Sarnafil TS E. Polymeric membrane for roof waterproofing. Product Description

Similar documents
Polymeric membrane for roof waterproofing. Uses Roof waterproofing membrane for exposed flat roofs: Loose laid and mechanically fastened

SYSTEM DATA SHEET Sikafloor Pronto RB-58

SYSTEM DATA SHEET Sikafloor Pronto RB-55

Socar New Management Office Project. Baku, AZERBAIJAN m2 ExtruBit D ECB Geomembrane

PRODUCT DATA SHEET SikaCor HM Mastic

Construction. High-performance, 2-part epoxy anchoring adhesive. Product Description. Tests. Product Data Sheet Edition _1

PRODUCT DATA SHEET Sikafloor -359 N

Good crack bridging ability Mechanically resistant if broadcast Watertight Easy application Solvent free

2-part PUR highly elastic, crack-bridging coating. Sikafloor -350 N Elastic is a two part, solvent free, highly elastic polyurethane resin.

Construction. Pultruded Carbon Fibre Plates for Structural Strengthening As Part of a Sika CarboDur System. System Description

Pultruded carbon fibre plates for structural strengthening as part of a Sika CarboDur system

Construction. Product description:

PSI Anti-Corrosion Tape

PRODUCT DATA SHEET SikaCor Elastomastic TF

Brown pigment - High Performance, special with high thermal stability

Neopolen P 9230 ESD. Bulk density 1) Average Average Color 2) particle size particle weight [ kg/m 3 ] [ mm ] [ mg ]

Delivery program ROOFING AND WATERPROOFING SYNTHETIC MEMBRANES MAPEPLAN PVC-P MAPEPLAN T FPO/TPO

Dual Lock Reclosable Fasteners Roll Goods with Pressure Sensitive Adhesive

Geomembrane Test Methods

Range of single layer waterproofing membranes for roofs, façades and buildings

Surface Protective Systems

Product Information. Bayferrox 610. Description. Specification. Specification. Brown pigment

Product Information. Bayferrox 640. Description. Specification. Brown pigment

NEW: RAUFILAM -E COLOUR ALWAYS THE RIGHT CHOICE. Industrial hoses, with and without fabric lining

Standard Elastomeric Bearings

Product Information. Description. Specification

EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES

Black pigment - High Performance micronised. Synthetic iron oxide Fe 3 O 4 Pigment black 11 (77499)

Synthetic iron oxide α - Fe 2 O 3 Pigment red 101 (77491)

Accessory Fitting Instructions

Product information. COLORTHERM Red 110 M. Description. Specification. Specification. Red pigment

Surface Protective Systems

Product information. COLORTHERM Yellow 30. Description. Specification. Specification. Yellow pigment

PUR c-track cables For highest requirements

RockLap H&V Pipe Sections

protect mask conduct reflect enhance 3M Specialty Tape Solutions

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

SOLON SOLbond Integra. The Innovative Solar Rooftop System.

NEW: quality. DuoSolar. DuoSolar. ARMAFLEX DUOSOLAR the easy-to-install pre-insulated tubing system for reducing the energy loss.

Data sheet chainflex CFSOFT1

Surface Protective Systems

Designed to prevent condensation and energy losses

PUR-O-STOP FS-L. General Building Inspectorate Approval for curtain grouting CE-marking in accordance with EN

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

EUROPLEX SDX EUROPLEX SDX-F. Danger averted! Static dissipative ESD glazing made of polycarbonate

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

BOAX-B Mat E. Type Series Booklet

EFFICIENCY IN SOLAR APPLICATIONS

20 HUBER+SUHNER RADOX SOLAR

HST -LS Interlocking device (Translation of Original Manual)

TuffTrak. Heavy Duty Road Mat

PTV TECHNICAL PRESCRIPTIONS. ELASTOMERIC SEALS: Part 1: Vulcanized Rubber FOR. Impartial institute for the monitoring of construction products

AIR RESERVOIRS. Product Catalogue

Assembly instructions

ventilation for mines and tunnels The art of transporting fresh air into mines

MITRAS MATERIALS GMBH

MasterProtect 1870 / 1880

Safety Shock Absorbers SCS33 to SCS64

Evacuated tube collectors

NOVELIS OHLER Flexrohre For safety, comfort and flexibility...

SIGMAGUARD CSF 660. PRODUCT DATA SHEET December 12, 2014 (Revision of April 1, 2009) DESCRIPTION

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

Bostik Intucrylic Sealant INTUMESCENT ACRYLIC JOINT SEALANT

3M XYZ / Isotropic Electrically Conductive Adhesive Transfer Tape 9709S / 9709 SL

Multi-Circuit Rotary Block

Elastollan Product Range

Centrifugal fan with highly efficient EC drive motor

3M Electrical Tapes Product Selection Guide. Insulate & Protect. with Quality Tapes. Preliminary

Angle seat valve with diaphragm actuator VZXA-...-M

Gavita HortiStar 1000 DE EU/US

Product information. cuturon. neobond pretex

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

SAFET Y PRODUCTS. TT-Series Safety Edge Product Manual

CM3-E Operation Manual DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter

RECYCLABILITY EVALUATION PROTOCOL FOR PE FILMS

ANSI/AGRSS Automotive Glass Replacement Safety Standard

TuffTrak. Heavy Duty Road Mat. » Heavy Duty Road Mat» Incredibly Tough & Flexible» Unique Dual Grip Capability

Installation and Operating Instructions Magnetic Vibrator MR 1

Installation and operating instructions for elastic jaw coupling REK DCO. E e. Schaberweg Telephone

Installation Devices 4

Installation Manual. Opal Solar QSA Series

DRYER EXHAUST VENT FLASHINGS

Adjustable Speaker Mount GRAVIS 8

Adjustable Speaker Mount GRAVIS 12

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

CV/LF and CV/CF. TICO Structural Bearings

VALSIR SUPPLY SYSTEMS MIXAL

Power consumption In operation At rest For wire sizing

There is Merbenit in there. Your industry product.

NOVAGUARD 890. PRODUCT DATA SHEET January 21, 2015 (Revision of December 12, 2014) DESCRIPTION

n-butyric Anhydride n-butanoic acid anhydride CAS no EC no

Data sheet chainflex CF5

c-go 24V/6A 24V/8A 24V/12A

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

Spaceloft Insulation TECHNICAL GUIDE

BALLASTED ROOFING SYSTEMS COST EFFICIENT RECYCLABLE SUSTAINABLE

Neopolen. Contents. 1. Product 1.1 Description 1.2 Forms supplied 1.3 Delivery, Conveying, Storage

3M Electrical Markets Division. Rubber, Mastic and Specialty Tapes Application Guide. Choose the. Right Tape. for your. Electrical Project

MANUAL. Single charger

THE PRE-INSULATED COPPER PIPES FOR DURABLE AND EASY CONNECTION OF AIR CONDITIONING UNITS

Transcription:

Roofing Product Data Sheet Edition 06.2013 Version no. 01 Sarnafil TS 77-18 E Polymeric membrane for roof waterproofing Product Description Sarnafil TS 77-18 E8 E (thickness 1.8 mm) is a Polyester reinforced, multi-layer, synthetic roof waterproofing sheet based on premium-quality flexible polyolefins (FPO) containing ultraviolet light stabilizers, flame retardant and an inlay of glass non-woven. (DE/E1 FPO-BV-V-PG-GV-1,8) Sarnafil TS 77-18 E E is a hot air weldable roof membrane formulated for direct exposure and designed to use in all global climatic conditions. Sarnafil TS 77-18 E8 E is produced with an inlay of glass non-woven for dimensional stability and a polyester reinforcement for high strength. Sarnafil TS 77-18 E8 E is provided for mechanically attached roof systems. Sarnafil TS 77-18 E8 E has no built-in stress at the time of production and has a fully encapsulated carrier with no risk to delamination or water-wicking. The dimensional stability of Sarnafil TS 77-18 E8 E is excellent. Roofing Uses Characteristics / Advantages Waterproofing membrane for: Mechanically fastened roofs, primarily with roof pitch >20 and for fire protection Outstanding resistance to weathering, including permanent UV irradiation High resistance to aging Excellent flexibility in cold temperatures No built-in stress at the time of production High dimensional stability High resistance to hailstorm High resistance to impact load High maximum tensile load Excellent weldability No risk of delamination or water-wicking Compatible to old bitumen Resistant to common environmental influences Recyclable Approval / Standards Polymeric sheets for roof waterproofing according to EN 13956, certified by notified body 1213-CPD-3915 and provided with the CE-mark. DIN V 20000-201 DIN 18531-2 Reaction to fire according to EN 13501-1, class E External fire performance tested according to ENV 1187 and classified according to EN 13501-5: BROOF (t1) Resistance to flying sparks and radiating heat according to DIN 4102/part 7 Official Quality Approvals and Agreement Certificates and approvals. Monitoring and assessment by approved laboratories. Quality Management system in accordance with DIN EN ISO 9001 Sarnafil TS 77-18 E8 1/5

Appearance / Colours Surface: matt Colours: Top surface: beige grey (nearest RAL 7040) Bottom surface: black Packaging Sarnafil TS 77-18 E8 standard rolls are wrapped individually in a blue PE-foil. Packing unit: 21 standard rolls per pallet Storage Conditions / Shelf-Life Roll length: Roll width: Roll weight: 15 m 2.00 m 64.80 kg Rolls must be stored in a horizontal position on pallet and protected from direct sunlight, rain and snow. Product does not expire if correctly stored. Do not stack pallets of rolls during transport or storage. Technical Data Product Declaration DIN EN 13956/ DIN V 20000-201 Visible defects Pass DIN EN 1850-2 Length 15 (-0 / +5 %) m DIN EN 1848-2 Width 2.00 (-0,5 / +1 %) m DIN EN 1848-2 Straightness 30 mm DIN EN 1848-2 Flatness 10 mm DIN EN 1848-2 Effective thickness 1.80 (-5 / + 10 %) mm DIN EN 1849-2 Mass per unit area 2.16 (-5 / + 10 %) kg/m² DIN EN 1849-2 Water tightness Pass DIN EN 1928 Water tightness 400 kpa / 72 h DIN V 20000-201 / DIN EN 1928 Effects of liquid DIN EN 1847 chemicals, including water External fire performance Part 1-4 (for roof structures proofed by Sika) Resistance to flying sparks and radiating heat (for roof structures proofed by Sika) Reaction to fire On request BROOF(t1) 20 DIN ENV 1187 DIN EN 13501-5 Fulfilled for roof pitch 20, > 20 DIN V ENV 1187, DIN 4102-7 Class E EN ISO 11925-2, classification to DIN EN 13501-1 Hail resistance DIN EN 13583 rigid substrate flexible substrate 25 m/s 33 m/s Joint peel resistance 300 N/50 mm DIN EN 12316-2 Joint shear resistance 500 N/50 mm DIN EN 12317-2 Joint shear resistance tear outside the weld joint DIN V 20000-201 / DIN EN 12317-2 Sarnafil TS 77-18 E8 2/5

Water vapour transmission properties = 200 000 (±30%) DIN EN 1931 Tensile strength DIN EN 12311-2 longitudinal (md) 1) 900 N/50 mm transversal (cmd) 2) 800 N/50 mm Elongation DIN EN 12311-2 longitudinal (md) 1) 12 % transversal (cmd) 2) 12 % Resistance to impact EN 12691 hard substrate 700 mm Method A soft substrate 1000 mm Method B Resistance to static load DIN EN 12730 rigid substrate 20 kg Method A soft substrate 20 kg Method B Tear strength DIN EN 12310-2 longitudinal (md) 1) 300 N transversal (cmd) 2) 300 N Dimension stability DIN EN 1107-2 longitudinal (md) 1) 0,2 % transversal (cmd) 2) 0,1 % Foldability at low temperature -20 C EN 495-5 UV exposure Pass (> 5000 h) DIN EN 1297 UV exposure DIN V 20000-201 Grade 0 DIN EN 1297 Exposure to bitumen 3) Pass DIN EN 1548 Exposure to bitumen Technique (b) 1) md = machine direction 2) cmd = cross machine direction 3) Sarnafil T is compatible to old bitumen DIN V 20000-201 DIN EN 1548 Sarnafil TS 77-18 E8 3/5

System Information System Structure Wide range of accessories is available e.g. prefabricated parts, roof drains, scuppers and walkway pads. The following materials are strongly recommended: Sarnafil T 66-15 D Sheet for detailing Sarnafil TS 77-E strips Sarnafil T Metal Sheet Sarnabar Sarnafil T Welding Cord Sarnafil T Prep / Sarnafil T Wet Task Set Sarnacol T 660 (contact adhesive) Solvent T 660 (deluter/ cleaner) Sarnafil T Clean Application Conditions / Limits Temperature Compatibility The use of Sarnafil TS 77-18 E membrane is limited to geographical locations with average monthly minimum temperatures of -50 C. Permanent ambient temperature during use is limited to +50 C. Sarnafil TS 77-18 E8 E may be installed on all thermal insulations and levelling layers suitable for roofing. No additional separation layer is required. Probably a fire protection layer is necessary. Sarnafil TS 77-18 E8 E is suitable for installation directly on top of existing, carefully cleaned, levelled bituminous roofing, e.g. re-roofing over old flat roofs. Colour changes in membrane surface may occur in case of direct contact with bitumen. In case of existing roof build up needs to be removed, Sarnafil TS 77-18 E8 E can be adhered directly on to the bituminous vapour control layer for partitioning and protection of the day work. Processing Installation / Tools Conditions See current install-instruction, which you can request at Sika Installation works to be carried out only by Sika instructed contractors for roofing. Sarnafil TS 77-18 E8 4/5

Value Base All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Local Restrictions Please note that as a result of specific local regulations the performance of this product may vary from country to country. Please consult the local Product Data Sheet for the exact description of the application fields. Ecology, Health and Safety Information REACH A Safety Data Sheet following EU-Regulation is not needed to bring the product to the market, to transport or to use it. The product does not damage the environment when used as specified. European Community Regulation on chemicals and their safe use (REACH 1 : EC 1907/2006) This product is an article within the meaning of Regulation (EC) No 1907/2006 (REACH). It contains no substances which are intended to be released from the article under normal or reasonably foreseeable conditions of use. Therefore, there are no registration requirements for substances in articles within the meaning of Article 7.1 of the Regulation. Based on our current knowledge, this product does not contain SVHC 2 from the candidate list published by the European Chemicals Agency in concentrations above 0.1 % (w/w). 1 = Registration, Evaluation, Authorisation and Restriction of Chemicals 2 = Substances of very high concern Roofing Protective Measures Transportation Class Disposal Fresh air ventilation must be ensured, when working (welding) in closed rooms. Local safety regulations must be observed. The product is not classified as hazardous good for transport. The material is recyclable. Disposal must be according to local regulations. There is the possibility to attend to the take-back-system ROOFCOLLECT. Please contact ISD INTERSEROH Entsorgungsdienstleistungs GmbH Tel.: (02203) 9147-1366 Legal note: The information, and, in particular, the recommendations relating to the application and enduse of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Sika Deutschland GmbH Telefon +49 711 8009 0 Kornwestheimer Straße 103-107 Telefax +49 711 8009 321 70439 Stuttgart www.sika.de Sarnafil TS 77-18 E8 5/5