HYDRAULIC APPLICATION Conveyors Textile machines Mining machinery Machine tools Ventilators Construction plant equipment and access platforms etc. CONTENTS Specification data... 5 Function diagrams... 6 8 Dimensions and mounting... 9 Shaft extensions... 10 Permissible shaft loads... 10 Order code... 11 GENERAL Displacement, [cm /rev.] Max. Speed, [RPM] Max. Torque, [danm] Max. Output, [kw] Max. Pressure Drop, [bar] Max. Oil Flow, [l/min] Min. Speed, [RPM] Pressure fluid O Temperature range, [C] 2 Optimal Viscosity range, [mm /s] Filtration OPTIONS Model- Spool valve, gerotor With or without flange Side and rear ports Series with pressure valve(s) Shafts- straight and splined Metric and BSPP ports Speed sensoring; 8,2 00 19 1,1,5 1,8 2, 70 16 Mineral based- HLP(DIN 5152) or HM(ISO 67/) -0 90 75 ISO code /16 (Min. recommended fluid filtration of micron) P Series with Integrated Internal Crossover Relief Valve A B, p= bar ( bar) A P Series with Integrated Internal Crossover Relief Valve B A, p= bar ( bar) A B B P bar 16 12 8 Pressure Losses D Series with Integrated Internal Crossover Relief Valves A B, p= bar ( bar) A 0 0 2 6 8 10 12 1 16 18 22 2 Q, l/min B
SPECIFICATION DATA 8 12,5 2 0 Displacement [cm /rev.] Max. Speed, [RPM] Max. Torque [danm] peak** Max. Output [kw] Max. Pressure Drop [bar] peak** Max. Oil Flow [l/min] Max. Inlet Pressure, [bar] cont Max. Return Pressure peak** 0- RPM w/o Drain Line or -00 RPM Max. Pressure in 00-800 RPM Drain Line, [bar] >800 RPM 0-max. RPM Max. Return Pressure with Drain Line [bar] peak** Max. Starting Pressure with Unloaded Shift, [bar] Min. Starting Torque [danm] at max. press. drop at max. press. drop Min. Speed***, [RPM] Weight, avg. [kg] F(S) FS P PF D DF 8,2 19 20 1,1 1,5 2,1 1,8 2,6 0 16 0,7 1,0 1,9 2, 2,5 2,6 1 15 190 1,6 2,, 2,,2 0 1,2 1,7 0 2 2, 2,6 0 12 2,5,5 5,1 2,,2 0 2,1 0 2,1 2,5,0 1,8 60 790 5,7 6, 2,,2 0 -,,8 0 2,2 2,6,0,0,1 0 0 6,1 5,7 6,6 1,8,0 80 110 -,,6 2,,1,1,0,2 00 0,5 5,8 8 1,7 2,1 70 90 1 - -,7,8 2,5,,1,,2, * Intermittent operation: the permissible values may occur for max. 10% of every minute. ** Peak load: the permissible values may occur for max. 1% of every minute. *** For speeds of 0 RPM or lower, consult factory or your regional manager. 1. Intermittent speed and intermittent pressure drop must not occur simultaneously. 2. Recommended filtration is per ISO cleanliness code /16. A nominal filtration of micron or better.. Recommend using a premium quality, anti-wear type mineral based hydraulic oil HLP(DIN5152) or HM (ISO 67/). If using synthetic fluids consult the factory for alternative seal materials. 0. Recommended minimum oil viscosity 1 mm²/s at operating temperature C. 5. Recommended maximum system operating temperature is 82ºC. 6. To assure optimum motor life fill with fluid prior to loading and run at moderate load and speed for 15-0 min. 5
Motoren FUNCTION DIAGRAMS 8 12,5 The function diagrams data was collected at back pressure 5 10 bar and oil with viscosity of 2 mm²/s at C. 6
FUNCTION DIAGRAMS 2 The function diagrams data was collected at back pressure 5 10 bar and oil with viscosity of 2 mm²/s at C. 7
FUNCTION DIAGRAMS 0 The function diagrams data was collected at back pressure 5 10 bar and oil with viscosity of 2 mm²/s at C. 8
DIMENSIONS AND MOUNTING DATA max L Porting Rear Ports Mounting Three Bolts Mount 5,±0,1 S -SidePorts max L 5±0,2 11,7±0, F - Oval Mount (2 Holes) P -SidePortswith Single Crossover Relief Valve max L 21,2±0,15 D -SidePortswith Dual Crossover Relief Valve max L C P T (A, B) : xm6-12 mm depth :2xG/8or(M18x1,5)-12mmdepth :G1/8or(M10x1)-10mmdepth Standard Rotation Viewed from Shaft End Pressurized - CW Pressurized - CCW Reverse Rotation Viewed from Shaft End Pressurized - CCW Pressurized - CW 0,±0, 8 12,5 2 0 10 106 109 11 117,5 121,5 S 8 S12,5 S S 2 S 0 S 105 107 110 115 118,5 122,5 P 8 P12,5 P P 2 P 0 P 115 117 1 1 128,5 12,5 D 8 D12,5 D D 2 D 0 D 1 16 19 1 17,5 151,5 1,5 5,5 8,5 1,5 17 21 9
SHAFT EXTENSIONS C - ø16 straight, Parallel key 5x5x16 DIN 6885 Max. Torque,9 danm 0, CK - ø1 Straight, Parallel key 5x5x16 DIN 6885 Max. Torque danm -0,018 0, * M6 min 11 Deep * M6 min 11 Deep SH - ø16,5 Splined, B17x1 DIN 582 Max. Torque, danm 0, * M6 min 11 Deep - Motor Mounting Surface * For F Mounting PERMISSIBLE SHAFT LOAD P a max =80 dan P =160 dan rad The permissible radial shaft load [Prad] is calculated from the distance [L] between the point of load application and the mounting surface: P = rad 600 n X 100 (61,5+L), [dan] P rad dan The drawing shows the permissible radial load when L= mm. If the calculated shaft load exceeds the permissible, a flexible coupling must be used. 10
ORDER CODE 1 2 5 6 7 8 9 10 Pos.1 - Adjustment Option omit - without valve P -Side ports with single crossover relief valve D -Side ports with dual crossover relief valve Pos.2 - Mounting Flange omit - Three bolts mount F -Oval mount, two holes Pos. - Port type (not valid for P and D version) omit - Rear ports S - Side ports Pos. - Displacement code 8-8,2 [cm /rev] 12,5-1 [cm /rev] 2 0 -,0[cm /rev] - 1,8[cm /rev] - 0,0[cm /rev] -,0[cm /rev] Pos. 6 - Ports omit - BSPP (ISO 228) M - Metric (ISO 262) Pos. 7 - Line to controled ** (see page ) /L - B A (left running) /R - A B (right running) Pos. 8 - Valve Rated Pressure *** / / - p= bar - p= bar Pos. 9 - Special Features (see page 6) Pos.10 - Design Series omit - Factory specified Pos. 5 - Shaft Extensions* C - ø16 straight, Parallel key 5x5x16 DIN 6885 VC - ø16 straight, Parallel key 5x5x16 DIN 6885 with corrosion resistant bushing CK - ø1 straight, Parallel key 5x5x16 DIN 6885 SH - ø16,5 splined, B17x1 DIN 582 NOTES: * The permissible output torque for shafts must not be exceeded! ** For P option useful only. *** For P and D option useful only. The hydraulic motors are mangano-phosphatized as standard. F - FLANGE KIT (2 Holes) Order No:8 01 00 Flange Kit includes screws - M6x1 for attaching flange to the motor. 11