Solar Power Switchgear & Energy Storage Renewable Energy Systems

Similar documents
Generator/Loadbank Quick Connection Tap Box

Generator Quick Connection Tap Box WM Series

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches

SWITCHGEAR DIVISION PRODUCT PROFILES

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Three-Phase Pole Mounted Recloser

E R C. R E R C ; ; W T E C

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

C1000 Series Automatic Cap Bank

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

A. Submit manufacturer's literature and technical data before starting work.

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

MEDIUM VOLTAGE PRODUCTS

Tradition. Technology. Innovation.

Solid Dielectric, Three Phase Reclosers Catalog O-vs18

Switchgear Skid, C1192

INTERCONNECTION REQUIREMENTS INVERTER-BASED DISTRIBUTED GENERATION SOURCES FOR SINGLE-PHASE CUSTOMER SERVICES

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Metal-enclosed medium-voltage power factor correction system

Critical Power Switchboards. Selection and Application Guide

RPS Station. Solutions for the North American Solar Market

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

ENGINEERING SPECIFICATION

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Solid Dielectric, Triple Option Reclosers Catalog O-vst14

Copyright 2003 Advanced Power Technologies, Inc.

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

BUSWAY Low Voltage (Pow-R-Flex)

Solid Dielectric, Single Phase Recloser

solutions RUS accepted

Cobra-S. Catalog Cobra-S

Chapter 6 Generator-Voltage System

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Schneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

University of Houston Master Construction Specifications Insert Project Name

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

COMPACT SUBSTATION GUIDE

Horizontal Circuit Switchers

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

Electrical Switchgear Replacement Montgomery County Community College

Solid Dielectric, Single Phase Reclosers

Modular medium-voltage switchgear. NorMax

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

MEDIUM VOLTAGE AIS ANSI SWITCHGEAR Advance and Advance 27. Non-arc-resistant MV ANSI switchgear

Solid Dielectric, Independent Pole Operated Reclosers Catalog O-vst16

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

Metal-enclosed medium voltage power factor correction system

Publication No.: PSG

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

RUS accepted Catalog O-vst18

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

with Vacuum Circuit Breaker HAF

ABB central inverters PVS to 2091 kva

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

Integrated Power Solutions

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

ASCO Low Voltage Automatic Transfer Switch Systems

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Small Electrical Systems (Microgrids)

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

Elastimold. Cable Accessories. Underground Distribution Switchgear. Molded Vacuum Switches and Fault Interrupters

Extensible Unit - VCE2a

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems

Submersible Vacuum Fault Interrupters

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Green Building Technology

7. SERVICES OVER 600 VOLTS

Horizontal Circuit Switchers

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

GROUP D. Switch & Protective device.

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

EMPAC Metal enclosed capacitor bank for wind applications

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

MV Metalclad Switchgear 4760V-15000V 20KA-63KA. AC Power Circuit Breaker Rating Structure. Test Procedures for Power Circuit Breakers

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

Medium Voltage. ANSI C37.20 and NEMA SG-5

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Energy Security Electrical Islanding Approach and Assessment Tools. Dr. Bill Kramer Senior Research Engineer Distributed Energy Systems Integration

Application guide. Tmax Link OEM UL 891 Switchboard Program

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Transcription:

7 Solar Power Switchgear & Energy Storage Renewable Energy Systems - Solution Brochure www.apt-power.com 433 N. 36 th Street PROVIDING A COMPREHENSIVE Lafayette, IN 47905 www.apt-power.com 433 APPROACH North 36 th Street, TO RELIABLE Lafayette, Indiana POWER 47905 Tel. 765-446-2343 765-446-2343

2 Solar Power Plant Equipment Figure 1: Medium Voltage Utility Intertie Switchgear, Step-Up Transformer, Low Voltage Combiner Switchboard, & Grounding System Outdoor Pad mount NEMA 3R Non-Walk-In Balance of System (BOS) Equipment & Services for Solar Farm Systems Costs of implementation of Solar Power Systems continue to go down. Let APT be your source for alternative renewable energy Balance of System (BOS) equipment for Solar Farm Power Systems & Photovoltaic (PV) Power Plants. APT has the resources and expertise to provide safe, reliable, and cost-effective solutions for the collection of solar generated power for utility scale grid tie and microgrid applications. No matter how large or small, simple or complex the site is, APT has you covered from the inverters to Point of Common Coupling (PCC) in utility applications or connection to a micro-grid for power distribution with the following: Solar Site Planning, One-Line Diagram Development, Engineering and Design Review Low and Medium Voltage Utility Intertie Switchgear according to IEEE 1547 and Utility Company requirements. Advanced microgrid controls for peak shaving, paralleling with utilities, other generators and islanding Integration of battery storage and motor-generators for increased microgird stability, transient response and improved motor starting Outdoor Walk-In PV Combiner & Utility Intertie Switchgear Modules with sheltered working and maintenance rooms Custom Energy Storage Systems Low to Medium Voltage Solar Step-up Transformers Outdoor NEMA 3R Non-Walk-In Solar Application Specific Solar PV Power Combiner Switchgear, Custom AC Switchboards and AC Panelboards Solar PV Effective Grounding Equipment including grounding transformers. Pole Mounted or Pad Mounted Low and Medium Voltage Gang-Operated Disconnect Switches, Fuses, Surge Arresters, and Cut-Outs Go Solar California! approved Solar Power Metering o For more information on the California Solar Initiative (CSI) and Go Solar California!, visit http://www.gosolarcalifornia.ca.gov/ Remote Monitoring SCADA systems On-site Commissioning Assistance and Training

3 Utility Interconnection for Solar Farms Figure 2: Pole Mount Fused Cutouts Disconnect Switches Figure 3: Utility Intertie Switchgear with Isolated Controls NEMA 3R Figure 4: Inside Utility Intertie Protection & Generator Interrupter Switchgear Utility Intertie Protection & Solar Generation Intertie Switchgear System Voltage range: o 2.4 kv 38 kv, 60/50 Hz Design Amperages: o Up to 3000A Produced to the following standards: o ANSI/IEEE C37.20.2 - Metal-Clad Switchgear or ANSI/IEEE C37.20.3 Metal-Enclosed Switchgear o IEEE 1547 -IEEE Standard for Interconnecting Distributed Resources with Electric Power Main bus: o Insulated silver plated copper, with bolted connections covered by insulating boots Symmetrical Interrupting Capacity (5-15 kv): o 25kA, 40kA or 50 ka o Typical system voltage: 2.4kV, 4.16kV,12.47kV, 11kV, 13.2kV, 13.8kV Draw-out or Fixed mount Vacuum Circuit Breakers with visible disconnect Protective Relay Functions as required Distribution or Station class surge arresters Self-derived control power with on-site convenience receptacle Integrated Battery System Advanced Power Metering o UL recognized ANSI C12-20-1998 Class 10 0.5% Accuracy Enclosure o Available in NEMA 1 (indoor) and NEMA 3R (outdoor) installation. o Carbon steel, Stainless or Aluminum o Powder coated ANSI 61 Gray. o All hardware is stainless steel. o Door handles are padlockable. Optional Features: o Undervoltage release o o Metal Clad Construction 3-pole Gang-Operated dead-break Visible Disconnect Switch

4 Generated Solar Power Combination Solutions Figure 4: 600A Solar Combiner Panelboard Figure 5: 2000A Solar Collector Switchboard Low Voltage Utility Intertie, Combiner/Aggregation Switchboards & Panelboards Application: o Utility Intertie Protection o Overcurrent Protection o Visible Disconnect o Aggregation of String Inverters and Micro Inverters o Station services Applicable standards: o IEEE 1547 - IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems o UL 891 Standard for Switchboards o UL 67 Standard for Panelboards Voltage: o 208V 690V, 3Ø, 3 or 4 Wire Frequency: o 60Hz or 50Hz Surface Mountable Panelboard o Main Circuit Breaker or Main Lugs Only o Fourteen (14) 3-pole Feeder Circuit Breakers maximum per section Floor Standing Switchboard o Standard bus ampacity up to 4000A o Silver plated copper bus o Busbar connections with NEMA standard hole pattern o Bus Access & Cable Entry: Front Access for bottom cable entry o Insulated Case Main Circuit Breaker o Molded Case Feeder Circuit Breakers o Revenue Grade Current Transformers o Advanced Power Metering UL recognized ANSI C12-20-1998 Class 10 0.5% Accuracy o Enclosure: Manufactured from Carbon Steel Powder coated ANSI 61 Gray Lockable handles NEMA 1 (indoor) or NEMA 3R (outdoor) NEMA 3R Internal Climate Control Anti-condensation Heater w/ Thermostat.

5 Power Transformers & Grounding Systems Figure 6: 2000kVA Solar Step-Up Power Transformer Figure 7: Effective Grounding System Equipment Power Transformers Effective Grounding Systems Application: o Step up Solar Generated Voltage for use on the utility grid Oil Filled Pad mount Ratings: o 500kVA 4000kVA Voltage: o LV: 208V 690V o MV: 2.4kV 38kV Frequency: o 60Hz or 50Hz Outdoor NEMA 3R Paint Finish: o Munsell 7GY 3.29/1.5 Padmount Green Application: o Provide effective grounding to solar generator side to meet utility intertie requirements for grounding APT calculations can be provided to the Owner to demonstrate conformance to the design criteria. Current sensing outputs for ground fault tripping. Enclosure o Carbon steel. o Enclosure can be UL508A listed for NEMA 3R outdoor applications. o Powder coated ANSI 61 Gray with custom colors available. o All hardware is stainless steel. *Actual product may look different from images shown, based on actual specifications.

6 Energy Storage & Outdoor Walk-In Modules Figure 8: Solar Generated Power Battery Energy Storage System (BESS) APT Solar Generated Power Battery Energy Storage System (BESS) can be stand alone, outdoor NEMA 3R or fully integrated with low voltage switchboards, transformers, and medium voltage switchgear all in a single Outdoor Walk-In ISO Container Based Solar Power Combination Module APT Battery Energy Storage System (BESS) shall be sized in accordance with desired operating specifications Fully integrated solar power module comes pre-wired from the factory and only external connections need to be made upon installation, Fast and clean installation allows for less installation time and more generation time. Figure 9: Outdoor Walk-In ISO Container Based Solar Power Combination Module