KEY PARAMETERS FOR THE PERFORMANCE OF IMPACTION-PIN NOZZLES USED IN INLET FOGGING OF GAS TURBINE ENGINES

Similar documents
SPRAY INTERACTION AND DROPLET COALESCENCE IN TURBULENT AIR-FLOW. AN EXPERIMENTAL STUDY WITH APPLICATION TO GAS TURBINE HIGH FOGGING

Impact of Fuels on Performance and Efficiency of Gas Turbine Power Plants

Cold Flow PIV and Spray Visualization Experiments Applied to the Development of ALSTOM Dual Fuel Gas Turbine Burners

COMPARISON OF BREAKUP MODELS IN SIMULATION OF SPRAY DEVELOPMENT IN DIRECT INJECTION SI ENGINE

Paper ID ICLASS The Spray Nozzle Geometry Design on the Spray Behavior Including Spray Penetration and SMD Distribution

INFLUENCE OF THE NUMBER OF NOZZLE HOLES ON THE UNBURNED FUEL IN DIESEL ENGINE

Increase Turbine Output. Gas Turbine Inlet Cooling

FLAME COOLING AND RESIDENCE TIME EFFECT ON NO x AND CO EMISSION IN A GAS TURBINE COMBUSTOR

Spray Characteristics of Diesel Fuel Containing Dissolved CO 2

Spray Characteristics of an Airblast Atomizer on Biodiesel Blends

Optical Techniques in Gasoline Engine Performance and Emissions Development Injector Spray Visualisation

Spray Characteristics of Diesel Fuel from Non - Circular Orifices

Design Impact of Wurster Coating Spray Nozzles

Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

Influence of Cylinder Bore Volume on Pressure Pulsations in a Hermetic Reciprocating Compressor

Paper ID ICLASS EXPERIMENTAL INVESTIGATION OF SPRAY IMPINGEMENT ON A RAPIDLY ROTATING CYLINDER WALL

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

Impacts of Short Tube Orifice Flow and Geometrical Parameters on Flow Discharge Coefficient Characteristics

Numerical Simulation of the Effect of 3D Needle Movement on Cavitation and Spray Formation in a Diesel Injector

CFD Simulation of Dry Low Nox Turbogas Combustion System

SPRAY CHARACTERISTICS OF A MULTI-CIRCULAR JET PLATE IN AN AIR-ASSISTED ATOMIZER USING SCHLIEREN PHOTOGRAPHY

Improvement of Spray Characteristics for Direct Injection Diesel Engine by Cavitation in Nozzle Holes

An Experimental and Numerical Investigation on Characteristics of Methanol and Ethanol Sprays from a Multi-hole DISI Injector

Spray and atomization of diesel and biofuels using a single-hole nozzle. North Carolina State University Raleigh, NC, 27695

Characteristics of Spray from a GDI Fuel Injector Using TRF Gasoline Fuel Surrogate. North Carolina State University Raleigh, NC, USA

STUDY ON COMPACT HEAT EXCHANGER FOR VEHICULAR GAS TURBINE ENGINE

The spray characteristic of gas-liquid coaxial swirl injector by experiment

Simulation Analysis Spray of the Butanol and Diesel Fuel Mixed with Injection Pressure and Air Flow Intensity

Influence of Micro-Bubbles within Ejected Liquid on Behavior of Cavitating Flow inside Nozzle Hole and Liquid Jet Atomization

Enhance the Performance of Heat Exchanger with Twisted Tape Insert: A Review

Effect of cavitation in cylindrical and twodimensional nozzles on liquid jet formation

EXPERIMENTAL INVESTIGATION OF THE FLOWFIELD OF DUCT FLOW WITH AN INCLINED JET INJECTION DIFFERENCE BETWEEN FLOWFIELDS WITH AND WITHOUT A GUIDE VANE

Improvement of Atomization Characteristics of Spray by Multi-Hole Nozzle for Pressure Atomized Type Injector

High Pressure Spray Characterization of Vegetable Oils

Numerical Simulation on Erosion of Drain Valve Liangliang Xu1,a, Zhengdong Wang2,b, Xinhai Yu3,c, Cong Zeng4,d

AUTOMOTIVE TESTING AND OPTIMIZATION. Tools for designing tomorrow's vehicles

Comparing FEM Transfer Matrix Simulated Compressor Plenum Pressure Pulsations to Measured Pressure Pulsations and to CFD Results

in ultra-low NOx lean combustion grid plate

Effect of Compressor Inlet Temperature on Cycle Performance for a Supercritical Carbon Dioxide Brayton Cycle

Use of Flow Network Modeling for the Design of an Intricate Cooling Manifold

Effects of Dilution Flow Balance and Double-wall Liner on NOx Emission in Aircraft Gas Turbine Engine Combustors

Study on Flow Fields in Variable Area Nozzles for Radial Turbines

Comparison of Measured PFI Spray Characterizations of E85 and N-heptane Fuels for a Flex-Fuel Vehicle

Right Angle Nozzle Assembly

Lube Oil Vent Mist Eliminator

Hydraulic Drive Head Performance Curves For Prediction of Helical Pile Capacity

DIESEL SPRAY DEVELOPMENT FROM VCO NOZZLES WITH COMMON-RAIL

Institut für Thermische Strömungsmaschinen. PDA Measurements of the Stationary Reacting Flow

Design and Test of Transonic Compressor Rotor with Tandem Cascade

Combustion Properties of Alternative Liquid Fuels

[Rao, 4(7): July, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Numerical Investigation of the Effect of Excess Air and Thermal Power Variation in a Liquid Fuelled Boiler

SWIRL MEASURING EQUIPMENT FOR DIRECT INJECTION DIESEL ENGINE

VELOCITY CONTROL TECHNOLOGY DESUPERHEATERS

STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE

Development of Large Scale Recuperator for Gas Turbine

WM 07 Conference, February 25 March 1, 2007, Tucson, AZ. Evaluation of Glass Fiber Hepa Filters as a Function of Media Velocity

Investigation of converging slot-hole geometry for film cooling of gas turbine blades

CFD Analyses of the Experimental Setup of a Slinger Combustor

5. Combustion of liquid fuels. 5.1 Atomization of fuel

Crankcase scavenging.

Effect of concave plug shape of a control valve on the fluid flow characteristics using computational fluid dynamics

Effect of Injection Pressures on GDI Spray and Atomization of Different Fuels

Reduction of Oil Discharge for Rolling Piston Compressor Using CO2 Refrigerant

CHAPTER 1. Introduction and Literature Review

ATOMIZATION OF LIQUID FUELS COMBUSTION AND FUELS

Enhanced Heat Transfer Surface Development for Exterior Tube Surfaces

Parametric Study on Performance Characteristics of Wave Rotor Topped Gas Turbines

Design of Piston Ring Surface Treatment for Reducing Lubricating Oil Consumption

Turbo boost. ACTUS is ABB s new simulation software for large turbocharged combustion engines

Paper ID ICLASS MULTIPLE HOLLOW-CONE-LIKE SPRAY FORMATION BY CONTROLLING INTERNAL FLOW OF MULTIPLE HOLE NOZZLES

Performance of VAV Parallel Fan-Powered Terminal Units: Experimental Results and Models

Research on vibration reduction of multiple parallel gear shafts with ISFD

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

FLUID FLOW. Introduction

Australian Journal of Basic and Applied Sciences

Investigation of Direct-Injection via Micro-Porous Injector Nozzle

Combustion characteristics of n-heptane droplets in a horizontal small quartz tube

CAV2001:sessionA

Simulation Studies on the Effect of Porous Twisted Plate Inserts on the Performance of Fire Tube Steam Packaged Boiler

Experimental Study of Heat Transfer Augmentation in Concentric Tube Heat Exchanger with Different Twist Ratio of Perforated Twisted Tape Inserts

Pulsation dampers for combustion engines

YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER

Analysis of Torsional Vibration in Elliptical Gears

Nacelle Chine Installation Based on Wind-Tunnel Test Using Efficient Global Optimization

Clearance Loss Analysis in Linear Compressor with CFD Method

Preliminary Design of a LSA Aircraft Using Wind Tunnel Tests

Design Rules and Issues with Respect to Rocket Based Combined Cycles

Ignition Improvements to Support High-efficiency Natural Gas Combustion

A MATHEMATICAL MODEL OF THE CORRUGATED PLATES PACKING OIL-WATER SEPARATOR

KINEMATIC DESIGN OF LIFT-TIPPING MECHANISM FOR SMALL SOLID WASTE COLLECTION TRUCK

Experiment No.3: Flow through orifice meter. Background and Theory

ADVANCES in NATURAL and APPLIED SCIENCES

Simulation of the Mixture Preparation for an SI Engine using Multi-Component Fuels

Particle size and distribution of oil mist from cooking equipments in electrical commercial kitchens

Numerical Study on the Flow Characteristics of a Solenoid Valve for Industrial Applications

Aerodynamically induced power loss in hard disk drives

DEVELOPMENT OF AN INTERNAL MIXING TWO-FLUID NOZZLE BY SYSTEMATIC VARIATION OF INTERNAL PARTS

Proposal to establish a laboratory for combustion studies

PARTICLE ATTRITION MEASUREMENTS USING A JET CUP

Transcription:

Proceedings of GT0 ASME Turbo Expo 0: Power for Land, Sea and Air June 6-9, 0, Reno-Tahoe, Nevada, USA GT0-68346 KEY PARAMETERS FOR THE PERFORMANCE OF IMPACTION-PIN NOZZLES USED IN INLET FOGGING OF GAS TURBINE ENGINES Mustapha A. Chaker Gas Turbine Division Mee Industries Inc. Monrovia, CA, 916 USA Abstract Application of inlet air fogging to gas turbine engines for power augmentation, has become common practice, with more than a 00 installations worldwide including a large number of advanced gas turbines. In this paper an experimental investigation and empirical analysis of key operating parameters on the performance of impaction pin nozzles will be investigated. To this date no such correlation is available for impaction pin nozzles, which are currently used in about 7% of this type of applications. The correlations are developed from a series of experiments conducted in a wind tunnel equipped with the Malvern Spraytec droplet size measurement system. The conducted analysis covered a wide range of the relevant parameters. Mainly the water flow rate from the nozzle orifice was (0.00126 l.s -1 to 0.00063 l.s -1 : 0.02 gpm to 0.1 gpm), the operating pressure was (34. bars to 4.1 bars: 00 psi to 00 psi), the airflow velocity was (1. m.s -1 to 1.2 m.s -1 : 29 fpm to 00 fpm), the distance between the nozzle orifice and the location of measurement was (0.0127m to 0.08 m: 0. to ). Other parameters such as the plume spray cone angle and the surrounding ambient psychrometric conditions, which may affect the droplet size for impaction pin nozzles is also discussed. Introduction and Background Gas Turbine output is significantly impacted by the temperature of the ambient air, with the power output dropping by 0.4% to 0.90% for every 1 C (1.8 F) ris e in ambient temperature. One approach to overcome the loss of gas turbine power output during periods of high ambient temperature (high demand period) is to cool the inlet air. While there are several inlet air cooling technologies available, high pressure inlet fogging has become increasingly popular over the past decade due to its low cost and its effective power augmentation. A direct evaporation effect is derived by using fog droplets generated by high-pressure pumps and atomi z- ing nozzles installed in the inlet duct downstream of the inlet air filters. The fog evaporates in the inlet duct and cools the air down to the wet bulb temperature. A review of the basic principles of fogging technology can be found in Chaker and al [1, 2, 3, 4], Meher- Homji and Mee [, 6], and Bhargava and al [7]. Early papers on fog intercooling and wet compression started to appear in the late 1940s and include Hill [8], and Utamura et al [9]. There are two types of nozzles commonly used in inlet fogging systems: impaction pin nozzles and swirl jet nozzles. In both types, the difference in nozzles configurations may lead to differences in the atomization process and consequently in droplet sizes. It is therefore important to provide all details regarding the nozzles under test. This paper studies the behavior of impaction pin nozzles designed and implemented by Mee Industries in various gas turbine inlet fogging applications as shown in Figure 1. Due to the use of swirl nozzles in some applications such as the atomization of fuel in gas turbine combustors, there are a number of studies characterizing this type of nozzles and summarized by Lefebvre []. His work includes a number of empirical formulas regarding the parameters which influence the size of the droplet from this type of nozzles. Several papers have been published to measure the droplet size from impaction pin nozzles [11,12]. Ho w- ever, to our knowledge, no paper exists in the open literature which provides empirical relations of droplet size as a function of critical parameters affecting it. These equations are very useful in showing the impor- Copyright 0 by ASME 1

tance of each parameter and gives the users a tool in order to estimate rapidly the droplet size based on the value of the applied experimental parameters. This paper makes a systematic study and analysis of the different parameters that influence the droplet size and provides an empirical correlation between the droplet size and each of these parameters. 0.0216 m Experimental Setup Figure 1, Impaction pin nozzle In order to measure the droplets size in conditions similar to those found in gas turbine inlet ducts, a variable speed wind tunnel was built, as shown in Figure 2. Nozzles Manifold Airflow velocity sensors 0.0074 m 0.0061 m 0.0081 m orifice nozzles. In the exp erimental setup, a variablespeed-drive, positive-displacement, ceramic-plunger pump is used to generate water pressures up to 7 bars (00 psi). The wind tunnel is equipped with a high-speed data acquisition system, which consists of a DAS 10 board with up to 16 input channels and 2 output channels. Daisy Lab software was used to manage the data acquisition. The DAS 10 monitors: Temperature and Relative Humidity of the air in several locations Air velocities Water flow The position of the sensors in the duct is shown in Figure 2 and Figure 3. Droplet size measurements, at different locations in the spray plume and for different airflow velocities, and operating pressures were done with nozzles located in the constricted section of the duct, where the highest airflow velocities are attainable. Measurements were taken at different locations in the spray plume using a Malvern Spraytec RTS114 laser particle analyzer, as shown in Figure 3. The Malvern system is based on a laser diffraction technique [13, 14]. This is a spatial sampling system; consequently it allows the sampling of a large number of droplets instantaneously with a frequency up to 0 Hz. Pump 7 Flow Meter 8Control Valve Filter 3 2 Deionized water tank 4! Sensors Spraytec 1 Water Inlet PLC 9 c Fan a a b d e PC Nozzles Fog Droplet Filter Data Acquisition System Figure 3, Wind Tunnel experimental setup Temperature and RH sensors Spraytec Figure 2, 11 m long 2 m.s -1 velocity wind tunnel A brief description of the wind tunnel is given below and more information regarding its configuration and instrumentation may be found in Chaker [1,3]. Fog is generated in the wind tunnel by forcing highpressure, filtered and deionized water through the small A nozzle manifold, installed at the inlet of the duct, was turned off when measurements were taken at amb i- ent conditions. For measurements with a saturated airflow these nozzles were turned on, Figure 4, and a fog droplet filter was used, as shown in Figure 3, to remove any un-evaporated droplets. Droplet size measurement locations is shown in Figure. 2 Copyright 0 by ASME

Figure 4, Fog nozzles manifold droplets size: the first is the Sauter Mean Diameter (SMD) or D 32 which gives a droplet diameter that represents the ratio of volume to surface area of all the drops in the spray plume and, consequently is important in showing the evaporation rate which occurs at the droplet-air interface. The second is DV90, which is a droplet diameter where 90% of the volume of water in the fog is made up of drops with diameters smaller than or equal to the given diameter. A small DV90 diameter indicates that a very small volume of larger droplets is produced. That minimizes any potential erosion effects on compressor components should these droplets be carried over into the compressor. Either D 32 or DV90 may be written as function of the above-cited most important parameters following the equation: Z R (1) DP m& D Diameter = κ DP V µ w π w Where k is constant of proportionality, m& w is the water flow rate in liter per second, D is the distance between the nozzle orifice and the measurement position (m), w is the differential pressure applied on the liquid (bar), and V a is the airflow velocity (m.s -1 ). µ, δ, π, and ω are power constants. δ ϖ a Figure, Droplet size measurement in the wind tunnel Experimental Results The Spraytec unit outputs a value for Concentration Volume (CV). The results from each measurement position are based on the relative mass flow of water at that particular position and use the concentration volume value as a weighing coefficient. This technique mitigated errors that would have resulted from the fact that droplets in the center of the spray plume tend to be much smaller than droplets at the edges of the plume, while mass flow is much greater at the edges. The most important variables that affect the water droplet size produced by impaction pin nozzles are: the water supply pressure, the airflow velocity in which the water is atomized, the flow rate of the water from each nozzle, the distance between the measurement position and the nozzle s orifice. Other parameters, namely the plume cone angle and consequently the width of the plume, as well as the ambient psychrometric conditions, have less impact on droplet size. Their influence will be analyzed in later sections. Two characteristic diameters, employed in the gas turbine inlet air fogging industry, were used to study the 1. Effect of applied pressure: Figure 6 shows the effect of the operating pressure on the droplet size for different airflow velocities (from 1. m.s -1 to 1.2 m.s -1 ). It shows that as the operating pressure increases droplet size decreases. This decrease is important when the water is under an increasing operating pressure from 34. bars to 138 bars (a nozzle is typically operated at 138 bars in gas turbine inlet air fogging), however becomes insignificant when the operating pressure increases from 138 bars to 7 bars. The variation of DV90 and D 32 as function of the applied pressure follows the empirical formulas: 0.16 D (2) DV 90 P 0.23 D (3) D 32 P From Figure 6, we can also see that the droplet size decreases when we increase the airflow velocity. Figure 7 shows this variation at diffe rent operating pressures. 3 Copyright 0 by ASME

Droplet size (microns) 3 2 1 ` Measurements made at ambient conditions, where fast evaporation of smallest droplets occurs, and at saturated air conditions, where no droplet evaporation occurs, exhibit no difference in size increase due to this coalescence phenomenon. The variation of DV90 and D 32 as function of airflow velocity follows the empirical formulas: 0.14 (4) 3 DV 90 V a 0.11 () D 32 V a 2 0 7 0 12 17 0 22 Operating Pressure (bars) Dv90 (8.3 m/s) D32 (3.1 m/s) D32 (14.8 m/s) DV90 (3.1 m/s) D32 (1. m/s) D32 (8.3 m/s) DV90 (1. m/s) DV90 (14.8 m/s) Figure 6, Variation of droplet size as a function of the operating pressure and the location of the measurement in the spray plume. The distance between the nozzle orifice and the measurement position is 0.07 m Droplet size (microns) 2 1 1 4 7 13 16 Airflow Velocity (m.s -1 ) 2. Effect of airflow velocity: The airflow velocity was varied from 0.46 m.s -1 to 1.24 m.s -1. As can be seen in Figure 7, a decrease in droplet size occurs as the airflow velocity increases. This decrease is important between 0.46 m.s -1 and m.s -1 which is the typical airflow velocity at the location of nozzle manifolds installed in gas turbine inlet ducts upstream of the silencer. For the other nozzle manifolds position, downstream of the silencer with an airflow velocity varying between m.s -1 and m.s -1 depending on the gas turbine inlet duct configurations, the decrease in droplet size is much smaller and eventually levels out. In still air, and close to the nozzle orifice where the density of the droplets is high, a coalescence phenomenon may occur due to the high probability of collision between droplets of different sizes, and therefore different penetration velocities [4]. In high-velocity air streams the coalescence effect is greatly diminished as the airflow acts to separate droplets of different sizes, thus reducing the potential for collis ion. D32 (34 bars) D32 (138 bars) DV90 (34 bars) DV90 (138 bars) D32 (69 bars) D32 (7 bars) DV90 (69 bars) DV90 (7 bars) Figure 7, Variation of the droplets size as function of the airflow velocity, at C and 40% RH. The distance between the nozzle orifice and the measurement position is 0.07 m 3. Effect of the measurement distance By increasing the distance between the nozzle s orifice and the measurement position, an increase in droplet size may occur due to two reasons: The first is due to the coalescence and the second is due to the fast evaporation of the smallest droplets. Figure 8 shows the effect of the measurement distance between the nozzle orifice and the position of measurement on the droplet sizes. The upper two lines on the chart show the DV90 diameters, while the lower two lines show the D 32 diameters. In studying these 4 Copyright 0 by ASME

curves, one can see that the dashed lines (which representing the droplet size under non-saturated conditions), start to separate away from the solid lines (which representing the droplet size under dry air conditions), as the fog moves away from the nozzle orifice. That separation shows the very small effect of evaporation. In order to experimentally quantify the effect of rapid small droplet evaporation, measurements were taken at two airflow velocities, 3 m.s -1 and 13 m.s -1 (90 fpm and 260 fpm), and for two sets of air conditions: C (86 F) with 40% RH represented by dashed lines and defined as ambient in the chart, and C (68 F) with close to 0% RH represented by the solid lines and defined as saturated. The results of the experiments (Figure 8) show that the effect due to coalescence is much higher than that due to evaporation for the given distances of measurement. Figure 8 shows also the effect of the airflow velocity on the reduction of the coalescence effect. At 13 m.s -1 (the blue lines) the coalescence leads to an increase of DV90 of 4 microns where as for an airflow velocity of 3 m.s -1 (the green lines) the increase is 8 microns due to higher coalescence. The difference in droplet size increases also with increasing distance of measurement. D 32 behaves similarly to DV90. The variation of DV90 and D 32 as function of the distance between the nozzle orifice and the measurement position follows the empirical fo rmulas: 0.14 DV90 D (6) Diameter (microns) 2 1 0 0.13 D32 D (7) 0.01 0.06 0.11 0.16 0.21 Axial distance from the nozzle (m) D32-Amb-3 m/s D32-Sat-3 m/s D32-Amb-13 m/s D32-Sat-13 m/s Dv90-Amb-3 m/s Dv90-Sat-3 m/s Dv90-Amb-13 m/s Dv90-Sat-13 m/s Figure 8, Effect of ambient humidity on droplet size at different axial distances from the nozzle at 38 bars (00 psi) pressure 4. Effect of flow rate on droplet size Figure 9 shows the effect of the flow rate on the droplet size for different airflow velocities and distances from the nozzles orifice. It confirms that within our range of flow rate, the droplet size decreases when airflow velocity increases, and the droplet size decreases when the distance the distance between the measurement position and the nozzles orifice decreases. The variation of the droplet size and the flow rate may be correlated as follows: Droplet size (microns) 40 3 2 1 0 DV D m& (8) 0.23 90 w & 0.31 32 m w (9) Operating Pressure: 00 psi (138 bars) 0.00 0.002 0.0040 0.00 0.0070 Flow Rate (l.s -1 ) D32, 0.07m, 3 m/s DV90, 0.07m, 3 m/s D32, 0.07m, 13 m/s DV90, 0.07m, 13 m/s D32, 0.2m, 3 m/s DV90, 0.2m, 3 m/s D32, 0.2m, 13 m/s DV90, 0.2m, 13 m/s Figure 9, Effect of flow rate on droplet size. Effect of the plume cone angle The major reason for droplets coalescence within the plume is due to the high density of droplets close to the nozzle orifice. The collision between droplets in this region leads in general to their coalescence or bouncing because of a low Weber number [2]. By increasing the cone angle of the plume (by modifying the configura- Copyright 0 by ASME

tion of the nozzle) and consequently its width, the density of the droplets in the dense area decreases. Two nozzles which operate at the same experimental conditions were tested (Figure ) at 0.2 m from the nozzle orifices and for an airflow velocity of 0.2 m.s -1. The first one had an initial plume width (at this distance) of 0.17 m (Red Plain circle), and the second had an initial plume width of 0.13 m (Red empty circle). As can be seen in Figure, with the increase of airflow velocity, the plume width decreases from 0.17 m to 0.1 m for the largest plume, and from 0.13 m to 0.09 m for the smallest plume. At an airflow velocity of 0.2 m.s-1, D 32 (blue lines) for both plumes has the same value while DV90 (Green lines) for the smallest plume has around 7 microns more than the one for the largest plume (size is around twice in volume). With the increase in airflow velocity, D 32 decreases approximately in the same way for both plumes, while the decrease in DV90 is less important for the smallest plume. DV90 of both plumes decrease to around microns at an airflow velocity of 13 m.s -1. Discussion and Conclusion The combination of the experiments described above leads to the development of new empirical correlations between the Sauter Mean Diameter (D 32 ) and DV90 and the different parameters of influence, within the range of experimental values specified above. These empirical equations are: 0.23 0.14 0.16 0.14 DV 90 m& w D DP Va () 0.31 0.13 0.23 11 D32 m& w D DP Va (11) While the results of these empirical correlations give values close to the measured ones, more experiments need to be conducted to incorporate the effect of other parameters and to increase the precision and the range of the experimental values. This paper provides new tools which may be used by gas turbine inlet air fogging users to estimate the droplet size from impaction pin type nozzles. Droplet Size (microns) 4 40 3 2 1 0 Effect of Plume width on Droplet Size 0 1 17 16 1 14 13 12 11 Airflow Velocity (m.s -1 ) D32, Large plume DV90 Small Plume D32, Small Plume DV90, Large Plume Large Plume Width 9 8 Small Plume Width Plume Width (cm) Figure, Effect of plume width on droplet size as function of airflow velocity More experiments have to done to incorporate the effect of the plume size in the empirical formula given below. NOMENCLATURE CV D DAS DV90 K Concentration Volume (ppm) Distance between the nozzle Orifice and the measurement location (m) Data Acquisition System Droplet size number (µm) Constant of proportionality m& Water flow (l.s -1 ) P Operating pressure (bar) SMD (or D 32 ) Sauter Mean Diameter (µm) T Temperature (ºC) Va Airflow velocity (m.s -1 ) DP differential pressure applied Subscript W Water a Air µ, δ, π, ω power constants REFERENCES 1. Chaker, M., Meher-Homji, C. B. and Mee T. R. III, Inlet Fogging of Gas Turbine Engines-Part A: Fog Droplet Thermodynamics, Heat Transfer and Practical Considerations; ASME Paper Nos: 02-GT- 62, 63 and 64 (02). 2. Chaker, M., Meher-Homji, C. B. and Mee T. R. III, Inlet Fogging of Gas Turbine Engines- Part B: Fog Droplet Sizing Analysis, Nozzle Types, Measure- 6 Copyright 0 by ASME

ment and Testing,; ASME Paper Nos: 02-GT- 62, 63 and 64 (02). 3. Chaker, M., Meher-Homji, C. B. and Mee T. R. III, Inlet Fogging of Gas Turbine Engines- Part C: Fog Behavior in Inlet Ducts, CFD Analysis and Wind Tunnel Experiments, ASME Paper Nos: 02-GT-62, 63 and 64 (02). 4. Chaker, M. A., Meher-Homji, C. B. and Mee, T. III, Inlet Fogging of Gas Turbine Engines Experimental and Analytical Investigations on Impaction Pin Fog Nozzle Behavior, ASME Paper No. GT03-38801 (03). Meher-Homji, C.B., Mee, T.R., Gas Turbine Power Augmentation by Fogging of Inlet Air, Proceedings of the 28 th Turbomachinery Symp osium, Houston, TX, September 1999. 6. Meher-Homji, C.B., and Mee, T.R. III Inlet Fogging of Gas Turbine Engines- Part B: Practical Considerations, Control and O&M Aspects, ASME Turbo Expo 00, Munich May 00. ASME Paper No: 00-GT-08. 7. Bhargava R., Bianchi M., Melino F., Peretto, A. Meher-Homji C. B. and Chaker M. A., Inlet Fogging for Gas Turbine Power Augmentation, a State of the Art Review, Proceedings of the International Conference on Power Engineering-03(ICOPE-03) November 9-13, 03, Kobe, Japan 8. Hill, P. G., Aerodynamic and Thermodynamic Effects of Coolant Ingestion on Axial Flow Compressor, Aeronautical Quarterly, pp. 333-348 (1963). 9. Utamura, M., Kuwahara, T., Murata, H. Horii, N., Effects of Intensive Evaporative Cooling on Performance Characteristics of Land-Based Gas Turbine, Proceedings of the ASME International Joint Power Generation Conference, 1999.. Lefebvre, A. H., Atomization and Spray, Chap. 6, (1989), Taylor & Francis Press 11. Chaker, M., Effect of Airflow Velocity on Droplet Size for Gas Turbine Fogging Nozzles, ILASS Americas, 13 th Annual Conference on Liquid Atomization and Spray Systems, Madison, WI, May 01 12. Savic, S., Mitsis, G., Hartel, C., Khaidarov, P. and Pfeiffer, P., Spray Interaction and Droplet Coalescence in Turbulent Air-Flow An Experimental Study with Application to Gas Turbine High Fogging, ILASS Europe, Zaragoza, Spain, September 9 (02) 13. T.L. Harvill, D.J. Holve, Size distribution measurements under conditions of multiple scattering with application to sprays, Ilass 1998 USA, Sacramento, CA 14. Ward-Smith R.S., Wedd M.W., Jones, R.M. and Higgs D.M.J A novel measurement technique for determining continuous particle size distributions of concentrated sprays, Ilass Europe 6-8 July 1998, Manchester, England 7 Copyright 0 by ASME