RCBA- MULTIFLEX INDOOR COILS

Similar documents
INDOOR COILS RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR COILS. AIRFLOW CAPACITIES CFM [ L/s]

INDOOR COILS RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR COILS. AIRFLOW CAPACITIES CFM [ L/s]

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring New Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces

CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Cased/Uncased Coils For Gas And Oil Furnaces

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

Cased/Uncased Coils For Gas And Oil Furnaces

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

AIR HANDLERS AIR HANDLERS. UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant.

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

CONDENSING UNITS ACHIEVER 12 SUPER HIGH EFFICIENCY CONDENSING UNITS UAMA- SERIES. Seven Models

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

CONDENSING UNITS RAKB- SERIES. Seven Models

HEAT PUMPS CLASSIC X HEAT PUMPS RPKA- SERIES. Nominal Sizes 1 1 /2 to 5 Tons [5.28 to kw]

CONDENSING UNITS CLASSIC X CONDENSING UNITS RAKA- SERIES. Seven Models. Cooling Capacities 17,000 to 56,500 BTU/HR [4.98 kw] to [16.

FORM NO. HSC-543 AIR HANDLERS

Rheem High Efficiency Air Handler

HEAT PUMPS UPLB- SERIES. Seven Models

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

HEAT PUMPS UPKB- SERIES. Seven Models

Rheem High Efficiency Air Handler

Ruud High Efficiency Air Handler

CONDENSING UNITS UAPC- SERIES. Six Models. Cooling Capacities 23,200 to 56,500 BTU/HR [6.8 kw] to [16.6 kw]

AIR CONDITIONERS WA14**A SERIES

14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

INDOOR COOLING COILS FOR DUAL FURNACE APPLICATION

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

HMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

TECHNICAL SPECIFICATIONS

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

B6BMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

ELECTRIC HEAT AIR HANDLERS

CAPF, CAUF, CHPF, & CSCF DUAL-REFRIGERANT SERIES

Page Number. Contents: Product Features 2. Physical Data 2. Nomenclature. 3. Blower Performance 3. Electrical Data 4. Warranty.. 6

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

AIR CONDITIONERS WA16 SERIES

ARUF PRODUCT SPECIFICATIONS AIR HANDLER 1½ TO 5 TONS MULTI-POSITION, THREE-SPEED WITH GALVANIZED CABINET

AWUF Series. Wall-Mount Air Handler 1½- to 3-Tons

Modular Variable Speed Air Handlers

TECHNICAL SPECIFICATIONS

HE Series Evaporator Coils

HE Series Evaporator Coils

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

B6EMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Dual-Refrigerant Coils

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

B6VMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler with TXV 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

MB6(B,E,V)M Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Modular Indoor Blower 13+ SEER Residential System. Additional MB6EM Features:

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

HE, HH, LA/LH Series Evaporator Coils

HE, HH, LA/LH Series Evaporator Coils

ELITE SERIES R-410A Ready - Multi-Position

Multi-Position Air Handler. 1½ to 5 Tons. with Energy-Saving Motor

[-]CHL. Parts List Multiflex Cased or Uncased. (R-410A) Indoor Coils Series L Sizes CATALOG TAB - Indoor Coils

13 SEER CONDENSING UNITS

[-][-]AH DESIGN C. Parts List Electric Furnace/ Air Handler Sizes 14-24

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

14.5 SEER VALUE SERIES CONDENSING UNITS

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

BCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY

INSTALLATION INSTRUCTIONS

Table of Contents GF801U Series

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

MERIT Series R-410A - Upflow / Horizontal - Variable Speed


Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY

SELF-CONTAINED HEAT PUMP PACKAGE UNITS

BCE3 PRODUCT SPECIFICATIONS STANDARD AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

ELITE Series R-410A - Upflow / Horizontal

Rheem Classic Series Upflow/Horizontal Gas Furnace

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Transcription:

FORM NO. C11-207 REV. 3 Supersedes Form No. C11-207 Rev. 2 RCBA- MULTIFLEX INDOOR S AIRFLOW CAPACITIES 600-2000 CFM [218-944 L/s] Rheem Value Series Indoor Coils are designed for use with Rheem Value Series outdoor units in upflow, downflow and horizontal configurations. The MultiFlex coils provide nominal capacities ranging from 18,000 to 60,000 BTUH [5.27 to 17.58 kw]. The patented single-row, single-coil pleated concept results in extremely low pressure drops and corresponding easy cleaning. Drain connections may be made from either side of the coil. Engineering Features Constructed of enhanced aluminum fins bonded to inner grooved copper tubing. Coils have sweat fitting refrigerant connections. Primary condensate drain connections are 3 /4" [19 mm] F.N.P.T. Coils are A.R.I. certified for system application with a wide variety of Rheem Value Series outdoor units. Condensate drain pan is constructed of a high grade, heat resistant, corrosion free polymer material.

MODEL NUMBER IDENTIFICATION R C B A 37 65 G H Rheem Value Series Coil Type of Coil B = Flowcheck Standard Cooling/ Heat Pump Design Series A = 1st Design Nominal Capacity 24 = 18,000 to 24,000 BTUH [5.27 to 7.03 kw] 37 = 30,000 to 36,000 BTUH [8.79 to 10.55 kw] 48 = 42,000 to 48,000 BTUH [12.31 to 14.06 kw] 60 = 60,000 BTUH [17.58 kw] Metering Device ** = Flowcheck Piston (RCBA Coils) Airflow/Refrigerant Connections Horizontal Drain Pan REFRIGERANT METERING RCBA Coils PISTON SIZES (PART NUMBER 61-23414-**) MODEL/SIZE TON [kw] 10PJA- HEAT PUMP PRELIMINARY 10 SEER RECIP. MODELS 10AJA- CONDENSING UNITS 10 SEER RECIP. MODELS 18/1.5 [5.28] 53 51 24/2.0 [7.03] 61 61 30/2.5 [8.79] 70 65 36/3.0 [10.55] 68 73 42/3.5 [12.31] 78 78 48/4.0 [14.07] N/A 78 60/5.0 [17.58] N/A 89 2 ICECO

RXCT- EXPANSION VALVE CONVERSION KIT FOR RCBA INDOOR S Use an expansion valve kit to convert RCBA- indoor coils to High Efficiency Coils EXPANSION VALVE KIT WITH RCBA- APPLICATION MODELS RCBA- APPLICATIONS 12 SEER COOLING ONLY MODELS RXCT-BCA RCBA-24 1 1 /2 Ton [5.28 kw].099 RXCT-BCB RCBA-24 2 Ton [7.03 kw].120 RXCT-BCC RCBA-37 2 1 /2 Ton [8.79 kw].140 RXCT-BCD RCBA-36/37 3 Ton [10.55 kw].157 RXCT-BCE RCBA-48 3 1 /2 Ton [12.31 kw] & 4 Ton [14.07 kw].157 PISTON SIZE ICECO 3

UNIT DIMENSIONS & WEIGHTS RCBA- UNCASED S MODEL NUMBER UNCASED X LIQUID I.D. CONNECTION SIZE (IN.) [mm] SWEAT SUCTION I.D. UNIT WEIGHT (LBS.) [Kg] UNCASED WT. SHIP WT. RCBA-24 12 1 /4 [311] 15 [6.80] 17 [7.11] 3/4 [19] RCBA-37 15 3 /4 [400] 20 [9.07] 22 [9.98] 3/8 [10] RCBA-48 19 1 /4 [489] 26 [11.79] 29 [13.15] 7/8 [22] RCBA-60 22 3 /4 [578] 32 [14.51] 35 [15.88] 4 ICECO

TXBC CABINET WIDTH SUPPLY & RETURN AIR DIMENSIONS WITH TXBC CASING UPFLOW/HORIZONTAL SUPPLY AIR RETURN AIR TXBC CABINET WIDTH 14" [356] W 13" 7 /3 [330] D W 13" 7 /3 [330] D 17.5" [445] 16 1 /2" [419] 16 1 /2" [419] 21" [533] 20" 7 /3 [508] 20" 7 /3 [508] 24.5" [622] 23 1 /2" [597] 23 1 /2" [597] DOWNFLOW TXBC CABINET WIDTH 14" [356] SUPPLY AIR RETURN AIR W W 13" 7 /3 [330] 13" 7 /3 [330] D D 17.5" [445] 16 1 /2" [419] 16 1 /2" [419] 21" [533] 20" 7 /3 [508] 20" 7 /3 [508] 24.5" [622] 23 1 /2" [597] 23 1 /2" [597] G(-) FRONT CONNECTION FOR RCBA- I235 NOTE: Models 14 and 17 have front connections only unless option 31 is available which allows side connections. Side connection can also be fieldinstalled to models 21 and 24. PHYSICAL DATA MODEL NUMBER APPROX. DESIGN AIRFLOW RANGE (CFM) [L/s] FACE AREA (SQ. FT.) [m 2 ] FINS/IN. NUMBER OF SLABS RCBA-24** 600-800 [283.1-377.6] 5.07 [.471] 4 RCBA-37** 1000-1200 [471.1-566.3] 7.60 [.706] 6 18 RCBA-48** 1400-1600 [660.7-755.1] 10.13 [.941] 8 RCBA-60** 1400-2000 [943.9] 12.67 [1.18] 10 NOTES: ** Indicates piston size on RCBA coils. ICECO 5

UNCASED APPLICATION REPLACEMENT OR AIR HANDLER UNITS WITHOUT S MODEL NUMBER RC(B)A-24 RC(B)A-37 RC(B)A-48 RC(B)A-60 NO. SLABS 4 6 8 10 14AH NOTES: Requires coil code 00 (without coil with plenum) in unit model number. All require horizontal drain pan accessory (RXBD-DA) for horizontal applications. Cabinet widths 14 = 14" [355.6], 17 = 17.5" [444.5], 21 = 21" [533.4], 24 & 25 = 24.5" [622.3]. X AIR HANDLER 17AH 21AH 24AH X X X RCBA WITH TXBC CASED APPLICATION Coil can be matched to heating products as listed in table below. NO. OF SLABS PLENUM WIDTH 4 14 A 4 17.5 GAS FURNACE 80% UPFLOW, DOWNFLOW & HORIZONTAL MODELS A & B 6 17.5 E A A A 6 21 A&B A & B A & B 8 21 E A A A 8 24.5 A & B A & B A & B 10 24.5 E A A A FURNACE WIDTH 14 [355.6] 17.5 [444.5] 21 [533.4] 24.5 [622.3] A & B NOTES: BOLD AREAS INDICATE FLUSH FIT APPLICATIONS A Upflow/Downflow/Horizontal Application. Horizontal application requires field installed horizontal drain pan accessory RXBD-DA (One pan fits all). B Upflow/Downflow/Horizontal Application. Requires use of RXBA-AA internal coupler accessory. E Upflow and Horizontal application requires external plenum adapter accessory RXBA-AC. Downflow/Horizontal application requires external plenum adapter accessory RXBA-AD. GAS FURNACE 34" 90 PLUS UPFLOW, DOWNFLOW & HORIZONTAL CONDENSING MODELS 05 07 10 12 15 04 06 07 10 12 17.5 [444.5] A & B 21 [533.4] 24.5 [622.3] 6 ICECO

RCBA- PRESSURE DROP No. of Coil Slabs 4 6 8 10 Coil Cooling Size 18, 24 30, 36 42, 48 60 Coil Position (Airflow) Up Down Up Down Up Down Up Down AIRFLOW CFM [L/s].05 [.01] 578 [272.8] 521 [245.9] 752 [354.9] 673 [317.6] 895 [422.4] 764 [360.6] 1005 [474.3] 885 [417.7] Static Pressure.10 [.02] 889 [419.6] 827 [390.3] 1113 [525.3] 977 [461.1] 1299 [613.1] 1103 [520.6] 1559 [437.8] 1308 [617.3] Drop Through Wet.15 [.04] 1158 [546.5] 977 [461.1] 1416 [668.3] 1244 [587.1] 1641 [774.5] 1386 [654.1] 1939 [915.1] 1605 [757.5] Cooling Coil In. W.C. [kpa].20 [.05] 1346 [635.2] 1149 [542.3] 1647 [777.3] 1413 [666.9] 1960 [925.0] 1637 [772.6] 2271 [1071.8] 1883 [888.7].25 [.06] 1546 [729.6] 1271 [599.8] 1876 [885.4] 1633 [770.7] 2187 [1032.1] 1826 [861.8] 2552 [1204.4] 2134 [1007.1].30 [.07] 1665 [785.8] 1401 [661.2] 2065 [974.6] 1784 [841.0] 2429 [1146.4] 2013 [950.0] 2890 [1363.9] 2365 [1116.2] NOTES: Air pressure drop for horizontal airflow is the same as that shown for upflow. ACCESSORIES HORIZONTAL DRAIN PAN KIT RXBD-DA This horizontal drain pan accessory is for installation in cased indoor cooling coils. This accessory allows a coil to be converted for horizontal application. The same drain pan fits all RCBAcoils. (Kit has external metal drain pan extension required for gas furnace applications only). R X B D D A RHEEM CLASSIFICATION X = ACCESSORIES APPLICATION B = BLOWER UNIT ONE SIZE (Fits All) DESIGN SERIES KIT TYPE D = HORIZONTAL DRAIN PAN GENERAL TERMS OF LIMITED WARRANTY ICECO SM will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. MultiFlex Coil leaks caused by factory defects...five (5) Years Any Part...Five (5) Years For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or visit www.icecohvac.com. ICECO 7

ACCESSORIES (continued) Figure 1. Indoor coil and drain pan set-up for horizontal left-hand air supply. Designated as (L) in model number. Side connection coil shown. RCBA- HORIZONTAL INDOOR ASSEMBLY Figure 2. Indoor coil and drain pan set-up for horizontal right-hand air supply. Designated as (R) in model number. Side connection coil shown. *Foam Tape Foam tape is factory installed on the sides of the vertical drain pan if the coil is provided in a coil casing. Foam tape is shipped loose with uncased coils. If uncased coil is installed vertical in a coil casing or air handler, install the foam tape on the sides of the vertical drain pan. If installed horizontal, DO NOT install foam tape on the side of the vertical drain pan that fits into the horizontal drain pan. Remove foam tape, if already attached, from the side of the vertical drain pan that fits into the horizontal drain pan. If coil, vertical or horizontal, is installed in coil casing or air handler with optional Florida Insulation, DO NOT install foam tape on either side of the vertical drain pan. I151 8 ICECO

ACCESSORIES (continued) INTERNAL COUPLER ACCESSORY RXBA-AA This internal coupler accessory is for installation in cased indoor cooling and heat pump coils. This allows a nominal size coil to be installed in the next larger size casing. PLENUM ADAPTER ACCESSORY RXBA-AC AND RXBA-AD This internal coupler accessory is for installation in cased indoor cooling and heat pump coils. This allows a nominal size coil to be installed in the next larger size casing. R X B A - A A COUPLING COMBINATIONS TO CASING CASING TO FURNACE CODE A C D NOMINAL BTUH [kw] 24,000 [7.03] 36,000 [10.55] 48,000 [14.07] 36,000 [10.55] 48,000 [14.07] 60,000 [17.58] 36,000 [10.55] 48,000 [14.07] 60,000 [17.58] CASING WIDTH 17.5 [444.5] 21.0 [533.4] 24.5 [622.3] 17.5 [444.5] 21.0 [533.4] 24.5 [622.3] 17.5 [444.5] 21.0 [533.4] 24.5 [622.3] FURNACE WIDTH 17.5 [444.5] 21.0 [533.4] 24.5 [622.3] 14.0 [355.6] 17.5 [444.5] 21.0 [533.4] 14.0 [355.6] 17.5 [444.5] 21.0 [533.4] INTERNAL EXTERNAL Internal External Upflow Only External Downflow/ Horizontal RCGJ-/RCHJ- HIGH EFFICIENCY S DESIGN SERIES A = 1ST DESIGN KIT TYPE A = COUPLER/COMBINATION (ADAPTERS) APPLICATIONS B = BLOWER UNITS CLASSIFICATION X = ACCESSORIES RHEEM VALUE SERIES ICECO 9

RXBC- INDOOR CASING UNIT DIMENSIONS & WEIGHTS RXBC- INDOOR CASINGS MODEL NUMBER WIDTH W TXBC-14 14 1 /2 [356] TXBC-17 17 1 /2 [445] TXBC-21 21 1 /2 [533] TXBC-24 24 1 /2 [622] HEIGHT 17 1 /2 [445] DEPTH 22 [559] UNIT WEIGHT WT. [Kg] SHIP WT. [Kg] 17 [7.11] 19 [8.62] 19 [8.62] 21 [5.33] 20 [9.07] 23 [10.43] 22 [9.98] 25 [11.34] SUPPLY ➀ WIDTH 13 1 /2 [330] 16 1 /2 [419] 20 1 /2 [508] 23 1 /2 [597] NOTES: ➀ Supply dimensions for upflow & horizontal units. This is return dimensions for downflow units. ➁ Return dimensions for upflow & horizontal units. This is supply dimensions for downflow units. DEPTH 19 5 /8 [498] RETURN ➁ WIDTH 13 1 /2 [330] 16 1 /2 [419] 20 1 /2 [508] 23 1 /2 [597] DEPTH 19 7 /8 [505] T X B C -C 14 I INSULATION I = Insulated Blank = Uninsulated CABINET WIDTH 14 = 14" [355.6 mm] 17 = 17.5" [444.5 mm] 21 = 21" [533.4 mm] 24 = 24.5" [622.3 mm] DESIGN SERIES C = Front Connection CASING BLOWER UNIT ACCESSORY RHEEM VALUE SERIES AIR BYPASS FRAME FOR UNCASED S (STANDARD ON ALL UNCASED S) To prevent air bypass around the drain pan, coil support frames are provided with each uncased coil. Frame is only used when coil is not installed in other than standard coil casing. Air bypass frame is not for use with TXBC coil casing or AH series air handlers. I423 10 ICECO

NOTES ICECO 11

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road, Fort Smith, Arkansas 72908 In keeping with its policy of continuous progress and product improvement, ICECO reserves the right to make changes without notice. PRINTED IN U.S.A. 3-07 DC FORM NO. C11-207 REV. 3 Supersedes Form No. C11-207 Rev. 2