NUMERICAL INVESTIGATION OF FLUID FLOW AND HEAT TRANSFER CHARACTERISTICS ON THE AERODYNAMICS OF VENTILATED DISC BRAKE ROTOR USING CFD

Similar documents
INVESTIGATION OF HEAT TRANSFER CHARACTERISTICS OF CIRCULAR AND DIAMOND PILLARED VANE DISC BRAKE ROTOR USING CFD

Analysis of Air Flow and Heat Transfer in Ventilated Disc Brake Rotor with Diamond Pillars

Investigation for Flow of Cooling Air through the Ventilated Disc Brake Rotor using CFD

CFD Analysis and Comparison of Fluid Flow Through A Single Hole And Multi Hole Orifice Plate

Chapter 7: Thermal Study of Transmission Gearbox

THERMAL MANAGEMENT OF AIRCRAFT BRAKING SYSTEM

ABSTRACT I. INTRODUCTION III. GEOMETRIC MODELING II. LITERATURE REVIW

NUMERICAL INVESTIGATION OF PISTON COOLING USING SINGLE CIRCULAR OIL JET IMPINGEMENT

Scroll Compressor Oil Pump Analysis

Effect of Stator Shape on the Performance of Torque Converter

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

SOLAR FLAT PLATE COLLECTOR HEAT TRANSFER ANALYSIS IN THE RAISER WITH HELICAL FINS Mohammed Mohsin Shkhair* 1, Dr.

Numerical study of fluid flow and effect of inlet pipe angle In catalytic converter using CFD

EFFECT OF SURFACE ROUGHNESS ON PERFORMANCE OF WIND TURBINE

THERMAL STRESS ANALYSIS OF HEAVY TRUCK BRAKE DISC ROTOR

CFD ANALYSIS OF PRESSURE DROP CHARACTERISTICS OF BUTTERFLY AND DUAL PLATE CHECK VALVE

Numerical Study on the Flow Characteristics of a Solenoid Valve for Industrial Applications

Design of a Custom Vortex generator Optimization of Vehicle Drag and Lift Characteristics

Effect of concave plug shape of a control valve on the fluid flow characteristics using computational fluid dynamics

NUMERICAL ANALYSIS OF HELICALLY COILED HEAT EXCHANGER USING CFD TECHNIQUE

Design and Performance Analysis of Louvered Fin Automotive Radiator using CAE Tools

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

CHAPTER 5 PARAMETRIC STUDIES AND SQUEAL REDUCTION METHODS

Redesign of exhaust protection cover for high air flow levelling valve

FLOW AND HEAT TRANSFER ENHANCEMENT AROUND STAGGERED TUBES USING RECTANGULAR VORTEX GENERATORS

ANALYSIS OF BLADES OF AXIAL FLOW FAN USING ANSYS. Mahajan Vandana N.,* Shekhawat Sanjay P.

Turbostroje 2015 Návrh spojení vysokotlaké a nízkotlaké turbíny. Turbomachinery 2015, Design of HP and LP turbine connection

APPLICATION OF STAR-CCM+ TO TURBOCHARGER MODELING AT BORGWARNER TURBO SYSTEMS

Study on Flow Fields in Variable Area Nozzles for Radial Turbines

CONJUGATE HEAT TRANSFER ANALYSIS OF HELICAL COIL HEAT EXCHANGE USING CFD

Thermal Analysis of Shell and Tube Heat Exchanger Using Different Fin Cross Section

CFD ANALYSIS ON LOUVERED FIN

Enhanced Heat Transfer Surface Development for Exterior Tube Surfaces

Structural Analysis of Pick-Up Truck Chassis using Fem

Computational Fluid Dynamics in Torque Converters: Validation and Application

Muthoot Institute of Technology and Science, Varikoli, Kochi.

Optimisation of Double Pipe Helical Tube Heat Exchanger and its Comparison with Straight Double Tube Heat Exchanger

CFD ANALYSIS OF FLUID FLOW AND HEAT TRANSFER IN A SINGLE TUBE-FIN ARRANGEMENT OF AN AUTOMOTIVE RADIATOR

EFFECT OF SPOILER DESIGN ON HATCHBACK CAR

EXPERIMENTAL INVESTIGATIONS OF DOUBLE PIPE HEAT EXCHANGER WITH TRIANGULAR BAFFLES

ISSN (Online)

Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4 Stroke Engine

Comparative Numerical Analysis of Straight and Conical Coil Heat Exchanger

CFD Analysis for Designing Fluid Passages of High Pressure Reciprocating Pump

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 07, 2016 ISSN (online):

Prediction of Thermal Deflection at Spindle Nose-tool Holder Interface in HSM

Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

International Journal of Scientific & Engineering Research, Volume 7, Issue 3, March ISSN DESIGN AND ANALYSIS OF A SHOCK ABSORBER

Use of Flow Network Modeling for the Design of an Intricate Cooling Manifold

Back pressure analysis of an engine muffler using cfd and experimental validation

EFFECTS OF PISTON SPEED, COMPRESSION RATIO, AND CYLINDER GEOMETRY ON SYSTEM PERFORMANCE OF A LIQUID PISTON

Heat Transfer in Rectangular Duct with Inserts of Triangular Duct Plate Fin Array

Corresponding Author, Dept. of Mechanical & Automotive Engineering, Kongju National University, South Korea

THE EFFECT OF BLADE LEAN ON AN AXIAL TURBINE STATOR FLOW HAVING VARIOUS HUB TIP RATIOS. Dr. Edward M Bennett

COMPUTATIONAL FLOW MODEL OF WESTFALL'S 2900 MIXER TO BE USED BY CNRL FOR BITUMEN VISCOSITY CONTROL Report R0. By Kimbal A.

Investigation of converging slot-hole geometry for film cooling of gas turbine blades

CFD Analysis of Oil Cooler Duct for Turboprop Aircraft Engine in Pusher Configuration

Manufacturing Elements affecting the Performance & Durability Characteristics of Catalytic Converter

Computational flow field analysis of a Vertical Axis Wind Turbine

THERMAL ANALYSIS OF PISTON BLOCK USING FINITE ELEMENT ANALYSIS

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

DESIGN OF THROTTLE BODY: A COMPARATIVE STUDY OF DIFFERENT SHAFT PROFILES USING CFD ANALYSIS

Performance Calculation of Vehicle Radiator Group using CFD

COMPARATIVE STUDY OF MODAL ANALYSIS ON FLYWHEEL FOR AUTOMOTIVES

51. Heat transfer characteristic analysis of negative pressure type EGR valve based on CFD

Thermal Analysis of Helical and Spiral Gear Train

in ultra-low NOx lean combustion grid plate

Design and Test of Transonic Compressor Rotor with Tandem Cascade

Analysis of a turbine rim seal cavity via 3D-CFD using conjugated heat transfer approach

Study of intake manifold for Universiti Malaysia Perlis automotive racing team formula student race car

International Journal of Advance Engineering and Research Development

Numerical Investigation of the Effect of Excess Air and Thermal Power Variation in a Liquid Fuelled Boiler

Modeling and Fluid Flow Analysis of Wavy Fin Based Automotive Radiator

(1) Keywords: CFD, helicopter fuselage, main rotor, disc actuator

Enhance the Performance of Heat Exchanger with Twisted Tape Insert: A Review

COLD PLATE SOFTWARE PROGRAM ANALYZES AIRCRAFT

Analysis of Disc Brake Rotor Coning

[Rao, 4(7): July, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Design of A New Non-Contact Screw Seal and Determination of Performance Characteristics

PREDICTION OF PISTON SLAP OF IC ENGINE USING FEA BY VARYING GAS PRESSURE

CFD on Cavitation around Marine Propellers with Energy-Saving Devices

Comparison of Velocity Vector Components in a Di Diesel Engine: Analysis through Cfd Simulation

COMPUTATIONAL ANALYSIS TO MAXIMIZE THE HEAT TRANSFER RATE OF DOUBLE TUBE HELICAL COIL HEAT EXCHANGER

Udvavisk. Engineering Analysis with CFD. 1st Floor (B), Tower II, Ramana Complex #322, Velachery Main Road Velachery, Chennai

Stress Analysis of Engine Camshaft and Choosing Best Manufacturing Material

Optimization of Design Based on Tip Radius and Tooth Width to Minimize the Stresses on the Spur Gear with FE Analysis.

A Study on Performance Enhancement of Heat Exchanger in Thermoelectric Generator using CFD

Department of Mechanical Engineering, D Y Patil College of Engineering, Akurdi, Pune , Savitribai Phule Pune University, India

Thermal Stress Analysis of Diesel Engine Piston

Comparison of Swirl, Turbulence Generating Devices in Compression ignition Engine

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF THE ACOUSTIC PERFORMANCE OF VARIOUS SIMPLE EXPANSION CHAMBER MUFFLERS

Abstract In this study the heat transfer characteristics inside a rectangular duct with circular, rectangular, drop

Influence of Cylinder Bore Volume on Pressure Pulsations in a Hermetic Reciprocating Compressor

Finite Element Analysis of Connecting Rod to Improve Its Properties

Sports Car Brake Cooling Simulation with CAD-Embedded CFD

Theoretical and Experimental Investigation of Compression Loads in Twin Screw Compressor

ADVANCES in NATURAL and APPLIED SCIENCES

Design and Optimization of Contra-Rotating Fans Oliver Velde #, Christian Friebe &, Marius Korfanty #

DESIGN AND ANALYSIS OF UNDERTRAY DIFFUSER FOR A FORMULA STYLE RACECAR

FEM Analysis of Combined Paired Effect on Piston & Connecting Rod using ANSYS

Transcription:

THERMAL SCIENCE: Year 2014, Vol. 18, No. 2, pp. 667-675 667 NUMERICAL INVESTIGATION OF FLUID FLOW AND HEAT TRANSFER CHARACTERISTICS ON THE AERODYNAMICS OF VENTILATED DISC BRAKE ROTOR USING CFD by Thundil Karuppa Raj RAJAGOPAL *, Ramsai RAMACHANDRAN, Mathew JAMES, and Soniya Chandrakant GATLEWAR School of Mechanical and Building Sciences, Vellore Institute of Technology, Vellore, Tamil Nadu, India Original scientific paper DOI: 10.2298/TSCI111219204R Ventilated brake discs are used in high speed vehicles. The brake disc is an important component in the braking system which is expected to withstand and dissipate the heat generated during the braking event. In the present work, an attempt is made to study the effect of vane-shape on the flow-field and heat transfer characteristics for different configurations of vanes and at different speeds numerically. Three types of rotor configurations circular pillared, modified taper radial and diamond pillar vanes were considered for the numerical analysis. A rotor segment of 20 was considered for the numerical analysis due to its rotational symmetry. The pre processing is carried out with the help of ICEM-computational fluid dynamics and analysis is carried out using ANSYS CFX 12.1. The three dimensional flow through the brake rotor vanes has been simulated by solving the appropriate governing equations viz. conservation of mass, momentum and energy using the commercial computational fluid dynamic stool, ANSYS CFX 12. The predicted results have been validated with the results available in the literature. Circular pillar rotor vanes are found to have more uniform pressure and velocity distribution which results in more uniform temperature drop around the vanes. The effect of number and diameter of vanes in the circular pillared rotor is studied and the geometry is optimized for better mass flow and heat dissipation characteristics. Key words: computational fluid dynamics, disc brake, rotational symmetry, turbulence, vane shape Introduction Braking system is one of the important safety components of a vehicle. Braking system is mainly used to decelerate vehicles from an initial speed to a given speed. Friction based braking systems are the common device to convert kinetic energy into thermal energy through friction between the brake pads and the rotor faces. The modernization of multi-lane facilities paves the way for high-speed driving of vehicles. The passenger and racing cars require high speed braking system which could not be met with drum braking systems. Excessive thermal loading can result in surface cracking, judder, and high wear of the rubbing surfaces. High temperatures can also lead to overheating of brake fluid, seals and other components. The stopping capability of brake increases by the rate at which heat is dissipated due to forced convection and the thermal capacity of the system. * Corresponding author; e-mail: thundil.rajagopal@vit.ac.in

Rajagopal, T. K., et al.: Numerical Investigation of Fluid Flow and Heat Transfer... 668 THERMAL SCIENCE: Year 2014, Vol. 18, No. 2, pp. 667-675 Limpert [1] investigated the temperature distribution of solid rotors using Duhamel's theorem. Newcomb and Spurr [2] revealed that the thermal properties vary linearly with temperature. Chi [3] has performed the thermal characteristics of brake discs using analytical approaches on the assumption of laminar flow and simplified geometry. The air flow through the passage of vane rotors is a complex turbulent flow. Thus, how to select better geometrical design variables and improve thermal performance of automotive brake rotors is a task that the vehicle designers are often confronted. This is because it is found that the thermal failure is not only due to high temperatures, but also due to high thermal stresses developed because of non-uniform cooling of rotor vanes. Thus it is difficult to determine the effects of geometries of rotors on thermal performance of disc brakes. David et al. [4] have carried out the analysis for both flow surrounding the brake disc and inside the radial rotor passages using a two-component particle image velocimetry (PIV) system. Most of the previous studies have measured the air flow velocity profile at the exit of the passage of disc brake rotor using pressure probes. In some cases, they have used hot wire anemometry (HWA) to examine the unsteady flow-field at rotor exit [5, 6]. Prediction of average heat transfer coefficient was in the past largely performed by using semi-empirical correlations [7] whereas recent attempts to predict it by computational fluid dynamics (CFD) simulations can be found in the literature [8]. Anders and Bergstrom [9] has performed numerical simulation and compared the results with experimental data. Manohar Reddy [10] has validated the flow field velocities of a simple radial vane with the experimental data measured using PIV and modified the vane shape for maximum heat transfer. Structural analysis of ventilated rotor brake discs using CAE, finite element analysis (FEA) was reported by Amol and Ravi [11]. In their study, they reported the procedure for prediction of thermo-mechanical performance like temperature distribution and heat transfer coefficient estimation. Other studies have shown that inlet and cross-drilled holes can have a beneficial effect on the rate of cooling [12]. In the present work, three types of disc brake rotors, circular pillar (CP) modified taper radial vane (MTRV) and diamond pillar (DP) are analyzed for the effect of vane-shape rotor on the flow-field and heat transfer characteristics for different configurations of vanes using commercial CFD tool. The predicted results are validated with the numerical results of circular pillared vane performed by Manohar Reddy [10].Pillared vanes posses the advantage of curved vane rotors and bi-directionality which are mainly developed for high performance applications. It is taken care that the inlet and the exit area of ventilated rotor discs remains almost the same for all the configurations considered. The rotational speed of the rotor is varied from 800 rpm to 1400 rpm which corresponds to approximately 90 to 120 km/h. Two rotor temperatures 700 K and 900 K are considered for analysis. This temperature was calculated based on the absorption of kinetic energy by rotor immediately after applying the brakes [13]. The flow field characteristics like pressure and velocity components are plotted at mid-plane from inlet to exit of the ventilated rotor brake discs. The average mass flow rate and heat dissipation characteristics are also obtained in the present study. The numerical analysis is performed to select better geometric variables viz. the number of vanes and the diameter of vanes in circular pillared configuration for better mass flow and heat dissipation characteristics. Computational modeling and simulation Figure 1 shows the overall dimensions of the disc brake rotor which was used for CFD analysis for all the configurations of ventilated rotor brake discs. The dimensions of circular pillar vanes are similar to the model in literature [10] and are shown in fig. 2. The 20 sector model is considered for numerical analysis for all configurations due to the rotational symmetry. The

THERMAL SCIENCE: Year 2014, Vol. 18, No. 2, pp. 667-675 669 Figure 1. Disc brake rotor Figure 2. 20 sector of circular pillar vane created in CATIA Figure 3. 20 sector of modified taper radial vane created in CATIA Figure 4. 20 sector of diamond pillar vane created in CATIA 20 sector of the modified taper radial vane and diamond pillar vane created in CATIA are shown in fig. 3 and fig. 4, respectively. Grid generation The 3-D model of the circular pillar vane is imported in parasolid format in ICEM-CFD for mesh generation. In order to capture both the thermal and velocity boundary layers the entire model is discretized using hexahedral mesh elements which are accurate and involve less computation effort for the solver. The generation of hexahedral elements is quite difficult due to the complexities of rotor vane shapes. Fine control on the hexahedral mesh near the wall surface allows us to capture the boundary layer gradient accurately. The entire geometry is divided into three fluid domains FLUID_STATOR, FLUID_ROTOR_OUTER, and FLUID_ROTOR_INNER. The discretised model is checked to have a minimum angle of 27 with minimum determinant of 0.65. The meshes are checked for free of errors like volume and surface orientation and minimum required quality in order to achieve better convergence and are exported to ANSYS CFX pre-processor. The fluid mesh around circular pillar, modified tapered radial vane and diamond pillar vanes are shown in figs. 5, 6, and 7, respectively. The study was initially carried out with 1, 67,000 nodes and 4, 95,000 nodes. It is found that the variation in the numerical results between 1, 67,000 nodes and 3, 84,000 nodes is quite significant whereas the variation is negligible between 3, 84,000 and 4, 95,000 nodes. Thus the numerical results are independent of grid after 3, 84,000 nodes for circular pillared vanes. Similar grid independence studies are carried out for all the configurations considered for the analysis. Governing equations The 3-D flow through rotor vanes was simulated by solving the appropriate governing equations viz. conservation of mass, momentum, and energy using ANSYS CFX 12.1 code. Turbulence is taken care by Shear Stress Transport (SST) k-w model of Figure 5. Hexahedral fluid mesh of circular pillar vane Figure 6. Hexahedral fluid mesh of modified taper radial vane Figure 7. Hexahedral fluid mesh of diamond pillar vane

Rajagopal, T. K., et al.: Numerical Investigation of Fluid Flow and Heat Transfer... 670 THERMAL SCIENCE: Year 2014, Vol. 18, No. 2, pp. 667-675 Figure 8. Fluid domain of CP vanes created in ANSYS CFX 12.1 pre-processor closure which has a blending function that supports Standard k-w near the wall and Standard k-w elsewhere. Boundary conditions The fluid region of the ventilated brake disc is divided into three regions namely FLUID_STATOR, FLUID_ ROTOR_OUTER, and FLUID_STATOR. The fluid domain of CP ventilated rotor disc with boundaries specified in ANSYS CFX 12.1 pre-processor are shown in fig. 8. The connectivity between these domains is established by creating necessary fluid interfaces in the solver. The advantage of creating these domains separately helps in grid refinement in the FLUID_ROTOR_INNER compared to FLUID_ROTOR_OUTER and to have better control on the number of mesh nodes generated. The flow physics through the ventilated brake disc is quite complex as it contains both rotating and stationary domains. These domains are properly interfaced by FROZEN_ROTOR interface available in the ANSYS CFX solver, for which hexahedral mesh is relatively better compared to tetrahedral elements. The solid domain of rotor vanes is not generated as the rotors are assumed to have isothermal temperatures in this study. The rotational periodic nature of the disc brake rotor has enabled the consideration of only a segment of it rather than complete rotor for the analysis. As each of the rotors investigated have 36 passages, a 20 segment of the rotor is modeled, large enough to avoid the effect of boundary layer. Periodic boundaries are applied to either side of the segment to represent the entire rotor. The rotors are treated as spinning in an infinite environment by a rotating frame of reference and the application of an open boundary condition to the extent of the domain. The stator domain was considered three times the rotor diameter. The flow is assumed to be steady and incompressible ideal gas. Ambient temperature and pressure are assumed as 298 K and 101325 Pa, respectively. Rotor walls are assumed at constant temperature of 700 K for 800, 1000, and 1200 rpm and 900 K for 1400 rpm with smooth surface. For the analysis, moving frame of reference is considered, and buoyancy and radiation effects are neglected. Validation The predicted mass flow rate results of circular pillar vanes are compared with the results of Manohar Reddy et al. [10]. The mass flow rate predicted for various speeds from 800 rpm to 1400 rpm in steps of 200 rpm are Table 1. Mass flow rate of circular pillared vanes Speed [rpm] Numerical mass flow rate [gs 1 ] Literature mass flow rate [5], [gs 1 ] Error [%] 800 0.7 0.72 2.8 1000 0.98 0.96 2.1 1200 1.18 1.23 4.1 1400 1.37 1.32 3.8 given in tab. 1. The experimentally validated numerical data obtained from literature of Manohar Reddy [10] are tabulated in tab. 1 along with numerical readings predicted with ANSYS CFX 12.1 by this study. A very good agreement between the numerical and ex-

THERMAL SCIENCE: Year 2014, Vol. 18, No. 2, pp. 667-675 671 perimentally validated numerical data is obtained. The maximum deviation in mass flow rate is less than 5% and the same is plotted as shown in fig. 9. Results and discussion Mass flow rate and heat dissipation of isothermal rotors Mass flow rate and heat dissipation are often the common factors while selecting the vane configuration. Table 2 shows the predicted mass flow rate and heat dissipation of CP, MTRV and DP at 1000 rpm. The mass flow rate in MTRV is around 200% more than CP. The mass flow rate in DP is around 60% more than CP. The improved mass flow rate in MTRV is attributed to less vane hindrances for the fluid flow compared to CP and DP. Though CP has lesser mass flow rate compared to MTRV, the heat dissipation in CP and MTRV are almost the same. The above is because that CP has larger surface area compared to MTRV. Heat dissipation in DP is around 25% more than CP and MTRV but the mass flow rate lies in between CP and MTRV. Figure 9. Mass flow rate of centre pillared vanes Table 2. Mass flow rate of vane configurations at 1000 rpm Vane configuration Mass flow rate at [gs 1 ] Heat dissipation [W] CP 0.98 238.5 MTRV 3.19 245.0 DP 1.59 301.7 Velocity comparison of isothermal rotors The uniform distribution of air mass flow around the rotor vanes is essential for uniform temperature drop around the vanes. The velocity and pressure contours are plotted in the mid-plane which comprises of rotating and stationary fluid domains. Figure 10 shows the velocity distribution on mid plane for CP, MTRV, and DP at a speed of 1000 rpm. In MTRV, the average velocity in the mid plane is higher but the distribution is non uniform. It was found that the velocity magnitude increases from zero near the hub to the maximum near the tip of the vanes for all the three types of ventilated brake discs. Figure 10. Velocity distribution on mid plane for CP, MTRV, and DP at 1000 rpm (for color image see journal web site)

Rajagopal, T. K., et al.: Numerical Investigation of Fluid Flow and Heat Transfer... 672 THERMAL SCIENCE: Year 2014, Vol. 18, No. 2, pp. 667-675 In MTRV, the velocity at the right side of the vane is relatively less compared to the velocity at the right hand side. This will lead to thermal failure not because of high temperature but due to high temperature gradients exists between the sides of the rotor vanes. The velocity distribution in CP is more uniform around the vanes. The velocity distribution in DP is uniform than MTRV. The velocity distribution of CP is more uniform than DP and MTRV. Even though the average velocity is higher in MTRV and DP, CP is more preferred since the velocity distribution is uniform. This will result in even cooling of vanes. As stated earlier in this work, it is well established that not only the high temperature that causes the failure but also the temperature gradient which would result in failure of the rotor vanes. Pressure comparison of isothermal rotors Figure 11 shows the pressure distribution on mid plane for CP, MTRV, and DP at speeds of 1000 rpm, respectively. The average pressure drop in CP is less compared to DP and MTRV. The pressure variation is almost uniform around the vanes for CP. The pressure variation is non uniform around MTRV and DP rotor vanes. This uniform pressure distribution of CP helps in uniform thermal cooling of rotor vanes and more uniform distribution of mass flow around the vanes of CP. Figure 11. Pressure distribution on mid plane for CP, MTRV, and DP at 1000 rpm (for color image see journal web site) Effect of number of pillars The uniform velocity and pressure distribution around the vanes makes CP the preferred configuration disc brake compared to MTRV and DP. Since the air mass flow rate is less around the pillars compared to MTRV and DP an extensive numerical study is carried out to enhance the mass flow rate by analyzing the effect of number of pillars on fluid flow characteristics. The basic circular pillared brake disc had a diameter of 8 mm and the number of pillars is 12. Two case studies were carried out by varying the diameter of circular pillar vanes from 8 mm to 6 mm and 5 mm, respectively. The number of pillars was increased to 17 and 22 pillars for therby keeping the overall rotor mass constant. The analysis were carried out for different speeds of 800 rpm, 1200 rpm, and 1400 rpm for all the configurations as mentioned below in tab. 3. The mass flow rate and heat dissipation for different pillar diameters at various speeds are tabulated in tab. 3. It is to be noted that the isothermal surface temperature of rotor vanes were specified as 700 K for 800 rpm and 1200 rpm where as the surface temperature of rotor vanes are specified as 900 K for 1400 rpm.

THERMAL SCIENCE: Year 2014, Vol. 18, No. 2, pp. 667-675 673 Table 3. Mass flow rate and heat dissipation comparison for different pillar diameters Pillar diameter [mm]/ number of pillars 8/12 6/17 5/22 Speed [rpm] Mass flow rate [gs 1 ] Heat dissipation [W] 800 0.72 203.7 1200 1.23 277.0 1400 1.32 469.0 800 1.01 210.6 1200 1.53 286.5 1400 1.78 484.2 800 0.97 224.4 1200 1.46 288.2 1400 1.71 488.6 The mass flow rate increases with increase in rotational speed of disc brake for all the configurations. It could be observed that the mass flow rate for 6 mm diameter pillar is higher than that of 8 mm and 5 mm diameter pillar configurations. The heat dissipation increases with decrease in pillar diameter. This is because the number of pillars increases as the diameter decreases and hence more surface area to volume exists for better heat dissipation. The heat dissipation for 5 mm diameter pillar is better than 8 mm diameter pillar configuration. The heat dissipation for 5 mm diameter pillar is better than 6 mm diameter pillar at lower speeds but tends to become negligible at higher speeds. Figure 12 shows the velocity on the mid plane at 1200 rpm. The velocity magnitude at the mid-plane has increased with decrease in pillar diameter. The velocity magnitude of 6 mm diameter pillar is higher than that of 5 mm diameter pillar as shown in fig. 12. Moreover the velocity distribution of 6 mm diameter pillar is more uniform compared to 5 mm diameter pillar and this accounts for more mass flow rate of the former compared to the later. Similar velocity contours were obtained for other speeds of 800 rpm and 1400 rpm also. Figure 13 shows the pressure distribution on the mid plane at 1200 rpm. The pressure distribution of 6 mm diameter pillar is more uniform that 5 mm diameter pillar as shown in fig. 13 for 1200 rpm speed of circular pillared vanes. It is found that the pressure drop between the rotor vanes is decreased as the number of circular pillar increases from 8 to 22. This is because of the less hindrances offered to Figure 12. Velocity distribution on mid plane for pillar 8, 6, and 5 mm at 1200 rpm (for color image see journal web site)

Rajagopal, T. K., et al.: Numerical Investigation of Fluid Flow and Heat Transfer... 674 THERMAL SCIENCE: Year 2014, Vol. 18, No. 2, pp. 667-675 Figure 13. Pressure distribution on mid plane for pillar 8, 6, and 5 mm at 1200 rpm (for color image see journal web site) the flow due to decrease in the diameter of the circular pillared vanes. Hence from the study, it could be concluded that the 6 mm diameter circular pillared vanes offers better heat dissipation characteristics with more uniform pressure and velocity distribution. Conclusions In this present work, heat transfer characteristics of circular pillar, modified taper radial vane and diamond pillar vanes are analyzed. The following conclusions are drawn. Mass flow rate is considerably higher in modified taper radial vane compared to circular pillar rotor vanes. Heat dissipation in diamond pillared vane is around 25% higher as that of circular pillar and modified taper radial vanes. Circular pillar rotor vanes have more uniform pressure and velocity distribution which results in more uniform temperature drop around the vanes. This will ensure uniform and even cooling of rotor vanes. It would avoid the thermal failure of rotor vanes due to large thermal gradients between the rotor vanes as expected for MTRV and DP vanes. Due to these advantages, circular pillared vanes are preferred than modified taper radial vanes and diamond pillar vanes. The diameter and number of pillars in circular pillar vanes are modified for better mass flow rate and heat dissipation characteristics. It is found that the velocity and pressure distribution is uniform even when the diameter is reduced to 6 mm from 8 mm and this trend becomes less uniform when it is decreased further to 5 mm diameter. The 6 mm diameter with 17 circular pillared vanes has around 20% better mass flow rate and around 4% better heat dissipation characteristics compared to 8 mm diameter and 12 circular vane rotor brake discs. Limitations The results presented in this paper are on the assumptions of uniform temperature on the rotor surface. A varying heat flux model if incorporated for the rotor surface would closely approximate to actual conditions. It is currently under study. References [1] Limpert, R., The Thermal Performance of Automotive Disc Brakes, Journal of SAE, 750873 (1975), 1, pp. 4-7

THERMAL SCIENCE: Year 2014, Vol. 18, No. 2, pp. 667-675 675 [2] Newcomb, T. P., Spurr, R. T., Braking of Road Vehicles, Chapman and Hall, London, 1967 [3] Chi, Z., Thermal Performance Analysis and Geometrical Optimization of Automotive Brake Rotors, M. Sc. thesis, University of Ontario Institute of Technology, Oshawa, Canada, 2008 [4] David,A., et al.,analysis of the Flow through a Vented Automotive Brake Rotor, Journal of Fluids Engineering, 125 (2003), 1, pp. 979-986 [5] Parish, D, MacManus, D. G., Aerodynamic Investigations of Ventilated Brake Discs, Journal of Automobile Engineering, 219 (2005), Part D, pp. 471-486 [6] Barigozzi, G., et al., Experimental Investigation of the Mean and Turbulent Flow Characteristics at the Exit of Automotive Vented Disc Brakes, Journal of SAE, 2593 (2002), 1, pp. 9-13 [7] Voller, G. P., et al., Analysis of Automotive Disc Brake Cooling Characteristics, Journal of Automobile Engineering, 217 (2003), Part D, pp. 657-666 [8] Stephens., A., et al., Aerodynamic Testing of a Vented Disc Brake, JournalofSAE, 0932 (2003), 1, pp. 6-8 [9] Jerhamre, A., Bergstrom, C., Numerical Study of Brake Disc Cooling Accounting for both Aerodynamic Drag Force and Cooling Efficiency, Journal of SAE, 0948 (2001), 1, pp. 3-5 [10] Manohar Reddy, S., et al., Flow and Heat Transfer Analysis of a Ventilated Disc Brake Rotor Using CFD, Journal of SAE, 0822 (2008), 1, pp. 1-12 [11] Amol, A., Ravi, R., FE Prediction of Thermal Performance and Stresses in a Disc Brake System, Journal of SAE, 2572 (2008), 1, pp. 5-8 [12] Manohar Reddy, S., Flow and Heat Transfer Analysis of a Ventilated Disc Brake Rotor Using CFD, M.Sc. thesis, Indian Institute of Technology, Madras, Chennai, India, 2007 [13] Sakamoto, H., Heat Convection and Design of Brake Discs, Journal of Rail and Rapid Transit, 218 (2004), Part F, pp. 203-212 Paper submitted: December 19, 2011 Paper revised: September 26, 2012 Paper accepted: October 25, 2012