Burners. Metallic free flame burners. EMB (E3004 rev /02/2010)

Similar documents
Free flame burners EMB (E3004 rev /02/2015)

Burners. Pilot Heads BTC & BTSA (E3121 rev /04/2018)

Burners. High velocity LOW NOx combustion air burners EMB-SIK-NxT (E3507 rev /11/2016)

Burners. Pilot Heads BTC & BTSA (E3121 rev /09/2010)

Orifice Flow Meters POP-S (E5720 rev /03/2013)

Burners. Self-recuperative burners high speed with flat flame REKO-SIK-SW (E3903 rev /06/2015)

Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012)

Burners. Self-recuperative burners high speed free flame REKO-SIK-FF (E3901FF rev /05/2009)

Radiant tube burners RT (E3900 rev /01/2018)

Burners. Ribbon linear flame burners AB & ABM (E3010 rev /11/2017)

Valves. Slow opening and rapid closing solenoid valves VM-L (E1111 rev /11/2012)

OIL REGULATORS RFG SERIES FEATURES APPLICATIONS DESCRIPTION INSTALLATION. Bulletin E5301 rev03 02/04/03. Body and valve seat: Shutter seat:

Valves. Double stage and modulant motorized butterfly valves MRBV & MRBV-CMAP (E1302 rev /04/2011)

Electronics. Permanent operation microprocessor burner control device ESA GENIO-S (E7021 rev /05/2015)

Electronics. Permanent operation microprocessor burner control device ESA GENIO-PRS (E7022 rev /05/2015)

Electronics. Permanent Operation Microprocessor Burner Control ESA ESTRO-PO (E7014PO rev /05/2013)

North American 4485 Tempest SE

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Specifications of STICKTITE and PILOTPAK Nozzles

KINEMAX. Medium velocity gas or oil burners

2.0 Burner Operating Parameters and Requirements

Specifications of STICKTITE and PILOTPAK Nozzles

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

LVDT/HC PILOT BURNER. External raw gas pilot burner

PREMIX TUNNEL BURNERS

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

VF VFH. elektrogas.com. Butterfly valves DN40 DN150 EE155-11/11

Eclipse RatioAir Burners

MULTIFIRE. High temperature dual fuel burner

all combustible gases and fuel oil, extra light gases up to 1 bar, fuel oil up to 40 bar Fuel Connection gases ½, fuel oil ¼

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

ATTENTION: Industrial machinery for professional use. These instructions are for qualified personnel USE AND MAINTENANCE MANUAL

North American 4575 HiRAM

VALUPAK. Packaged gas burners

1470 SERIES HOT AIR GAS BURNER

G72x Series Direct Spark Ignition Controls

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

Oil, gas and dual fuel burners. Burner series

1200 SERIES FTR HOT AIR BAFFLE BURNER

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Specifications of LVDT/HC-pilot burner. Materials of construction. Duct burners - LVDT/HC-pilot burner. combustion systems for industry

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

PNEUMATIC PUMP Series

available in battery up to 4 units for a total of 560 kw

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

Low emissions, high performance natural gas burners

NOx-Beta Ultra Low NOx Burners

Installation- and maintenance instruction ST120 S75/21

US - UP2/OIL 12V US - UP2/OIL 24V

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Mobile Diesel Heaters GRY-D / GRY-I Service Training Course

[Vacuum valves and solenoid valves] 4

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles

ONE STAGE GAS BURNERS RS/1 SERIES RS 28/ kw RS 34/1 MZ kw RS 38/ kw RS 44/1 MZ kw

VGD20... VGD40... Double Gas Valves. Siemens Building Technologies Landis & Staefa Division

VAL6 KBE5S. Service Manual

RS/M SERIES. Modulating Gas Burners FIRING RATES

VALIADIS S.A. HELLENIC MOTORS

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

North American Combustion Burners

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

ONE STAGE GAS BURNERS RDBS SERIES

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

FABER BURNER ROUTINE MAINTENANCE

Installation- and maintenance instruction BENTOFLEX ST 108 PL

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES

INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL MANUAL

Oil, Gas and Dual Fuel Burners

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Installation- and maintenance instruction BENTOFLEX ST120KAV

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

GAS BURNERS BLU 3000 PR BLU 4000 PR

Doing more for clean environment and energy saving

VALUPAK. Packaged gas burners

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

Installation- and maintenance instruction BENTOFLEX ST133K

Instructions. for Installation, Operation and Maintenance of ABO Butterfly Valves, Series 600 and 900

E Series CE Approved Intermittent Pilot Ignition Control

DB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Specifications of OPTIMA SLS Burners

TECHNICAL DATA LEAFLET GAS. RS/1 Series. One Stage Gas Burners. RS 34/1 MZ kw RS 44/1 MZ kw.

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT

G76x Direct Spark Ignition Controls

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

Electromagnetic flowmeters

DIAPHRAGM PUMPS: Instruction Manual

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE

North American Combustion Burners

Ignition Reliability in SGT-750 for Gas Blends at Arctic Conditions. Magnus Persson Combustion Expert / Distributed Generation / Sweden

G600 Series Replacement Intermittent Pilot Ignition Controls

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

EVS RP6020. Instruction Manual

Transcription:

Burners Metallic free flame burners EMB (E3004 rev. 06-11/02/2010)

GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff, respecting the norms present at the time and place of the installation. ¾ To avoid damage to people and things, it is essential to observe all the points indicated in this handbook. The reported indications do not exonerate the Client/User from observing general or specific laws concerning accidents and environmental safeguarding. ¾ The operator must wear proper DPI clothing (shoes, helmets...) and respect the general safety, prevention and precaution norms. ¾ To avoid the risks of burns or high voltage electrocution, the operator must avoid all contact with the burner and its control devices during the ignition phase and while it is running at high temperatures. ¾ All ordinary and extraordinary maintenance must be performed when the system is stopped. To dispose of the product, abide by the local legislations regarding it. GENERAL NOTES: ¾ In accordance to the internal policy of constant quality improvement, ESA-PYRONICS reserves the right to modify the technical characteristics of the present document at any time and without warning. ¾ It is possible to download technical sheets which have been updated to the latest revision from the www.esapyronics.com website. CERTIFICATIONS: ¾ To assure correct and safe use of the combustion plant, it is of extreme importance that the contents of this document be brought to the attention of and be meticulously observed by all personnel in charge of controlling and working the devices. ¾ The functioning of a combustion plant can be dangerous and cause injuries to persons or damage to equipment. Every burner must be provided with certified combustion safety and supervision devices. ¾ The burner must be installed correctly to prevent any type of accidental/undesired heat transmission from the flame to the operator or the equipment. EN746-2 The products manufactured by ESA-PYRONICS have been created in conformity to the UNI EN 746-2 Norms: Equipment for industrial thermal process - Part 2: Safety requirements for combustion and the movement and treatment of combustible elements. This norm is in harmony with the Machine Directive 98/37/CE. It is certified that the products in question respect all the requirements prescribed by the above mentioned Norms and Directives. These have been designed, produced, controlled and tested in accordance to the company s internal procedures for quality control, certified in conformity with the UNI EN ISO 9001 Norm by DNV Italia s.r.l. The products conform to the Russian market requirements according to the GOST and GOSGORTEKHNADZOR certification. ¾ The performances indicated in this technical document regarding the range of products are a result of experimental tests carried out at ESA-PYRONICS. The tests have been performed using ignition systems, flame detectors and supervisors developed by ESA-PYRO- NICS. The respect of the above mentioned functioning conditions cannot be guaranteed if equipment, which is not present in the ESA-PYRONICS catalogue, is used. Headquarters: Esa s.r.l. Via Enrico Fermi 40 24035 Curno (BG) - Italy Tel +39.035.6227411 Fax +39.035.6227499 esa@esacombustion.it CONTACTS / SERVICE: International Sales: Pyronics International s.a. Zoning Industriel, 4ème rue B-6040 Jumet - Belgium Tel +32.71.256970 Fax +32.71.256979 marketing@pyronics.be www.esapyronics.com www.esapyronics.com 2

The EMB are metallic gas burners are used for direct heating. These burners allow excess air, stoichiomentric and excess gas regulation. Depending on the size and use, this type of burner can be used for natural gas and LPG combustion (in the standard version) and other types of gaseous combustive agents with heating different properties (special versions on request). APPLICATIONS ¾Ceramic furnaces or fibre cover treatment furnaces. ¾Tunnel or chariot furnaces. ¾Dryers. ¾Textile and dry cleaning machines (Rameause). ¾Stretching furnaces. F3400I03 CHARACTERISTICS GENERAL: ¾Capacity: From 20 to 1.500 kw ¾Temperature limit: 1.000 C ¾Air and gas pressure to burner: 45mbar ¾Flow ratio: 8 : 1 ¾Flame speed: 50-60 m/s ¾Low CO2 content: <10PPM (@ 3% O 2 ) ¾Excess air: up to 400% MATERIAL COMPOSITION: ¾Mixer body: ¾Gas collector: ¾Flameproof tube: ¾Combustion head: ¾Fixing flange: Cast iron G25 Cast iron G25 AISI304 AISI310 Fe F3400I04 www.esapyronics.com 3

PARAMETER CAPACITY AND FLAME LENGTH The EMB burner ignition takes place through a high tension discharge obtained via an electrode and the detection is performed by another electrode. Both are included with the supply. The adoption of flame control systems is highly recommended in all plants operating at temperatures lower than 750 C (UNI EN746/2 Regulation). Model Capacity [kw] Flame length [mm] Flame tube outlet diameter [mm] Flame speed [m/s] Flame ignition and detection EMB-0 20 150 200 37 40 N.1 WAND electrode EMB-1 30 300 400 43 42 N.2 WAND electrodes EMB-2 80 500 700 64 51 N.2 WAND electrodes EMB-3 150 700 1000 94 44 N.2 EN electrodes EMB-4 300 1000 1250 122 52 N.2 EN electrodes EMB-5 400 1200 1500 122 69 N.2 EN electrodes EMB-6 600 1500 2000 160 56 N.2 EN electrodes EMB-7 900 1800 2400 187 67 N.2 EN electrodes EMB-8 1.500 2200 3000 211 88 N.2 EN electrodes The flame lengths and velocities are approximate, they refer to burners fed by natural gas that are placed in open air and function in stoichiometric ratio at nominal capacity. In special applications, mono-electrodes for the ignition and flame detection are used or else an electrode for flame ignition and a UV photocell for the flame detection is used. DESCRPTION The EMB metallic burners are "nozzle mix" type burners. The fuel and combustive agents are mixed at the combustion head to avoid dangerous flame flashbacks. Furthermore, the special shape of the combustion head allows regulation in stoichiometric ratio as well as in excess air. The EMB burners develop the maximum capacity in stoichiometric ratio with 45mbar of air pressure. This implies the use of low prevalence blowers which are also inexpensive; the setting is simplified due the special differential pressure plugs that allow the measurement of air and gas flow. www.esapyronics.com 4

BURNER PERFOMANCE The flame capacity, length and speed refer to a natural gas fed burner (8600 Kcal/Nm³) placed in a combustion chamber at zero pressure above sea level, functioning with 10% of excess air. ¾Chamber temperature 1000 C ¾NOx < 200 mg/nm 3 [O 2 = 3% ref.] ¾Room air temperature MAXIMUM CAPACITY Max capacity Free flame application Burner model EMB-0 EMB-1 EMB-2 EMB-3 EMB-4 EMB-5 EMB-6 EMB-7 EMB-8 Burner capacity (2% O 2 ) [kw] 20 30 80 150 300 400 600 900 1500 Combustion air flow [Nm 3 /h] 22 33 88 165 330 440 660 990 1650 Gas flow [Nm 3 /h] 2 3 8 15 30 40 60 90 150 Burner air inlet pressure [mbar] 45 Δp flange gas measurement [mbar] 10 MINIMUM CAPACITY Min capacity Free flame application Burner model EMB-0 EMB-1 EMB-2 EMB-3 EMB-4 EMB-5 EMB-6 EMB-7 EMB-8 Burner capacity(2% O 2 ) [kw] 2 3 8 15 30 40 60 90 150 Combustion air flow [Nm 3 /h] 2,2 3,3 8,8 16,5 33 44 66 99 165,5 Gas flow [Nm 3 /h] 0,2 0,3 0,8 1,5 3,0 4,0 6,0 9,0 15,0 Burner air inlet pressure [mbar] 0,5 Δp flange gas measurement [mbar] 0,1 www.esapyronics.com 5

NATURAL GAS CAPACITY TABLE AIR CAPACITY TABLE Burner feeding pressure [mbar] Differential pressure at orifice flow meter [mbar] Natural gas flow @ 20 C P.S.=0,6 [Nm 3 /h] G3004I01 Total air flow (burner + ejector) @ 30 C P.S.= 1 [Nm3/h] G3004I02 www.esapyronics.com 6

FLOW SCHEME -FREE FLAME METALLIC BURNER D3004I01 Pos. Description Included Not included 1 Main gas interception ball valve X 2 Balanced modulator X 3 Impulse line X 4 Servo-controlled air regulation butterfly valve X 5 Electric servo-control X 6 Single burner gas interception ball valve X 7 Main burner safety gas solenoid valve X 8 DP gas measurement calibrated flange X 9 Gas passage limiting device X 10 Manual air regulation butterfly valve X 11 DP inlet air pressure measurement calibrated orifice X 12 Free flame burner X 13 Ignition transformer X 14 Flame control X 15 Premix air regulation kit (only LPG versions) X www.esapyronics.com 7

FLOW SCHEME -FREE FLAME METALLIC BURNER D3004I02 Pos. Description Included Not included 1 Main gas interception ball valve X 2 Balanced modulator X 3 Impulse line X 4 Servo-controlled air regulation butterfly valve X 5 Electric servo-control X 6 Single burner gas interception ball valve X 7 Main burner safety gas solenoid valve X 8 DP gas measurement calibrated flange X 9 Gas passage limiting device X 10 Manual air regulation butterfly valve X 11 DP inlet air pressure measurement calibrated orifice X 12 Free flame burner X 13 Ignition transformer X 14 Flame control X 15 Premix air regulation kit (only LPG versions) X www.esapyronics.com 8

WARNINGS ¾ The EMB burner ignition must always be carried out at minimum power, modulating towards the maximum, facilitating the ignition and reducing the outlet overpressures. Thus it is opportune to use slow opening solenoid valves on the fuel line. ¾ The passing from minimum to maximum power and vice-versa, must be gradual and not instantaneous. In double stage regulations, the use of MRBV regulation valves (data sheet E1302) is suggested. ¾ For all low temperature applications (up to 750 C), the burner ignition and the fuel gas solenoid valve commands must be performed via a certified burner control device. ¾ To avoid possible damage to burners, make sure that the blower does not send them air that may be fouled by combustion products, oils, solvents or other. To avoid these phenomena from taking place, possibly install the blower or the suction duct outside the establishment and far from the exhaust pipes. ¾ Check the correct connection of the feeding lines after installation. Before switching the burner on, check that the combustive air and fuel gas pressure values are correct (Pag.05). ¾ The burner can only function within the indicated power range. Functioning at lower or higher powers could compromise the burner performance as well as its life span. In which case, the general warrantee conditions will automatically expire and ESA will not be held responsible for any damage to persons or things. ¾ If there is trouble with other devices during the burner start up phase, use the connector with anti disturbance filter for the high-tension (HT) cable connection of the ignition electrode. ¾ Avoid burner ignition close to each other so as not to heat the ignition command system devices (solenoid valves and transformers). Prewash time lapse + first safety time lapse + min. of 5 sec. = time lapse between one ignition and another. (however, do not attempt more than 2 ignitions during a 30sec. time lapse). ¾ Make sure the power supply is TURNED OFF when intervening on the burner and its devices. In case of burner malfunctioning, follow the indications in the 'Maintenance' chapter of the present manual or contact ESA-PYRONICS assistance. ¾ Any modification or repair done by third parties can compromise the application safety and automatically cause the general warrantee conditions to expire. www.esapyronics.com 9

INSTALLATION The EMB series burners are supplied with a special furnace wall fixing flange. The light obtained for the burner housing must leave open space around the burner. This space has then to be filled with ceramic-fibre. For the installation carefully follow the instructions below: 1 - Place the EMB burners far from heat sources and products such as: liquids, solvents or corrosive gases. 2 - Make sure that the housing dimensions and the distance between the centers of the feeding pipes correspond to what is specified in the "Overall dimensions" chapter. 3 - Assemble the burner on the furnace wall (pos. 01) interposing a ceramic fibre gasket between the attachment flange and the furnace wall (pos.02). During the burner insertion phase check that the insulation previously wrapped around the outside is not altered nor damaged. Once the spacer has been fixed onto the furnace, from the inside of the combustion chamber, seal any possible cracks that may be left between the wall and the spacer with ceramic fibre. 4 - Connect the combustion air and fuel gas inlet piping, interposing, if possible, dilation joints in AISI. D3004I03 5 - Connect electricity to the ignition electrode and to the uv-scan detector making sure not to pass the conductors near heat sources. 6 - Check that the burner body and all its metallic elements are earthed with appropriate conductors. 7 - The connecting cable from the ignition transformer to the electrode must be specific for high tension and not screened. It must not be more than 1 metre long; otherwise the ignition transformer must be positioned near the burner. The high tension cable must be placed far from the power cables and not in metallic ducts. Ideally it should be left in open air. 8 - For further information please consult the technical data sheet concerning the ignition transformers. 9 - Connect electricity to the ignition electrode and to the uv-scan detector making sure not to pass the conductors near heat sources. D3004I04 www.esapyronics.com 10

START-UP - SETTING The procedures indicated in the following chapter must be carried out by expert technicians. The non-observance of the instructions given can provoke dangerous conditions. 1 - Check that the combustion air pressure exiting the blower and the combustive fuel feeding pressure are both within the allowed range. 2 - Adjust the working pressure and the safety device pressure of the combustion plant, whether there is one per burner or one for the whole plant i.e. gas pressure reduction gear, block valve, relief valve, pressure switches etc. Simulate the intervention of all the safety devices including the intervention of the safety over temperature, checking that the fuel safety block devices act properly. 3 - Place the motorized air regulation valve in its maximum opening position and, via the gate valve, regulate the inlet air pressures to the burner, referring to the values indicated in the "burner performance" chapter for the maximum capacities (pag.05). 5 - Activate the burner control device and attempt the ignition until the burner switches on. While attempting to ignite the burner, act on the gas adjustment valve and, starting from the totally closed position, open it gradually until the burner ignites. 6 - Fully open the air regulation valve and adjust the maximum fuel capacity via the gas adjustment valve, checking the differential pressure created on the calibrated gas flange. 7 - Double check that, at minimum and maximum power, the burner inlet pressure corresponds to the values in the in the 'Parameter capacity" chapter. These values may be different depending on whether the burner is on or off. 8 - If necessary, with all burners turned onto the same power, analyse the combustion products in the chamber (where possible). 9 - Repeatedly attempt ignition at minimum burner power, with maximum amplitude, to check the ignition reliability and flame stability during the adjustment. 4 - Place the motorized air regulation valve in its minimum opening position and regulate its opening to obtain (in burner and ejector inlet) the relative minimum power pressure. PREMIX AIR FLOW SETTING WHERE SCHEDULED (LPG BURNERS) The premix line is supplied with the LPG burners. The setting must be carried out with burner off and in minimum flow conditions. The premix line must be fed by an inlet necessarily placed upstream the air flow regulation valve, whether it is in zone or interlocked by the main burner. 1. Place the burner in the minimum combustion air flow conditions. EMB-1: Gas body pressure = 2 mbar EMB-2: Gas body pressure = 2 mbar EMB-3: Gas body pressure = 2 mbar EMB-4: Gas body pressure = 2 mbar EMB-5: Gas body pressure = 2 mbar EMB-6: Δp = 6.5 mbar EMB-7: Δp = 2.5 mbar EMB-8: Δp = 5 mbar 2. Open the premix air tap. 3. Regulate the micrometric pin valve according to the following conditions: 4. Check, however, that at minimum power, the burner does not create black smoke on the combustion head and on the electrodes. In case this should occur, increase the premix air setting. www.esapyronics.com 11

GENERAL MAINTENANCE PLAN Operation Type Advised time Notes High tension electrode connection O annual check integrity of outer plastic and oxidi -zation of internal electrode terminal. Electrode ignition / detection O annual replace if the kantal terminal is worn. Flanged tube combustion head O annual Replacement of gas side gaskets (**) S biennale Burner setting S annual Premix air setting (where scheduled) S annual during furnace stop, check that the two elements do not show signs of oxidization caused by high temperature Check that the gaskets are free of air leaks and that there is no vulcanization in the rubber From the inside check that there are no cracks in the refractory material every time the furnace is stopped for maintenance From the inside check that there are no cracks in the refractory material every time the furnace is stopped for maintenance NOTES: Key: O=ordinary / E=extraordinary (*) it is suggested that the gaskets on the gas side are replaced after every disassembly of the gas feeding line. (**) use high temperature gaskets www.esapyronics.com 12

ORDINARY MAINTENANCE For correct dismantling and better maintenance of the EMB burner, meticulously follow the instructions below with the plant turned off. IGNITION AND FLAME DETECTION ELECTRODE REPLACEMENT 1 - Check that the burner control device is disconnected. 2 - Disconnect electrical supply to the electrodes (pos.01). 3 - Unscrew the connector (pos.02) at the base of the gas collector, removing the electrode (pos.03). 4 - Replace the faulty electrode (pos.03) paying attention to the correct repositioning of the new electrode. 5 - Reconnect the electrical supply (pos.01). 6 - Check the electrode's correct flame ignition/detection. D3400I05 www.esapyronics.com 13

EXTRAORDINARY MAINTENANCE For correct dismantling and better maintenance of the EMB burner, meticulously follow the instructions below with the plant turned off. BURNER-SHUTDOWN For correct dismantling and better maintenance of the EMB burners, meticulously follow the instructions with the plant turned off. In shutdown conditions of the burner refer to the burner control device indications and to the relative manual to identify the cause. The main cases are indicated here below: ¾Illegal flame detection: the shutdown is due to an illegal flame detection during the phases prior to ignition or after the turning off. The causes are within the detection system (broken or faulty sensor or presence of humidity), or in the gas draw from the solenoid safety valve, which allows the burner to remain turned on. ¾Failed ignition: shutdown is caused due to the fact that no flame has been created during the starting process. The causes can be found in the start-up system (spark absence, faulty electrodes or incorrect position), in the bad setting of the fuel and combustion flow or in the detection system (faulty sensor or interrupted cables). More precisely, in the first two cases the flame is not ignited, while in the last case the flame is created but the burner control device is unable to detect it. ¾Flame signal loss: shutdown due to the loss of flame signal during the normal functioning of the burner. The causes can be found in the combustion air flow adjustment (rapid flow variations, adjustment out of allowed range). They can also be found in the detection system (faulty, dirty or badly positioned sensors). www.esapyronics.com 14

EMB-0 OVERALL DIMENSIONS D3400I06 www.esapyronics.com 15

EMB-1-CH4 OVERALL DIMENSIONS D3400I07 www.esapyronics.com 16

EMB-1 LPG OVERALL DIMENSIONS D3400I08 www.esapyronics.com 17

EMB-2-CH4 OVERALL DIMENSIONS D3400I09 www.esapyronics.com 18

EMB-2 LPG OVERALL DIMENSIONS D3400I10 www.esapyronics.com 19

EMB-3-CH4 OVERALL DIMENSIONS D3400I11 www.esapyronics.com 20

EMB-3 LPG OVERALL DIMENSIONS D3400I12 www.esapyronics.com 21

EMB-4-CH4 OVERALL DIMENSIONS D3400I13 www.esapyronics.com 22

EMB-4 LPG OVERALL DIMENSIONS D3400I14 www.esapyronics.com 23

EMB-5-CH4 OVERALL DIMENSIONS D3400I15 www.esapyronics.com 24

EMB-5 LPG OVERALL DIMENSIONS D3400I16 www.esapyronics.com 25

EMB-6-CH4 OVERALL DIMENSIONS 186 121 Gas inlet Rp 2" X= Wall thickness Air inlet DN150 Gas inlet Ø 2" 100 Min. (a) 70 100 Min. (a) Gas orifice flowmeter (included) Assembly by customer R A Ø203 451 175 155 156 Ø168 NOTES: (a) by customer Nr.4 holes Ø14 on 235 D.B.C. D3400I17 www.esapyronics.com 26

EMB-6 LPG OVERALL DIMENSIONS 501± 5 92 120 48 120 122 186 Premix air Inlet Rp 1.1/2" 94 Gas inlet Rp 1.1/2" 100 Min. (a) 72 100 Min. (a) Gas inlet Ø 1.1/2" Gas orifice flowmeter (included) Assembly by customer 624 Air inlet DN150 Ø168 R A Ø 203 175 330 X= Wall thickness 155 156 NOTES: (a) by customer Nr.4 holes Ø14 on 235 D.B.C. D3400I18 www.esapyronics.com 27

EMB-7-CH4 OVERALL DIMENSIONS CH4 inlet Rp 2" 226 185 225 442 AIR inlet DN 150 Rp 2" X = WALL THICKNESS Rp 2" 217 Ø195 Ø207 Min=100mm (b) 67 Min=100mm (b) Gas orifice flowmeter (included) Assembly by customer Nr.4 holes Ø18 (a) NOTES: (a) Suitable on customer request (b) by customer Ø 360 (a) Ø 400 (a) D3400I19 www.esapyronics.com 28

EMB-7 LPG OVERALL DIMENSIONS 454 ±5 125 44 75 Premix air inlet Rp 1/2" 536 217 225 94 LPG inlet Rp 2" AIR inlet DN 150 X = WALL THICKNESS Ø195 Rp 2" Min=100mm (b) 67 Min=100mm (b) Gas orifice flowmeter (included) Assembly by customer Rp 2" Ø207 Nr.4 holes Ø18 (a) NOTES: (a) Suitable on customer request (b) by customer Ø360 (a) Ø400 (a) D3400I20 www.esapyronics.com 29

EMB-8-CH4 OVERALL DIMENSIONS 226 152 160 GAS INLET DN 80 647 270 AIR inlet DN 200 X = WALL THICKNESS 217 Ø219.1 Ø88.9 Min.=100mm (b) 42 Min.=100mm (b) Ø88.9 Ø231 Nr.4 holes Ø18 (a) Gas orifice flowmeter (included) Assembly by customer NOTES: (a) Suitable on customer request (b) by customer Ø360 (a) Ø400 (a) D3400I21 www.esapyronics.com 30

EMB-8 LPG OVERALL DIMENSIONS 454 ±5 125 44 75 Premix air inlet Rp 1/2" 150 GAS INLET DN 80 635 270 AIR inlet DN 200 Ø88.9 215 X = WALL THICKNESS 226 Min.=100mm by customer 42 Min.=100mm by customer Ø88.9 Gas orifice flowmeter (included) Assembly by customer Ø 219.1 Ø 231 Nr.4 holes Ø18 (a) NOTES: (a) Suitable on customer request (b) by customer Ø 360 (a) Ø 400 (a) D3400I22 www.esapyronics.com 31

ORDERING CODE FOR COMPLETE BURNER EMB - - - - - - 01 02 03 04 05 06-07 Model 01 04 Flame length EMB-0 EMB-1 EMB-2... (see capacity table) 0 1 2... 05 Short flame ( 2 ) Long flame ( 3 ) Ignition and detection FC* FL ( 5 ) Gas adjuster 02 Ign. + det. Electrode Mono electrode Pilot burner ( 4 ) E* M P With gas adjuster Without gas adjuster GA* F 06 "X" flanged tube length Fuel 03 Indicate the length in mm (see overall dimenions)... Natural gas LPG Poor gas ( 1 ) CH4 GPL GP 07 Type of flanging According to ESA drawing According to Client's drawing E* C The codes marked with an asterisk (*) indentify the standards. Notes: 1 Particular performance according to gas characteristics 2 Standard version for free flame applications 3 Version for applications with burner placed in open tube. Available up to version 4. 4 Available in the 3,4,5 and 6 models (see "ignition and detection"paragraph). 5 In open radiant tube applications. www.esapyronics.com 32