AutoLink Frequently Asked Questions

Similar documents
S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

Medium Voltage Outdoor Apparatus Portfolio 2009

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Electronic Resettable Sectionalizer

Improving distribution systems reliability with Cutoutmounted single phase Reclosers

Fusesaver specification form

10DD 10DD-1. Section CAUTION:

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

David Park, EPMV ABB South Africa / Africa Channel Partner event, 2016 ABB Africa Channel Partner event Medium Voltage Apparatus

ABB Automation & Power World: April 18-21, 2011 WPO MV outdoor products for smart grid demands. ABB Inc. April 19, 2011 Slide 1

Companion II 8.3kV, 17.2kV and 23kV 12K - 40K Backup Fuses

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

TABLE OF CONTENTS Page:

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

EE 741 Over-voltage and Overcurrent. Spring 2014

Submersible Vacuum Fault Interrupters

Padmount Solid Dielectric Switchgear Catalog

Three-Phase Pole Mounted Recloser

Source-Side Fuse/Load-Side Recloser Coordination

Table 1.-Elemsa code and characteristics of Type K fuse links (Fast).

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Type ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB

Zone Selective Interlocking

Functional Overview and Operating Principles for the AR-OH and AR360 Overhead AutoRANGER Fault Indicators

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

Elastimold. Cable Accessories. Underground Distribution Switchgear. Molded Vacuum Switches and Fault Interrupters

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Shippensburg University

Pretest Module 29 High Voltage Unit 1

Horizontal Circuit Switchers

Transmission Switching

Automatic Electronic Sectionalizing

Horizontal Circuit Switchers

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Section 1 Introduction to the Presentation

Typical Specification

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

Designing and Maintaining a Pollution-Resilient Electric Power System. Managing Pollution Issues

SWITCHGEAR DIVISION PRODUCT PROFILES

MDS Dead-front Padmount Switchgear Style Guide 1VAM SG May 2010 Revision D

Transformer Protection

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Faulted Circuit Interrupting Tests on Type CMU Power Fuses

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Fisher Pierce. Cable Accessories. Faulted Circuit Indicators. Series 1548 Overhead FCIs

Cobra-S. Catalog Cobra-S

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Application Engineering

SF 6 Gas Insulated Load Break Switch

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Cooper Bussmann Products And Technical Support Delivered Worldwide

GROUP D. Switch & Protective device.

Fused Coordination Panelboard

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

TYPES DS II AND DSL II METAL ENCLOSED LOW VOLTAGE POWER CIRCUIT BREAKERS

When power interruptions happen.

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

OVERALL LENGTH (B) " ( mm) " ( mm) " ( mm) " ( mm)

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Miniature circuit breaker Application guide

Application of Sepam Relays for Arc Flash Hazard Reduction at Low Voltage Switchgear

Solid Dielectric, Single Phase Recloser

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Potential Negative Impact on Reliability of Distributed Generation under Temporary Faults

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

Application Engineering

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

K-SEC 030. Fusing Equipment. Kearney Fuse Links GENERAL INTERNAL CONSTRUCTION SINGLE TIN ELEMENT

Faulted Circuit Interrupting Tests on Type CMU Power Fuses

Fused Coordination Panelboard

Edison modular fuse, vault application products

SURE-TRIP OEM RELACEMENT TRIP UNIT

PROTECTION AND CONTROL

X-Limiter full-range current-limiting fuse

Solid Dielectric, Single Phase Reclosers

Elastimold Molded Reclosers, Switches & Switchgear. In this section... Elastimold. Molded Reclosers,

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

RUS accepted Catalog O-vst18

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Product Selection Guide

High-voltage high-breaking capacity VV fuse-links

Medium Voltage Metal-Enclosed Switches

5. OVERCURRENT RELEASE (OCR)

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Transcription:

Rev. 3 October 2013 Page 1 of 8 AutoLink Frequently Asked Questions October 2013 1

Rev. 3 October 2013 Page 2 of 8 Table of Contents 1 Background... 4 1.1 What is the AutoLink Single Phase Electronic Sectionalizer?... 4 1.2 What is the main function of the AutoLink?... 4 1.3 Does the AutoLink replace a fuse?... 4 1.4 How does the AutoLink operate?... 4 1.5 How many reclose operations can the AutoLink see?... 4 1.6 What are the available pickup levels in the AutoLink?... 4 1.7 When does the AutoLink reset its counter?... 4 1.8 What is the shortest open time?... 4 1.9 What is the longest open time?... 5 1.10 How many models of AutoLink are available?... 5 1.11 Where is the manufacturing located?... 5 1.12 Where do I get support for the AutoLink?... 5 2 Technical features... 5 2.1 What standard does the AutoLink comply with?... 5 2.2 What is the maximum pass-through current for the AutoLink?... 5 2.3 What type of faults does the AutoLink detect?... 5 2.4 What is the AutoLink life-span?... 5 2.5 Can the AutoLink be bench tested?... 6 2.6 Does the AutoLink measure voltage?... 6 2.7 When does the AutoLink know that the line is open?... 6 2.8 Does the AutoLink detect transformer energization inrush currents?... 6 2.9 What is the AutoLink Ingress Protection rating?... 6 3 Installation and Operation... 6 3.1 Which cutout bodies are suitable for AutoLink installation?... 6 3.2 What is the minimum load current required for the AutoLink to be operational?... 6 2

Rev. 3 October 2013 Page 3 of 8 3.3 Are there spare parts available for the AutoLink?... 6 3.4 Can the AutoLink be opened under load?... 7 3.5 Can the AutoLink be closed in an energized line?... 7 3.6 What are the recommendations for setting the AutoLink?... 7 3.7 How does the AutoLink trip?... 7 3.8 How do I reset the AutoLink after a trip?... 7 4 General... 8 4.1 Does AutoLink improve quality measures and costs?... 8 4.2 Can the AutoLink work in 3-phase mode?... 8 3

Rev. 3 October 2013 Page 4 of 8 1 Background 1.1 What is the AutoLink Single Phase Electronic Sectionalizer? The AutoLink Electronic Sectionalizer is a protection device that operates to isolate a permanent fault in the distribution line. It must be used together with an upstream recloser or substation breaker. The AutoLink is not a fuse tripping device, therefore it cannot be used as a protection device by itself. 1.2 What is the main function of the AutoLink? The main function of the AutoLink is to discriminate between permanent and transient faults in the distribution line, giving the possibility to clear transient faults without permanent interruption to the customers. 1.3 Does the AutoLink replace a fuse? The AutoLink fits into a standard fuse cutout and it directly replaces an existing fuse base. When it operates the AutoLink drops open like a fuse. 1.4 How does the AutoLink operate? The AutoLink senses a current above the pickup threshold and zero current when the upstream recloser or substation breaker operates. If the fault is temporary it would be cleared by the reclose operation and the AutoLink reclose counter resets. If the fault is permanent the AutoLink will trip on the last open of the recloser, clearing the permanent fault in its branch, allowing the recloser to close prior to going to lockout. 1.5 How many reclose operations can the AutoLink see? The AutoLink is user settable to detect 1 to 4 opening operations of the recloser. 1.6 What are the available pickup levels in the AutoLink? The AutoLink is user settable to detect fault currents from 6A to 215A at 16 preset levels. Typical fuses have a current rating of up to 200A. 1.7 When does the AutoLink reset its counter? The AutoLink reset time is 30 sec and it starts counting from each pickup or dead line detection condition. 1.8 What is the shortest open time? The AutoLink minimum dead line detection time is 80 msec. If the dead line detection time is less than 80 msec, then the AutoLink will not advance its counter. For the AutoLink to operate it needs a minimum open time (reclose timer) of 500 msec. The 500 msec time is needed for the AutoLink to drop in the open position. 4

Rev. 3 October 2013 Page 5 of 8 1.9 What is the longest open time? The dead line condition (recloser open time) should be no longer than 3.5 minutes, for the AutoLink to have enough stored energy to trip. 1.10 How many models of AutoLink are available? There are 3 models of AutoLink: 15kV, 27kV and 33kV. These 3 models have 3 different tube lengths, with exactly the same components to fit the respective standard cutout. 1.11 Where is the manufacturing located? Manufacturing is at the ABB Argentina Medium Voltage Factory. 1.12 Where do I get support for the AutoLink? AutoLink support for USA and Canada is available from ABB in Lake Mary, FL. ABB Inc. 655 Century Point Lake Mary, FL 32746 Phone: +1 407-732-2000 ext. 2510 +1 800-929-7947 ext. 5 Fax: +1 407-732-2029 email: customer.service.group@us.abb.com www.abb.com/mediumvoltage 2 Technical features 2.1 What standard does the AutoLink comply with? The AutoLink complies with ANSI C37.63 standard (IEEE Standard Requirements for Overhead, Pad- Mounted, Dry-Vault, and Submersible Automatic Line Sectionalizers for AC Systems up to 38kV). 2.2 What is the maximum pass-through current for the AutoLink? The AutoLink is suitable for carry 4kA / 1 sec of short-circuit current and 10kA peak. 2.3 What type of faults does the AutoLink detect? The AutoLink doesn t have curves. It detects any type of faults as long as the fault current exceeds the AutoLink pickup setting for half a cycle or longer. 2.4 What is the AutoLink life-span? According to the ANSI C37.63 standard, the mechanical life must meet 200 operations and the AutoLink has been certified for 200 operations, as stated in the relative type test report. 5

Rev. 3 October 2013 Page 6 of 8 2.5 Can the AutoLink be bench tested? The AutoLink can be bench tested and a procedure is available for this purpose. 2.6 Does the AutoLink measure voltage? The AutoLink doesn t have any voltage measuring or sensing, it measures current and uses it to power up. 2.7 When does the AutoLink know that the line is open? The AutoLink detects a dead line when it measures 200mA or less. If more than 200mA are present when the current is interrupted, the AutoLink will not advance its counter. 2.8 Does the AutoLink detect transformer energization inrush currents? The AutoLink detects and discriminates inrush currents thanks to a 2 nd harmonic restraint algorithm. This allows the AutoLink not to pick up upon an inrush current in the distribution line and also being coordinated with the upstream recloser for this functionality. 2.9 What is the AutoLink Ingress Protection rating? The AutoLink has been tested and rated to IP65. 3 Installation and Operation 3.1 Which cutout bodies are suitable for AutoLink installation? AutoLink fits on ABB ICX, AB Chance, Delmar, Cooper, S&C, Lorenzetti and Delmar. For other brands, we recommend to send the cutout body to the factory, where the AutoLink can be tested in order to verify its mechanical operation. 3.2 What is the minimum load current required for the AutoLink to be operational? The AutoLink requires 6A for at least 30 sec to charge up. A larger current will shorten the charge up time. 3.3 Are there spare parts available for the AutoLink? Since AutoLink is a sealed device, there are no spare parts required for maintenance purposes, therefore the only components that may be replaced are the upper cap, O-ring, silicone grease, current and count labels. 6

Rev. 3 October 2013 Page 7 of 8 3.4 Can the AutoLink be opened under load? The AutoLink is not a fault-operation device. It doesn t have an arcing chamber or an extinguishing medium to prevent electrical arcing, therefore it is not designed or safe for the operator to open it under load. A load buster tool may be used to open the AutoLink under load. The Load Break AutoLink provides an arcing chamber which allows safe load breaking with a standard hot stick. 3.5 Can the AutoLink be closed in an energized line? The AutoLink is not a fault-operation device. It doesn t have an arcing chamber or an extinguishing medium to prevent electrical arcing, therefore it is not designed or safe for the operator to close it in an energized line. The ANSI C37.63 standard has no recommendations regarding closing in live line conditions and therefore there are no tests or safe practices defined. While a common practice in utilities is to close a fused cutout or an AutoLink in live line conditions, there is no way to run a test and certify that the closing operation can be done since the possibilities of speed, operator force, hot stick and environmental conditions vary from case to case. ABB does not recommend to close the AutoLink in live line conditions as there is no protection for the operator and there is a possibility to be closing into a fault. The user should follow safe practices which do not put the operator at risk. The arc chamber of the Load Break AutoLink was only designed for opening under load conditions and not for closing into a live line. 3.6 What are the recommendations for setting the AutoLink? There are two settings for each model of the AutoLink: current and count setting. The current setting should be at least 10% below the pickup current of the upstream recloser or substation breaker to ensure that AutoLink will see the fault. The count setting should be one count less than the upstream recloser or substation breaker to isolate a permanent fault downstream from the AutoLink preventing the recloser from going to lockout. 3.7 How does the AutoLink trip? The AutoLink is equipped with an electronic control and a mechanical tripping mechanism. By means of the current sensing the electronics determines when the AutoLink should trip. When this happens the tripping mechanism operates and releases a lever that unlocks the AutoLink from its cutout and it falls by gravity, having its pivot in the lower contact. The AutoLink remains hanging in the cutout by means of its lower contact. This gives visual confirmation of the opening of the MV circuit. 3.8 How do I reset the AutoLink after a trip? The AutoLink is field resettable. To reset the AutoLink please follow the instructions given in the manual. No special tool are needed for resetting the AutoLink. A hot stick is needed to reach the AutoLink in its cutout. 7

Rev. 3 October 2013 Page 8 of 8 4 General 4.1 Does AutoLink improve quality measures and costs? The AutoLink improves SAIDI and SAIFI indexes and costs as it facilitates clearing of transient faults without permanent interruption to the customers. In a distribution line, 80% of the faults are transient and 20% are permanent. Using AutoLink the only faults that remains with permanent interruption to the customers are the permanent ones (only 20% of the total faults). It also increases revenue of energy as there is no interruption on temporary faults and decreases the operational costs for dispatching crews to reset fuses. 4.2 Can the AutoLink work in 3-phase mode? The 3-Phase AutoLink is equipped with a mechanical interlock that ensures 3-phase operation. This application is commonly used in networks with MV motors that require a secure opening when there is a single phase fault and the 2-phase supply to the motor should be avoided as it could damage it. 8