HDT1000 series ORIFLO METER. Multi-function Digital Flowmeter OUTLINE STANDARD SPECIFICATION FEATURES MAIN APPLICATIONS INDICATOR SPECIFICATION

Similar documents
CDT1000 Series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION

CDT1000 series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION

O-180/780 Series ORIFLO METER COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES GENERAL FEATURES MAIN APPLICATIONS

ORIFLO CONTENTS COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES INTEGRATED ORIFICE FLOWMETERS GENERAL FEATURES MAIN APPLICATIONS

O-180/780 Series ORIFLO METER COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES GENERAL FEATURES MAIN APPLICATIONS

R-101-E GLASS TUBE FLOWMETER BEST COST PERFORMANCE GENERAL STANDARD SPECIFICTION. Max. fluid press. MPa Meter size.

O-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

SRT1000 Series THERMAL FLOWMETER

STK2000/7400 Series. Flapper-type Flowmeter OUTLINE FEATURES PRINCIPLE STANDARD SPECIFICATIONS. Specifications of the metal measuring tube

AM-2000 series HYBRID FLOWMETER

STANDARD SPECIFICATIONS

AM9000 Series GENERAL FEATURES METAL TUBE VARIABLE AREA FLOWMETER

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

O-100 Series GLASS TUBE TYPE ORIFLOMETER BEST COST EFFECTIVE FLOW MEASUREMENT EVEN FOR LARGE SIZE LINES GENERAL STANDARD SPECIFICATION MODEL CODE

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

FT-1000/FP-1000 FLOAT TYPE TANK GAUGES SIMPLE, RELIABLE, COST EFFECTIVE. The FT-1000 or FP-1000 series is a mechanical level gauge with a float.

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

General Specifications

1000 Series MASSMAX. Coriolis Mass Flowmeter Straight Twin Tube OUTLINE FEATURES STANDARD SPECIFICATIONS. Fluid Specifications

Pressure Transmitters

Temperature Indicating Controller

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES MEASURING PRINCIPLE

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES

Electric Top-Guided Single-Seated Control Valves

Glass Tube Variable- Area Flow Meter (Series KA, KB, KC)

The Multivariable Air Flow Meter

RCM - Direct Reading Flowmeters

The Multivariable Air Flow Meter

Detector (for water measurement applications)

UL350 ULTRASONIC FLOWMETER CLAMP-ON TYPE OUTLINE FEATURES MEASUREMENT PRINCIPLE

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

WYECO. Y-Type Cylinder Actuated Valve. Model WY-C08YT-S

Top-Guided Single Seated Control Valves (Rating : ANSI 600 or Less)

FLOWMETER (SMALL CAPACITY) METER SIZE 80, 81

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Level Switch MPC2000 MPC2

Smart Displacement type Level Transmitter

2-Color Display High-Precision Digital Pressure Switch

1. Preface For best results, please refer to this manual before using this product. 2. Safety precautions Model Precautions DFS-1 The maximum pressure

KDM ARMORED FLOW METER & SWITCH

유량계전문제조업체. Electro Magnetic FLOWMETER

4 Note 1) Value for communications type. (PROFIBUS DP)

HN B G1/US B G2/US B G3

A6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM

High Pressure Service Cage type Double Seated Control Valves (Rating: ANSI 900 to 2500)

CONTROL VALVE STANDARD SPECIFICATION

Smart Pressure Transmitter

KEL DIFFERENTIAL PRESSURE FLOWMETERS

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

OVAL TURBO STEAM METER

FP-4000 Series FLOAT LEVEL SWITCH OUTLINE MAIN APPLICATIONS STANDARD SPECIFICATION

Orifice Flow Meter (Series KOP/KOE)

Differential Pressure Gauges (701P Series)

Pneumatically-Operated, Single-Seated Control Valve

SA FLOW METER & FLOW SWITCH (Proximity switches are used for small flow rate)

Ceramic Trim Angle Control Valves

Internet For latest information, PDF catalogs and operation manuals

Primary Pressure Regulating Valve Pressure Sustaining Valve Differential Pressure Regulating Valve

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

PNEUMATIC ON OFF GLOBE VALVE

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

UCM -04A/06A RoHS compliance

EDR-N8A CS Intelligent Absolute Pressure Transmitter STANDARD SPECIFICATIONS. Accuracy Material Code: Standard,316L Range Accuracy Code

Three Way Control Valves

F-2600 SERIES INLINE VORTEX FLOW METER

STANDARD SPECIFICATION STRAIGHT THROUGH TYPE BALL- VAVLE 301K SERIES

2-Color Display High-Precision Digital Pressure Switch

PMG MAGNETIC FLOWMETER

Thermal Mass Flow Meter (Series MST)

MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus

Paddle-wheel flow controller for On/Off control

2-Color Display Digital Flow Switch

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Differential Pressure Sensor

CV3000 Series Low-Noise Cage type Control Valve Model ACN

Product Catalog. Our Products. DCI Dynamic Instruments Website: dcidynamic.com

Thermal Gas Mass Flowmeter Series TMF-300

Paddle-wheel flow controller with optical principle for On/Off control

General Specifications

General Specifications

CONTROL VALVE STANDARD SPECIFICATION

F1000/F3000/F4000/F8000 Series

OBE (On-Board Electronics) Type Direct Operated Linear Servo Valves (Size: 01 & 03) LSVG-01-EH-*-**-**-10, LSVG-03EH-*-**-**-10/1006

Series 10-ZSE40A(F)/10-ISE40A

Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

CV3000 Series Pressure-Balanced Cage type Control Valve

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

PD3/PDV3-20A/25A/40A Series

3-colour / 2-screen display

Paddle-wheel flow controller for On/Off control

Metal tube variable area flowmeter for gases, liquids and steam

Series ITV1000/2000/3000

Low leakage Pressure Balanced Cage type Control Valves Model AC2

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Transcription:

ORIFO METER HDT series Multifunction Digital Flowmeter OUTINE HDT is a new series Oriflo meter combining orifice plate with multidigital indicator. HDT detects differential pressure exerted by flow velocity on the orifice plate and displays it digitally as flow rate. Available meter sizes range from 15m to 3mm dia. The principal applications are hot and cooling water, air flow measurement and so forth. FEATURES Excellent cost performance Flow rate measurement is possible at low cost for medium or large diameter pipes. Compact design The indicator part is very small and saves mounting space. Easy installation Available various process connections of Screw, Flange, and Wafer to meet all field possible requirements and for easy pipe installation. Applicable for both parallel and vertical pipes. Various functions of indicator Any type can be chosen out of the following: Battery type, Current output type (2wire 42mA DC), Alarm output type, Temperature sensor input type and onworks type Indicator part is interchangeable Easy to see because of large CD display MAIN APPICATIONS Air conditioner water and air line Cooling water line General process line in medium and large diameters Sewage disposal process Pure water device Fire pump performance test Blower performance test INDICATOR SPECIFICATION Refer to the DT series TECHNICA GUIDANCE TGEM125E for the details of digital indicator. STANDARD SPECIFICATION Measuring Fluid : iquid (equivalent to water) or Gas Max. Pressure : 2MPa Allowable diff. press. : 2kPa (Bias pressure) Temperature and Relative Humidity Fluid temperature : 1 to 7 Ambient Temp. : 1 to < 85%RH Storage Temp. : 2 to 6 < 85%RH (Without icing, without condensation) Meter size : 15mm to 3mm (3 to mm ; Consult factory for details) Flow range : Refer to [FOW RANGE] Process connection Screw connection : Rc (F) taper pipe thread NPT(F) [Meter size 15mm (1/2 ) to mm (4 )] Flange connection : JIS5K/1K/2K FF/RF ANSI/JIP 1/3 [Meter size 15mm (1/2 ) to 3mm (12 )] Wafer connection : JIS1K/2K ANSI/JIP 1/3 [Meter size 15mm (1/2 ) to 3mm (12 )] Accuracy : 3% F.S. (Std.) (Accuracy guarantee fluid temp. range 7~6 ) Measuring range : Flow rate from 1 to % of full scale ow cutoff : ess than 7% (Selectable :, 7, and 15%) Protection class : IP65 (JIS C 92) (Except the air introduction port at the bottom of housing.) Material : Refer to [MATERIA] Painting Measuring tube : Polyurethane painting (No painting in case of stainless steel) Indicator housing : Melamine resin painting Painting color Metering tube : Jade green (Munsell 7.5BG4/1.5) Indicator housing Front : Wine red (Munsell 1RP3/8) Rear : ight gray (Munsell N7.5) Installation posture : Front vertical installation TGF9752E MAY, 26

HDT ORIFO METER / Multifunction Digital Flowmeter Required straight run The upstream condition Upstream Downsteram 9 o elbow 1D 4D Fully opened valve 12D D : Pipe inside diameter Straight runs are calculated from orifice plate location. Indicator type function (All types with indicator) Type Battery type Current output type Alarm output A type Alarm output B type Temp. sensor input type onworks Type Function Battery drive, Indication only 42mA DC (2wire) 2 points 42mA DC 2 points Temp. input / indication Temp. input / Indication, Battery drive Applicable to on communication network Indication function Flow rate indication :31/2 digits CD (Height 18mm) : to 1999 (FFF appears in case of out of range) 11 segment bar graph Totalizer indication :71/2 digits CD (Height 5mm) : to 19999999 Indication interval :1s (Sampling.5 sec) Filter :,2,4,8,16,32s (Moving average) CD back light :Continue 1s after operation (Except current output type) Specification and function of each type 1) Battery type Battery :Alkali battery (R6) x 2 pcs. Battery life :Approx. 2 years at 23 Auto power off mode selectable ow Battery monitor as standard 2) Current output type Power supply :24V DC 1% Output :42mA DC (2wire) Max. load :6Ω Output accuracy :.5% F.S. at 23 Response :ess than 2 s (At filter setting ) 3) Alarm output A type Power Supply :24V DC 1% Power Consumption :ess than 25mA Alarm Output :Open Collector x 2 (Independent) oad :ess than 3V DC / 8mA Response :ess than 2 s (At Filter setting ) Alarm setting :Selectable (high / ow), Reset Span: Adjustable / Min. 1digit Output : 42mA DC Max. load :6Ω Output Accuracy :.5 %F.S.at 23 4) Alarm output B type Power Supply :24V DC 1% Power Consumption :ess than 25mA Alarm Output :Open Collector x 2 (Independent) oad :ess than 3V DC / 8mA Response :ess than 2 s (At Filter setting ) Alarm setting :Selectable (high / ow), Reset Span: Adjustable / Min. 1digit Connecting Temp. Sensor: PtΩ (3wire) (JIS C 164) Temp. Indication :1 to 8 Indication Interval :6 s Temp. Ind. Accuracy : 2 (Excluding sensor error) 5) Temperature sensor input type Following function is added to battery type Connecting temp. sensor :PtΩ (3wire) (JIS C 164) Temp. Indication :1 to 8 Indication interval :6 s Temp. indication accuracy: 2 (Excluding sensor error) 6) onworks type Applicable to on communication network. Communication with network devices by FTT1A Transceiver. Power Supply :24V AC 1% Power Consumption :ess than 8mA Transmission on Value :Flow rate and differential pressure (Convert the Indication value to on value) Response :ess than 2 s (At Filter setting ) The communication of each device is in accordance with definite procedure related to its on value. FTT1A can be connected by free topology and multi drop connection. Refer to [Function Profile] for detailed information Cable entry Type Cable entry Cable entry R Battery type Current output type Alarm output A type Alarm output B type Temperature sensor input type onworks type Acceptable cable outside diameter 3 8mm : Yes : No OPTION Totalizing indication Selection of totalizer function CODE : TZ Selection of Temp. indication unit : o F (Export Model) Temp. sensor input type only (Standard unit : ) CODE : TPF Protection cover (For indicator protection) CODE : HGC CAUTIONS ON INSTAATION Avoid direct rays and equip with a protection cover or install in the place which a direct rainstorm does not splash. (If protection cover is used, it may be difficult to read the display.) Protection cover RZ kpa m3/h cm3/h 2 TOKYO KEISO CO., TD. TGF9752E

HDT ORIFO METER / Multifunction Digital Flowmeter MATERIA Wetted parts Part Description Material class 1 Material class 2 Material class3 Screw connection 15 25mm SCS14 15 mm SCS14 15 mm SCS14 32 mm FCD4 65 mm SUS34 65 mm SUS316 Metering tube Flange connection SGP SS4 SUS34 SUS316 25,4 1mm 25,4 1mm 25,4 1mm SCS14 SCS14 Wafer connection for JIS1K for JIS1K for JIS1K SCS14 Others SS4 Others SUS34 Others SUS316 Orifice plate SUS34 SUS34 SUS316 Body SCS14 SCS14 SCS14 Isolation valve Shaft SUS316 SUS316 SUS316 O ring NBR or Viton NBR or Viton NBR or Viton Diaphragm SUS316 Indicator Body SUS316 O ring Viton Drain hole seal Alumina ceramics Indicator body Aluminum alloy FOW RANGE Full scale range Meter size iquid m 3 /h Gas m 3 /h (nor) (Density 1.g/cm 3, Viscosity 1.mPa s) ( 1atm Air) Min. Max. Min. Max. 15mm.23 2.3 3.4 37 2mm.31 5.2 4.6 85 25mm.45 8.8 5.5 14 32mm.51 14.7 6.7 23 4mm.69 19 8.6 32 mm.75 32 1 52 65mm 1.2 53 15 86 8mm 1.7 74 21 12 mm 2.9 127 35 2 125mm 4.4 196 54 32 1mm 6.2 276 8 4 2mm 11 48 14 78 2mm 17 74 21 12 3mm 24 16 3 172 Full scale ranges of upper table are for liquid application equivalent to water (Density 1.g/cm 3 and Viscosity 1.mPa s). If actual fluid condition has different values, conversion calculation is required per following formula: Qw =Qx γ Qw : Water converted flow rate Q : Flow rate of actual fluid γ : Density of actual fluid (g/cm 3 ) The calculation of figures in the above flow range table has been made on the premises that SGP, a JIS code name for a carbon steel pipe for ordinary piping, is used for main pipes. In case of pipes other than SGP, multiply the above liquid quantity by (the inner diameter of a pipe used the inner diameter of a SGP pipe) 2. Full scale ranges for gas of upper table are shown by the flow rate of AIR, at, 1atm. If actual fluid condition has different value, conversion caluculation is required per following formula. Conversion calculation QA= Q x Cγ x Ct x Cp QA : Converted Air flow Q : Flow rate of Actual Gas Cγ :Cγ= γ/1.293 [γ=density of the Gas, kg/cm 3 (nor)] Ct : Ct= (273t)/273 (t=operating temp., ) Cp : Cp=.113/ (.113p) (p=operating press, MPa) TGF9752E TOKYO KEISO CO., TD. 3

HDT ORIFO METER / Multifunction Digital Flowmeter OUTINE DIMENSION Screw connection type Material class 1 (Meter size 15 mm) Material class 2 / 3 (Meter size 15 mm) [Installation in the case of Gas] Each connection in common RZ k Pa o C (A) measurement. An indicator is fixed at the top of isolation valve in case of gas measurement. [Dimension of indicator] 72 93 RZ k Pa 21 24 (93) 16 (84) (66) 48 4 35 28 35 28 35 Meter Material of metering tube FCD4 Material of metering tube SCS14 size (A) Mass(kg) A Mass(kg) 15mm 7 13 1.8 2mm 7 132 1.9 25mm 7 136 2. 32mm 74 144 2.2 74 144 2.2 4mm 85 147 2.4 85 147 2.3 mm 9 155 2.5 9 155 2.8 65mm 164 3.2 8mm 11 173 3.7 mm 12 186 5.2 Cable entry Cable entry R Screw connection type Material class 2 / 3 (Meter size 65 mm) RZ k Pa o C (A) measurement. An indicator is fixed at the top of isolation valve in case of gas measurement. Meter size (A) Mass (kg) 65mm 12 199 4.2 8mm 12 27 4.5 mm 16 222 7.7 4 TOKYO KEISO CO., TD. TGF9752E

HDT ORIFO METER / Multifunction Digital Flowmeter Flange connection type RZ k Pa (A) measurement. An indicator is fixed at the top of isolation valve in case of gas measurement. Meter size (A) Mass (kg)* Meter size (A) Mass (kg)* 15mm 54 167 3.8 8mm 54 21 12 2mm 54 17 4.4 mm 54 214 16 25mm 54 174 5.6 125mm 54 226 2 32mm 54 178 6.9 1mm 54 239 27 4mm 54 181 7.3 2mm 54 265 35 mm 54 187 8.7 2mm 54 29 65mm 54 195 11.6 3mm 54 316 61 *Mass is for case of JIS1K flange. Wafer connection type RZ k Pa (A) measurement. An indicator is fixed at the top pf isolation valve in case of gas measurement. Meter size (A)* Mass (kg)* Meter size (A)* Mass (kg)* 15mm 186 2.9 8mm 227 3.5 2mm 188 3. mm 239 4. 25mm 197 3.4 125mm 255 5. 32mm 199 3.8 1mm 27 6. 4mm 24 2.7 2mm 292 13 mm 212 3. 2mm 323 18 65mm 222 3.3 3mm 346 2 *A ength and Mass are for case of JIF1K flange. TGF9752E TOKYO KEISO CO., TD. 5

3 3 HDT ORIFO METER / Multifunction Digital Flowmeter Indicator separation version Fitting (A) 8 H (Std.) 3/8" piping 3/8" Union measurement. An indicator is fixed at the top of isolation valve in case of gas measurement RZ k Pa m /h cm /h Fitting (B) Indicator can be located separately from process by using extension piping for easy observation of indication. Extension piping length is mm (std). (Extension piping length is available on request) Part description Material class1 Material class2 Material class3 Fitting (A) / (B) SCS14 SCS14 SCS14 3/8B Pipe SGP (white) SUS34 SUS316 3/8B Union FCMB SUS34 SUS316 Refer to MATERIA table for the combination of material class 1,2, and 3. WIRING DIAGRAM [Current output type] 42mA DC24V Receiver [Alarm output A type] Alarm output (1)/(2) : Open collector Max. 3V DC/8mA ANA OUT DC24V Alarm output (1) Alarm output (2) 42mA Receiver [Alarm output B type] [Temp. sensor input type] [onworks Type] Alarm output (1)/(2) : Open collector Max. 3V DC/8mA b DC24V Alarm output (1) Alarm output (2) b B A PtΩ Black Red White blue ~ AC24V NETB NETA Host device B A PtΩ 6 TOKYO KEISO CO., TD. TGF9752E

HDT ORIFO METER / Multifunction Digital Flowmeter CODE 1 Material class 1 Material 2 Material class 2 Refer to MATERIA table 3 Material class 3 Indicator installation Oring for isolation valve Model code Description Note HDT1 A / Meter 15 15mm size 3 3mm SRC Thread connection Rc 1 With isolation valve 2 Indicator separation version N F NBR Viton 1 Bottom to Top 6 eft to Right Flow direction 7 Right to eft 8 Top to Bottom Flow range*1 Flow range code Manufacturer choice 4 Battery type Battery drive 5 Current output type 42mA DC (2wire) Indicator type 6 Alarm output A type 2 points 42mA DC 7 Alarm output B type 2 points Temp input / indication 8 Temp.sensor input type Temp. input Indication, Battery drive 9 onworks type onworks available For iquid Application G For Gas Version A Version code Option*2 Additional function SNP Thread connection NPT J1F JIS1K FF Flange J1R JIS1K RF Flange J2F JIS2K FF Flange J2R JIS2K RF Flange J5F JIS5K FF Flange J5R JIS5K RF Flange A1R ANSI 1 Flange A3R ANSI 3 Flange P1R JPI 1 Flange P3R JPI 3 Flange WJ1 Wafer (JIS1K) WJ2 Wafer (JIS2K) WJ5 Wafer (JIS5K) WA1 Wafer (ANSI 1) WA3 Wafer (ANSI 3) WP1 Wafer (JPI 1) WP2 Wafer (JPI 3) ZZZ Others /TZ /TPF /HGC Totalization indicator o F indication With protection cover at display part (Blank) Not provided Temp. indication type and in case of export are available. Not necessary if abovementioned code is available. /Z Provided *1 Flow range code is selected by factory in accordance with the specified flow rate and diameter. *2 Insert / between each code when the plural codes are selected. Code example 1: [In case optional code is not selected.] 25mm diameter. Thread connection Rc. Material class 1. With isolation valve. NBR for Oring for isolation valve. Flow direction: eft to right. Battery operated type. For liquid application. HDT125SRC1N6***4A Code example 2: [In case all of the possible optional codes are seleclted.] mm diameter. JIS1K FF flange connection. Material class 2. With isolation valve. NBR for Oring for isolation valve. Flow direction: Top to bottom. Temperature sensing input type For liquid application. Integrating indication added. Temperature indication in o F. With protection cover for indicator. HDT1JIF21N8***8A/TZ/TPF/HGC Code example 3: [In case the face to face dimension is specified.] 8mm diameter. JIS5K FF flange connection. Material class 3. With isolation valve. NBR for Oring for isolation valve. Flow direction: Right to left. Current output type. For liquid application. Integrating indication added. =6 is specified instead of =54. HDT18J5F31N7***5A/TZ/Z (=6) When the face to face dimension is specified as seen in the above Code Example 3, it will be Special specification, and the last letter of model code will be Z in case of such special specification as not mentioned in the above model code. TGF9752E TOKYO KEISO CO., TD. 7

o HDT ORIFO METER / Multifunction Digital Flowmeter CONSTRUCTION Oring (P38) Oring (P8) Air release valve (4 pcs) Air release plug (4 pcs) Knurl Bolt, Nut M5x2 (4 pcs) SCS14 SHUT Fixing by screw Isolation valve Blind plug Hexagon socket head cap screws (4 pcs) Indicator kpa C Rear view of indicator PREPARATION OF MEASUREMENT In case the fluid is liquid,eliminate the air, and for the gas application, eliminate the drain in according to the HDT Instruction manual IMF972. ORDERING INFORMATION 1. 2. FU SCAE 3. FUID NAME 4. TEMPERATURE (Nor. Max. ) 5. PRESSURE (Nor. Max. ) 6. DENSITY 7. VISCOSITY * Specification is subject to change without notice. Head Office : Shiba Toho Building, 1 7 24 Shibakoen, Minatoku, Tokyo 15 8558 Tel : 3 3431 1625 (KEY) ; Fax : 3 3433 4922 email : overseas.sales@tokyokeiso.co.jp ; UR : http://www.tokyokeiso.co.jp 8 TGF9752E