Level Probes multicap DC 11/16/21/26 EN multicap DC 11/16/21/26 ES

Similar documents
Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Level Probes multicap T DC 12 TA multicap T DC 11/16/21/26 TAN/TAS

Level Probe multicap DC 16

Level Limit Switch liquiphant FTL 365 / FTL 366

Level Limit Switch liquiphant FTL 360 / FTL 361

Level Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S)

Level limit switch Series RF 3000 Selection list

Soliphant II FTM30(D/S)/31(D/S)/32(D/S)

Vibration Limit Switch liquiphant M FTL 51 C

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level Limit Switch soliphant FTM 930/931/932/ Z

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Continuous level measurement Capacitance transmitters

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Rod probe 11375Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Liquicap M FTI51, FTI52

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Point level measurement Capacitance switches

Metal tube variable area flowmeter for gases, liquids and steam

Solicap M FTI55, FTI56

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

SITRANS T measuring instruments for temperature

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

Level Measurement Continuous level measurement - Capacitance transmitters

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Control Valve fluids with integrated positioner. GS 3 series - DN 15 up to DN 250. material

p Additional dimensions see section dimensions.

OPTISWITCH 4000/5000. Vibration level switches for liquids

Thermowell for temperature sensors omnigrad M TW 13

ORIMAS Mass Flowmeter

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

SATRON VDt Differential Pressure Transmitter

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Hydrostatic. Continuous level measurement. Overview Page 186 VEGABAR series 60 Page 188 VEGAWELL 52 Page 192 Accessory Page 194.

Hydrostatic. Overview 192 VEGABAR series VEGAWELL Accessory 200. Hydrostatic VEGABAR series 60 and VEGAWELL

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

RTD Temperature Sensor omnigrad M TR 15

STEEMCO-MAS Flowmeter for Steam

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Overview. Specifications. Applications

Process pressure. Overview 168 VEGABAR series VEGABAR series Accessory 184. Process pressure VEGABAR

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

STEEMCO Flowmeter for Steam

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits

Micro Motion F-Series Coriolis Flow and Density Meters

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

RTD Temperature Sensor omnigrad M- TR 13

NIVOSWITCH R-400/R-500

RHM04. Compact Coriolis Flow Sensor With Enhanced Performance. Features. Applications. Benefits

Plastic tube variable area flowmeter for liquids and gases

FS10. Vertically-Mounted Magnetic Float Level Sensor. Level Measurement and Monitoring. reliable and robust, heavy-duty technology

Level Measurement Point level measurement - RF Capacitance switches

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Thermocouple Without thermowell Model TC10-H

Thermocouple insert for Temperatur Sensor omniset- TPC 100

Deltapilot S DB50A/50S/51A/52A/53A

RHM015. Ultimate Performance Coriolis Mass Flow Meter for Critical Ultra Low Flow Applications. Features. Applications. Benefits

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Flow Measurement SITRANS F M

SITRANS F M. Flow sensor MAG 1100 F 3/59

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

RTD Temperature Sensor omnigrad T -TR 470

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

RHM08. Versatile Coriolis Mass Flow Meter. Features. Applications. Benefits

Resistance thermometer Without thermowell Model TR10-H

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

SATRON VT Pressure Transmitter

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Magnetic Float Switches horizontal 1003-h

BM 26 BASIC/ADVANCED Technical Datasheet

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Level Sensor with G1/2" Thread Hygienic

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Level Sensor with M12 Thread Hygienic

Flow Measurement SITRANS F M

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Ultrasonic Measurement prosonic FDU 80 86

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

JUMO dtrans p20 DELTA

Pressure Transmitter cerabar S PMC 731, PMP 731

Level limit switch Series RN 3000 / 6000 Selection list. Overview. Specifications. Applications

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Level limit switch Series RN 3000 / 6000 Selection list

Magnetic-inductive flow meter for hazardous areas

Differential Pressure Gauges (701P Series)

Transcription:

Technical Information TI 242F/00/en Level Probes multicap DC 11/16/21/26 EN multicap DC 11/16/21/26 ES Fully and partially insulated rod and rope probes for capacitive level measurement and limit detection (European certificates) Application Multicap probes are designed for continuous level measurement and limit detection, primarily in liquids. The DC 11 and DC 16 rod probes are also suitable for use in light bulk solids. The probe rod or probe rope and insulation are made of corrosion-resistant materials able to withstand extremely aggressive products. The tried-and-tested rugged construction is gas-tight for pressure from vacuum to bar. Seal and insulation materials enable probes to be used at operating temperatures in the vessel of 80 to +200. Features and Benefits Certificates from many European approval authorities = the probes have universal use Versions for a wide range of applications = ideally adapted to your application at a cost effective price Screened against condensation in the nozzle = reliable function even with condensation Active build-up compensation for limit detection = steady and accurate switchpoint even with heavy contamination on the probe, no cleaning or recalibration Endress +Hauser The Power of Know How

Measuring System Left: Limit detection with separate Nivotester switching unit Right: Level measurement with separate Silometer transmitter Nivotester FTC... EC 17 Z EC 37/47 Z Silometer FMC... Left: Compact level switch with relay or transistor output Right: Compact level measurement system with standard 4 20 ma current output and superimposed communications signal. FEC 12: Smart electronic insert which allows remote calibration over two-wire cabling (HART protocol) FEC 14: Communication and commissioning with PROFIBUS PA FEC 22 Probe Selection Connection module: - with RFI filter for EC.. Z or FEC 12 (EEx ia) (2-pole) - for FEC 12 (EEx d) (2-pole) - for FEC 14 (2-pole) - for FEC 22 (AC: 8-pole) for FEC 12 FEC 14 FEC 22 Type: T3 aluminium housing with separate connection compartment to EEx d/eex ia version for EC 17 Z EC 37 Z EC 47 Z Electronic insert EC 17 Z EC 37 Z EC 47 Z Electronic insert FEC 12: 4... 20 ma Smart FEC 14: PROFIBUS PA Profile 3.0 Electronic insert FEC 22: Compact limit switch 1) 2) 3) 4) 5) 6) 7) 8) 1) DC 11 EN with fully insulated rod 2) DC 16 EN with partially insulated rod 3) DC 21 EN with fully insulated rope 4) DC 26 EN with partially insulated rope 5) DC 11, 21 ES with fully insulated screening against condensation or material build-up at the process connection 6) DC 11, 16, 21, 26 ES with uninsulated screening against condensation or material build-up at the process connection 7) DC 11, 16, 21, 26 ES with active compensation of conductive material build-up at the probe 8) DC 11, 16, 21, 26 ES uninsulated screening and active build-up compensation Not shown: Rod probes DC 11, 16 EN and ES with ground tube; not for probes with active build-up compensation 2

Dimensions DC 11/16/21/26 EN For all probes on this page: Those on the left have threads 1½ - 11½ and those on the right threads 1½ A; see Page 6 for other process connections and housing dimensions =Length of active probe rod or probe rope =Length of partial insulation minimum: 75 mm, maximum: length minus 50 mm Left: DC 11 EN, fully insulated rod probe 75 4000 ø12 75 Partial insulation 4000 Right: DC 16 EN, partially insulated rod probe 75 75 ~10 ~10 75 Left: DC 11 EN, fully insulated rod probe with ground tube Right: DC 16 EN, partially insulated rod probe with ground tube Spacers all 0 mm, of PFA ø8 round tube Spacer ø38 4000 ø max. 43 ø max. 43 ø8 ø38 Partial insulation 4000 75 ~150 ~150 Active part of probe ~500 22000 ø4 ø2.5 Active part of probe ~500 22000 Left: DC 21 EN, fully insulated rope probe ø22 ø18 Right: DC 26 EN, partially insulated rope probe ø5 5 120 ø5 5 Tensioning weight always with anchor hole 3

Dimensions DC 11/16/21/26 ES Probe with screening against condensation and material build-up at the process connection (inactive section) For probes with threaded boss on this page: Those on the left with thread 1½ - 11½ and on the right with thread 1½ A; see Page 6 for other process connections =Length of active probe rod or probe rope =Length of partial insulation min.: 75 mm, max.: length minus 50 mm ø22 Active probe rod 4000 Above left: DC 11 ES, fully insulated rod probe with fully insulated screening and plastic coated flange ø12 42 ~10 ø8 ø38 ø max. 43 ø max. 43 Partial insulation Above, centre and right: rod probes with uninsulated screening,with partially insulated rod with full insulation also available: 4000 round tube Spacer DC 11 ES, fully insulated DC 16 ES, partially insulated Partial insulation ø max. 43 42 With ground tube DC 11 ES, fully insulated DC 16 ES, partially insulated 4000 Left: DC 21 ES, fully insulated rope probe with fully insulated screening and plastic coated flange 42 Right: DC 26 ES, partially insulated rope probe with uninsulated screening, uninsulated rope and uninsulated tensioning weight (as shown) With fully insulated active section this probe is designated DC 21 ES ø22 ~ ø max. 43 ~150 The screening (protection against condensation) is available in three standard lengths: = 150 mm = 0 mm = 500 mm ø4 ø2.5 Active part of probe ~500 22000 ø22 ø18 Active part of probe ~500 22000 Other lengths on request min. mm max. 4000 mm (uninsulated) max. 2000 mm (fully insulated) ø5 5 120 ø5 5 4

Dimensions DC 11/16/21/26 ES Continued Dimensions Probes with active build-up compensation (active guard) (for limit detection, length always 150 mm) Partially insulated probes shown but fully insulated probes also available where the active part of build-up compensation is always uninsulated. Not available with ground tube. Threaded versions: 1½ A 1½ - 11½ 150 75 ø max. 43 150 42 Left: rod probe DC 11 ES (fully insulated) or DC 16 ES (partially insulated) Right: active build-up compensation combined with screening Partial insulation ø12 min. 50 4000 Partial insulation ø12 min. 50 4000 Left: rope probe DC 21 ES (fully insulated) or DC 26 ES (partially insulated) Right: Active build-up compensation combined with screening The screening (protection against condensation) is available in three standard lengths: = 150 mm = 0 mm = 500 mm Other lengths on request min. mm max. 4000 mm ø5 ø2.5 ø18 ~150 5 150 75 Active part of probe ~500 22000 L 3 ø5 ø2.5 ø18 5 L 3 ø max.43 ~150 42 150 Active part of probe ~500 22000 5

60 Additional Process Connections and Accessories Flange Triclamp 2" Sanitary coupling DN 50 Other process connections: Flange Triclamp 2" Sanitary coupling DN 50 h* h* h* *h = mm for probes -DC EN -DC ES with fully insulated screening (protection against condensation) -DC ES with active build-up compensation *h = 47 mm for probes -DC ES with uninsulated screening (protection against condensation) -DC ES with uninsulated screening and active build-up compensation A B C Additional equipment: 20 A Temperature spacer for probes - DC EN - DC ES with fully insulated screening (protection against condensation) - DC ES with active build-up compensation 135 110 81 77 B Temperature spacer for probes - DC ES with uninsulated screening (protection against condensation) - DC ES with uninsulated screening and active build-up compensation D E F C Corrosion-resistant steel tag D as-tight gland for probes - DC EN - DC ES with active build-up compensation E as-tight gland for probes - DC ES with uninsulated screening (protection against condensation) - DC ES with uninsulated screening and active build-up compensation 170 145 115 112 205 180 F as-tight gland for probes - DC ES with fully insulated screening (protection against condensation) Housing Dimensions for EC... Z for FEC Housings in aluminium (Type T3) with separate connection compartment; - RFI filter with small electronic inserts EC 17 Z, EC 37 Z, EC 47 Z and FEC 12 (EEx ia), - safety barriers with FEC 12 (EEx d), - terminal connection module for FEC 22 With low cover for small electronic inserts EC...Z, with raised cover for electronic inserts FEC 12, FEC 14, FEC 22 with two cable entries, one sealed with a blind plug 91 ~130 max. 81.5 ø104 ~160 6

Technical Data eneral Information Manufacturer Instrument family Instrument types Function Endress+Hauser mbh+co. D-79689 Maulburg Multicap DC 11, 16, 21, 26 EN / ES Probes for capacitive level measurement and limit detection Operating Data Operating pressure Operating temperature Testing pressure to bar, depending on material see below to 200, depending on material see below to 150 bar / temperature 20 by repetitive test as requested Permitted operating pressures p e and temperatures The graph A do not apply to: - DC 21 EN / DC 21 ES, - DC 26 EN / DC 26 ES, - probes with active build-up compensation, - probes with fully insulated screening. The graph B applys to: - DC 21 EN / DC 21 ES, - DC 26 EN / DC 26 ES, - probes with active build-up compensation, - probes with fully insulated screening. A p e bar 80 60 40 20 20 bar to 1 bar p e bar 50 40 30 20 10 2 bar to 1 bar 50 0 50 150 200 50 0 50 150 200 C PTFE or PFA p e bar 20 10 2 bar to 1 bar 80 60 40 20 0 20 40 60 PE B PTFE, PFA or FEP A 80 T U EC FEC B 80 T U EC FEC Mounting of the electronic insert as a function of operating temperature and ambient temperature T U : A Probe without temperature spacer B Probe with temperature spacer or gas-tight gland C Electronic insert in separate housing D Probe with temperature spacer or gas-tight gland and electronic insert in separate housing The graphs A and B apply to all electronic inserts. The graphs C and D apply to the small electronic inserts EC 17 Z, EC 37 Z, EC 47 Z T U EC 0 0 80 40 0 40 80 120 160 200 80 40 0 40 80 120 160 200 40 40 C 40 120 80 40 Separate housing 0 0 80 40 0 40 80 120 160 200 80 40 0 40 80 120 160 200 40 40 D 40 160 120 80 40 T U Separate housing EC 7

Other Operating Data Lateral load on the probe rod Strain on the probe rope see below 200 N at 20, static Without ground tube With fully insulated screening max. 30 Nm max. Nm With active build-up compensation With ground tube With screening max. 45 Nm With screening and ground tube max. 300 Nm max. 60 Nm max. 300 Nm With screening and active build-up compensation max. 70 Nm max. 200 N Permissible lateral load on the probes Probe lengths Total length of a rod probe min. mm, max. 6000 mm, see dimensions Total length of a rope probe min. 500 mm, max. 26000 mm, see dimensions Capacitance values of the probe Basic capacitance approx. 30 pf Temperature spacer Air-tight entry Active build-up compensation approx. 20 pf approx. 20 pf approx. 10 pf Additional capacitances Probe 0 mm from a conductive vessel wall insulated probe rod in air approx. 1.3 pf/ mm, in water approx. 38 pf/ mm uninsulated probe rod in air approx. 1.3 pf/ mm insulated probe rope in air approx. 1.0 pf/ mm, in water approx. 20 pf/ mm uninsulated probe rope in air approx. 1.0 pf/ mm insulated tensioning weight in air approx. 2 pf in water approx. 60 pf uninsulated tensioning weight in air approx. 2 pf Rod probe with ground tube Uninsulated screening Fully insulated screening insulated probe rod uninsulated probe rod approx. 3 pf/ mm approx. 6 pf/ mm in air approx. 5.5 pf/ mm, in water approx. 35 pf/ mm in air approx. 5.0 pf/ mm Probe lengths for continuous measurement in conducting liquids EC with C max. = 2000 pf (EC 47 Z, FEC 12) Rope probe up to 8000 mm (up to 26000 mm in non-conducting liquids) rod probe up to 6000 mm EC with C max. = 4000 pf (EC 37 Z) Rope probe up to 20000 mm (up to 26000 mm in non-conducting liquids) rod probe up to 6000 mm 8

Other Operating Data Accuracy Length tolerances up to 1 m: + 0 mm, -5 mm rod probe, -10 mm rope probe up to 3 m: + 0 mm, -10 mm rod probe, -20 mm rope probe up to 6 m: + 0 mm, -20 mm rod probe, -30 mm rope probe up to 26 m: + 0 mm, -40 mm rope probe The following specifications only apply to the capacitance of insulated probes when used in conductive liquids. The deviation is insignificant for applications in non-conductive materials. Linearity error in water < 1 % at 1m length Temperature dependence of < 0,1 % per K the probe rod Pressure dependence of the approx. 0,2 % per bar probe rod Temperature dependence of < 0.1 % per K the probe rope Pressure dependence of the < 0.1 % per bar probe rope Process connections Parallel thread DIN ISO 228/I, with sealing ring 48x55 1½ A Tapered thread ANSI B 1.20.1 1½ - 11½ DIN flanges without DIN 27, Form B raised face DIN flanges with tongue DIN 12, Form F DIN flanges with groove DIN 12, Form N ANSI flanges ANSI B 16.5 Sanitary coupling DIN 11 851 Triclamp coupling ISO 2852 Materials Aluminium housing (Type T3) Seal for housing cover Sealing ring for process connection 1½ A Temperature spacer D-AI Si 10 Mg, DIN 17, plastic coated (blue / grey) O-ring in EPDM (elastomer) Elastomer-fibre, asbestos-free, resistant to oils, solvents, steam, weak acids and alkalis; up to 300, and bar Stainless steel 1.4301 or similar as-tight gland Stainless steel 1.4301 Further material specifications see Product Structure on Page 10...11 9

Product Structure DC 11 EN- DC 16 EN- DC 21 EN- MULTICAP DC 11 EN Fully insulated rod probe for standard applications MULTICAP DC 16 EN Partially insulated rod probe for standard applications MULTICAP DC 21 EN Fully insulated rope probe for standard applications Basic weight including 1½ A process connection and housing, for rope probes with tensioning weight 3,0 kg 3,0 kg 3,3 kg DC 26 EN- MULTICAP DC 26 EN Partially insulated rope probe for standard applications 3,2 kg DC 11 ES- MULTICAP DC 11 ES Fully insulated rod probe with protection features 3,0 kg DC 16 ES- MULTICAP DC 16 ES Partially insulated rod probe with protection features 3,0 kg DC 21 ES- MULTICAP DC 21 ES Fully insulated rope probe with protection features 3,3 kg DC 26 ES- MULTICAP DC 26 ES Partially insulated rope probe with protection features 3,2 kg Certificate A For non-hazardous areas B ATEX II 1/2, EEx ia IIC T6 D For non-hazardous areas, Overspill protection to WH E ATEX II 2, EEx d [ia] IIC T6 F ATEX II 1/2, EEx ia IIC T6, Overspill protection to WH H ATEX II 3, EEx na II T6 Y Special version 1 ATEX II 2, EEx d [ia] IIB T6 2 ATEX II 1/2, EEx ia IIB T6, Overspill protection to WH 3 ATEX II 1/2, EEx ia IIB T6 4 ATEX II 2, EEx d [ia] IIC T6* 5 ATEX II 1/2, EEx ia IIC T6*, Overspill protection to WH 6 ATEX II 1/2, EEx ia IIC T6* 7 ATEX II 3, EEx na II T6* * Note: Avoid electrostatic charge! Build-up protection DC 11, 16, 21, 26 EN A Build-up protection not selected DC 11, 16, 21, 26 ES B 150 mm active guard, 316Ti 0,5 kg C 150 mm screening, 316Ti 0,3 kg D 0 mm screening, 316Ti 0,5 kg E 500 mm screening, 316Ti 1,0 kg F...mm (75 mm...4000 mm), screening, 316Ti 2 kg/m 150 mm screening and 150 mm active guard, 316Ti 0,8 kg H 0 mm screening and 150 mm active guard, 316Ti 1,0 kg K 500 mm screening and 150 mm, active guard, 316Ti 1,5 kg L...mm (75 mm...4000 mm), screening and 150 mm active guard, 316Ti 2 kg/m + 0,5 kg 1 150 mm active guard, Alloy C 0,5 kg 3...mm (75 mm...4000 mm), screening, Alloy C 2 kg/m 5...mm (75 mm...4000 mm), screening and 150 mm active guard, Alloy C 2 kg/m + 0,5 kg 7...mm (75 mm...4000 mm), screening, fully insulated 1 kg/m Y Special version Probe insulation DC 11, 21 EN/ES 1 Fully insulated probe DC 16 EN/ES A...mm (20 mm...4000 mm),, PTFE insulated 0,1 kg/m B...mm (20 mm...4000 mm),, PFA insulated 0,1 kg/m C...mm (20 mm...4000 mm),, PE insulated 0,1 kg/m DC 26 EN/ES D Rope type: 2.5mm diameter Y Special version Active length, Material DC 11 EN/ES A...mm ( 50 mm...22000 mm), 316Ti+PTFE 1 kg/m B...mm ( 50 mm...22000 mm), steel+pe 1 kg/m C...mm ( 50 mm...22000 mm), steel+ptfe 1 kg/m D...mm ( 50 mm...22000 mm), 316Ti+PFA 1 kg/m E...mm ( mm...22000 mm), Alloy C+PTFE 1 kg/m F...mm ( mm...22000 mm), Alloy C+PFA 1 kg/m...mm ( mm...22000 mm), 316Ti+PTFE with ground tube 3 kg/m H...mm ( mm...22000 mm), 316Ti+PFA with ground tube 3 kg/m K...mm ( mm...22000 mm), steel+pe with ground tube 3 kg/m L...mm ( mm...22000 mm), Alloy C+PTFE with ground tube 3 kg/m M...mm ( mm...22000 mm), Alloy C+PFA with ground tube 3 kg/m Continued Page 11 DC.. E. - Product designation (first part) 10

Product Structure (Continued) Active length, Material (Continued) additional weights DC 16 EN/ES N...mm ( mm...22000 mm), Rod, 316Ti 0,9 kg/m P...mm ( mm...22000 mm), Rod, steel 0,9 kg/m R...mm ( mm...22000 mm), Rod, Alloy C 0,9 kg/m S...mm ( mm...22000 mm), 316Ti with ground tube 2,9 kg/m T...mm ( mm...22000 mm), steel with ground tube 2,9 kg/m U...mm ( mm...22000 mm), Alloy C with ground tube 2,9 kg/m DC 21 EN/ES 1...mm ( mm...22000 mm), Rope, 316, PE insulated tensioning weight with anchor hole 0,04 kg/m 2...mm ( mm...22000 mm), Rope, 316, FEP insulated tensioning weight with anchor hole 0,04 kg/m 3...mm ( mm...22000 mm), Rope, 316, PFA insulated tensioning weight with anchor hole 0,04 kg/m DC 26 EN/ES 4...mm ( mm...22000 mm), Rope, 316 tensioning weight with anchor hole 0,03 kg/m 5...mm ( mm...22000 mm), Rope, Alloy C tensioning weight with anchor hole 0,03 kg/m 9 Special version Process connection, Material E DN 50 PN 40, DIN 11851, 304 Hygienic connection F DN 40-51 (2"), ISO 2852, 304 Tri-Clamp connection 1½ A, Thread ISO 228, steel H 1½ A, Thread ISO 228, 316Ti K 1½ A, Thread ISO 228, Alloy C M 1½, Thread ANSI, steel N 1½, Thread ANSI, 316Ti P 1½, Thread ANSI, Alloy C Y Special version 5 Flanged process connection 0,5 kg 0,5 kg Flange type, Material AE2 2" 150 lbs, RF, ANSI B16.5, 316Ti 1,6 kg AE3 2" 150 lbs, RF, ANSI B16.5, PTFE >316Ti 1,6 kg A2 2" 300 lbs, RF, ANSI B16.5, 316Ti 3,0 kg A 3" 150 lbs, RF, ANSI B16.5, 316Ti 3,2 kg A 3" 150 lbs, RF, ANSI B16.5, PTFE >316Ti 3,2 kg AN2 3" 300 lbs, RF, ANSI B16.5, 316Ti 5,6 kg AP2 4" 150 lbs, RF, ANSI B16.5, 316Ti 5,4 kg AP3 4" 150 lbs, RF, ANSI B16.5, PTFE >316Ti 5,4 kg AR2 4" 300 lbs, RF, ANSI B16.5, 316Ti 7,3 kg AV2 6" 150 lbs, RF, ANSI B16.5, 316Ti A12 6" 150 lbs, RF, ANSI B16.5, 316Ti B1 DN 50 PN /40 B, DIN 27, steel 3,0 kg B2 DN 50 PN /40 B, DIN 27, 316Ti 3,0 kg B3 DN 50 PN /40, DIN 27, PTFE >316Ti 3,0 kg BM3 DN 80 PN 10/16, DIN 27, PTFE >316Ti 4,5 kg BQ3 DN PN 10/16, DIN 27, PTFE >316Ti 5,4 kg C2 DN 50 PN /40 C, DIN 27, 316Ti 3,0 kg CM2 DN 80 PN 10/16 C, DIN 27, 316Ti 4,5 kg CQ2 DN PN 10/16 C, DIN 27, 316Ti 5,4 kg Nur DC 11, 16 EN/ES, DC 21 EN KE2 10K 50A, RF, JIS B2210, 316Ti KE3 10K 50A, RF, JIS B2210, PTFE >316Ti KF1 20K 50A, RF, JIS B2210, steel 2,6 kg KF2 20K 50A, RF, JIS B2210, 316 Ti 2,6 kg Nur DC 11, 16 EN/ES, DC 21 EN K 10K 80A, RF, JIS B2210, 316Ti K 10K 80A, JIS B2210, PTFE >316Ti KP2 10K A, RF, JIS B2210, 316Ti KP3 10K A, JIS B2210, PTFE >316Ti YYY 1BB Special version without process flange connection Electronic insert E with EC 17 Z, 2-wire PFM 0,2 kg with EC 37 Z, 2-wire PFM, 33 khz 0,2 kg H with EC 47 Z, 2-wire PFM, 1 MHz 0,2 kg K with FEC 12, 2-wire 4 20 ma HART 0,3 kg* +0,3 kg M with FEC 22, 90 3 V AC, DPDT relay 0,3 kg* +0,3 kg N with FEC 22, 10 55 V DC, 3-wire PNP 0,3 kg* +0,3 kg P with FEC 14, PROFIBUS PA V with FEC 14, local operation FHB 20 and PROFIBUS PA Y Special version Housing Aluminium, T3 Housing, HNA24x1,5, IP66 M Aluminium, T3 Housing, gland M20x1,5, IP66 P Aluminium, T3 Housing, PA-plug M12, IP66 S Aluminium, T3 Housing, Nema 4x, ¾ T Aluminium, T3 Housing, entry ½ A, IP66 Y Special version Please don t forget: Length of mm Basic type Certificate Build-up protection Probe insulation Option 1 Basic version 3 with temperature spacer 0,5 kg 5 with gas-tight probe seal 0,5 kg 9 Special version Partial insulation mm * Addtional weight for raised cover Active probe length mm DC.. E. - Complete product designation for DC..EN,DC..ES 11

Accessories Slip-on sheet for partially insulated probes for increasing the switching safety for limit detection see Technical Information Probe accessories Rope shortening kit for fully insulated probes Rope shortening kit for partially insulated probes Supplementary Documentation Technical Information Probe accessories Technical Information TI 229F/00/en Electronic insert FEC 12 Technical Information TI 0F/00/en Electronic insert FEC 14 Technical Information TI 376F/00/en Electronic insert FEC 22 Technical Information TI 1F/00/en Electronic insert EC 17 Z Technical Information TI 268F/00/en Electronic insert EC 37 Z, EC 47 Z Technical Information TI 271F/00/en Transmitters for limit detection and continuous level measurement on request Certificates See product structure on page 10 Endress+Hauser mbh+co. K Instruments International P.O. Box 2222 D-79574 Weil am Rhein ermany Tel. (0 76 21) 9 75-02 Fax (0 76 21) 9 75-3 45 http://www.endress.com info@ii.endress.com 05.02/PT1 Endress +Hauser The Power of Know How TI 242F/00/en/06.03 SL/CV8