GENERATOR & SINGLE-FUNCTION PROTECTION

Similar documents
POWR-GARD Relay Testing Equipment PGT-0400 Series Ground-Fault Relay Test Unit PGT Ground-Fault Relay Test Unit

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

SE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

T-Line Generator Control, Protection and Monitoring

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

34 th Hands-On Relay School

PD-Series Ground Fault Circuit Protection

Blocks and Holders. Specifications. Voltage Rating 600 V Current Rating Based on NEC Table , using 75 C copper wire Material.

Form G5-1 PACIFIC GAS AND ELECTRIC COMPANY GENERATION PRE-PARALLEL INSPECTION

MAGNETIC MOTOR STARTERS

Industry Automation Control Components

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Operator's manual ATSc Instrumentation en-gb

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS

Solid Dielectric, Single Phase Recloser

J1000 D E F I 1000 J1000 J1000 J1000 J1000

Mains. Great performances. Attractive coloured display. PLC functions inbuilt. Several I/O with possibility of expansion modules

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

DGC-2020 DIGITAL GENSET CONTROLLER

NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking)

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Memshield - ACB Ratings & Specifications

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

mgard-10 microprocessor-based relay

Cobra-S. Catalog Cobra-S

Close-Open (Short-Circuit) Time Results Interpretation

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

TRIPS AND FAULT FINDING

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Bolted contact switches. Pringle switches

DATA SHEET Genset Control Unit, GCU 100

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

AUTOMATIC STAND-BY AND PEAK-LOAD CONTROL

max pole for t=15 ms

Solid Dielectric, Three Phase Reclosers CATALOG VS11

How Protection Relays Solve Electrical Problems

Unit Protection System for Pumped-Storage Power Stations

and other modular devices for low voltage installation

PGR-8800 ARC-FLASH RELAY

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Solid Dielectric, Independent Pole Operated Reclosers Catalog O-vst16

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Solid Dielectric, Triple Option Reclosers Catalog O-vst14

INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER

KD LV Motor Protection Relay

Solid Dielectric, Three Phase Reclosers Catalog O-vs18

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

GENSET CONTROL MODULE A121A / A241A

Basics of Paralleling

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Table of Contents. For latest version, visit:

Crane Control Class 9055

REVISION HISTORY REVISION HISTORY

J1000. Compact Inverter Series.

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

Power Systems Trainer

INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBERS

Fifteenth National Power Systems Conference (NPSC), IIT Bombay, December 2008

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Motor. Document # Vari-Green Motor and Controls. Table of Contents. Features, Operation, Wiring and Troubleshooting

LA Motor Protection. A South African Company to be Proud of

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

TERMS AND DEFINITIONS

GFCI-AFCI FAQ. Where are AFCIs and GFCIs required?

ATC-400 Retrofit Kit for 240/120 or 208/120 V Automatic Transfer Switch Instruction Leaflet WARNING CAUTION CAUTION. Removal of ATC-200:

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Versa II SLR Lubricator

ADHERING TO UTILITY INTERCONNECTION STANDARDS MAY NOT GUARANTEE DG SECURITY Wayne G. Hartmann Beckwith Electric Co., Inc. Product Manager, Protection

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Low breaking capacity moulded case circuit breakers

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

PGR-8800 ARC-FLASH RELAY APPLICATION GUIDE

H B - PA N O R A M A

A21M. Introduction: Functional Overview: Key Protection & Control Functions:

TECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008

CUSTOMER / ACCOUNT INFORMATION Electric Utility Customer Information (As shown on utility bill)

SECTION MOTOR CONTROL

GE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers

ASYN205B Central Synchronizing Controller

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

Regenerative Utility Simulator for Grid-Tied Inverters

DPX earth leakage DPX 3 -I earth leakage

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

RUS accepted Catalog O-vst18

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V

DGC-2020 DIGITAL GENSET CONTROLLER

Transcription:

PGR-4300 Generator Ground-Fault Relay No CTs required Provides a simple method for tripping a groundfault condition on generators Use with 3- or 4-pole transfer switches Monitors neutral-to-ground integrity Adjustable pick-up settings from 100 to 1200 A Adjustable time-delay settings from 0 to 1 sec IEEE Device Numbers 50G/N, 51G/N Dimensions H 75 mm (3.0 ) W 55 mm (2.2 ) Communications Analog Output Warranty 5 Year littelfuse.com/pgr-4300 PGR-4300-12 12 Vdc Control Power PGR-4300-24 24 Vdc Control Power PGA-0500 Analog Current Meter PGR-4300-120 120 Vac Control Power G2000 Power Relay Detects power level for protection, control and monitoring PC configuration for forward power or reverse power functionality -36 Vdc/0.75 W at 24 Vdc Input Current 5 A CT, max. 10 A littelfuse.com/g2000 G2000.0010 24 Vdc, 5 A Control Power G0100 Programming Kit G3000 Relay monitor generators, busbars or other PC configuration for over and under frequency protection one unit -36 Vdc/0.75 W at 24 Vdc Input Current 5 A CT, max. 10 A littelfuse.com/g3000 G3000.0010 24 Vdc Control Power G0100 Programming Kit Gross Automation 360 N. 126th St., Brookfield, WI 53005 Toll-Free: 77-26-3700 sales@grossautomation.com www.littelfusesales.com 15 2015 Littelfuse POWR-GARD Products Catalog

G3300 Voltage Relay PC configuration for over and undervoltage protection in one relay Phase symmetry monitor enables use in grid connection applications -36 Vdc/0.75 W at 24 Vdc littelfuse.com/g3300 G3300.0010 24 Vdc Control Power G0100 Programming Kit T2000 Reverse Power Relay Protects the generator from being run as an electric motor ensure correct operation in spite of voltage supply 2-20% I N littelfuse.com/t2000 T2100 Excitation Loss Relay 2015 Littelfuse POWR-GARD Products Catalog ORDERING NUMBER TERMINALS 1-3 TERMINALS 2-3 I N SUPPLY T2000.0010 230 V 5 A L-N T2000.0020 450 V 400 V 5 A L-L T2000.0030 127 V 120 V 5 A L-N T2000.0040 110 V 100 V 5 A L-L T2000.0050 110 V 100 V 5 A L-L T2000.0060 230 V 1 A L-N T2000.0070 5 A L-L T2000.000 450 V 400 V 5 A L-N T2000.0090 127 V 120 V 5 A L-L T2000.0100 110 V 100 V 1 A L-L T2000.0110 450 V 400 V 5 A L-L T2000.0120 40 V 415 V 5 A L-L T2000.0130 230 V 5 A L-N T2000.0140 230 V 5 A L-L T2000.0150 40 V 415 V 1 A L-L T2000.0160 450 V 400 V 1 A L-L Protects against loss of excitation in a synchronous generator ensure correct operation in spite of voltage supply ORDERING NUMBER TERMINALS 1-3 TERMINALS 2-3 I N SUPPLY T2100.0010 230 V 5 A L-N T2100.0020 40 V 415 V 5 A L-L T2100.0030 450 V 400 V 5 A L-L T2100.0040 110 V 100 V 1 A L-L T2100.0050 110 V 100 V 5 A L-L T2100.0060 110 V 100 V 5 A L-L T2100.0070 40 V 415 V 5 A L-L T2100.000 110 V 100 V 5 A L-L Gross Automation 360 N. 126th St., Brookfield, WI 53005 Toll-Free: 77-26-3700 sales@grossautomation.com www.littelfusesales.com 159 0.5-1.5 x I N littelfuse.com/t2100

T2200 3-Phase Overcurrent Relay Designed for generator or feeder protection against overcurrent in each of the 3 phases littelfuse.com/t2200 T2200.0010 450 V 400 V 5 A Latching output, resetable T2200.0020 450 V 400 V 5 A Normally energized output, latching, resetable T2200.0030 230 V 5 A Latching output, resetable T2200.0040 230 V 110 V 5 A Latching output, resetable T2200.0050 230 V 1 A Latching output, resetable T2200.0060 450 V 400 V 5 A Normally energized output, latching, resetable T2200.0070 110 V 100 V 5 A Latching output, resetable T2200.000 40 V 415 V 5 A Latching output, resetable T2200.0090 24 Vdc 5 A Latching output, resetable T2200.0100 450 V 400 V 5 A Instantly extra output relay T2200.0110 450 V 400 V 1 A Instantly extra output relay T2300 3-Phase Short-Circuit Relay Designed for protection of generators, power transmissions and consumer s supply against short circuit 1.0-4.0 x I N 0.1-1.0 sec. littelfuse.com/t2300 T2400 3-Phase Dual Overcurrent Relay T2300.0100 230 V 5 A T2300.0020 450 V 400 V 5 A T2300.0030 24 Vdc 5 A T2300.0040 24 Vdc 1 A T2300.0050 450 V 400 V 5 A Normally de-energized output T2300.0060 40 V 415 V 5 A T2300.0070 230 V 1 A Includes 2 combined overcurrent designed for protection or monitoring of generators and power transmissions Combining 2 relays is an economic solution for non-essential load tripping and occupying less space in the switch panel T2400.0010 230 V 5 A T2400.0020 450 V 400 V 5 A T2400.0030 110 V 100 V 5 A T2400.0040 450 V 400 V 5 A T2400.0050 40 V 415 V 5 A T2400.0060 450 V 400 V 1 A T2400.0070 450 V 400 V 5 A T2400.000 127 V 120 V 5 A T2400.0090 24 Vdc 5 A littelfuse.com/t2400 Latching output on relay 1, 6-60 sec. delay on relay 1 Latching output on relay 1, normally energized relay 1 Gross Automation 360 N. 126th St., Brookfield, WI 53005 Toll-Free: 77-26-3700 sales@grossautomation.com www.littelfusesales.com 160 2015 Littelfuse POWR-GARD Products Catalog

T2500 Overcurrent and Short-Circuit Relay The short-circuit relays protects against faults causing high currents and the overcurrent relay protects against thermal damage Combining 2 relays is an economic solution, occupying less space in the switch panel littelfuse.com/t2500 T2500.0010 450 V 400 V 5 A Latching output, resetable T2500.0020 230 V 5 A Latching output, resetable T2500.0030 40 V 415 V 5 A Latching output, resetable T2500.0040 450 V 400 V 1 A Latching output, resetable T2500.0050 24 Vdc 5 A Latching output, resetable T2500.0060 230 V 5 A De-energized extra output relay T2500.0070 450 V 400 V 5 A De-energized extra output relay T2500.000 450 V 400 V 5 A De-energized extra output relay, latching outputs T2500.0090 40 V 415 V 5 A De-energized extra output relay T2500.0100 24 Vdc 1 A De-energized extra output relay T2500.0110 450 V 400 V 5 A De-energized extra output relay, latching short circuit output T2500.0120 24 Vdc 5 A De-energized extra output relay, de-energized relay 1, no internal power backup T2700 Power Relay Detects power levels for protection, control or monitoring and will protect against excessive active loads 15-150 x I N littelfuse.com/t2700 ORDERING NUMBER TERMINALS 1-3 TERMINALS 2-3 I N SUPPLY FUNCTION T2700.00 230 V 5 A L-N T2700.02 450 V 400 V 5 A L-L T2700.03 230 V 400 V 5 A L-L T2700.04 110 V 100 V 5 A L-L Normally energized output T2700-0 127 V 120 V 5 A L-N T2900 3-Phase Differential Relay Monitors current leakage in generators and measures the differential current of each of the 3 phases supply 0.04-0.4 x I N (0.1-1 sec. bridging terminals 1/19) littelfuse.com/t2900 ORDERING NUMBER TERMINALS 1-3 TERMINALS 2-3 I N T2900.0010 450 V 400 V 5 A T2900.0020 230 V 5 A T2900.0030 40 V 415 V 5 A T2900.0040 110 V 100 V 5 A Gross Automation 360 N. 126th St., Brookfield, WI 53005 Toll-Free: 77-26-3700 sales@grossautomation.com www.littelfusesales.com 2015 Littelfuse POWR-GARD Products Catalog 161

T3000 Relay monitor generators, busbars or other Combining 2 relays is an economic solution for monitoring both underfrequency and overfrquency in Overfrequency Level 45-65 Hz Underfrequency Level 45-65 Hz littelfuse.com/t3000 ORDERING NUMBER TERMINALS 1-3 TERMINALS 2-3 T3000.0010 230 V T3000.0020 450 V 400 V T3000.0030 110 V 100 V T3000.0040 40 V 415 V T3000.0050 127 V 120 V T3100 Voltage Relay Signals when voltage is out of its limits Consists of two, one for overvoltage and one for undervoltage monitoring Overvoltage level 100-120% Undervoltage Level 0-100% littelfuse.com/t3100 T3300 3-Phase Voltage Relay ORDERING NUMBER TERMINALS 1-3 TERMINALS 2-3 T3100.0010 230 V T3100.0020 450 V 400 V T3100.0030 110 V 100 V T3100.0040 40 V 415 V T3100.0060 127 V 120 V Signals when voltage is out of its limits Consists of two, one for overvoltage and one for undervoltage monitoring Overvoltage Level 100-120% Undervoltage Level 0-100% W 150 mm (5.9 ) littelfuse.com/t3300 ORDERING NUMBER TERMINALS 17-19, 21-23, 25-27 TERMINALS 1-19, 22-23, 26-27 T3300.0010 230 V T3300.0020 450 V 400 V T3300.0030 110 V 100 V T3300.0040 40 V 415 V Gross Automation 360 N. 126th St., Brookfield, WI 53005 Toll-Free: 77-26-3700 sales@grossautomation.com www.littelfusesales.com 162 2015 Littelfuse POWR-GARD Products Catalog