Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue

Similar documents
Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Vacuum Circuit Breakers kv

Vacuum Circuit Breakers kv

Circuit protection and control devices 0.5 to 6300 A

Operating conditions. Generalities. Normal operating conditions

Masterpact NT and NW LV power circuit breakers and switch-disconnectors

Circuit protection and control devices 0.5 to 6300 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Circuit protection and control devices. 0.5 to 6300 A. LV product characteristics

cor Long Run Experience

DMX 3 -I 2500 switch disconnectors

Compact Merlin Gerin 80 to 3200 A

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

DPX 1600 Electronic release

DPX earth leakage DPX 3 -I earth leakage


Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

DPX 630 Electronic release

DPX moulded case circuit breakers


Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

(p. 47) (p. 155) (p. 155)

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX Electronic + earth leakage

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

3 - Protection components Motor circuit-breakers

DRX 125 Circuit breaker (not adjustable)

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

Moulded case circuit breakers

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

Protection components

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

01 Spectra Plus - Introduction

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

Low voltage moulded case circuit breaker EB2

Cascading & Discrimination

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

DPX Magnetic only

Price List. Low Voltage Distribution Products. With effect from December 29, schneider-electric.co.in

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

DRX 250 B/N/H Circuit breaker (not adjustable)

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A

Thermal magnetic and trip-free switches

Power protection solutions

Memshield - ACB Ratings & Specifications

Breaking and protection devices

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

DRX 100 B/N/H Circuit breaker (not adjustable)

Price List. Low Voltage Distribution Products. With effect from March 12, schneider-electric.co.in

Compact NR630. NR100F to NR630F

Wall mounted switchgear

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

OPERATING CHARACTERISTICS

- Moulded-case Circuit Breaker

AF40... AF96 3-pole contactors Technical data

Air Circuit Breakers DH series General information

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

WORKSHOP SPECIFICATIONS

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

Miniature circuit breakers. Residential current circuit breaker. Busbar systems. Comfort functions/energy control. Residential enclosures

ACB l COMET AIR CIRCUIT BREAKER

Breakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary

Low voltage moulded case circuit breaker EB2

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A.

low voltage GLOBAL CATALOGUE RANGE ACB Air Circuit Breakers

Magnum IEC Low Voltage Air Circuit Breakers

Masterpact NW DC Circuit Breakers

atalog Welcome to ATO.com! Contact us... Tel: (Toll-free) Website:

ACB l COMET AIR CIRCUIT BREAKER

Power Devices Catalogue 2013

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

D509E. Manual Motor - Starters

Phase + Neutral, neutral on left side

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Industrial Contactors CTX 3 3P 185A - 800A

C60H-DC C curve. Catalogue numbers

Phase + Neutral, neutral on right side

Molded Case Circuit Breaker

World Super Series WSS The extensive breaker series from Mitsubishi Electric

Transcription:

Low voltage Masterpact NT and NW LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type Catalogue 2015

Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 PB106365A49 Common characteristics Number of poles 3/4 Rated insulation voltage (V) Ui 1000 Impulse withstand voltage (kv) Uimp 12 Rated operational voltage () Ue 690 Suitability for isolation IEC 60947-2 Degree of pollution IEC 60664-1 3 Basic sweatchgear Circuit-breaker as per IEC 60947-2 Rated current (A) In at 40 C/50 C (1) Rating of 4th pole (A) Sensor ratings (A) Ultimate breaking capacity (ka rms) Icu 220/415 V 440 V 525 V Rated service breaking capacity (ka rms) Ics %Icu Utilisation category Rated short-time withstand current (ka rms) Icw 0.5 s 1 s Integrated instantaneous protection (ka peak ±10 %) Rated making capacity (ka peak) Icm 220/415 V 440 V 525 V Break time (ms) between tripping order and arc extinction Closing time (ms) Circuit-breaker as per NEMA AB1 Breaking capacity (ka) 240 V 480 V 600 V (1) 50 C: rear vertical connected. Refer to temperature derating tables for other connection types. (2) See the current-limiting curves in the additional characteristics section. (3) SELLIM system. (4) Available for 480 V NEMA. (5) Suitable for motor control (direct-on-line starting). Switch-disconnector as per IEC 60947-3 and Annex A Type of switch-disconnector Rated making capacity (ka peak) Icm 220 V AC23A/AC3 category 440 V 525/ Rated short-time withstand current (ka rms) Icw 0.5 s AC23A/AC3 category 1 s Ultimate breaking capacity Icu (ka rms) with an external protection relay Maximum time delay: 350 ms Mechanical and electrical durability as per IEC 60947-2/3 at In/Ie Service life Mechanical without maintenance C/O cycles x 1000 Rated current In (A) C/O cycles x 1000 Electrical without maintenance 440 V (4) IEC 60947-2 or switch-disconnector Rated operationnal current Ie (A) AC23A C/O cycles x 1000 Electrical without maintenance 440 V (4) IEC 60947-3 690V or switch-disconnector Rated operationnal current Ie (A) AC3 (5) Motor power 380/415 V (kw) 440 V (kw) C/O cycles x 1000 Electrical without maintenance 440 V (4) IEC 60947-3 Annex M/IEC 60947-4-1 01

Sensor selection Sensor rating (A) 250 (1) 400 630 800 1000 1250 1600 Ir threshold setting(a) 100 to 250 160 to 400 250 to 630 320 to 800 400 to 1000 500 to 1250 640 to 1600 (1) For circuit-breaker NT02, please consult us. NT06 NT08 NT10 NT12 NT16 630 800 1000 1250 1600 630 800 1000 1250 1600 400 to 630 400 to 800 400 to 1000 630 to 1250 800 to 1600 H1 H2 L1 (2) H1 H2 42 50 150 42 50 42 50 130 42 50 42 42 100 42 42 42 42 25 42 42 100 % 100 % B B A B B 42 36 10 42 36 42 36-42 36 24 20-24 20-90 10 x In (3) - 90 88 105 330 88 105 88 105 286 88 105 88 88 220 88 88 88 88 52 88 88 25 25 9 25 25 < 50 < 50 42 50 150 42 50 42 50 100 42 50 42 42 25 42 42 HA HA 75 75 75 75 75 75 36 36 36 36 20 20 36 36 12.5 H1 H2 L1 H1 H2 L1 H1 H2 L1 H1 H2 H1 H2 630 800 1000 1250 6 6 3 6 6 3 6 6 3 6 6 3 3 3 3 2 3 3 2 3 3 2 3 3 1 1 H1/H2/HA 630 800 1000 1250 1600 6 6 6 6 3 3 3 3 3 1 H1/H2/HA 500 630 800 1000 1000 250 250 to 335 335 to 450 450 to 560 450 to 560 300 300 to 400 400 to 500 500 to 630 500 to 630 6-02

Functions and characteristics Circuit breakers and switch-disconnectors NW08 to NW63 PB106363A35 Common characteristics Number of poles 3/4 Rated insulation voltage (V) Ui 1000/1250 Impulse withstand voltage (kv) Uimp 12 Rated operational voltage () Ue 690/1150 Suitability for isolation IEC 60947-2 Degree of pollution IEC 60664-1 4 (1000 V) / 3 (1250 V) Basic circuit-breaker Circuit-breaker as per IEC 60947-2 Rated current (A) at 40 C / 50 C (1) Rating of 4th pole (A) Sensor ratings (A) PB106362A65 (1) 50 C: rear vertical connected. Refer to temperature derating tables for other connection types. (2) See the current-limiting curves in the additional characteristics section. (3) Equipped with a trip unit with a making current of 90 ka peak. (4) External protection must comply with permissible thermal constraints of the circuit breaker (please consult us). No fault-trip indication by the SDE or the reset button. (5) Available for 480 V NEMA. (6) Suitable for motor control (direct-on-line starting). (7) The use of NW08 to NW20 H1 in IT systems is limited to 500 V network voltage. Ultimate breaking capacity (ka rms) Rated service breaking capacity (ka rms) Ics %Icu Utilisation category Rated short-time withstand current (ka rms) VAC50/60 Hz Icw 1 s Integrated instantaneous protection (ka peak ±10 %) Rated making capacity (ka peak) Break time (ms) between tripping order and arc extinction Closing time (ms) Circuit-breaker as per NEMA AB1 Breaking capacity (ka) Icu Icm 220/415/440 V 525 V 1150 V 220/415/440 V 525 V 1150 V 240/480 V 600 V Unprotected circuit-breaker Tripping by shunt trip as per IEC 60947-2 Ultimate breaking capacity (ka rms) Icu 220... Rated service breaking capacity (ka rms) Ics %Icu Rated short-time withstand current (ka rms) Icw 1 s Overload and short-circuit protection External protection relay: short-circuit protection, maximum delay: 350 ms (4) Rated making capacity (ka peak) Icm 220... Switch-disconnector as per IEC 60947-3 and Annex A Type of switch-disconnector Rated making capacity (ka peak) AC23A/AC3 category Rated short-time withstand current (ka rms) AC23A/AC3 category Icm Icw 220... 1150 V 1 s Earthing switch Latching capacity (ka peak) 135 Rating short time withstand (ka rms) Icw 1 s Mechanical and electrical durability as per IEC 60947-2/3 at In/Ie Service life Mechanical with maintenance C/O cycles x 1000 without maintenance Rated current In (A) C/O cycles x 1000 Electrical without maintenance 440 V (5) IEC 60947-2 1150 V or switch-disconnector Rated operational current Ie (A) AC23A C/O cycles x 1000 Electrical without maintenance 440 V (5) IEC 60947-3 or switch-disconnector Rated operational current Ie (A) AC3 (6) Motor power 380/415 V (kw) 440 V (5) (kw) (kw) C/O cycles x 1000 Electrical without maintenance 440/ (5) IEC 60947-3 Annex M/IEC 60947-4-1 03

Sensor selection Sensor rating (A) 250 (1) 400 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 Ir threshold setting(a) 100 160 250 320 400 500 630 800 1000 1250 1600 2000 2500 to 250 to 400 to 630 to 800 to 1000 to 1250 to 1600 to 2000 to 2500 to 3200 to 4000 to 5000 to 6300 (1) For circuit-breaker NW02, please consult us. NW08 NW10 NW12 NW16 NW20 NW25 NW32 NW40 NW40b NW50 NW63 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 400 to 800 400 to 1000 630 to 1250 800 to 1600 1000 to 2000 1250 to 2500 1600 to 3200 2000 to 4000 2000 to 4000 2500 to 5000 3200 to 6300 N1 H1 (7) H2 L1 (2) H10 H1 (7) H2 H3 L1 (2) H10 H1 H2 H3 H10 H1 H2 42 65 100 150-65 100 150 150-65 100 150-100 150 42 65 85 130-65 85 130 130-65 85 130-100 130 42 65 85 100-65 85 100 100-65 85 100-100 100 - - - - 50 - - - - 50 - - - 50 - - 100 % 100 % 100 % 100 % B B B B 42 65 85 30 50 65 85 65 30 50 65 85 65 50 100 100 22 36 50 30 50 36 75 65 30 50 65 75 65 50 100 100 - - 190 80 - - 190 150 80 - - 190 150 - - 270 88 143 220 330-143 220 330 330-143 220 330-220 330 88 143 187 286-143 187 286 286-143 187 286-220 286 88 143 187 220-143 187 220 220-143 187 220-220 220 - - - - 105 - - - - 105 - - - 105 - - 25 25 25 10 25 25 25 25 10 25 25 25 25 25 25 25 < 70 < 70 < 70 < 80 42 65 100 150-65 100 150 150-65 100 150-100 150 42 65 85 100-65 85 100 100-65 85 100-100 100 HA HF (3) HA HF (3) HA HF (3) HA 50 85 50 85 55 85 85 100 % 100 % 100 % 100 % 50 85 50 85 55 85 85 36 50 36 75 55 75 85 - - - - - - - 105 187 105 187 121 187 187 NW08/NW10/NW12/NW16 NW20 NW25/NW32/NW40 NW40b/NW50/NW63 NA HA HF HA10 HA HF HA10 HA HF HA10 HA 88 105 187-105 187-121 187-187 - - - 105 - - 105 - - 105-42 50 85 50 50 85 50 55 85 50 85-36 50 50 36 75 50 55 75 50 85 60 Hz 50 Hz 25 20 10 12.5 10 5 N1/H1/H2 L1 H10 H1/H2 H3 L1 H10 H1/H2 H3 H10 H1 H2 800/1000/1250/1600 2000 2500/3200/4000 4000b/5000/6300 10 3-8 2 3-5 1.25-1.5 1.5 10 3-6 2 3-2.5 1.25-1.5 1.5 - - 0.5 - - - 0.5 - - 0.5 - - H1/H2/NA/HA/HF H1/H2/H3/HA/HF H1/H2/H3/HA/HF H1/H2/HA 800/1000/1250/1600 2000 2500/3200/4000 4000b/5000/6300 10 8 5 1.5 10 6 2.5 1.5 H1/H2/NA/HA/HF H1/H2/H3/HA/HF 800 1000 1250 1600 2000 335 to 450 450 to 560 560 to 670 670 to 900 900 to 1150 400 to 500 500 to 630 500 to 800 800 to 1000 1000 to 1300 800 800 to 1000 1000 to 1250 1250 to 1600 1600 to 2000 6 04

Functions and characteristics Micrologic control units Micrologic A ammeter and E energy Micrologic E control units protect power circuits. They also offer measurements, display, communication and current maximeters. Version 6 provides earth-fault protection. "Ammeter" measurements (Micrologic A) "Energy meter" measurements (Micrologic E) True RMS current (I1, I2, I3, In, Ig): Micrologic A / Micrologic E current demand voltages: phase to phase, phase to neutral, average (1) and unbalanced (1) E instantaneous power: P, Q, S power factor: PF power demand: P demand 11 energy: Ep, Eq (1), Es (1). Accuracy of active energy Ep is 2 % (including the sensors). The range of 10 measurement is the same as current with Micrologic A, depending of an external power supply module (24 V DC). Communication option In conjunction with the COM communication option, the control unit transmits the 12 following: settings all "ammeter" and "energy" measurements enable connection to FDM121 (E only) tripping causes maximeter / minimeter readings. Protection Protection thresholds and delays are set using the adjustment dials. Overload protection 13 True rms long-time protection. Thermal memory: thermal image before and after tripping. Setting accuracy may be enhanced by limiting the setting range using a different longtime 14 rating plug. Overload protection can be cancelled using a specific LT 15 16 rating plug "Off". Short-circuit protection Short-time (rms) and instantaneous protection. Selection of I 2 t type (ON or OFF) for short-time delay. Earth-fault protection 1 Source ground return earth fault protection. 4 2 Selection of I 2 t type (ON or OFF) for delay. Neutral protection 6 On three-pole circuit breakers, neutral protection is not possible. On four-pole circuit breakers, neutral protection may be set using a three-position switch: neutral unprotected (4P 3d), neutral protection at 0.5Ir (4P 3d+ N/2), neutral 5 7 protection at Ir (4P 4d). Zone selective interlocking (ZSI) 9 A ZSI terminal block may be used to interconnect a number of control units to provide total discrimination for short-time and earth-fault protection, without a delay before 8 3 tripping. Overload alarm A yellow alarm LED goes on when the current exceeds the long-time trip threshold. M2C programmable contacts The M2C (two contacts) programmable contacts may be used to signal envents (Ir, Isd, Alarm Ir, Alarm Ig, Ig). They can be programmed using the keypad on the Micrologic E control unit or remotely using the COM option (BCM ULP). 1 overload alarm (LED) at 1.125 Ir Fault indications 2 long-time rating plug screw LEDs indicate the type of fault: 2.0 3 test connector overload (long-time protection Ir) 5.0 4 long-time threshold and tripping delay short-circuit (short-time Isd or instantaneous li protection) 6.0 5 short-time pick-up earth fault (Ig) 6 short-time tripping delay internal fault (Ap). 7 instantaneous pick-up 8 earth-fault pickup and tripping delay Trip history (E only) 9 earth-fault test button The trip history displays the list of the last 10 trips. For each trip, the following 10 indicator of tripping cause indications are recorded and displayed: 11 lamp test, reset and battery test the tripping cause: Ir, Isd, li, Ig or Auto-protection (Ap) trips 12 digital display the date and time of the trip (requires communication option). A E 13 three-phase bargraph and ammeter Battery power 14 navigation button to view menu contents The fault indication LEDs remain on until the test/reset button is pressed. Under 15 navigation button to change menu normal operating conditions, the battery supplying the LEDs has a service life of 16 navigation button "quick View" approximately 10 years. Test A mini test kit or a portable test kit may be connected to the test connector on the front (1) Display on FDM121 only. Note: Micrologic E control units come with a transparent leadseal cover as standard. to check circuit-breaker operation. For Micrologic 6.0 E control units, the operation of earth-fault or earth-leakage protection can be checked by pressing the test button located above the test connector. DB126649 05

Protection 2.0 5.0 2.0A 5.0A 6.0A 2.0E 5.0E 6.0E Long time (Ir) Current setting (A) trip between 1.05 & 1.20 x Ir Ir = 0.4~1 x In Time setting (s) tr = 0.5~24 Time delay (s) accuracy: 0 to -30%, 1.5 x Ir 12.5~600 accuracy: 0 to -20%, 6 x Ir 0.7~24 accuracy: 0 to -20%, 7.2 x Ir 0.7~16.6 Thermal memory 20 minutes before and after tripping Instantaneous (Isd) Pick-up (A) accuracy: ±10% Isd = 1.5~10 x Ir Time delay (s) max. resettable time: 20ms max. break time: 80ms Short time (Isd) Pick-up (A) accuracy: ±10% Isd = 1.5~10 x Ir Time setting tsd (s) I 2 t Off: 0~0.4 I 2 t On: 0.1~0.4 Time delay (ms) at 10 x Ir max. resettable time tsd: 20~350 (I 2 t off or I 2 t on) max. break time tsd: 80~500 Instantaneous (Ii) Pick-up (A) accuracy: ±10% Ii = 2~15 x In or off Time delay (s) max. resettable time: 20ms Earth fault (Ig) max. break time: 50ms Pick-up (A) Ig = In<400A 0.3~1 x In (accuracy: ±10%) 400A<In<1250A 0.2~1 x In In 1250A 500~1200A Time setting tg (s) I 2 t Off: 0~0.4 I 2 t On: 0.1~0.4 Time delay (ms) max. resettable time tg: 20~350 at In or 1200A (I 2 t off or I 2 t on) max. break time tg: 80~500 Ammeter & Energy type range accuracy 2.0 5.0 2.0A 5.0A 6.0A 2.0E 5.0E 6.0E Instantaneous current I1, I2, I3, IN 0.2~1.2 x In ±1.5% Ig 0.2~1 x In ±10% 0.05~1 x In ±10% Current maximeters I1, I2, I3, IN 0.2~1.2 x In ±1.5% Demand currents I1, I2, I3, Ig 0.2~1 x In ±1.5% Voltages VL-L & VL-N 100~690V ±0.5% Active power P 30~2000kW ±2% Power factor PF 0~1 ±2% Demand power P demand 30~2000kW ±2% Active energy Ep -10 10 ~10 10 GWh ±2% Note: all current-based protection functions require no auxiliary source. The test / reset button resets maximeters, clears the tripping indication and tests the battery. for 5.0P, 6.0P and other Micrologic control units please contact us for more information. 06

Additional characteristics Tripping curves Micrologic 2.0 Earth fault protection (Micrologic 6.0) DB105112 Micrologic 5.0, 6.0, 7.0 DB105113 DB101505 (1) Ig = In x... A B C D E F G H I In < 400 A 0.3 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 400 A In 1250 A 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 In > 1250 A 500 640 720 800 880 960 1040 1120 1200 施耐德電機授權經銷商 東技企業股份有限公司普得企業股份有限公司 總公司 : 台北市內湖區行愛路 68 號 6 樓 電話 :(02)8791-8588 中辦處 :(04)2296-9388 傳真 :(02)8791-9588 高辦處 :(07)227-2133 E-mail:toyotech@ms37.hinet.net 網址 :www.toyotech.com.tw As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. Mar. 2016