6100H, 4, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc pplication Valve is designed f use in SI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications with 0% leakage. Typical applications include cooling tower bypass, primary flow change-over systems, and large air handler coil control. Jobsite ote Valve assembly should be sted in a weather protected area pri to installation. Reference the butterfly valve installation instruction f additional infmation. low/v v 10 v 20 v 30 v 40 v 50 v 60 v 70 v 80 v 90 0.3 17 36 78 139 230 364 546 600 Suitable ctuats on-spring lectronic ail-safe 6100H 2*GM(X), R(X), PR(X) PKR(X) ate created, 03/16/2017 - Subject to change. elimo ircontrols (US), Inc. Technical ata 1893 Service chilled, hot water, up to 60% glycol low haracteristic modified equal percentage ontrollable low Range 90 rotation Size [mm] 4 [100] nd itting use with SI lass 125/150 flanges ody ductile iron STM 536 ody inish epoxy powder coated Stem Packing PM (lubricated) Seat PM Shaft 416 stainless steel ushings RPT isc 304 stainless steel ody Pressure Rating [psi] SI 125, standard class umber of olt Holes 8 ug Threads 5/8-11 U Media Temperature Range -22 to 250 [-30 to 120 ] (Water) lose-off Pressure 200 psi Rangeability 10:1 (f 30 to 70 range) Maximum Velocity 12 PS v 600 Weight 12.6 lb [5.7 kg] eakage 0% Servicing maintenance free low Pattern % O MXIMUM OW 100 90 80 70 60 50 40 30 20 2*GK, 2*GM 17.9 [454] 2.05 [52] 22.88 18.50 3.94 [100] [580] [470] 10 0 20 10 30 50 40 60 80 70 90 100 % O VV OPIG 800-543-9038 US 866-805-7089 203-791-8396 TI MRI / RI
6100H, 4, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc R PKR 8.5 [217] 2.05 [52] 18.25 21 [533] 3.94 [100] [464] 11.95 2.05 [52] 20.4 [516] 16.20 3.94 [100] [303.5] [411] KR..4(H), R..4(H) 14.1 [358] 2.05 [52] 20.4 [516] 16.00 3.94 [100] [406] ate created, 03/16/2017 - Subject to change. elimo ircontrols (US), Inc. 800-543-9038 US 866-805-7089 203-791-8396 TI MRI / RI
6100H, 4, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc PR, PRX 11.95 2.05 [52] 17.86 13.92 3.94 [100] [303.5] [453.6] [353.6] ate created, 03/16/2017 - Subject to change. elimo ircontrols (US), Inc. 800-543-9038 US 866-805-7089 203-791-8396 TI MRI / RI
PKRXUP-MT-T Modulating, lectronic ail-safe Return, 24-240 V, M 4X with net pplication PR Series valve actuats are designed with an integrated linkage and visual position indicats. outdo applications, the installed valve must be mounted with the actuat at above hizontal. indo applications the actuat can be in any location including directly under the valve. ate created, 03/19/2018 - Subject to change. elimo ircontrols (US), Inc. Technical ata 286806 Power Supply 24...240 V, -20% / +10%, 50/60 Hz, 24...125 V, -20% / +10% Power onsumption Running 52 W @ 24 V, 40 W @ 120 V, 40 W @ 230 V Power onsumption Holding 7 W @ 24 V, 8 W @ 120 V, 9 W @ 230 V Transfmer Sizing 55 V @ 24 V/ (class 2 power source), 43 V @ 120 V/, 68 V @ 230 V lectrical onnection terminal block Overload Protection electronic thoughout 0 to 90 rotation Operating Range Y 2 to 10 V, 4 to 20 m variable (V, floating point, on/off) Input Impedance 100 k Ω f 2 to 10 V (0.1 m), 500 Ω f 4 to 20 m, 1500 Ω f On/Off eedback Output U 2 to 10 V, 0.5 m max, V variable ngle of Rotation 90 ominal Tque Min. 1400 in-lbs [160 m] irection of Rotation (Mot) reversible with app irection of Rotation (ail-safe) reversible with app ail-safe Position adjustable with PP 0 to 100% Position Indication top mounted domed indicat Manual Override 7 mm hex crank, supplied Running Time (Mot) default 35 sec, variable 30...120 sec Running Time (ail-safe) <30 sec ridge Time programmable 0 to 10 sec (2 sec default) delay befe fail-safe activates Pre-charging Time 5 to 20 seconds mbient Humidity 5 to 100% RH (U Type 4) mbient Temperature Range -22 to 122 [-30 to 50 ] Housing M 4X, IP66/67, U nclosure Type 4 Housing Material luminum die cast and plastic casing gency istings cuus acc. to U60730-1/-2-14, /S 60730-1:02, acc. to 2004/108/ and 2006/95/ oise evel (Mot) 68 d () oise evel (ail-safe) <62 d () Servicing maintenance free Quality Standard ISO 9001 Weight 14.1 lbs [6.4kg] uxiliary switch 2 x SPT, 3 resistive (0.5 inductive) @ 250 V, one set at 10, one adjustable 0 to 90 ommunication net MS/TP Passive Sens Inputs 2 (PT1000) (I1000) (T) egree of Protection I/ IP66/67 efault/onfiguration efault parameters f 2 to 10 V applications of the PKR..-MT actuat are assigned during manufacturing. If required, different parameters of the actuat can be dered. These parameters are variable and can be modified by facty pre-set, the handheld ZTH US using the elimo pp on a smart phone with ear ield ommunications () programming. Operation The PR series actuat provides 90 of rotation and a visual indicat shows the position of the valve. The PR Series actuat uses a low power consumption brushless mot and is electronically protected against overload. universal power supply is furnished to connect supply voltage in the range of 24-240 V and 24-125 V. Included is a smart heater with thermostat to eliminate condensation. Two auxiliary switches are provided; one set at 10 open and the other is field adjustable. Running time is field adjustable from 30-120 seconds by using the ear ield ommunication () app and a smart phone. Use 60 /75 copper wire size range 12-28 WG, stranded solid. Use flexible metal conduit. Push the listed conduit fitting device over the actuat s cable to butt against the enclosure. Screw in conduit connect. Jacket the actuats input wiring with listed flexible conduit. Properly terminate the conduit in a suitable junction box. Rated impulse Voltage 4000V. Type of action 1. ontrol pollution degree 3. 800-543-9038 US 866-805-7089 203-791-8396 TI MRI / RI
PKRXUP-MT-T Modulating, lectronic ail-safe Return, 24-240 V, M 4X with net Wiring iagrams Meets cuus requirements without the need of an electrical ground connection. UP 46 Universal Power Supply (UP) models can be supplied with 24 V up to 240 V, 24 V up to 240 V. isconnect power. Provide overload protection and disconnect as required. Two built-in auxiliary switches (2x SPT), f end position indication, interlock control, fan startup, etc. Only connect common to negative (-) leg of control circuits. ctuats may be controlled in parallel. urrent draw and input impedance must be observed.! WRIG! IV TRI OMPOTS! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to wk with live electrical components. Have a qualified licensed electrician other individual who has been properly trained in handling live electrical components perfm these tasks. ailure to follow all electrical safety precautions when exposed to live electrical components could result in death serious injury. On/Off UP! 1 46 ommon + Hot Input W (open) Input W (close) UP! 1 46 ommon + Hot Input W (open) Input W (close) loating Point UP 1 5 46 Modulating net - + Y 3 U5 om - 24 V Out (max 5m) Y 3 0-10 V, 4-20 m U5/MP 0-10 V om + - om acnet + - ate created, 03/19/2018 - Subject to change. elimo ircontrols (US), Inc. 800-543-9038 US 866-805-7089 203-791-8396 TI MRI / RI
PKRXUP-MT-T Modulating, lectronic ail-safe Return, 24-240 V, M 4X with net T1 om T1 T2 om T2 Temperature Senss 1 4 0 to 90 default 85 uxiliary Switches ate created, 03/19/2018 - Subject to change. elimo ircontrols (US), Inc. On/Off UP! 1 46 ommon + Hot Input W (open) Input W (close) 800-543-9038 US 866-805-7089 203-791-8396 TI MRI / RI