HE, HH, LA/LH Series Evaporator Coils
|
|
- Irma Shepherd
- 6 years ago
- Views:
Transcription
1 SGHAC33 February 2015 HE, HH, LA/LH Series Evaporator Coils Specification Guide Contents... Pa Page HE Series ACoils Features... 2 Nomenclature... 3 Specifications... 4 Pallet Quantities HH Series Horizontal Slab Coils Features & Nomenclature Specifications LA/LH Series Large Tonnage A and H Coils Features & Nomenclature... Specifications Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications are subject to change without notice and without obligation on our part. Please contact your ADP representative or distributor to verify details. by Advanced Distributor Products. All rights reserved West Park Place Blvd., Stone Mountain, GA 087
2 HE Series Product Features High efficiency lanced fin design. Nohassle 5 year warranty. R22, R410A, AC & Heat Pump compatible. All coils have durable packaging with bar coded labels on the box. Threaded expansion valves available factory installed or as a field installed kit. Coils are air pressure tested at 0 psi, leak tested with helium, sealed with rubber plugs, then charged with dry air. Piston options include externally accessible body for easy piston change out and/or TXV installation. Liquid line refrigerant connections are 3/8" ODF. Suction line refrigerant connections are 3/4" ODF (ACoil size models) or 7/8" ODF (ACoil size models & all Horizontal SlabCoils). Suction line refrigerant connections are 1.125" on slab numbers E43, E, E56, and E65 for size models and higher. Copper refrigerant connections for easy brazing on both copper and aluminum slab models. Cased coils have heavy gauge embossed galvanized cabinets fully lined with 5/8" foil faced insulation. Optional painted cabinets. Corrosion resistant coil header plates. All ACoils are upflow or downflow capable. All multiposition coils are upflow, downflow, and left or right airflow capable. Cabinet insulation hold down tabs for easy drain pan removal. Interlocking doors reduce air leakage and allow for easy access. Enhanced refrigerant pipe grommets: secure, tight, and easy to install. Intertek lab tested 1% or less cabinet air leakage for better efficiency. Foam drain seal for reduced air leakage. Noncaptive refrigerant lines with long stubs make for easy installation. All multiposition coils are field convertible from horizontal righttoleft airflow and horizontal lefttoright airflow. Dual 3/4" FPT condensate drains on frontleft and frontright side of drain pans. UV resistant drain pans are molded of high temperature (4 deg. F) engineered polymer. Microban antimicrobial additive to inhibit the growth of mold and mildew in the drain pan. HydroTEC low water retention drain pan. Expansion valve with improved temperature sensing: 1. Mounted inside cabinet to prevent external sweating 2. Bulb clamped standard factory installed 3. Wrapped bulb optional factory installed WARNING Face velocity above 3 ft/min. is not recommended for downflow or counterflow applications due to potential water blowoff. 2
3 HE Series Nomenclature H G 2 C 145 B AP Cabinet Color Piston Size [1] H = Embossed AP = TXV access port [2] A = Armstrong MBTUH R22 R410A D = Ducane/AireFlo G = ICP J = Goodman/Amana L = Lennox N = Nordyne P = Carrier/Bryant/Payne R = Rheem/Ruud T = Trane/American Std. 12 = = = = = = = = Y = York/Luxaire/Coleman [1] Piston will always be sized to match the nominal BTU rating of the coil. Slab Number [2] TXV access port standard on E & A = Copper slab factory installed TXVs; G & B = Aluminum slab optional on piston models. Metering Device 1 = Piston (R410A) Product Code [3] 2 = Piston (R22) 00 = Righthand uncased 3 = Bleed A/C TXV (R22) 01 = Righthand cased 4 = Nonbleed A/C TXV (R22) 04 = Lefthand uncased 5 = Nonbleed HPA/C TXV (R22) 05 = Lefthand cased 6 = Nonbleed A/C TXV (R410A) 20 = Righthand cased multiposition 9 = Nonbleed HPA/C TXV (R410A) 22 = Lefthand cased multiposition [3] Refrigerant connections and exposed Nominal MBTUH drain connections are both on the left or right side as indicated. Cabinet Depth A = Uncased D = 21.0" C = 20.5" E = 21.5" Cabinet Height 00 = Uncased Note: Cabinet height not a selectable Width 12 = 12.5" option, see cased dimensions. Cased Uncased 16 = 16.5" 1 = 14" 1 = 13" =.5" (up to 31.5") 1 = 14.25" 1 = 14" 145 = 14.5" 155 = 15.5" 175 = 17.5" 170 = 17" Cabinet Upper Notch 210 = 21" 200 = 20" A = Uncased 5 =.5" 205 = 20.5" B =.75" (standard) 255 = 25.5" 235 = 23.5" 251 = 25.1" 3
4 A = Width B = Depth C = Height (excluding 3/4" top flange) C HE Series Specifications Supply Opening: (A 1.5") x (B 1.5") Return Opening: (A 1.0") x (B 0.5") A B Slab [1] Number (A,B) 01 (A,B) 02 (A,B) 03 (A,B) 04 (A,B) 05 (A,B) 06 (A,B) 07 (A,B) 08 (A,B) 09 (A,B) 10 (A,B) 11 (A,B) 12 (A,B) 13 Nominal MBTUH [1] E & A = Copper slab; G & B = Aluminum slab. Cased Dimensions Width [A] Depth [B] (1/4" increments) (1/2" Vertical MultiPosition increments) Vert 13.25" 20.00" 13.25" 20.00" 13." 20.25" 13." 20.25" 20.5" 21.5" 20.5" 21.5" 12.5" 13.25"." 13."." 20.5" 21.5" 16.5" 14.25"." 14."." 13.25".75" 13.".75" 14.25".75" 14.".75" 20.5" 21.5" 15.75".75" 16.00".75" 13.25".75" 13.".75" 14.25".75" 14.".75" 15.75".75" 16.00".75" 20.5" 21.5" 20.5" 17.25".75" 17.".75" 14.25".75" 14.".75" 15.75".75" 16.00".75" 20.5" 21.5" 17.25".75" 17.".75" ** 14.25".75" ** 14.".75" ** 15.75".75" ** 16.00".75" 17.25".75" 17.".75" 20.5" 21.5" ** 25.5" 20.25".75" 20.".75" 13.25" 17." 13.25" 21.00" 13." 17.75" 13." 21.25" 20.5" 21.5" 20.5" 21.5" 12.5" 16.5" 13.25" 21.00" 13." 21.00" 20.5" 21.5" 16.5" 14.25" 21.00" 14." 21.00" 14.25".75" 14.".75" 15.75".75" 16.00".75" 14.25".75" 14.".75" 15.75".75" 16.00".75" 20.5" 21.5" 20.5" 17.25".75" 17.".75" 14.25".75" 14.".75" 15.75".75" 16.00".75" 20.5" 21.5" ** 25.5" 17.25".75" 17.".75" Height [C] Multi Pos 16.5" 25.5" 25.5" ** 25.5" 16.5" 16.5" Notes 16.5" 16.5" 16.5".5" 20.5" 20.5" 16.5" ** 25.5" ** If cabinet width is 17" or less for upflow or 17.25" for multiposition, cabinet height must be 27.5". 20.5" 21.5".5" 20.5" 20.5" ** 22.5" height available in H, R & T colors. 4
5 C HE Series Specifications A = Width B = Depth C = Height A B Slab [1] Number (A,B) 01 (A,B) 02 (A,B) 03 (A,B) 04 (A,B) 05 (A,B) 06 (A,B) 07 (A,B) 08 (A,B) 09 (A,B) 10 (A,B) 11 (A,B) 12 (A,B) 13 Nominal MBTUH [1] E & A = Copper slab; G & B = Aluminum slab. [2] Face velocity above 3 ft/min not recommended for downflow applications due to potential water blowoff. CFM Uncased Dimensions and Airflow Data Face Vel. [2] (fpm) Wet Coil Air Pressure Drop (inches W.C.) Pan Coil Copper Slab by Drain Pan Width [A] Depth Height 13" 14" 15.5" 17" 20" 20.5" 23.5" 25.12" [B] [C] Unc Vert MP " 11" 19.5" 13" 19.5" 15" 19.5" 17" 19.5" 19" 19.5" 21" 19.5" 25" 19.5" 11" 19.5" 13" 19.5" 15" 19.5" 17" 19.5" 19" 19.5" 21" Weights Unc Vert Alum Slab MP
6 HE Series Specifications Slab [1] Number (A,B) 14 (A,B) 15 (A,B) 91 (E,G) 20 (E,G) 21 (E,G) 22 (E,G) 23 (E,G) (E,G) 25 (E,G) (E,G) 27 (E,G) (E,G) 31 (E,G) 32 (E,G) 33 (E,G) 34 Nominal MBTUH [1] E & A = Copper slab; G & B = Aluminum slab. Cased Dimensions Width [A] Depth [B] (1/4" increments) (1/2" Vertical MultiPosition increments) Vert 14.25".75" 14.".75" 15.75".75" 16.00".75" 17.25".75" 17.".75" 20.25".75" 20.".75" ** 14.25".75" ** 14.".75" ** 15.75".75" ** 16.00".75" 17.25".75" 17.".75" 20.5" 21.5" ** 25.5" 20.25".75" 20.".75" 25.".75" 13.25" 20.00" 13." 20.25" 21.0" 21.5" 20.5" 21.5" 25.5" 12.5" 13.25" 20.00" 13." 20.25" 20.5" 21.5" ** 16.5" 13.25"." 13."." 20.5" 21.5" 16.5" 14.25"." 14."." 13.25".75" 13.".75" 20.5" 21.5".5" 14.25".75" 14.".75" 15.75".75" 16.00".75" 14.25" 21.00" 14." 21.25" 15.75".75" 16.00".75" 17.25".75" 17.".75" 14.25" 21.00" 14." 21.25" 15.75".75" 16.00".75" 17.25".75" 17.".75" 15.75".75" 16.00".75" 17.25".75" 17.".75" 20.25".75" 20.".75" ** 15.75".75" ** 16.00".75" 17.25".75" 17.".75" 20.25".75" 20.".75" 13.25" 21.00" 13.25" 21.00" 14.25" 21.00" 13." 21.25" 13." 21.00" 14." 21.00" 14.25"." 14.25"." 14."." 14."." 14.25".75" 14.".75" 14.25".75" 14.".75" 15.75".75" 16.00".75" 20.5" 21.5" 20.5" 21.5" ** 25.5" 13.25" 17." 13." 17.75" 20.5" 21.5" 12.5" 20.5" 21.5" ** 16.5" Height [C] Multi Pos ** 25.5" ** 25.5" 16.5" ** 16.5" Notes 20.5" 21.5" 25.5" 25.5" 16.5" 20.5" 20.5" 21.5" 20.5" 20.5" ** 25.5" 20.5" 21.5" ** 25.5" ** 25.5" ** 25.5" ** If cabinet width is 17" or less for upflow or 17.25" for multiposition, cabinet height must be 27.5". Not available in multiposition. ** 16.5" height available in all colors. ** 16.5" ** 14.5" height available in P color (D & ** 25.5" height available in all colors. ** 22.5" height avail in H, R & T colors. ** 21.5" height available in P color (D & ** 16.5" height available in all colors. ** 14.5" height available in P color (D & 20.5" 21.5" 16.5" 16.5" 20.5" 21.5".5" 20.5" 20.5" 21.5" 20.5" 20.5" 16.5" ** 25.5" height available in all colors. **.5" height available in P color (D & ** If cabinet width is 17" or less for upflow or 17.25" for multiposition, cabinet height must be 27.5". 6
7 HE Series Specifications Slab [1] Number (A,B) 14 (A,B) 15 (A,B) 91 (E,G) 20 (E,G) 21 (E,G) 22 (E,G) 23 (E,G) (E,G) 25 Nominal MBTUH [1] E & A = Copper slab; G & B = Aluminum slab. [2] Face velocity above 3 ft/min not recommended for downflow applications due to potential water blowoff. CFM Uncased Dimensions and Airflow Data Face Vel. [2] (fpm) Wet Coil Air Pressure Drop (inches W.C.) Pan Coil by Drain Pan Width [A] Depth Height 13" 14" 15.5" 17" 20" 20.5" 23.5" 25.12" [B] [C] Unc Vert " 23" 19.5" 25" 20" 25" 19.5" 11" 19.5" 13" 19.5" 15" 19.5" 17" 19.5" 19" 19.5" 21" Copper Slab Weights MP Alum Slab Unc Vert MP (E,G) (E,G) 27 (E,G) (E,G) 31 (E,G) 32 (E,G) 33 (E,G) " 23" 19.5" 25" 19.5" 11" 19.5" 13" 19.5" 15" 19.5" 17" 19.5" 19"
8 HE Series Specifications Slab [1] Number (E,G) 35 (E,G) (E,G) 37 (E,G) 41 (E,G) 43 ** (E,G) (E,G) 47 (E,G) (E,G) 49 (E,G) (E,G) 51 (E,G) 52 (E,G) (E,G) 54 (E,G) 55 Nominal MBTUH [1] E & A = Copper slab; G & B = Aluminum slab. Cased Dimensions Width [A] Depth [B] (1/4" increments) (1/2" Vertical MultiPosition increments) Vert 14.25".75" 14.".75" 15.75".75" 16.00".75" 17.25".75" 17.".75" 14.25".75" 14.".75" 15.75".75" 16.00".75" 17.25".75" 17.".75" 20.25".75" 20.".75" ** 14.25".75" ** 14.".75" ** 15.75".75" ** 16.00".75" 17.25".75" 17.".75" 20.25".75" 20.".75" ** 25.".75"." 17.25" 21.00" ** 14.".75" ** 14.75".75" 17.25".75" 17.".75" 20.25".75" 20.".75" 14.25" 17.25" 14.25" 21.00" 17.25".75" 20.5" 21.5" ** 25.5" 20.5" 21.5" ** 25.5" 20.5" 21.5" ** 25.5" 25.".75" 20.5" 21.5" 27.5" 20.5" 21.5" 20.5" 21.5" ** 27.5" Height [C] Multi Pos ** 27.5" 20.75".75" 21.00".75" 20.5" 21.5" 27.5" 27.5" 20.75".75" 21.00".75" 20.5" 21.5" 27.5" 27.5" 20.75".75" 21.00".75" 20.5" 21.5" 31.5" 31.5" 20.75".75" 20.5" 21.5" 31.5" 20.".75" 20.".75" 20.5" 21.5" ** 31.5" 20.".75" 20.'.75" 20.5" 21.5" 31.5" ** 31.5" 31.5" Notes ** 25.5" height available in all colors. ** 22.5" height avail in H, R, & T colors. ** 25.5" ** 21.5" height available in P color (D & ** 25.5" ** 25.5" ** 25.5" height available in all colors. **.5" height available in P color (D & ** If cabinet width is 17" or less for upflow or 17.25" for multiposition, cabinet height must be 27.5". 20.5" 21.5" 25.5" Not available in multiposition. Not available in multiposition. ** E43 3ton not available with HP TXV. 29.5" Not available in multiposition. 17." 21.00" 20.5" 21.5" 29.5" 29.5" ** If cabinet width is 17" or less for upflow or 17.25" for multiposition, cabinet height must be 29.5". Not available in multiposition. 20.5" 21.5" 31.5" Not available in multiposition. ** 31.5" height available in all colors. ** 29.5" height available in P color (D & 8
9 HE Series Specifications Slab [1] Number (E,G) 35 Nominal MBTUH [1] E & A = Copper slab; G & B = Aluminum slab. [2] Face velocity above 3 ft/min not recommended for downflow applications due to potential water blowoff. CFM Uncased Dimensions and Airflow Data Face Vel. [2] (fpm) Wet Coil Air Pressure Drop (inches W.C.) Pan Coil by Drain Pan Width [A] Depth Height 13" 14" 15.5" 17" 20" 20.5" 23.5" 25.12" [B] [C] Unc Vert " 21" Copper Slab 39 Weights MP Alum Slab Unc Vert 31 MP (E,G) (E,G) 37 (E,G) 41 (E,G) 43 ** (E,G) (E,G) 47 (E,G) (E,G) 49 (E,G) (E,G) 51 (E,G) 52 (E,G) (E,G) 54 (E,G) 55 ** " 23" 19.5" 25" 20" 25" 20" 27" 19.5" 29" 19.5" 27" 19.5" 27" 19.5" 25" 19.5" 27" 19.5" 29" 19.5" 31" 19.5" 31" 19.5" 29" 19.5" 31"
10 HE Series Specifications Slab [1] Number (E,G) 56 (E,G) 57 (E,G) 65 Nominal MBTUH [1] E & A = Copper slab; G & B = Aluminum slab. Cased Dimensions Width [A] Depth [B] (1/4" increments) (1/2" Vertical MultiPosition increments) Vert." 20.5" 21.5" 27.5" 20.75".75"." 20.5" 21.5" 31.5" Height [C] (E,G) 70." 20.5" 21.5".5" Not available in multiposition. Multi Pos Notes Not available in multiposition ".75" 20.5" 21.5" 27.5" 27.5" Not available in multiposition. (E,G) 71." 20.5" 21.5" ** 25.5" Not available in multiposition. ** 25.5" height available in all colors. ** 22.5" height avail in H, R, & T colors. ** 21.5" height available in P color (D & (E,G) 72." 20.5" 21.5" ** 25.5" (E,G) 73 (E,G) 74."." 20.5" 21.5" 20.5" 21.5" 25.5".5" Not available in multiposition. Not available in multiposition. (E,G) 75." 20.5" 21.5" ** 25.5" (E,G) 76." 20.5" 21.5" ** 25.5" Not available in multiposition. ** 25.5" height available in all colors. **.5" height available in P color (D & Not available in multiposition. ** 25.5" height available in all colors. ** 22.5" height avail in H, R, & T colors. ** 21.5" height available in P color (D & Not available in multiposition. ** 25.5" height available in all colors. **.5" height available in P color (D & (E,G) 77." 20.5" 21.5" 25.5" Not available in multiposition. 10
11 HE Series Specifications Slab [1] Number (E,G) 56 (E,G) 57 (E,G) 65 (E,G) 70 Nominal MBTUH [1] E & A = Copper slab; G & B = Aluminum slab. [2] Face velocity above 3 ft/min not recommended for downflow applications due to potential water blowoff. CFM Uncased Dimensions and Airflow Data Face Vel. [2] (fpm) Wet Coil Air Pressure Drop (inches W.C.) Pan Coil by Drain Pan Width [A] Depth Height 13" 14" 15.5" 17" 20" 20.5" 23.5" 25.12" [B] [C] Unc Vert " 27" 19.5" 27" 19.5" 31" 19.5" 19" Copper Slab Weights MP 72 Alum Slab Unc Vert MP 58 (E,G) " 21" (E,G) " 23" (E,G) 73 (E,G) " 25" 19.5" 19" (E,G) " 21" (E,G) " 23" (E,G) " 25"
12 HE Series Specifications Slab [1] Number Nominal MBTUH [1] E & A = Copper slab; G & B = Aluminum slab. Cased Dimensions Width [A] Depth [B] (1/4" increments) (1/2" Vertical MultiPosition increments) Vert 14.25" 21.00" 14." 21.00" Height [C] (E,G) "." 14.25"." 14."." 14."." 20.5" 21.5" 20.5" 20.5" 14.25".75" 14.".75" (E,G) ".75" 14.".75" 20.5" 21.5" 20.5" 20.5" 14.25".75" 14.".75" 14.25".75" 14.".75" ** 25.5" height available in all colors. (E,G) ".75" 14.".75" 20.5" 21.5" ** 25.5" ** 25.5" ** 22.5" height available in H, R, & T 14.25".75" 14.".75" colors ".75" 14.".75" (E,G) ".75" 14.".75" 20.5" 21.5" 25.5" 25.5" 14.25".75" 14.".75" 17.25".75" 17.".75" (E,G) ".75" 17.".75" 20.5" 21.5" 25.5" 25.5" 20.75".75" 21.00".75" 14.25".75" 14.".75" (E,G) ".75" 14.".75" 20.5" 21.5" 27.5" 27.5" 14.25".75" 14.".75" 17.25".75" 17.".75" (E,G) ".75" 17.".75" 20.5" 21.5" 27.5" 27.5" 20.75".75" 21.00".75" ** 14.25".75" ** 14.".75" (E,G) 87 ** 14.25".75" ** 14.".75" 20.5" 21.5" ** 27.5" ** 27.5" ** 14.25".75" ** 14.".75" ** 17.25".75" 17.".75" (E,G) 88 ** 17.25".75" 17.".75" 20.5" 21.5" ** 27.5" ** 27.5" ** 20.75".75" 21.00".75" Multi Pos Notes ** If cabinet width is 20.75" or less for upflow or multiposition, cabinet height must be 29.5". ** If cabinet width is 20.75" or less for upflow or multiposition, cabinet height must be 29.5". 12
13 HE Series Specifications Slab [1] Number (E,G) 80 (E,G) 81 (E,G) 82 (E,G) 83 (E,G) 84 (E,G) 85 (E,G) 86 (E,G) 87 (E,G) 88 Nominal MBTUH [1] E & A = Copper slab; G & B = Aluminum slab. [2] Face velocity above 3 ft/min not recommended for downflow applications due to potential water blowoff. Uncased Dimensions and Airflow Data Wet Coil Air Pressure Drop (inches W.C.) by Drain Pan Width [A] Face Pan Coil Copper Slab CFM Vel. [2] Depth Height 13" 14" 15.5" 17" 20" 20.5" 23.5" 25.12" Unc (fpm) [B] [C] Vert MP " 17" 19.5" 19" 19.5" 21" 19.5" 23" 19.5" 23" 19.5" 25" 19.5" 25" 19.5" 27" 19.5" 27" Weights Alum Slab Unc Vert MP
14 HE Series Pallet Quantities Cabinet Width Cased Pallet Qty by Cabinet Height (in) " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
15 HE Series Pallet Quantities Drain Pan Width Uncased Pallet Qty by Coil Height (in) " " " " " " " "
16 HH Series Features & Nomenclature Product Features High efficiency lanced fin design. Nohassle 5 year warranty. R410A, R22, A/C & heat pump compatible. All coils have durable packaging with bar coded labels on the box. Threaded expansion valves available factory installed or as a field installed kit. Coils are air pressure tested at 0 psi, leak tested with helium, sealed with rubber plugs, then charged with dry air. Piston options include externally accessible body for easy piston change out and/or TXV installation. Liquid line refrigerant connections are 3/8" ODF. Suction line refrigerant connections are 7/8" ODF. Nomenclature H H52 2 A 225 A H = Embossed Piston Size [1] AP = TXV Access Port [2] Slab Number MBTUH R22 R410A 12 = Metering Device = 49 1 = Piston (R410A) = 59 2 = Piston (R22) = = Bleed A/C TXV (R22) = = Non Bleed A/C TXV (R22) = = Non Bleed HPA/C TXV (R22) = = Non Bleed A/C TXV (R410A) = = Non Bleed HPA/C TXV (R410A) [1] Piston will always be sized to match the nominal BTU rating of the coil. Nominal MBTUH [2] TXV access port standard on factory installed TXVs; optional on piston models. Cabinet Depth A = 10" Note: Fixed, not a selectable option. Product Code 02 = Cased "H" Cabinet Opening Width 5 = 5/8" Cabinet Opening Height 225 = 22 5/8" Note: Cabinet opening width is not a 17 = 17 1/4" Note: Cabinet opening height is not a 5 = 5/8" selectable option; see dimensions. 21 = 21 1/4" selectable option; see dimensions. 5 = 5/8" 5 = 5/8" A = Bidirectional airflow 5 = 5/8" 16
17 HH Series Specifications A C B A = Height B = Width C = Depth (excluding flange) Supply Opening: (A 1.") x (B 4 3/8") Return Opening: (A 1.") x (B 4 3/8") Slab Num H H41 H H43 H Dimensions 32 Slab Number Overall Supply/Return Opening H45 Height [A] Width [B] Depth [C] Height Width H H 3/4" 23" 10" 17 1/4" 5/8" H47 H, H45 3/4" 27" 10" 17 1/4" 22 5/8" H H41, H 3/4" 31" 10" 17 1/4" 5/8" H49 H, H47 3/4" 35" 10" 17 1/4" 5/8" H H43, H 3/4" 41" 10" 17 1/4" 5/8" H51 H49 3/4" 47" 10" 17 1/4" 5/8" H52 H, H51, H56, H /4" 23" 10" 21 1/4" 5/8" H H52, H /4" 27" 10" 21 1/4" 22 5/8" H54 H, H /4" 31" 10" 21 1/4" 5/8" H55 H54, H 22 3/4" 35" 10" 21 1/4" 5/8" H56 H55, H /4" 41" 10" 21 1/4" 5/8" H57 H62, H /4" 47" 10" 21 1/4" 5/8" H58 H59 H H61 H62 H66 Weight / Pallet Qty Weight (lbs) Pallet Quantity Airflow Data Slab Number Wet Coil Air Pressure Drop (Inches W.C.) by CFM H H, H H41, H H, H H43, H H H, H H51, H H52, H H, H H54, H H55, H H H
18 LA/LH Series Features & Nomenclature Product Features Patented lanced fin design. R410A, R22, A/C and heat pump compatible. Dual 3/4" FPT condensate drains. Liquid line refrigerant connections are 3/8 ODF. Suction line refrigerant connections are 7/8 ODF. Dual circuit coils have row split circuiting allowing full coil surface to be active when 1 or 2 circuits are operating. Factory installed TXV valves. Up or down airflow compatible. Coils are air pressure tested at 0 psi, leak tested with helium, sealed with rubber plugs, then charged with dry air. Drain pans are constructed of aluminum to resist corrosion. Heavy gauge embossed galvanized cabinets fully lined with 1/2" insulation. Left hand drain and refrigerant connections. All coils are individually packaged on skids. Nomenclature LA 6 1 AC Large Capacity Coil Refrigerant LA = "A" Coil blank = R22 LH = Horizontal Slab Coil 4 = R410A Tonnage Number of Circuits Application AC = Air Conditioning AC/HP = Air Conditioning & Heat Pump Note: Engineering must verify internal volume for heat pumps. Application "A" Coils "H" Coils Dual Circuit Single Circuit Single Circuit Model LA 6 2 AC LA 8 2 AC LA 10 2 AC LA AC/HP LA AC Number of Circuits (2) 1 1/2 3 tons ea. [1] (2) 3 1/2 4 tons ea. [1] (2) 3 1/2 5 tons ea. [1] (1) 6 7 1/2 tons (1) 7 1/2 10 tons Application Air Conditioning Only Air Conditioning Only Air Conditioning Only Air Conditioning or Heat Pump [2] Air Conditioning Only LH AC/HP (1) 6 7 1/2 tons Air Conditioning or Heat Pump [2] [1] May be manifolded together in the field to form one circuit. [2] Engineering must verify internal volume compatibility for heat pumps.
19 LA/LH Series Specifications Dimensions and Weights Model Cased LA Width Depth Height LA 6 29" 21.5".5" LA " 21.5".5" LA 8 35" 21.5".5" LA 10 " 21.5".5" LA " 21.5" 22.5" Model Uncased LA Width Depth Height LA " 21".5" LA " 21".5" LA " 21".5" LA " 21".5" LA " 21" 20.5" Model Cased LH Width Depth Height LH " 47" 22.75" Duct Connections N/A.63" 21.25" Weight Weight Weight 75 Airflow Data Wet Coil Air Pressure Drop (Inches W.C.) by CFM Model LA LA 7.5 & LA LA LH
20 2175 West Park Place Boulevard Stone Mountain, GA 087
HE, HH, LA/LH Series Evaporator Coils
SGHAC32 May 2013 HE, HH, LA/LH Series Evaporator Coils Specification Guide Contents... Pa Page HE Series ACoils Features... 2 Nomenclature... 3 Specifications... 4 Pallet Quantities... 14 HH Series Horizontal
More informationHE Series Evaporator Coils
SG-HE-01 February 2017 Specification Guide HE Series Evaporator Coils Contents... Page HE Series A-Coils Features... 2 Nomenclature... 3 Specifications... 4 Pallet Quantities... 12 Product improvement
More informationHE Series Evaporator Coils
SG-HE-02 March 20 Specification Guide HE Series Evaporator Coils Contents... Page HE Series A-Coils Features... 2 Nomenclature... 3 Specifications... 4 Pallet Quantities... 12 Product improvement is a
More informationEVAPORATOR COILS PRODUCT SPECIFICATIONS EAC4X EAC1P EAU1P EAH1P EVAPORATOR COILS FEATURES
PRODUCT SPECIFICATIONS EVAPORATOR COILS FEATURES Microban antimicrobial additive in the drain pan to resist mold and mildew growth. Aluminum tubing, hairpins, distributors and header tubes. Copper refrigerant
More informationPage Number. Contents: Product Features 2. Physical Data 2. Nomenclature. 3. Blower Performance 3. Electrical Data 4. Warranty.. 6
TC-SGRAH1-1005 October 05 R Series - High Efficiency Multi-position Air Handler Engineering and Specification Guide (Electric and No Heat) With optional field conversion downflow kit Contents: Page Number
More informationB Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor
SG-BAH-16 February 2014 Specification Guide B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor Contents Page Product Features
More informationBCE3 PRODUCT SPECIFICATIONS STANDARD AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY
PRODUCT SPECIFICATIONS STANDARD AIR HANDLER FORM NO. -100 (05/2014) APPLICATION 1 1/2-5 ton systems Upflow and horizontal (counterflow capable with kits) Sequenced for demand management External access
More informationBC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat)
BCAHSG-2 3-Jun BC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat) 5 YEAR WARRANTY see warranty form for details Contents: Page Number Product Features 2
More information1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5
TABLE OF CONTENTS 1. Air Handler Features Page 2 2. Physical data Page 3 3. Available kits Page 4 4. Model nomenclature Page 5 5. Air handler blower performance Page 6 6. heating capacity Page 12 7. Maximum
More informationBCS2**V. Enhanced Air Handler APPLICATION INSTALLATION CABINET ACCESSORIES COMPONENTS
Enhanced Air Handler BCS2**V APPLICATION 2-5 ton sizes Upflow and horizontal (counterflow capable with kit) Sequenced for demand management External access to heater circuit breakers INSTALLATION 1 Piece
More informationBCS2S. Product Specifications ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS ACCESSORIES.
Product Specifications ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION 2-5 ton sizes Upflow and horizontal (counterflow capable with kit) Sequenced for demand management External access to heater
More informationBCS2V PRODUCT SPECIFICATIONS AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY
PRODUCT SPECIFICATIONS AIR HANDLER FORM NO. -100 (12/2013) APPLICATION 2-5 ton sizes Upflow and horizontal (counterflow capable with kit) Sequenced for demand management External access to heater circuit
More informationBCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY
PRODUCT SPECIFICATIONS APPLICATION 2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (11/2018) INSTALLATION One piece design Smaller profile for closet
More informationBCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY
PRODUCT SPECIFICATIONS APPLICATION 1 1/2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (12/2018) INSTALLATION 1 piece design Smaller profile for
More informationBCE3V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY
PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER FORM NO. -100 (03/2017) APPLICATION 1.5-5 ton systems Upflow and horizontal Sequenced for demand management External access to heater circuit breakers INSTALLATION
More informationCAPF, CAUF, CHPF, & CSCF DUAL-REFRIGERANT SERIES
CAUF Uncased Horizontal Slab CASED, PAINTED UPFLOW/ DOWNFLOW, UNCASED UPFLOW/ DOWNFLOW, HORIZONTAL A & HORIZONTAL SLAB INDOOR COILS CAPF Cased Horizontal A CAPF, CAUF,, & DUAL-REFRIGERANT SERIES Goodman
More informationINDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS CX34 PRODUCT SPECIFICATIONS Upflow - Cased - R-410A Bulletin No. 210322 August 2011 Supersedes August 2010 MODEL NUMBER IDENTIFICATION 18/24 = 1.5/2 tons 30 = 2.5 tons 31 = 2.5 tons 36 = 3
More informationDual-Refrigerant Coils
Dual-Refrigerant Coils CAPF, CAUF,, & Product Specifications Goodman brand coils are designed for use with Goodman brand gas furnaces, split system air conditioners and heat pumps, as well as modular,
More informationTECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: CF, CM, CU 600-2000 CFM 1.5-5 TON COILS 5005744-BTG-C-0815 DESCRIPTION These indoor coils are designed to be installed
More informationRCBA- MULTIFLEX INDOOR COILS
FORM NO. C11-207 REV. 3 Supersedes Form No. C11-207 Rev. 2 RCBA- MULTIFLEX INDOOR S AIRFLOW CAPACITIES 600-2000 CFM [218-944 L/s] Rheem Value Series Indoor Coils are designed for use with Rheem Value Series
More informationIndoor Coils. CAUF, CAPF, CAPT, CHPF, and CSCF. Cased, Painted Upflow/Downflow, Uncased Upflow/Downflow, Horizontal A, and Horizontal Slab
Indoor Coils CAUF, CAPF, CAPT,, and CSCF Cased, Painted Upflow/Downflow, Uncased Upflow/Downflow, Horizontal A, and Horizontal Slab CAUF Uncased Horizontal A CAPF Cased Standard Features All-Aluminum evaporator
More informationIndoor Coils. CAUF, CAPF, CAPT, CHPF, and CSCF. Cased, Painted Upflow/Downflow, Uncased Upflow/Downflow, Horizontal A, and Horizontal Slab
Indoor Coils CAUF, CAPF, CAPT,, and CSCF Cased, Painted Upflow/Downflow, Uncased Upflow/Downflow, Horizontal A, and Horizontal Slab CAUF Uncased Horizontal A CAPF Cased Standard Features All-Aluminum evaporator
More informationA I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S
P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric
More informationARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features
Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit
More informationTECHNICAL SUPPORT MANUAL Coils for Manufactured Housing EMA2X, EMA4X
Coils for Manufactured Housing EMA2X, EMA4X DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER
More informationProduct Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES
Product Data CC5A, CD5A Heating/Cooling Coil Sizes A018 thru W060 The CC5A and CD5A evaporator coils incorporate proven standards for reliable system operation and performance throughout the life of a
More informationASPT Multi-Position Air Handler
Multi-Position Air Handler with Energy-Saving Motor ½ to Tons Standard Features Direct-drive, multi-speed ECM motor Internal factory-mounted TXV valve Transformer and blower time-delay on all units All-Aluminum
More informationINDOOR COILS RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR COILS. AIRFLOW CAPACITIES CFM [ L/s]
FORM NO. C22-206 REV. 14 Supersedes Form No. C22-206 Rev. 13 INDOOR S RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR S AIRFLOW CAPACITIES 600-2000 CFM [218-944 L/s] Ruud Indoor Coils are designed
More informationIndoor Coils. CAUF, CAPF, CAPT, CHPF, and CSCF. Cased, Painted Upflow/Downflow, Uncased Upflow/Downflow, Horizontal A, and Horizontal Slab
Indoor Coils CAUF, CAPF, CAPT,, and CSCF Cased, Painted Upflow/Downflow, Uncased Upflow/Downflow, Horizontal A, and Horizontal Slab CAUF Uncased Horizontal A CAPF Cased Standard Features All-Aluminum evaporator
More informationARUF. 1½ to 5 Tons. O when tested in accordance with ASHRAE standard 193 Cabinet air leakage less than 1.4% at 0.5 inch H 2
Multi-Position Air Handler with New SmartFrame Construction ½ to 5 Tons Standard Features All-aluminum evaporator coil Check flowrater expansion device for cooling-only and heat pump applications Direct-drive,
More informationHMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS HMG*T Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG*T series of air handlers, when combined with our heat pump or air conditioner, offer
More informationB6BMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS B6BMMX Series Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The B6BMMX series of air handlers, when combined with our heat pump or air conditioner,
More informationAVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.
Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...
More informationCased/Uncased Coils For Gas And Oil Furnaces
MODEL: TCF Cased/Uncased Coils For Gas And Oil Furnaces FORM NO. CSC-224 REV. 1 Sure Comfort TCF Cased/Uncased Coils For Gas And Oil Furnaces (TXV Metering Device Shown) Featuring Industry Standard R-410A
More informationModular Variable Speed Air Handlers
Modular Variable Speed Air Handlers Convertible Variable Speed Communicating Air Handlers - 1 1/2-5 Ton 4TEE3C01A1000A 4TEE3C02A1000A 4TEE3C03A1000A 4TEE3C04A1000A 4TEE3C05A1000A 4TEE3C06A1000A 4TEE3C07A1000A
More informationARUF. Multi-Position Air Handler. 1½ to 5 Tons. Construction
½ to 5 Tons Multi-Position Air Handler with new SmartFrame Construction Standard Features All-aluminum evaporator coil Check flowrater expansion device for cooling-only and heat pump applications Direct-drive,
More informationINDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS
More informationHMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS HMG Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG Series of air handlers, when combined with our heat pump or air conditioner,
More informationINDOOR COILS. RCFM- featuring New Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-212 REV. 4 Supersedes Form No. C11-212 Rev. 3 INDOOR COILS RCFM- featuring New Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY
TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable
More informationAir Handlers. ACBX32CM 3 Phase Multi-Position FEATURES AND BENEFITS. Application. Components. Cabinet. Accessories. Warranty ACBX32CM-100 (07/2011)
Air Handlers ACBX32CM 3 Phase Multi-Position ACBX32CM-100 (07/2011) FEATURES AND BENEFITS Application Environmentally friendly R410A refrigerant 3, 4, and 5 ton nominal capacities Multi-position applications
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFP- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,600 CFM [283-755 L/s] Rheem Indoor Coils are designed for use
More informationARPT. Multi-Position 1½ to 5 Tons Construction
Multi-Position ½ to 5 Tons Air Handler with new SmartFrame Construction Standard Features Direct-drive, multi-speed motor Internal factory-mounted TXV valve Transformer and blower time-delay on all units
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Ruud Indoor Coils are designed for use
More informationELITE SERIES R-410A Ready - Multi-Position
PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER
More informationTECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION
TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationRheem High Efficiency Air Handler
Air Handlers Rheem High Efficiency Air Handler /RHT- Series Constant Torque (ECM) Efficiencies up to 16 SEER /RHT feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFN- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Ruud Indoor Coils are designed for use
More informationB6EMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS 6EMMX Series Air Handler with TXV 14-15 SEER Residential System 18,000-60,000 tuh (Heat Pump & Air Conditioner) R-410A Refrigerant The 6EMMX Series of air handlers, when combined
More informationTECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE
TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationTECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: MC, PC, FC, HD, UC CFM 1.
Heating TECHNICAL GUIDE Air Conditioning ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, UC 600-2000 CFM 1.5-5 TON COILS R DESCRIPTION These cooling and heat pump
More informationARUF PRODUCT SPECIFICATIONS AIR HANDLER 1½ TO 5 TONS MULTI-POSITION, THREE-SPEED WITH GALVANIZED CABINET
AIR HANDLER WITH GALVANIZED CABINET The Multi-Position Air Handler is suitable for use with refrigerants R-410A and R-22. This unit features a check flowrater expansion device and may be installed in a
More informationCASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. CFJ-224 Supersedes Form No. PTZ-789 CASED/UNCASED COILS FOR GAS AND OIL FURNACES FCC SERIES featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] (TXV Metering
More informationBAC / BHC Product Specifications
COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves
More information2015 A Series Catalog
Millhaven,Ontario Plant 2015 A Series Catalog 5055 Taylor Kidd Blvd. Millhaven, Ontario Canada, K0H 1G0 TEL: (613) 544-2200 FAX: (613) 544-7779 28 D-VAC Sales Inc. US, Northeast Sales & Engineering Office
More informationDESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System
Heating TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, UC 600-2000 CFM 1.5-5 TON COILS UPFLOW/DOWNFLOW FULL CASED FC UPFLOW PARTIAL CASED PC Air Conditioning
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCF- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] (TXV Metering Device Shown) Ruud Indoor
More informationAir Handler Accessories & Replacement Parts
PS-ARP-18 Effective: May 9, 2012 Price Sheet Air Handler Accessories & Replacement Parts Accessories - All Air Handlers Part Num List Price A/C TV R-22 (bleed) 655400 69 12-37 #3 designation in nomenclature
More informationMedium Profile Unit Coolers
CH-MPTB JAN 2018 Replaces CH-MPTB AUG 2016 Medium Profile Unit Coolers Technical Guide s HMA HME/HML HMG/HMF Table of Contents Nomenclature... 2 Features & Benefits... 3 Performance Data & Specifications...
More informationDESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System
TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, UC 600-2000 CFM 1.5-5 TON COILS UPFLOW/DOWNFLOW FULL CASED FC UPFLOW PARTIAL CASED PC UPFLOW UNCASED
More informationB6VMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler with TXV 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS 6VMMX Series Air Handler with TXV 18,000-60,000 tuh (Heat Pump & Air Conditioner) The 6VMMX Series of air handlers, when combined with our heat pump or air conditioner, offers
More informationINDOOR COILS RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR COILS. AIRFLOW CAPACITIES CFM [ L/s]
FORM NO. C11-206 REV. 13 Supersedes Form No. C11-206 Rev. 12 INDOOR S RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR S AIRFLOW CAPACITIES 600-2000 CFM [218-944 L/s] Rheem Indoor Coils are designed
More informationTECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: GHD, GFD, GFA, GNA, GUA & GHA CFM 2-5 TON COILS
Heating TECHNICAL GUIDE Air Conditioning ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: GHD, GFD, GFA, GNA, GUA & GHA 600-2000 CFM 2-5 TON COILS R DESCRIPTION These cooling and heat
More informationAppendix A. Cooling Coil
Appendix A COILS FOR RUN-AROUND HEAT RECOVERY SYSTEM Cooling Coil Model number D--B45 Coil Information Tag Exhaust Wint Actual airflow Quantity System type 1 Chilled Water Entering dry bulb Entering wet
More informationMEDIUM PROFILE UNIT COOLERS Technical Guide. Models HMA Air Defrost HME/HML Electric Defrost HMG/HMF Hot Gas Defrost.
CH-MPTB June 2015 Replaces CH-MPTB Nov 2010 MEDIUM PROFILE UNIT COOLERS Technical Guide s HMA Air Defrost HME/HML Electric Defrost HMG/HMF Hot Gas Defrost heatcraftrpd.com Table of Contents Nomenclature...2
More informationMERIT Series R-410A - Upflow / Horizontal - Variable Speed
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UHV (-01) MERIT Series R-10A - Upflow / Horizontal - Variable Bulletin No. 10611 March 015 Supersedes November 01 MODEL NUMBER IDENTIFICATION CB X 5 UH V - 00-0
More informationMulti-Position Air Handler. 1½ to 5 Tons. with Energy-Saving Motor
Multi-Position Air Handler with Energy-Saving Motor ½ to Tons Standard Features Suitable for use with refrigerants R-0A and R- All-aluminum evaporator coil Check flowrater expansion device for cooling
More informationProduct Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES
Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air
More informationMEDIUM PROFILE UNIT COOLERS Technical Guide
BN-MPTB August 2016 Replaces BN-MPTB, June 2015 MEDIUM PROFILE UNIT COOLERS Technical Guide s BMA Air Defrost BME/BML Electric Defrost BMG/BMF Hot Gas Defrost heatcraftrpd.com Table of Contents Nomenclature...2
More informationProduct Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits
More information12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT
Service Literature Corp. 9711 L7 CB29M CB30M ELITE 10 CB29M and ELITE 12 CB30M SERIES UNITS INCLUDING ECB29 The Elite 10 CB29M and Elite 12 CB30M are high efficiency blower coils. Several models are available
More informationPrecision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz
Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0
More informationPA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE
PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on
More informationProduct Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES
LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air
More informationProduct Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES
FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system
More informationi Series Model SV Water Source Heat Pump 1/2 to 6 Ton
i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features
More informationARUF Series Multi-Position
Series Multi-Position Multi-speed Psc Motor Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed PSC blower motor All-aluminum evaporator coil Coil mounting
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS 23 SEER Residential System Indoor Section M1200 Product Line PAH2VM Series Variable Speed Air Handler C6 Series Residential Indoor Coils with EXV 2 M1200 12 YEAR ALL PARTS LIMITED
More informationProduct Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP
FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low
More informationRheem High Efficiency Air Handler
Air Handlers Rheem High Efficiency Air Handler Constant Torque Motor (ECM) Efficiencies up to 14 SEER The RH1T feature a Constant Torque motor (ECM) and a piston refrigerant control for efficient and reliable
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Upflow/Downflow Cased Coils Cooling and Heat Pump Compatible Factory Installed R-410A Metering Device RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION WARNING
More informationELITE Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX7UH ELITE Series R-0A - Upflow / Horizontal Bulletin No. 08 March 0 Supersedes October 0 Nominal Capacity -. to Tons Optional Electric Heat -. to kw MODEL NUMBER
More informationAIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-517 REV. 1 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5.3 kw] through 5 ton [17.6 kw] models are always just
More informationR-22, 13 SEER 60 Hertz
TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point
More informationAPARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS
FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS 1½ THRU 3 TONS FEATURES TXV metering device factory installed
More informationPA55 10 SEER FEATURES 2 THRU 5 TON SINGLE PACKAGE AIR CONDITIONER
PACKAGE AIR CONDITIONER PA55 10 SEER C 2 THRU 5 TON SINGLE PACKAGE AIR CONDITIONER FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationProduct Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES
FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)
FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES
TEHNIAL GUIDE SINGLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLING & HEAT PUMPS MODELS: AHP18 THRU 60 AND SHP48 THRU 60 DESRIPTION This fan coil line offers the ultimate in application flexibility.
More informationM-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE
ELECTRIC HEAT PUMP PACKAGED UNITS MHP4 FORM NO. MHP4-100 (10/2018) MODEL NUMBER GUIDE 3 M HP 4 11 18 1 F P 1 FACTORY INSTALLED ELECTRIC HEAT 3= 3 KW 5 = 5 KW 7 = 7 KW 10 = 10 KW M = MAGIC-PAK HP = HEAT
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS 24.5 SEER Residential System Indoor Section M1200 Product Line PAH4VM Series Variable Speed Air Handler C6 Series Residential Indoor Coils with EXV 2 M1200 12 YEAR ALL PARTS LIMITED
More informationProduct Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES
Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationi Series Model SV Water Source Heat Pump 1/2 to 6 Ton
i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features
More informationProduct Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz
18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz Product Data 07 --- 12 C09035 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-position design
More informationBHH Product Specifications
BHH Product Specifications HORIZONTAL BELT DRIVE DIRECT EXPANSION BLOWER COIL UNITS ALL S 3, 4, and 5 Ton 208/230 3 60 and 460 3 60 supply voltage Units are ETL listed to U.S. and Canadian safety standards
More information