MODEL FA5 Air Filtration System. Operations Manual

Similar documents
FA1 Series Air Filtration System. Operations Manual

MODEL GS1-100 Air Filtration System. Operations Manual

MODEL FA1 Mini Air Filtration System. Operations Manual

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

X-3400A, X-3500, X-3700 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

SPH General Manual 400 Series

Videojet Fume Extractor Preventive Maintenance Guide

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

OmniAire Portable Air Cleaner OA1200PAC

MODEL MC1500 Installation and Operation Manual Important:

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

EXT DUCTLESS FUME HOOD

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Owner s Manual Phoenix GuardianR

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BTX-208. Fume Extraction System _B

Model G14SD Vapor Management System

HEPA AIR FILTRATION SYSTEM

Quest H5. Quest Dry. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest H5:

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

Miracle State Of The Art Air Filtration System!

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Table of Contents. Safety Information Main Functions Set-Up Operation Maintenance Troubleshooting Specifications Customer Support Warranty Information

MC2500. Installation and Operation Manual

POWER PINNER CD HAND WELDER 7300 OPERATOR S MANUAL

Portable HEPA System

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BVX-100. Fume Extraction System _B

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

AUTO CHARGE D PUMP PLUS

I-6500 Series. Industrial Applications. Operations & Maintenance Manual. Air Purifiers for. Manufactured. Serial number.

EXT HEPA/CARBON FUME HOOD

Installation & Service Manual for Portable Fume Collector. Model PFC-800

LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL

OWNER S MANUAL C O M M E R C I A L I N D O O R A I R Q U A L I T Y S O L U T I O N S. Total High Efficiency Particulate & Gaseous Filtration System

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

Omniaire 1000V Instruction Manual-8/05

Portable Air Purifiers

XS500 Load Bank. Read all instructions before using the load bank. Contents

6300 Series Owner/Operator Manual

User s Manual and Operating Instructions

BATTERY SAVER LOW RIPPLE HO

The BVX-100 Fume Extraction System

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

SPEED KEY After the fan has started, press to change fan speed in sequence of: Low - Medium - High. The corresponding indicator will illuminate.

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

Loctite Air Filtration System Part Number EQUIPMENT. Operation Manual

PLANNING THE INSTALLATION

User Manual. Model: FSL300 Dual Port Laser Fume Extractor

MODEL SCA Installation and Operation Manual Important:

Model Numbers: MAC-36-BDF, MAC-42-BDF, MAC-48-BDF CONSUMER: READ AND SAVE THESE INSTRUCTIONS

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL


OWNER S MANUAL MODEL FSHEPA375 WHOLE-HOUSE TRUE HEPA AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

OPERATIONAL INSTRUCTIONS

OPERATOR S MANUAL ACE - P100

OPERATIONAL INSTRUCTIONS

CALTRAP INSTALLATION AND OPERATIONS MANUAL

Airistar 100GT Owner s Manual Airistar 100GT Air Purifier

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

GSL Electronics Modified Sine Wave Power Inverters

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Multistage Air Filtration Systems Instruction Manual

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Cleanshield HEPA 550 Owner s Manual

Model 6275RC 50% Duty Cycle Compressor

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

Fume Extraction Planning Guide

Powerful. Efficient. RED. Look to Micro Air Dust Collectors for clean air and cost-effective operation.

Quick-Start Operating Guide Document No Universal Hood Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010

36 VOLT AUTOMATIC BATTERY CHARGER PART NO

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

ST Charger. Industrial Battery Charger

QPET, QPETXU Battery Chargers

Ductless Nanoparticle Containment Enclosures

INSTALLATION GUIDE. Greentek. Residential use only MODEL HS 3.0

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

OPERATOR S MANUAL. TW-i SERIES. Capacitor Discharge Stud Welder. MODELS: TW-i 250 TW-i 250CP TW-i 321 TW-i 375

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

POWER PINNER HAND WELDER 7200 OPERATOR S MANUAL

Operating Instructions. International English. CCS Dust Extractor

MODEL ELC-12/40-CVM-D BATTERY CHARGER

MODEL SAFETY & INSTRUCTION MANUAL

Comply with the above specifications? Yes No

MODEL MA4210 Installation and Operation Manual Important:

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

BROMAN MODEL 123XL PORTABLE LOAD BOX. Series 2

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

Operations and Service Manual. XE400D-SB Load Bank

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Aura. Filtration Fume Cupboards All Models: AU-250, AU-550, AU-750, AU E, ES & EH. Operators Manual. Issue 06 August 2010

Transcription:

MODEL FA5 Air Filtration System Operations Manual READ AND SAVE THESE INSTRUCTIONS WARNING: Disconnect from power supply before performing maintenance procedures such as cabinet cleaning, changing filters or servicing of electric motor or other electric components WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device. WARNING: For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors. CAUTION: Do not operate without having all filters in place. Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Arrange cord away from traffic area and where it will not be tripped over.

GETTING STARTED I n i t i a l s e t - u p 1. Remove the FA5 unit from the packaging and locate and open the accessory box. 2. Open the FA5 cabinet and remove the protective packaging from the gas/odor filter(s) (part# FA501D). Replace the filter into the cabinet noting the airflow direction arrow should point up. 3. The HEPA filter (Part# FA500) and Pre-filter (Part# FA540B) are preinstalled - simply verify the filters are in position. 4. Close and latch the front door. 5. The FA5 is now ready for use. L o c a t i n g t h e a i r c l e a n e r : Placing the FA5 as close as possible to the pollution source reduces the amount of hose or duct needed, reduces back-pressure, lowers power consumption and improves overall performance. Wheels are standard equipment on the FA5, but rubber isolators are available if the unit is to be placed permanently in position. If you prefer isolators, call 800-432-7550 to arrange a no-charge exchange. I n l e t h o s e a t t a c h m e n t : Install the air inlet flange (labeled) to the air inlet port located at the back bottom of the FA5 cabinet. Secure the port with the screws provided. Attach the hose to the inlet. Connect the hose to a Fumex suction hood or place as close as possible to the pollution source. E l e c t r i c p o w e r Locate the Fumex nameplate located on back of cabinet to determine the power supply necessary. The FA5 is factory configured for 120/1/50-60 or 230/1/50-60. Please contact Fumex Inc. with any questions/concerns in regards to power supply. 2

CONTROLS On/Off Switch Simple on/off power button located on front display - green light indicates power to the unit. Blower/Fan The FA5 utilizes a variable speed blower with 10 speed settings. Press the up /down arrows to increase and decrease the blower speed. Blower gradually increases in speed as arrow is pressed - some slight delay is normal operation. Speed is indicated by the bar graph located above blower label. A green light will indicate that the blower is operating no light indicates a blower failure. Filter monitoring The FA5 utilizes independent pressure modules to monitor the status of each particulate filter (the pre-filter and the HEPA filter). Filter status is indicated by the corresponding bar graph ( pre for part# FA540B; HEPA for part# FA500). The bar graph will increase in 25% increments until the filter is loaded. Amber lights will indicate that a filter change is necessary. The FA5 contains a VOC indicator to detect odors/gases in the exhaust stream. The system continually monitors the exhaust stream and indicates on the bar graph labeled cell. When breakthrough is detected the amber light will illuminate indicating a filter change is necessary. GENERAL FILTER CARE Fumex FA5 air purifiers feature a multi-stage filtration system designed to remove a wide range of pollutants from the process plume in an extremely efficient, cost-effective manner. S T A N D A R D F I L T E R S : Part # FA540B Pre-filter Assembly The pre-filter assembly is the first stage in the filtration process. Unique design minimizes operator/maintenance personnel exposure to contaminants. Replacement: Filter life is highly dependent on the amount and size of the captured particulates. Average service life is 4-6 months. Part # FA500 HEPA Filter The HEPA filter is 99.97% efficient in removing particles as small as 0.3 from an airstream. Particles of this size are respirable and can cause significant respiratory problems. Replacement: A HEPA s service life is determined by the volume of sub-micron particles remaining in the airstream after passing through the pre-filters. When properly protected, and depending on loading, HEPA filters often provide months of service. Average service life is 6-8 months. Part # FA501D Gas/Odor Filter (CELL) Most process plumes contain several gases, some odorous some not, some toxic at elevated concentrations some completely harmless regardless of concentration. To ensure employee safety the type and concentration of pollutants must be determined. Please contact Fumex Engineering for selection assistance. 3

The FA5 utilizes a blended activated carbon and activated alumina impregnated with KMnO4 filter to capture and treat gases/odors. This combination of materials provides protection across a broad range of gases commonly found in industrial manufacturing processes. Replacement: The gas/odor filter ( cell ) life is dependent on the concentrations and characteristics of the gases generated in the process. The FA5 monitors the effectiveness of the filter with an integrated electronic VOC sensor that will indicate with an amber light when breakthrough is detected. Some gases have very low odor thresholds and will become a nuisance prior to filter saturation indicator and can be changed accordingly. GENERAL MAINTENANCE 1) The blower motor(s) is a sealed unit, 24,000 hr. MTBF rated. It is permanently lubricated and does not require oiling keep it free of dust accumulations to prevent overheating. 2) Remove any loose accumulations of dust/debris from the air filter chamber periodically. This product employs overload protection (fuse). A blown fuse indicates an overload or short-circuit situation. If the fuse blows, unplug the product from the outlet. Replace the fuse as per the user servicing instructions (follow product marking for proper fuse rating) and check the product. If the replacement fuse blows, a short circuit may be present and the product should be discarded or returned to an authorized service facility for examination and/or repair Remote Interface/Connectivity The FA5 can be supplied with an optional relay package providing remote start/stop and filter monitoring capabilities. Please refer to attachment A for instructions. 4

R e p l a c e m e n t P a r t s P a r t # I t e m P a r t # I t e m C a b i n e t r y E l e c t r i c a l FA508 Wheels, standard FA5110F Blower motor ass y, 115/1/50-60 FA509 Vibration Isolators FA5110G Blower motor ass y, 240/1/50-60 FA517 Cabinet latch FA501 Display board assembly FA518 Cabinet hinge FA502 Power board assembly FA514 Fuse, 10 amp (120vac) FA514A Fuse, 15 amp (240vac) FA506-3 Flanged air inlet nipple, 3 FA515 Cordset (120vac) FA506-4 Flanged air inlet nipple, 4 FA515B Cordset (230vac) FA506-6 Flanged air inlet nipple, 6 FA513 Fuseholder F i l t e r s G a s / O d o r F i l t e r s FA500 HEPA filter FA501D A/C + A/A cell w/ KMnO4 FA540B Pre-Filter W a r r a n t y a n d L i a b i l i t y l i m i t a t i o n s : Fumex FA5 air cleaners are guaranteed for 24 months from date of invoice to be electrically and mechanically sound. This warranty covers the material and workmanship only. Any defective item will be repaired or replaced, at our option, free of charge provided it has not been misused, abused, or otherwise damaged and is returned PREPAID to: Fumex, Inc. 1150 Cobb International Pl., Kennesaw, GA 30152 There are no warranties which extend beyond the descriptions set forth in this warranty, notwithstanding any knowledge of Fumex, Inc. regarding the use or uses intended to be made of goods, proposed changes or additions to goods, or any assistance or suggestions that may have been made by Fumex personnel. Customer is responsible for determining the suitability of Fumex products for customer s use or resale, or for incorporating them into objects or applications which customer designs, assembles, constructs or manufactures. Fumex reserves the right to discontinue any item and to make changes in the specifications, terms and conditions or prices at any time without prior notice. Information furnished in the specifications is believed to be accurate and reliable at time of printing, however Fumex accepts no responsibility for product use, or the effect of future design or specification changes. For Assistance or Technical Support please Contact Fumex Inc. phone 770-514-7907 fax 770-514-1547 USA toll-free 800-432-7550 www.fumexinc.com Fumex, Inc. 1150 Cobb International Place Kennesaw, GA USA 30152 Fumex, Inc., 2010, all rights reserved. Specifications subject to change without notice 5

FA5 Relay Package 120/240/1/60 1 BLACK 24 VOLT START OUT (NEG) 2 RED 24 VOLT START IN (POS) 3 BROWN Gas/Odor WARNING SIGNAL 4 ORANGE POWER FOR WARNING LIGHTS 5 YELLOW HEPA WARNING SIGNAL 6 ORANGE POWER FOR WARNING LIGHTS 7 ORANGE POWER FOR WARNING LIGHTS 8 GREEN PRE FILTER WARNING SIGNAL 9 WHITE DRY CONTACT ( BLOWER) 10 BLUE DRY CONTACT (BLOWER) RELAY CONNECTOR WHITE WIRE ACTUAL CONNECTION AT INTERFACE BOARD 6

FA5 DIGITAL UNIT 120/240/1/60 CONTROL PANEL VOC SENSOR BOARD INTERFACE CABLE MOTOR HARNES MOTOR RELAY CONNECTOR FUSE INTERFACE BOARD VOLTAGE SELECTOR POWER CORD WHITE FILTER 7

FA5 DIGITAL UNIT 240/1/60 CONTROL PANEL VOC SENSOR BOARD INTERFACE CABLE RELAY CONNECTOR FUSE INTERFACE BOARD VOLTAGE SELECTOR POWER CORD WHITE MOTOR MOTOR 8

RELAY ACTIVATION PROCEDURES FOR FA5 UNIT 1. Remove all power sources from FA5 unit 2. Locate six screws securing unit control panel 3. Remove all and gently pry Control panel loose six screws CAUTION Do not allow panel to hang from hoses or interface cable Relay activation jumper Relay activation jumper 4. Locate relay activation Jumper on control panel. (Small plastic rectangle) There are two possible locations depending on which board revision you have 5. Gently remove jumper by pulling cap off pins. Shorting cap should be installed over a single pin for storage and to prevent loss of cap. Once the jumper has been removed the unit will only start by applying the proper voltage to the start stop relay. When the unit is running the on and off switch can be used as long relay has power. 6. Reinstall control panel and screws 7. Apply power to start relay (see wiring diagram for your unit) 9