Solenoid Valve ST-IA-series

Similar documents
Solenoid Valve ST-SA-series

Solenoid Valve DF-SB-series

Solenoid Valve DF-SA-series

Center Center Exhaust Pressurized PS-32AS PS-32BS PS-32AD PS-32BD PS-520S PS-520D PS-53CD PS-53ED PS-53PD. Series PS. Function

Type 6213 EV, 6281 EV

Servo-operated 2/2-way solenoid valves Type EV220A

Solenoid valves VZWM-L, NPT

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Solenoid valves VZWM-L

Solenoid valves VZWM-L

2/2-way Solenoid Valve with servo diaphragm

Solenoid valves 2/2-way servo operated type EV220B 15 50

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Solenoid valve Types EV220B 15 - EV220B 50

2/2-way Solenoid Valve for liquids and gases

Assisted lift operated 2/2-way solenoid valves Type EV250B

2/2-way assisted lift operated solenoid valve type EV250B

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

Solenoid valve Types EV220B 15 - EV220B 50

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210B. February 2002 DKACV.PD.200.A B1504

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

how to use solenoid valves INDUSTRIAL CONTROLS DKACV.PS.600.A3.02 / 520B1389

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

Technical Principles of Valves

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Nessie 2/2 way Solenoid valves for High Pressures and High Temperatures, type VDHT

3/2-way Solenoid Valve for pneumatics

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Direct-acting 2/2-way plunger valve

Solenoid valves, 2/2-way servo-operated type EV220B 6-22

OPD min max a c max d c. code [ISO 228 G] [mm] [l/min] [barg] [barg] [barg] code [Volts/Hz]

Solenoid valves VZWP, servo-controlled

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

MAKING MODERN LIVING POSSIBLE. Solenoid valves, 2/2-way assisted lift operated type EV251B Technical brochure

2/2 or 3/2 way direct acting rocker solenoid valve

Direct-acting 2/2- or 3/2-way pivoted armature valve

Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions

Direct-acting 3/2 way plunger valve

Mounting and Operating Instructions EB 5868/5869 EN

Angle seat valve with piston actuator VZXA-...-K

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

GEMÜ 205 Electrically operated solenoid valve

Solenoid valves 2/2-way servo-operated Type EV220B 15-50

SOLENOID VALVES 1. GENERAL PURPOSE VALVES ACCESSORIES ORDER CODIFICATION : TEC22 DIRECT ACTING INDIRECT ACTING

MINIATURE SOLENOID GENERAL SERVICE VALVES

2/2- and 3/2-way solenoid valve for aggressive fluids

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Angle seat valve with diaphragm actuator VZXA-...-M

2/2-way and 3/2-way Normally Closed (NC) and Normally Open (NO)

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

Type Modular Water Valve System servo-assisted; variable and extendable. 2/2 way; DN mm; 1 up to 7 bar Advantages / Benefits

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

L32.5S FIG WAFER BUTTERFLY VALVE

Angle seat valve with piston actuator VZXA-...-K

Type EV224B. Servo-operated 2/2-way solenoid valves for high pressure air. Data sheet

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Common wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Servo-operated 2/2-way solenoid valves for high pressure

Type /2-way globe valve 2/2-Wege-Geradsitzventil Vanne à siège droit 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

2/2-way Globe Valve for media up to +180 C, DN

Solenoid System FLANGE MOUNTING VERSION

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Features PNEUMAT IC VALVES. Pneumatic valves Vip - Pneumatic coaxial valve GENERAL FEATURES CONTROL MEDIA OPERATING MEDIA

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Solenoid Valves. Product Information. It s all at Albion

2/2-way Miniature Solenoid Valve

HERZ-Motorised flow controler

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

AirLINE and AirLINE Quick electrical/pneumatic Automation System

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

Transcription:

2/2-WAY INDIRECT OPERATED NORMALLY CLOSED Solenoid Valve ST-IA-series The ST-IA is an indirect operated 2/2-way solenoid valve. The valve is normally closed. The solenoid valves have an orifice of 13 to 50 mm and can be used with a minimum differential pressure of 0.5 bars. The body material can be brass or stainless steel with a NBR, EPDM or FKM seal. The ST-IA solenoid valves are compatible with all coils from the CS1-series. Example of product code Operation ST I A 034 B 130 N - 230AC Series Standard Dimensions Indirect Position Normally Closed 3/4" Pipe Body Brass DN 13mm Orifice Seal NBR 230V AC Voltage Series Function Operation Position Body Seal & Media Temperature Ambient Temperature Min. Press. Difference Max. Pressure Coil series Voltage Insulation Class Power Duty Cycle Standard (ST) 2/2 way Indirect operated (I) Normally closed (A) Brass (B) / SS 316 (S) NBR (N) EPDM (E) FKM (F) Max 50 C 0.5 bar 16 bar CS1-10..80 C -30..130 C -10..120 C 380V AC 50Hz (380AC) 230V AC 50/60Hz (230AC) 120V AC 50Hz (120AC) 24V AC 50/60Hz (024AC) 24V DC (024DC) 12V DC (012DC) Class F 13 W / 17 VA 100% ED Connector EN 175301-803 (formerly DIN 43650A) Protection Class IP 65 (with cable plug) 2 2 Circuit Diagram 1 1 Pipe (P) Orifice (D) Kv (m3/h) AxBxH (mm) Response Time Open/Close 3/8" (038) 13 mm (130) 3.84 66x48x112 50/180 ms 1/2" (012) 13 mm (130) 3.84 66x48x112 50/180 ms 3/4" (034) 20 mm (200) 6.4 75x58x118 70/220 ms 1" (100) 25 mm (250) 10.24 96x70x131 80/250 ms 1-1/4" (114) 40 mm (400) 18.77 131x96x146 160/360 ms 1-1/2" (112) 40 mm (400) 25.59 131x96x146 160/360 ms 2" (200) 50 mm (500) 40.94 165x120x167 190/540 ms MANUAL-ST-IA-EN v1.2 www.jpfluidcontrol.com 1

1. TECHNICAL SPECIFICATIONS 1.1. Principle of operation A solenoid valve is a valve for neutral, clean liquids and gases, which is electrically controlled with the aid of a solenoid. 2/2 way means that the valve has two ports (input/output) and two positions (closed/open). The valve is normally closed, this means that the valve is closed when deenergized. Indirect operated solenoid valves using the differential pressure of the medium on the ports to open and close the orifice. A minimum differential pressure of 0.5 bar required for proper operation. Furthermore, they can control a high flow rate with a relatively small solenoid coil. They can be used in only one flow direction. This type of solenoid valves is for example used in irrigation systems where the pressure is far above 1 bar and a large orifice is desired. Indirect operated valves open slower than direct operated valves and require a minimum differential pressure but are well suited for high flow rates. 1.2. Area of application Body material The ST-IA series is available with a brass or stainless steel body material. Depending on the application, the right material should be selected. Diaphragm Temperature Allowed media FKM -10 C.120 C Most fuels and oils, cold water, detergents, compressed air. EPDM -30 C.130 C Water and steam, alcohol. NBR -10 C.80 C Neutral media, like air, cold water, hydraulic oil. 1.3. Flow chart Not allowed Glycol-based brake fluids, ammonia gas, hot water and steam, low molecular weight organic acids (such as acetic acid). Oils, fats, fuels, solvents. Fuels, strong acids, brake fluid. In the flow chart, the flow of water from 20 C is shown as a function of the positive pressure difference across the valve. The flow rate is expressed in liters per minute and the pressure in bar. 1000 Body material Allowed media Brass (ASTM #37800) Neutral and non-corrosive media. Stainless Steel (SS 316) Suitable for aggressive media and corrosive media like seawater. Diaphragm The ST-IA series are available with several materials. Depending on the application the correct diaphragm should be selected. In the following table a concise overview is presented of compatible media. Flow rate water (l/min) 100 10 0.5 2.5 4.5 6.5 8.5 10.5 12.5 14.5 dp (bar) 3/8" & 1/2" 3/4" 1" 1-1/2" 2" 1.4. Duty cycle The solenoid valve is suitable for continuous use. High switching frequencies and high pressures can reduce the lifespan. MANUAL-ST-IA-EN v1.2 www.jpfluidcontrol.com 2

1.5. Compliance The coils are CE marked and comply with the LVD Directive (2006/95/EC) and Directive (2004/108/EC), provided that the cables and connectors are properly connected. 1.6. Type label The coil properties are displayed on a label on the coil. A second label is provided with the valve that shows all relevant valve parameters. This label must be attached to the other side of the coil. In the figure below, an example is shown. COIL # Brass (B) Stainless Steel (S) 1 SS 302 SS 302 2 SS 302 SS 302 3 PA PA 4 Epoxy Epoxy 5 Top: 430F Rest: SS 304 6 NBR/EPDM Top: 430F Rest: SS 304 NBR/EPDM 7 SS 302 SS 302 8 430F 430F 9 SS 302 SS 302 10 Brass #37800 SS 316 11 SS 302 SS 302 12 NBR/EPDM NBR/EPDM 13 Brass #37800 SS 316 JP FLUID CONTROL CS1-230AC 230V~50Hz IP-65 PRODUCTCODE (Series & Voltage) VOLTAGE & FREQUENCY CE-MARK PROTECTION GRADE VALVE JP FLUID CONTROL ST-IA012B130E Normally Closed Pipe: 1/2" Seal: EPDM Orifice: 13 mm Pressure (AC /DC): 0.5 - (16 /16 ) bar 1.7. Exploded view PRODUCTCODE POSITION PIPE CONNECTION SEAL MATERIAL ORIFICE MAXIMUM PRESSURE In the figure below is an exploded drawing of the ST-IA series displayed. 2. GENERAL SAFETY INSTRUCTIONS This product is not a safety device and may not be used as such. Damage caused by improper use, falling, improper operating conditions or other reasons, may cause improper functioning of the solenoid. Correct transport, proper storage and installation, and proper use and maintenance, are essential for reliable and error-free operation. It is the responsibility of the user to select the right product for the application. The product may not function properly as a result of dirt, wear, damage (for example, by dropping) or improper use. Therefore, the product should not be used in applications where a malfunction can cause danger or damage. This product is not intended or approved for medical applications, food and/or application in gas appliances. Solenoid valves can only be used with clean liquids or gases. It is recommended to install a filter before the solenoid valve. Check the compatibility of the medium used, temperature and other operating conditions with the materials and specifications of the product. Never exceed the limits for pressure, temperature or voltage as indicated on the product and/or in the technical documentation. MANUAL-ST-IA-EN v1.2 www.jpfluidcontrol.com 3

The temperature of a solenoid valve coil can rise during operation; this is normal. Overheating will cause smoke and a burning smell. In this case, the power supply must immediately be disconnected. Warning: a valve opens and closes quickly. Improper use can cause pressure transients (fluid hammer) in the pipes with possible damage as a consequence. It is not allowed to change the construction of the valve. Beware of electric shock when working with electrical equipment. Mounting the valve Be aware of the direction of flow of the medium when installing the valve. Solenoid valves with an arrow on the housing must be connected in the indicated direction. The pipes on both sides of the valve must be securely fastened. Use a wrench for both valve and pipe while tightening to prevent unnecessary stresses in the system. The solenoid valve must be fixed via the provided connection points. Only exert force at the designated areas on the body such as the hexagon; never to the coil or armature. Avoid vibration in the pipes. Use a suitable sealant for threaded connections of the solenoid valve. Avoid the entry of thread sealing material in the valve, this can lead to malfunctioning of the valve. 3. INSTALLATION AND MAINTENANCE 1.1. Safety instructions before starting Position It is recommended to install the solenoid in vertical position with the coil facing upwards. This reduces the probability of the collection of debris in the solenoid valve. When the solenoid valve is mounted at an angle, it is recommended to deviate maximally 90 from the vertical position. It is recommended to install the product in a dry environment. In moist environments, make sure that no moisture can penetrate the coil, actuator or connector. Install the solenoid valve in a safe way to avoid electric shock, burning or other injuries. Ensure that the solenoid valve is installed in an area with adequate ventilation to facilitate heat dissipation. Make sure the solenoid valve is not in contact with or in the vicinity of flammable materials. Ensure that the product is protected from frost. Frost may damage the product and/or block the moving parts, causing the product to malfunction. Operations may only be performed when the system is not pressurized, electrically disconnected and cooled down. Turn off the power supply before performing any work on the solenoid valve to prevent the risk of electrical shock and to prevent activation of the solenoid valve. The product is only safe when properly installed and operated by qualified persons. Please read the safety instructions and technical documentation carefully before installation, use or maintenance. Always make sure to start the installation safely after installation or maintenance. Water hammer is a typical consequence of a high flow rate and pressure in pipes with small diameters. There are several solutions to this problem: Reduce the pressure with a pressure reducing valve before the solenoid valve. Increase the pipe diameter if possible. Dampen the water hammer by using a flexible hose or buffer before the solenoid valve. Maximum angle 90. Check the flow direction with the help of the indications on the valve body. 1.2. Installation Clean fluids and gases The solenoid valve can be used in combination with clean liquids or gases. Make sure that the pipe may contain dirt before installing the valve. It is recommended to install a filter (500 μm) before the solenoid valve. Only exert force at the designated faces, never at the coil or armature. Installation of the coil Make sure the coil is labeled with the valve characteristics. The device can be damaged by the use of unsuitable tools. MANUAL-ST-IA-EN v1.2 www.jpfluidcontrol.com 4

The temperature of the coil increases during use, this is normal. Overheating will cause smoke and a burning smell. In this case, the power supply must be shut down immediately. The coils can be rotated if the coil nut is loosened. After the determination of the correct position, the nut should be fastened with a torque of 5Nm. Connector: EN 175301-803 (formerly DIN 43650A). The poles (1) and (2) should be connected to the power supply, polarity is not important. Pole (3) is the ground. Connect the connector thoroughly to avoid ingress of moisture. Ensure that drops cannot slip along the cable and enter the connector. 4. SPARE PARTS Installation of the cable plug Always connect the ground (3), which is provided with a residual current device at voltages above 50V. Never use liquid or gas piping for grounding electrical equipment. The power supply is connected to terminals (1) and (2). The polarity does not matter Verify the voltage and frequency before connecting the coil. When mounting the connector, make sure that no moisture can ingress between the coil and connector. The connector screws should be fastened with a torque of 0.5Nm. Connecting the power supply Never connect power to the coil when it is not attached to the solenoid valve! The coil may burn out. Only connect power if you are sure that there is no pressure in the system and no hazardous situations can occur. The wear parts of the solenoid valve can be replaced with a repair kit (plunger, plunger spring, membrane, membrane spring, O-ring). Product code Orifice Pipe Seal ST-IA-130N-REV DN 13 mm 3/8", 1/2" NBR ST-IA-130E-REV DN 13 mm 3/8", 1/2" EPDM ST-IA-130F-REV DN 13 mm 3/8", 1/2" FKM ST-IA-200N-REV DN 20 mm 3/4" NBR ST-IA-200E-REV DN 20 mm 3/4" EPDM ST-IA-200F-REV DN 20 mm 3/4" FKM ST-IA-250N-REV DN 25 mm 1" NBR ST-IA-250E-REV DN 25 mm 1" EPDM ST-IA-250F-REV DN 25 mm 1" FKM ST-IA-400N-REV DN 40 mm 1-1/4",1-1/2" NBR ST-IA-400E-REV DN 40 mm 1-1/4",1-1/2" EPDM ST-IA-400F-REV DN 40 mm 1-1/4",1-1/2" FKM ST-IA-500N-REV DN 50 mm 2" NBR ST-IA-500E-REV DN 50 mm 2" EPDM ST-IA-500F-REV DN 50 mm 2" FKM The product code of the coil is as follows: Product code Voltage CS1-380AC 380V AC 50Hz CS1-230AC 230V AC 50Hz CS1-120AC 120V AC 60Hz CS1-024AC 24V AC 50Hz CS1-024DC 24V DC CS1-012DC 12V DC MANUAL-ST-IA-EN v1.2 www.jpfluidcontrol.com 5

Follow the drawing in 1.7 for the correct assembly of the solenoid valve. 5. DISPOSAL The removal of the product should be performed in accordance with the applicable laws. Keep in mind the media that are still present in the valve. This manual can be downloaded from www.jpfluidcontrol.com Modifications reserved JP Fluid Control This document has been prepared with great care. JP Fluid control assumes no responsibility for any errors that may appear in this document. No rights can be derived from this document MANUAL-ST-IA-EN v1.2 www.jpfluidcontrol.com 6