2-way solenoid valve for aggressive fluids

Remote Process Actuation Control System AirLINE - Siemens ET 200S

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

Direct-acting 3/2 way plunger valve

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

Direct-acting 2/2- or 3/2-way pivoted armature valve

2/2-way and 3/2-way Normally Closed (NC) and Normally Open (NO)

SOLENOID VALVES 1. GENERAL PURPOSE VALVES ACCESSORIES ORDER CODIFICATION : TEC22 DIRECT ACTING INDIRECT ACTING

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

2/2 or 3/2 way direct acting rocker solenoid valve

Type Modular Water Valve System servo-assisted; variable and extendable. 2/2 way; DN mm; 1 up to 7 bar Advantages / Benefits

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

PF6 Stainless Steel Piston Actuated On/Off Valves

Angle seat valve with piston actuator VZXA-...-K

Solenoid valves 2/2-way servo-operated Type EV220B 15-50

Mounting and Operating Instructions EB 5868/5869 EN

Solenoid System FLANGE MOUNTING VERSION

Solenoid valve VDHT standard BSP (British Standard Pipe)

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Solenoid valves VZWP, servo-controlled

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Angle seat valve with diaphragm actuator VZXA-...-M

PF6 Stainless Steel Piston Actuated On/ Off Valves

Type EV224B. Servo-operated 2/2-way solenoid valves for high pressure air. Data sheet

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Technical Data Sheet

Servo-operated 2/2-way solenoid valves for high pressure

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Type /2-way globe valve 2/2-Wege-Geradsitzventil Vanne à siège droit 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Angle seat valve with piston actuator VZXA-...-K

Common wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

MINIATURE SOLENOID GENERAL SERVICE VALVES

Solenoid valves, 2/2-way servo-operated type EV220B 6-22

NIFW % # ) Air and Inert Gas Non-Incendive Field Wiring Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Differential pressure sensor

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics

2/2 Pressure operated valves

16mm miniature rocker solenoid valve with isolating diaphragm for special applications

SG-B1 SERIES / SG-A1 SERIES

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Transcription:

2/2-WAY SEMI-DIRECT OPERATED NORMALLY OPEN Solenoid Valve DF-SB-series The DF-DB is a semi-direct operated 2/2-way solenoid valve. The valve is normally open. The solenoid valves have an orifice of 16 to 25 mm, operate from 0 bar and are suitable for medium flow rates. The body is made of brass or stainless steel with NBR, EPDM or FKM seal. The DF-SB solenoid valves are compatible with all coils from the CS2-series. Example of product code Series Function Operation Position Body Seal & Media Temperature Direct Flow (DF) 2/2 way Semi-direct (S) Normally open (B) Brass (B) / Stainless steel (S) NBR (N) -10..80 C EPDM (E) -30..120 C FKM (F) -10..120 C Semi-direct Operation 3/4" Pipe DN 20mm Orifice DF S B 034 B 200 F - 230AC Series Position Body Seal Direct Flow Normally Open Brass FKM Dimensions 230V AC Voltage Ambient Temperature Max 50 C Min. Pressure Difference Max. Pressure Coil series Voltage Insulation Class 0 bar 5/3 bar (AC/DC) CS2 380V AC 50Hz (380AC) 230V AC 50/60Hz (230AC) 120V AC 60Hz (120AC) 24V DC (024DC) 24V AC 50/60Hz (024AC) 12V DC (012DC) Class F Power Duty Cycle 22 W / 33VA 100% ED Connector EN 175301-803 (formerly DIN 43650A) Protection Class Circuit Diagram IP 65 (with cable plug) 2 1 2 1 Pipe (P) Orifice (D) Kv (m3/h) AxBxH (mm) Response time (Open/Close) 3/8" (038) 16 mm (160) 4.09 69x57x135 80/300 ms 1/2" (012) 16 mm (160) 4.09 69x57x135 80/300 ms 3/4" (034) 20 mm (200) 6.48 73x57x142 90/550 ms 1" (100) 25 mm (250) 10.24 99x77x150 100/800 ms MANUAL-DF-SB-EN v1.2 www.jpfluidcontrol.com 1

Flow rate water (l/min) JP FLUID CONTROL 1. TECHNICAL SPECIFICATIONS 1.1. Principle of operation A solenoid valve is a valve for neutral, clean liquids and gases, which is electrically controlled with the aid of a solenoid. 2/2 way means that the valve has two ports (input / output) and two positions (closed / open). The valve is normally open. This means the valve is closed when energized. Semi-direct operated solenoid valves combine the properties of both direct and indirect operated solenoid valves. The force that is required to open and close the diaphragm is supplied by both the solenoid plunger as well as the pressure of the medium. This allows them to work from zero bar pressure differential. Furthermore, they can control a high flow rate with a relatively small solenoid core. They can be used in only one flow direction. This type of solenoid valves is used in systems that require a reasonable flow rate, but the pressure difference between input and output is low or unknown. Semi-direct operated solenoid valves open slower than direct operated solenoid valves, but they are suitable for higher flow rates. 1.2. Area of application Body material The DF-SB series is made with a brass or stainless steel body material. Depending on the application, the right material should be selected. View 1.7 for the material specification of each component. Diaphragm Temperature Allowed media FKM -10 C.120 C Most fuels and oils, cold water, detergents, compressed air. EPDM -30 C.120 C Water and steam, alcohol. NBR -10 C.80 C Neutral media, like air, cold water, hydraulic oil. 1.3. Flow chart Not allowed Glycol-based brake fluids, ammonia gas, hot water and steam, low molecular weight organic acids (such as acetic acid). Oils, fats, fuels, solvents. Fuels, strong acids, brake fluid. In the flow chart, the flow of water from 20 C is shown as a function of the positive pressure difference across the valve. The flow rate is expressed in liters per minute and the pressure in bar. The graph shows different pipe diameters. 1000 Body material Allowed media Brass (ASTM #37800) Neutral and non-corrosive media. Stainless Steel (SS316) Suitable for aggressive media and corrosive media like seawater. 100 Diaphragm The DF-SB series is available with several sealing materials. Depending on the application, the correct diaphragm should be selected. In the following table a concise overview is presented of compatible media. 10 0 1 2 3 4 5 6 7 8 9 10 dp (bar) 3/8" & 1/2" 3/4" 1" 1.4. Duty cycle The solenoid valve is suitable for continuous use. High switching frequencies and high pressures can reduce the lifespan. MANUAL-DF-SB-EN v1.2 www.jpfluidcontrol.com 2

1.5. Compliance The coils are CE marked and comply with the LVD Directive (2006/95/EC) and EMC Directive (2004/108/EC), provided that the cables and connectors are properly connected. 1.6. Type label The coil properties are displayed on a label on the coil. A second label is provided with the valve that shows all relevant valve parameters. This label must be attached to the other side of the coil. In the figure below, an example is shown. COIL JP FLUID CONTROL CS2-230AC 230V~50Hz IP-65 VALVE JP FLUID CONTROL DF-SB034B200E Normally Open Pipe: 3/4" Seal: EPDM Orifice: 20 mm Pressure (AC /DC): 0 - (5 /3 ) bar 1.7. Exploded view PRODUCTCODE (Series & Voltage) VOLTAGE & FREQUENCY CE-MARK PROTECTION GRADE PRODUCTCODE POSITION PIPE CONNECTION SEAL MATERIAL ORIFICE MAXIMUM PRESSURE In the figure below is displayed an exploded drawing of the DF-SB series. # Brass (B) Stainless Steel (S) 1 Galvanize d Brass Galvanized Brass 2 Aluminum Aluminum 3 NBR NBR 4 PA PA 5 Epoxy Epoxy 6 Top: 430F Rest: SS 304 7 NBR/EPDM /FKM Top: 430F Rest: SS 304 NBR/EPDM/ FKM 8 430F 430F 9 SS 302 SS 302 10 SS 302 SS 302 11 SS 302 SS 302 12 SS 302 SS 302 13 NBR/EPDM /FKM NBR/EPDM/ FKM 14 SS 302 SS 302 15 PTFE PTFE 16 Brass 37800 SS 316 17 PTFE PTFE 18 SS 302 SS 302 19 Brass 37800 SS 316 20 SS 302 SS 302 21 NBR/EPDM /FKM 22 Brass 37800 NBR/EPDM/ FKM SS 316 2. GENERAL SAFETY INSTRUCTIONS This product is not a safety device and may not be used as such. Damage caused by improper use, falling, improper operating conditions or other reasons, may cause improper functioning of the solenoid. Correct transport, proper storage and installation, and proper use and maintenance, are essential for reliable and error-free operation. It is the responsibility of the user to select the right product for the application. The product may not function properly as a result of dirt, wear, damage (for example, by dropping) or improper use. Therefore, the product should not be used in applications where a malfunction can cause danger or damage. This product is not intended or approved for medical applications, food and/or application in gas appliances. Solenoid valves can only be used with clean liquids or gases. It is recommended to install a filter before the solenoid valve. Check the compatibility of the medium used, temperature and other operating conditions with the materials and specifications of the product. MANUAL-DF-SB-EN v1.2 www.jpfluidcontrol.com 3

Never exceed the limits for pressure, temperature or voltage as indicated on the product and/or in the technical documentation. The temperature of a solenoid valve coil can rise during operation; this is normal. Overheating will cause smoke and a burning smell. In this case, the power supply must immediately be disconnected. Warning: a valve opens and closes quickly. Improper use can cause pressure transients (fluid hammer) in the pipes with possible damage as a consequence. It is not allowed to change the construction of the valve. Beware of electric shock when working with electrical equipment. before installing the valve. It is recommended to install a filter (500 µm) before the solenoid valve. Mounting the valve Be aware of the direction of flow of the medium when installing the valve. Solenoid valves with an arrow on the housing must be connected in the indicated direction. The pipes on both sides of the valve must be securely fastened. Use a wrench for both valve and pipe while tightening to prevent unnecessary stresses in the system. The solenoid valve must be fixed via the provided connection points. Only exert force at the designated areas on the body such as the hexagon; never to the coil or armature. Avoid vibration in the pipes. Use a suitable sealant for threaded connections of the solenoid valve. Avoid the entry of thread sealing material in the valve, this can lead to malfunctioning of the valve. 3. INSTALLATION AND MAINTENANCE 1.1. Safety instructions before starting Position It is recommended to install the solenoid in vertical position with the coil facing upwards. This reduces the probability of the collection of debris in the solenoid valve. When the solenoid valve is mounted at an angle, it is recommended to deviate maximally 90 from the vertical position. It is recommended to install the product in a dry environment. In moist environments, make sure that no moisture can penetrate the coil, actuator or connector. Install the solenoid valve in a safe way to avoid electric shock, burning or other injuries. Ensure that the solenoid valve is installed in an area with adequate ventilation to facilitate heat dissipation. Make sure the solenoid valve is not in contact with or in the vicinity of flammable materials. Ensure that the product is protected from frost. Frost may damage the product and/or block the moving parts, causing the product to malfunction. Operations may only be performed when the system is not pressurized, electrically disconnected and cooled down. Turn off the power supply before performing any work on the solenoid valve to prevent the risk of electrical shock and to prevent activation of the solenoid valve. The product is only safe when properly installed and operated by qualified persons. Please read the safety instructions and technical documentation carefully before installation, use or maintenance. Always make sure to start the installation safely after installation or maintenance. Water hammer is a typical consequence of a high flow rate and pressure in pipes with small diameters. There are several solutions to this problem: Reduce the pressure with a pressure reducing valve before the solenoid valve. Increase the pipe diameter if possible. Dampen the water hammer by using a flexible hose or buffer before the solenoid valve. Maximum angle 90. 1.2. Installation Clean fluids and gases The solenoid valve can be used in combination with clean liquids or gases. Make sure that the pipe may contain dirt MANUAL-DF-SB-EN v1.2 www.jpfluidcontrol.com 4

IN OUT Check the flow direction with the help of the indications on the valve body. Only exert force at the designated faces, never at the coil or armature. Installation of the coil Attach the label with the valve characteristics on the coil. The device can be damaged by the use of unsuitable tools. The temperature of the coil increases during use, this is normal. Overheating will cause smoke and a burning smell. In this case, the power supply must be shut down immediately. The coils can be rotated if the coil nut is loosened. After the determination of the correct position, the nut should be fastened with a torque of 5Nm. Installation of the cable plug Always connect the ground (3), which is provided with a residual current device at voltages above 50V. Never use liquid or gas piping for grounding electrical equipment. The power supply is connected to terminals (1) and (2). The polarity does not matter. Verify the voltage and frequency before connecting the coil. When mounting the connector, make sure that no moisture can ingress between the coil and connector. The connector screws should be fastened with a torque of 0.5Nm. Connecting the power supply Never connect power to the coil when it is not attached to the solenoid valve! The coil may burn out. Only connect power if you are sure that there is no pressure in the system and no hazardous situations can occur. MANUAL-DF-SB-EN v1.2 www.jpfluidcontrol.com 5

3 1 1 2 2 3 Product code Orifice Pipe Seal DF-SB-160N-REV DN 13 mm 3/8", 1/2" NBR DF-SB-160E-REV DN 13 mm 3/8", 1/2" EPDM DF-SB-160F-REV DN 13 mm 3/8", 1/2" FKM DF-SB-200N-REV DN 20 mm 3/4" NBR DF-SB-200E-REV DN 20 mm 3/4" EPDM DF-SB-200F-REV DN 20 mm 3/4" FKM DF-SB-250N-REV DN 25 mm 1" NBR DF-SB-250E-REV DN 25 mm 1" EPDM DF-SB-250F-REV DN 25 mm 1" FKM The product code of the coil is as follows: Connector: EN 175301-803 (formerly DIN 43650A). The poles (1) and (2) should be connected to the power supply, polarity is not important. Pole (3) is the ground. Connect the connector thoroughly to avoid ingress of moisture. Ensure that drops cannot slip along the cable and enter the connector 4. SPARE PARTS The wear parts of the solenoid valve can be replaced with a repair kit (plunger, plunger spring, membrane, membrane spring, O-ring). Product code CS2-380AC CS2-230AC CS2-120AC CS2-024AC CS2-024DC CS2-012DC Voltage 380V AC 50Hz 230V AC 50Hz 120V AC 60Hz 24VAC 50Hz 24V DC 12V DC Follow the drawing in 1.7 for the correct assembly of the solenoid valve. 5. DISPOSAL The removal of the product should be performed in accordance with the applicable laws. Keep in mind the media that are still present in the valve. This manual can be downloaded from www.jpfluidcontrol.com Modifications reserved JP Fluid Control This document has been prepared with great care. JP Fluid control assumes no responsibility for any errors that may appear in this document. No rights can be derived from this document MANUAL-DF-SB-EN v1.2 www.jpfluidcontrol.com 6