LK Position Switches TECHNICAL DATASHEET.

Similar documents
Position switches FC series

FL series position switches

Position switches FD series

Position switches FR series

Switches with manual reset

Position switches FR series

LR-LX-LK-LW Safety Switches with separate actuator

Safety rope switch with reset for emergency stop

Safety rope switches with reset for emergency stop

Safety switches with separate actuator

Safety switches for hinges

SFS-UFS Single Foot Switches

Microswitches MK series

Safety switches for hinged doors

Safety switches with separate actuator

Safety rope switch without reset for simple stop

Safety switches for hinged doors

Prewired position switches FF series

Safety switches with solenoid and separate actuator

Single foot switches - PX and PA series

Single foot switches PX and PA series

Prewired position switches FF series

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive

Microswitches MK series

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Microswitches MK Series

Single foot switches PX and PA series

Microswitches M series

Safety switches with solenoid and separate actuator

Rope safety switches with reset for emergency stop

Limit Switches - Limit Type (PS21L) Metal Body IP66

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Miniaturized limit switches

Safety Limit Switch

Limit switches 3. Page 92. Page 92

Limit Switch - Prewired Type Metal Body

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

FOOT SWITCHES

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Pre wired limit switches

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

Compact plastic limit switches with positive opening mechanism

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

AF40... AF96 3-pole contactors Technical data

Safety Limit Switches

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

Compact plastic limit switches with positive opening mechanism

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Hinged Safety Door Switch

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Automation - Lift - Handling System - Atex

Manual Reset Limit Switch

Pendant control stations 6

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

HS5D Miniature Interlock Switches

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

D4BS CSM_D4BS_DS_E_8_4

General_technical_data Series

Selection diagram. Actuators. Bodies. Contact blocks. Cable entry AB BB CB. Thermoplastic

Standard Interlock Safety Switches

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

PRODUCT SPECIFICATION. Foot Switches. Series.

Gross Automation (877)

2NC (slow-action) Direct. Model. opening

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Cylindrical fuse-link

D4NH CSM_D4NH_DS_E_7_1

Safety-door Switch. Ordering Information

Limit switches. Metal. Limit Switches Metal casing, 30mm, 40mm & 60mm

XACA871 pendant control station XAC-A - 8 pushbuttons

HS5D Miniature Interlock Switches

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

General_technical_data Series

Safety Limit Switch

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

HS1L Interlock Switches with Solenoid

Manual Motor Starters. Meta-MEC

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Special Purpose Fuses

YFC. Limit switch. Ex d. 24 operating head types

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Standard Interlock Safety Switches

Safety switches with solenoid and separate actuator

SG-B1 SERIES / SG-A1 SERIES

Transcription:

LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions with gold-plated silver contacts Approvals General data Ambient temperature: 25 C +80 C Max. actuation frequency: 600 operating cycles 1 /hour Mechanical endurance: million operating cycles 1 Mounting position: any Safety parameters: B d :,000,00 for NC contacts Mechanical interlock, not coded: according to EN ISO 1 One operation cycle means two movements, one to close and one to open contacts, as defined in EN 6094 5 1. Cable cross section (flexible copper strands) C, C4: min. 1 x 0.4 mm 2 (1 x AWG ) max. 2 x 1.5 mm 2 (2 x AWG 16) Contact block C: min. 1 x 0.5 mm 2 (1 x AWG ) max. 2 x 1.5 mm 2 (2 x AWG 16) In conformity with standards: IEC 6094-5-1, EN 6094-5-1, EN 6094-1, EN 04, IEC 604-1, EN 604-1, EN ISO 1, EN ISO 0, IEC 60529, EN 60529, UL 8, CSA.2 No.. Approvals: IEC 6094 5 1, UL 8, CSA.2 No., GB8.5 01. In conformity with the requirements of: Low Voltage Directive 06/95/EC, Machinery Directive 06/42/EC and EMC Directive 04/8/EC. Positive contact opening in conformity with standards: IEC 6094 5 1, EN 6094 5 1. Installation for safety applications: Use only switches marked with the symbol aside the product code. Always connect the safety circuit to the NC contacts (normally closed contacts: C11-C, C21-C or C1-C2) as stated in standard EN 6094 5 1, encl. K, par. 2. Actuate the switch at least up to the positive opening travel shown in the travel diagrams. Operate the switch at least with the positive opening force, indicated between brackets below each article, aside the minimum force value. Electrical data Utilization category without connector Thermal current (Ith): A Rated insulation voltage (Ui): 0 Vac 600 Vdc 0 Vac 0 Vdc (contact blocks, 4) Rated impulse withstand voltage (U imp ): 6 kv 4 kv (contact block, 4) Conditional short circuit current: 00 A according to EN 6094 5 1 Protection against short circuits: type am fuse A 0 V Pollution degree: Alternating current: AC ( 60 Hz) Ue (V) 2 0 0 Ie (A) 6 4 1 Direct current: DC1 Ue (V) 5 2 Ie (A) 6 1.1 0.4

Characteristics approved by UL Utilization categories Q00 (69 VA, 5 2 Vdc) A600 ( VA, 1 600 Vac) Data of housing, 4X indoor use only,, 1 For all contact blocks except C2 and C use 60 or 5 C copper (Cu) conductor, rigid or flexible, wire size AWG /. Terminal tightening torque of.1 lb in (0.8 Nm). For contact blocks C2 and C use 60 or 5 C copper (Cu) conductor, rigid or flexible, wire size AWG. Terminal tightening torque of lb in (1.4 Nm). In conformity with standard: UL 8, CSA.2 No.

Selection diagram A01 A08 A A02 AA2 AA4 A05 AA5 A0 external rubber gasket external rubber gasket external rubber gasket external rubber gasket A A21 A25 A4 A A A69 A5 round rod, stainless steel square rod fiber glass rod porcelain roller WITH RESET A01-R A02-R A05-R A0-R A-R A0-R A1-R A51-R ACTUATORS CONTACT BLOCKS C C C4, slow action 1NO-1NC snap action slow action CONDUIT ENTRY Threaded conduit entry 16 M16x1.5 (standard) PG 11 With cable gland X for cables from Ø 5 to Ø mm X for cables Ø Ø mm product options accessory sold separately

AA A A-R A16 A A1 A A1 A6 roller roller roller roller roller Ø mm, Ø mm, Ø mm, Ø 11 mm Ø mm stainless steel stainless steel stainless steel external rubber gasket rope switch for signalling A0 A1 A51 A52 A54 A55 A56 A5 A8 adjustable lever adjustable safety lever without actuator LOOSE ACTUATORS A52-R A54-R A56-R A5-R A8-R without actuator Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. LK C A02 - R 1 G 16 X R2 H6 Housing technopolymer, one conduit entry LK Contact Blocks 1NO-1NC, snap action C, slow action C, slow action C4 Actuators short plunger A01 roller lever A02 angled roller lever A05...... Reset without reset (standard) simultaneous reset simultaneous rest, increased force R RF R R2 R R25 R5 R26 R2 H6 Ambient Temp. -25 C +80 C (standard) - C +80 C Rollers standard roller stainless steel, Ø mm (for actuators AA4, A) stainless steel, Ø mm (for actuators AA2, A02, AA5, A05, A0, A1, A51, A52, A54, A55, A56, A5) stainless steel, Ø mm (for actuators A0, A1, A51, A52, A54, A55, A56, A5) technopolymer, Ø 5 mm (for actuators A0, A1, A51, A52, A54, A55, A56, A5) rubber, Ø mm (for actuators A0, A1, A51, A52, A54, A55, A56, A5) rubber, Ø mm (for actuators A51, A52, A54, A55, A56, A5) rubber, protruding, Ø mm External Metallic Parts zinc-plated steel (standard) stainless steel 1 Contact type silver contacts (standard) silver contacts with 1 µm gold coating (not for contact block 2) G Pre-installed Cable Glands without cable gland (standard) X cable gland for cables Ø 5 Ø mm X cable gland for cables Ø Ø mm Additional combinations possible. Contact Technical Support for information. Threaded Conduit Entry 16 M16x1.5 (standard) PG 11

Contact type: R = snap action L = slow action With external rubber gasket With external rubber gasket With Ø mm stainless steel roller on request 11,6 C R C L C4 L 5.9 21.4 6.5 Ø 8 LKCA01-16 1NO-1NC LKCA01-16 LKC4A01-16 6.6.1 6.5 LKCA02-16 1NO-1NC LKCA02-16 LKC4A02-16 type 4 N (25 N ) 6.6.1 6.5 LKCAA2-16 1NO-1NC LKCAA2-16 LKC4AA2-16 type 4. N (25 N ) 6,5 1 6,5 0,8 4,2x,2,2,2,2 LKCAA4-16 1NO-1NC LKCAA4-16 LKC4AA4-16 type 5 4. N (25 N ) 0,8 With external rubber gasket With external rubber gasket 2(29-5) (1-2) 2(29-5) (1-2) C R C L C4 L.5 6.5.4 LKCA05-16 1NO-1NC LKCA05-16 LKC4A05-16 type 4 N (25 N ).5 6.5.4 LKCAA5-16 1NO-1NC LKCAA5-16 LKC4AA5-16 type 4. N (25 N ) 88.5 6.5 52 LKCA0-16 1NO-1NC LKCA0-16 LKC4A0-16 type 4 N (25 N ) group 88.5 6.5 52 LKCAA-16 1NO-1NC LKCAA-16 LKC4AA-16 type N (25 N ) group With external rubber gasket Fixed only by threaded head in vertical position C R C L C4 L 66.6 0.1 6.5 Ø LKCA08-16 1NO-1NC LKCA08-16 LKC4A08-16 2.5 5.8 Mx1 LKCA-16 1NO-1NC LKCA-16 LKC4A-16 Ø.4 2.5 85.1 8.4 25.2 6.5 M x1 LKCA-16 1NO-1NC LKCA-16 LKC4A-16 Ø 8 4 85.1 25.2 8.4 6.5 M x1 LKCA1-16 1NO-1NC LKCA1-16 LKC4A1-16.8 4

Contact type: R = snap action L = slow action Roller, Ø 11 mm, technopolymer Roller, Ø mm, stainless steel R 1 11.6.8.6 C R C L C4 L 64.4 2.9 6.5 LKCA-16 1NO-1NC LKCA-16 LKC4A-16 6 N (25 N ) 6.5 1 6.5 LKCA-16 1NO-1NC LKCA-16 LKC4A-16 68 1.5 6.5 LKCA-16R 1NO-1NC LKCA-16R LKC4A-16R.5 6.5 LKCA16-16 1NO-1NC LKCA16-16 LKC4A16-16 Fixed only by threaded head in vertical position With external rubber gasket With external rubber gasket With external rubber gasket Ø 1.2 1.8 1 M x1 160.5 4 55 Ø 1.5 1 16.5 Ø.5 C R C L C4 L 86 LKCA1-16 1NO-1NC LKCA1-16 LKC4A1-16 6.5 LKCA-16 1NO-1NC LKCA-16 LKC4A-16 1 m/s 6.5 LKCA21-16 1NO-1NC LKCA21-16 LKC4A21-16 1 m/s 6.5 LKCA26-16 1NO-1NC LKCA26-16 LKC4A26-16 1 m/s 0.1 Nm With Ø mm stainless steel roller on request Other rollers available. Square rod, x mm C R C L C4 L 90.5 6.5 54 4.x.2.5 16.5 LKCA0-16 1NO-1NC LKCA0-16 LKC4A0-16 90.5 6.5 54 9.4 1.1 LKCA1-16 1NO-1NC LKCA1-16 LKC4A1-16 4.5-11.5 8-6.5 xx5 4.5 5 LKCA-16 1NO-1NC LKCA-16 LKC4A-16 1.5 m/s 161.5 5 55 6.5 Ø. 2.5.5 LKCA4-16 1NO-1NC LKCA4-16 LKC4A4-16 1.5 m/s

Contact type: R = snap action L = slow action Round rod, Ø mm, stainless steel Other rollers available. Other rollers available. Porcelain roller C C C4 R L L 4.5-11.5 8-6.5 øx5 4.5 5 LKCA-16 1NO-1NC LKCA-16 LKC-16 1.5 m/s 9 59 6.5 54 LKCA51-16 1NO-1NC LKCA51-16 LKC4A51-16 4.1 6.6 6.5 29 LKCA52-16 1NO-1NC LKCA52-16 LKC4A52-16.8 99. 6.5 56.5 Ø 9.5 2.5 LKCA52-16 1NO-1NC LKCA5-16 LKC4A5-16 0.5 m/s 0.02 Nm (0.25 Nm ) group 6 Other rollers available. Other rollers available. Other rollers available. Other rollers available. C R C L C4 L 9 59 6.5 25 44 LKCA54-16 1NO-1NC LKCA54-16 LKC4A54-16 89.5-8.5 5-1 6.5 29 LKCA55-16 1NO-1NC LKCA55-16 LKC4A55-16 89.5-8.5 5-1 6.5 29 LKCA56-16 1NO-1NC LKCA56-16 LKC4A56-16 98.5 62 6.5 LKCA5-16 1NO-1NC LKCA5-16 LKC4A5-16 Fiber glass rod Rope switch for signalling Ø6x0 6.5 C R C L C4 L 4.5-4.5 6.5 8-8 4.2X.2 LKCA69-16 1NO-1NC LKCA69-16 LKC4A69-16 1.5 m/s 8.8. 9.6 6.5 LKCA6-16 1NO-1NC LKCA6-16 LKC4A6-16 2NO 0.5 m/s initial N - final N group

IMO Precision Controls devices with fitted reset facility, and when reset allows the device to trip when actuator is operated. The new device is a block inserted between the switch body and the head, and could be rotated independently, and positioned in any of the possible four. This new device has following advantages: The reset device can be integrated into almost all standard actuator heads with snap action are no longer necessary because the tripping movement is made by the reset device itself The reset device can be rotated independently from the head for maximum flexibility during installation Two driving forces: standard and increased for applications with vibrations Mechanical endurance: 1 million operating cycles. Contact type: R = snap action L = slow action 2(29-5) (1-2) C L C4 L 0.9 4.4 6.5 Ø8 4 LKCA01-R16 LKC4A01-R16 4. 89.6 5.1 6.5 4 LKCA02-R16 LKC4A02-R16 type 4 N (25 N ) 90 6.5.4 4 LKCA05-R16 LKC4A05-R16 type 4 N (25 N ) 1.5 65 6.5 4 LKCA0-R16 LKC4A0-R16 type 2. group With Ø mm stainless steel roller on request With Ø mm stainless steel roller on request Other rollers available. Other rollers available..2 42.1 16.1.2 9.4.2 54.9 11.6 1.1.6 6 6 2 C L C4 L 80.5 44 6.5 4 LKCA-R16 LKC4A-R16 4..5 6.5 2 LKCA0-R16 LKC4A0-R16 0.0 Nm (0.25 Nm ).5 6.5 2 LKCA1-R16 LKC4A1-R16 0.0 Nm (0.25 Nm ) 8.5 6.5 2 9.5 LKCA51-R16 LKC4A51-R16 0.0 Nm (0.25 Nm ) Other rollers available. Other rollers available. Other rollers available. Other rollers available..2.4.2 44.4.2.4 0.1.2.4 C L C4 L 11.1 80.6 6.5 2 0.1 LKCA52-R16 LKC4A52-R16 0.0 Nm (0.25 Nm ) 8.5 6.5 2 2 26 LKCA54-R16 LKC4A54-R16 0.0 Nm (0.25 Nm ) 66-5 2.5-161.5 6.5 2 LKCA56-R16 LKC4A56-R16 0.0 Nm (0.25 Nm ) 111.5 5 6.5 2.1 LKCA5-R16 LKC4A5-R16 0.0 Nm (0.25 Nm )

Position switches with revolving lever without actuator Contact type: R = snap action L = slow action 9 0.9 With manual reset knob.2 9 0.9 IMPORTANT For safety applications: join only switches and actuators marked with symbol aside the product code. C R C L C4 L 6.5 LKCA8-16 1NO-1NC LKCA8-16 LKC4A8-16.5 6.5 M4 2 LKCA8-R16 LKC4A8-R16 0.0 Nm (0.25 Nm ) Increased actuating force The switch can be delivered with increased actuating force (option RI). Ideal for applications with vibrations. Actuators A01, A, A, A16 N A02, A05 6 N A0.5 N A0... A5 0.08 Nm Loose actuators IMPORTANT: These loose actuators can be used with items of series LR, LM, LX, LZ and LK only. Ø mm Ø mm Adjustable square rod, xx5 mm Flexible rod with pointed end Adjustable round rod Ø x5 mm Ø mm 5 5 11.2 5 0.2 8. xx5 4.5 5-116 6 55 Ø x5 4.5 5-116 2.5 11.5 1 1 Ø6x0 49 1 80 Ø 9 5 5 1.5 4-9 4-9 4 11 6.5 2.5 11.5 AC-CAE0 AC-CAE1 AC-CAE AC-CAE4 AC-CAE AC-CAE51 Ø mm Porcelain roller Ø mm Adjustable actuator with technopolymer roller Adjustable safety actuator with technopolymer roller Ø mm Adjustable fiber glass rod - 9 AC-CAE52 AC-CAE5 (2) CA-CAE54 AC-CAE55 AC-CAE56 AC-CAE5 AC-CAE69 - Actuator AC-CAE55 can only be used in safety applications if adjusted to its max. length, as shown in figure beside. If you need an adjustable lever for safety applications, use the adjustable safety lever AC-CAE56. - (2) The position switch obtained by assembling switch LK A8-16 (e.g. LKC5A8 16, LKC6A8 16 ) with actuator AC-CAE5 will not present the same travel diagrams and actuating forces as switch LK A5 J016ST (e.g. LKC5A5 J016, LKC6A5 J016ST ). - The actuator cannot be rotated to the inside because it will mechanically interfere with the switch head. 9

Special loose actuators IMPORTANT: These loose actuators can be used with items of series LR, LM, LX, LZ and LK only. Stainless steel rollers, Ø mm 1 1 6 0.8 9.5 1 49 5 1.5 4-9 4-9 4 11 AC-CAE1-R AC-CAE51-R AC-CAE52-R AC-CAE54-R AC-CAE55-R AC-CAE56-R AC-CAE5-R s, Ø 5 mm 5 5 0.8 9.5 0.8 9.5 9.5 5 8 9.5 5 1.5 5 4.5 4.5 5 5.8.5 56.1 4.5 4.5-1. - 1..5 AC-CAE1-R25 AC-CAE51-R25 AC-CAE52-R25 AC-CAE54-R25 AC-CAE55-R25 AC-CAE56-R25 AC-CAE5-R25 Rubber rollers, Ø mm 46 11.5 26 59 16 52.5 -.5 -.8 5 AC-CAE1-R5 AC-CAE51-R5 AC-CAE52-R5 AC-CAE54-R5 AC-CAE55-R5 AC-CAE56-R5 AC-CAE5-R5 Rubber rollers, Ø mm 26 16 55 55 64 58.5-8 58.8-8 58 Protruding rubber rollers, Ø mm AC-CAE51-R26 AC-CAE2-R26 AC-CAE54-R26 AC-CAE55-R26 AC-CAE56-R26 AC-CAE5-R26 11.4-26.4-5 11.4-26.4-5 58.5-8 58.8-8 AC-CAE55-R2 AC-CAE56-R2 Ref: LKSwitch16 Errors and omissions excepted. Subject to change without notice.