Oil Pump Models L 5016, L 5116 & L 5132

Similar documents
STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

S T O P. Oil Pump. Models L 5016, L 5116 and L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

G8 Portable Fuel Transfer Pump Owner s Manual

STOP. M-3130 & M-3130-RDP Series. 115/230 Volt Super Duty Fuel Pumps. Owner s Manual. M-3130-PO Pump Only DO NOT RETURN THIS PRODUCT TO THE STORE!

ILLUSTRATED PARTS LIST

M-3130 & M-3130-RDP Series 115/230 Volt Super Duty Fuel Pump M-3130-ML Manual Nozzle M-3130-AL Automatic Nozzle M-3130-PO Pump Only Owner s Manual

M-3020 STOP. Owner s Manual SAVE THESE INSTRUCTIONS TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE!

STOP. LP-50DEF-BRL Lever Hand Pump System Barrel Mounting. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS

Product Owner s Manual. 8 GPM / 30 LPM, 12-volt Fuel Transfer Pump. Model G8P

M-3020 FUEL PUMP OWNER S MANUAL TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact. Great Plains Industries, Inc.

STOP. Contractor Special Fuel Pumps. Heavy Duty Fuel Pumps. Use this manual with: M-3425CS 24-Volt DC. M Volt DC & M Volt DC

STOP. M-150S-Methanol Pump Owner s Manual SAVE THESE INSTRUCTIONS DO NOT RETURN THIS PRODUCT TO THE STORE! TABLE OF CONTENTS

M-1115S Series Fuel Pump

M-150S, M-180S. and M-240S Fuel Pump. Owner s Manual SAVE THESE INSTRUCTIONS TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE!

M-3025CB-AV Fuel Pump

EZ-8 & EZ-8 METHANOL FUEL PUMP

P-200 Plastic Utility Pump for Petroleum Products

MR 5-30 Aviation Fuel Meter Owner s Manual

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

M-150S, M-180S & M-240S FUEL PUMP

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

M-1115S Series Fuel Pump

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

OWNER'S MANUAL SAVE THESE INSTRUCTIONS

VP12 High Viscosity Piston Pump

OWNER S TECHNICAL MANUAL OWNER S TECHNICAL MANUAL

QM Series Positive Displacement Fuel Meter

HP-100 Dual-Flo Petroleum Hand Pump

CM-3120 (115-volt, NPT, Gallon or Litre) CM-3220 (230-volt, NPT, Gallon) CM-3260 (230-volt, BSPT, Litre) Heavy Duty Cabinet Model Fuel Transfer System

MR 5-30-RD Remote Dispenser

FM-530-RD Remote Dispenser

PVDF TURBINE HOUSING

PVDF TURBINE HOUSING

TURBINE HOUSING. Commercial Grade. Owner s Manual Includes Aluminum and Nylon

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

LM-300 Lube Meter. Owner s Manual East 36th Street North Wichita, KS USA TEL: FAX: /10. Rev.

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

Pump System Technology. Owner's Manual SERIES LP PUMP. For series: LP50, LP200, LP450, LP650. Series LP50

QSI (Q-Star) Electronics Owner s Manual

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

FM-300H and FM-300HR Electronic Disc Meter Owner s Manual

TURBINE HOUSING. Industrial Grade. Owner s Manual. Includes Stainless Steel Housings with Tri-Clover Flange Fittings SAVE THESE INSTRUCTIONS

CM-3120 (115-volt, NPT, Gallon or Litre) CM-3220 (230-volt, NPT, Gallon) CM-3260 (230-volt, BSPT, Litre) Heavy Duty Cabinet Model Fuel Transfer System

Positive Displacement Flowmeters GM007 series instruction manual

AUTOMATIC SUBMERSIBLE UTILITY PUMP

LM-300 Lube Meter. Owner s Manual East 36th Street North Wichita, KS USA TEL: FAX: /08. Rev.

SUBMERSIBLE SUMP PUMPS

ESE Series Cast Iron Sewage Pumps

Positive Displacement Flowmeters GM020 series instruction manual

TURBINE HOUSING. Owner s Manual Includes Aluminum, Brass and Stainless Steel Housings and ANSI Flange Fittings

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

SUBMERSIBLE SUMP PUMPS

Positive Displacement Flowmeters GM515 series instruction manual

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Turbine Housing. Owner s Manual Includes Aluminum, Brass and Stainless Steel Housings and ANSI Flange Fittings

Water Jetter Units DU JT50 / DU JT100

Presoak & Tire/Engine Cleaner Systems (Air Pump) DU TC_A & DU PS_A

HALLMARK INDUSTRIES INC

LM-200 MECHANICAL LUBE METER Owner s Manual

PRE-PLUMBED SEWAGE SYSTEM

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

GARDEN HOSE UTILITY PUMP

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

SUNC3000 / Item #40885

TABLE OF CONTENTS GENERAL INFORMATION

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

StormPro BA Series Sump Pump

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

SUPER PUMP OUT SYSTEM

OWNER S MANUAL STOP. Models: Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

High Pressure Pump Units featuring CAT PUMPS DUPM550 & DUPM570

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

Wash Prep Systems featuring CAT PUMPS DUPM623 DUPM820 / DUPM820-TS DUPM820D / DUPM820D-TS DUPM1010. Owner s Manual #

SERIES 300V 115 and 230 VOLT AC FUEL TRANSFER PUMP Owner's Operation & Safety Manual Models FR300V, FR301V, FR310V & FR311V

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

IM SERIES BI-DIRECTIONAL INSERTION FLOWMETER. Instruction Manual. To the owner SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

Air-Operated 5:1 Oil Pump

Single Pump Station with Delay, 10HP/1PH DU PS2001C-PG

Operating Instructions & Parts Manual. Oil Control Gun. Models 48UJ82, 48UJ83, 48UJ84, 48UJ85 and 48UJ86

Garden Hose Reel with 3/4In. x 100Ft. Hose. Owner s Manual

Pressure Washer Hose Reel

Matala. VersiFlow Series. Instruction and Maintenance Manual

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

SAVE THESE INSTRUCTIONS

16 Inch Surface Cleaner

110 Volt/12 Volt Portable Inflator

MODEL 1385 & 1385-H Professional Rotary Drum Pump

Electric Diesel Pump EDP/12, EDP/24

Electric Fuel Pump FPM

12 Volt Heavy-Duty Air Inflator

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

60 Watt Industrial LED Low Bay Light

StormPro BCV400 Sewage Ejector Pump

Direct Fill Fuel System User s Manual

Transcription:

SAVE THIS OWNER S MANUAL Oil Pump Models L 5016, L 5116 & L 5132 Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact GPI before returning any product. If you are missing parts or experience problems with your installation, our Customer Support Department will be happy to assist you: 800-835-0113 or 316-686-7361 TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 2 Operation... 3 Maintenance... 3 Troubleshooting... 4 Viscosity Charts... 5 Illustrated Parts List... 6 Specifications... 7 Service... 7 Warranty... 8 To the owner... Congratulations on receiving your GPI oil pump. We are pleased to provide you with a system designed to give you maximum reliability and efficiency. Your pump is designed for use with motor oil, gear oil, hydraulic oil and waste oil. If used with antifreeze, do not exceed 50% water. Please take all due precautions when handling these liquids. Your safety is important to us. Also, to assure the longest possible service life, it is important that you follow the operation and maintenance procedures outlined in this manual. We are proud to provide you with a quality product and dedicated support. Together with your conscientious use, we are sure that you will obtain years of safe, dependable service. Victor Lukic, President Great Plains Industries, Inc. 03/14 922029-01D

GENERAL INFORMATION The purpose of this manual is to assist you in installing, operating and maintaining your GPI Oil Pump. This pump is a positive displacement, direct drive pump. Models L 5116 and L 5132 are wired for 115-volts only, however these motors have the capability to run on 230-volts if properly wired by an Electrician (see the label on the motor for specifications). GPI does not supply any wiring items or hookup connectors for the 230 voltage. Rewiring for 230-volts is the risk and responsibility of the buyer/owner and user. GPI is not liable for any damage or accidents caused by rewiring. Both the 12-volt DC and the 115-/230-volt AC pump are compatible with motor oil, gear oil, hydraulic oil, antifreeze (not to exceed 50% water), ATF and waste oil. Do not use this pump for dispensing any fluids other than those for which it was designed. To do so may damage pump components and will void the warranty. Do not use the GPI Oil pump with water, acids, brake fluid or windshield washer fluid. If in doubt about compatibility of a specific fluid, contact the supplier of the fluid to check for chemical compatibility with: Aluminum Stainless Steel Brass Steel Nitrile Rubber Zinc Plated Steel Do not leave the system running without fluids. Dry running can damage the pump. Do not pump the tank completely dry, as contaminants from the bottom of the tank may enter the pump. SAFETY INFORMATION The following safety alert symbols are used in this manual. It is your responsibility to: know and follow applicable national, state and local safety codes pertaining to installing and operating electrical equipment for use with petroleum fluids. ensure that all equipment operators have access to adequate instructions concerning safe operating and maintenance procedures. Observe all safety precautions concerning safe handling of petroleum fluids. Do not use pump with low flash point fluids (100 F or less). To ensure safe operation, this pump must be properly grounded. Care should be taken to ensure proper grounding during initial installation and after any service or repair procedures. For your safety, please take a moment to review the warnings below. Observe precautions against electrical shock when operating the system. Serious or fatal shock can result from operating electrical equipment in damp or wet locations. On 12-volt pumps, inspect external pump wiring regularly to make sure it is correctly attached to the battery. To avoid electrical shock, use extra care when connecting the pump to power. Avoid prolonged skin contact with petroleum fluids. Use protective goggles, gloves and aprons in case of splashing or spills. Change saturated clothing and wash skin promptly with soap and water. Observe precautions against electrical shock when servicing the pump. Always disconnect power before repairing or servicing. Never apply electrical power to the system when any of the coverplates are removed. If using solvent to clean pump components or tank, observe the solvent manufacturer s recommendations for safe use and disposal. The 115-/230-volt AC pump motors are equipped with thermal overload protection. If overheated, the pump will shut itself off. Turn off the pump if this occurs. See Motor Protector Section for details. Worn and damaged hoses or nozzles are potential safety hazards and should be replaced. INSTALLATION DANGER WARNING CAUTION DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Make sure all threaded connections are wrapped with three to four turns of oil resistant thread tape or pipe thread sealant. Make sure drums are properly secured to prevent tip over when full or empty. All tanks must be properly vented. Installing Pump to a Tank GPI pumps have a 2-inch NPT connection that can be mounted directly to a 2-inch female pipe thread on the tank. 1. Clean the tank interior of all dirt and foreign material. 2. Glue sections of suction pipe together and cut it to the proper length that is required. Suction pipe should extend 2 to 3 inches above bottom of tank. 3. Screw suction pipe into inlet threads of pump base. 2 Oil Pumps: L5016, L5116 & L5132 922029-01D

4. Insert the suction pipe through the tank bung. Screw pump into tank bung to secure the pump to the tank. (Figure 1) FIGURE 1 12-volt DC Powered Pumps (Model L 5016): This GPI Oil Pump is factory wired for 12-volt DC. Circuit must be protected with a 50 amp automotive-type fuse (not supplied). The power cord is not supplied with the pump. GPI recommends a minimum power cord of 10/3 AWG. Do not exceed 15 feet of cord. GPI OPERATION CAUTION Do not operate pump dry. Damage to pump could occur. 5. To prevent pressure buildup and possible leaks through the ball valve, make sure the tank is vented. Installing Discharge Plumbing on Pump Outlet 1. Install a 90 degree elbow to the pump outlet using oil resistant pipe sealant. 2. Install the hose and ball valve using oil resistant pipe sealant on the threads. Tighten securely. Electrical Installation WARNING Electrical wiring must be done by a licensed electrician. Shut off all power before connecting wires to motor. Failure to follow these wiring instructions may result in death or serious injury from shock, fire or explosion. 115-/230-volt AC Powered Pumps (Models L 5116 & L 5132): This GPI Oil Pump is factory wired for 115-volt AC. These motors have the capability to run on 230-volts if properly wired by an electrician. Power to the unit should be supplied from a dedicated circuit breaker. If AC extension cords are used, they must be capable of safely carrying the rated motor current. Use only heavy duty, 3-wire, grounded extension cords. NOTE: Many building codes require Ground Fault Circuit interrupt (GFCI) protection. Motor Ratings (FLA): 115-/230-volt AC: 1/2 HP, 1725 RPM 7.5/3.7 amps 1 HP, 3450 RPM 13/6.4 amps 12-volt DC: 1/2 HP, 1800 RPM 40 amps Before first usage, pour oil into pump outlet port to coat pumping element. 1. Place ball valve into the receiving tank to be filled. 2. Turn on the motor. 3. Open the ball valve and fill the container to the desired level. If flow does not occur within 15 seconds, shut off motor and refer to the priming information in the Troubleshooting Section. 4. Shut off the nozzle. 5. Turn off the motor. Motor Protector The AC pumps contain thermal motor protection. If the pump overheats the unit will shutoff. If the motor shuts off, follow these instructions: Model L 5132: Turn off the switch. Allow the motor to cool before restarting. Model L 5116: Turn off the switch. Allow the motor to cool. Push the button to manually reset the protector. Model L 5016: The 12-volt model should be protected by an inline fuse (not supplied). If the motor shuts off, check the fuse. MAINTENANCE Disconnect power and relieve pressure in the system by opening the nozzle before servicing the pump. This pump is designed for minimum maintenance. Motor bearings are sealed and require no lubrication. Inspect the pump and components regularly for leaks and make sure the hose, ball valve and components are in good condition. Use of the pump with unauthorized fluids will void the warranty. Remove and clean the strainer if low flow is noticed. To clean the strainer, remove the three screws on the strainer cover. Remove cover and pull out screen. Clean screen and reinstall. Care should be taken not to damage the O-ring. Oil Pumps: L5016, L5116 & L5132 922029-01D 3

TROUBLESHOOTING SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION A. PUMP WON T PRIME 1. Dirty strainer screen Remove and clean strainer. 2. Suction line problem Check for leaks in suction line. 3. Pump outlet is blocked or valve is shutoff Check pump outlet system for blockage. 4. Fluid level below suction pipe Refill tank or add longer suction pipe. 5. Fluid viscosity exceeds pumps rated capability Refer to the Viscosity Charts for viscosity limits. 6. Gerotor is locked Inspect gerotor for smooth rotation. Remove any debris. 7. Excessive gerotor wear Inspect gerotor. Replace if worn. 8. Bypass valve not seating Remove / inspect bypass valve. Clean if necessary. B. LOW FLOWRATE 1. Dirty strainer screen Remove and clean strainer. 2. Suction line problem Check for leaks in suction line. 3. Fluid viscosity exceeds pumps rated capability 4. Nozzle or meter pressure exceeds product specifications Refer to the Viscosity Charts for viscosity limits. Replace meter or nozzle. 5. Bypass valve not seating Remove / inspect bypass valve. Clean if necessary. 6. Excessive gerotor wear Inspect gerotor. Replace if worn. 7. Low voltage to motor Ensure power at motor is at proper voltage. 8. Motor wired for incorrect voltage Rewire for correct voltage. Instructions are on motor nameplate. C. MOTOR STALLS WHEN VALVE/ NOZZLE IS CLOSED D. MOTOR STALLS WHEN PUMP FIRST STARTS E. MOTOR OVERHEATS 1. Bypass valve is sticking Remove / inspect bypass valve. Clean if necessary. 1. Fluid viscosity exceeds pumps rated capability Refer to the Viscosity Charts for viscosity limits. 2. Gerotor is locked Inspect gerotor for smooth rotation. Remove any debris. 1. Fluid viscosity exceeds pumps rated capability Refer to the Viscosity Charts for viscosity limits. 2. Gerotor is not rotating smoothly Inspect gerotor for smooth rotation. Remove any debris. 3. Incorrect voltage Ensure power at motor is at proper voltage. F. MOTOR WILL NOT TURN ON 1. No power to motor Check circuit breakers and electrical connections. 2. Switch failure Replace switch. 3. Motor has tripped internal motor protection Allow motor to cool for at least 30 minutes. G. PUMPS LEAK 1. Missing or damaged seals Inspect affected areas for proper O-ring sealing. 2. Shaft seal damage Inspect and replace shaft seal if needed. 3. Incompatible fluid pumped Check if fluid is compatible with aluminum, brass, nitrile rubber, stainless steel, steel and zinc plated steel. 4 Oil Pumps: L5016, L5116 & L5132 922029-01D

VISCOSITY CHARTS Oil Pumps: L5016, L5116 & L5132 922029-01D 5

ILLUSTRATED PARTS LIST GPI Item No. No. Part No. Description Req d. 1 110264-1 Suction Pipe Assembly... 1 2 110264-2 Suction Pipe Assembly... 1 3 110187-09 Hose Assembly... 1 4 142001-01 Gerotor Housing Adapter... 1 5 142002-01 Pump Body... 1 6 142021-01 Poppet Assembly... 1 7 142500-01 Gerotor Kit (Element & O-Ring)... 1 8 142005-01 Bypass Spring... 1 9 142008-01 Inlet Screen... 1 10 142009-01 Base Cover... 1 11 142014-01 Motor, 115-/230-volt AC, 1/2 HP, 1725 RPM... 1 12 142015-01 Motor, 115-/230-volt AC, 1 HP, 3450 RPM... 1 13 142016-01 Motor, 12-volt DC, 1/2 HP, 1800 RPM... 1 14 142022-01 Inlet Base Assembly... 1 15 142023-01 Poppet Plug Assembly... 1 16 90100389 O-Ring... 1 17 90100387 O-Ring, Nitrile... 1 18 90100388 O-Ring, Nitrile... 1 19 904002-24 Sems Screw & Washer Assembly... 4 20 904005-59 Spring Pin... 2 21 90400807 Sems Hex Head, 3/8"-16 x 3/4"... 4 22 90400793 Hex Head Screw, 5/16"-18 x 1-3/4"... 4 23 90400794 Sems Hex Head, 1/4"-20 x 1/2"... 3 24 90400795 Radial Lip Seal... 1 25 90600658 Ball Valve with 45 Spout... 1 6 Oil Pumps: L5016, L5116 & L5132 922029-01D

SPECIFICATIONS L 5016 L 5116 L 5132 Model: 12-volt DC Pump 115-volt AC 1/2 HP 115-volt AC 1 HP Pump Housing: Aluminum Aluminum Aluminum Performance: Pump Rate: 16 QPM (15 LPM) 16 QPM (15 LPM) 32 QPM (30 LPM) Duty Cycle: 30 min. ON, 30 min. OFF 30 min. ON, 30 min. OFF 30 min. ON, 30 min. OFF Max. Viscosity Pumped: 390 CPS 1160 CPS 970 CPS Operating Temperature: Maximum temperature is +140 F (+60 C). See Viscosity Chart for minimum temperature. Operating Pressure: 50 PSI Electrical Specifications: Input: 12-volt DC 115-/230-volt AC 115-/230-volt AC Current Draw: 40 amps 7.5/ 3.7 amps 13/ 6.5 amps Motor: 1800 RPM 1725 RPM 3450 RPM Motor Approval: UL Recognized Component, CSA Certified UL Recognized Component, CSA Certified UL Recognized Component, CSA Certified Motor Protection: Inline Fuse (not supplied) Thermal Protection Thermal Protection Cord: Min. 10/3 x 15 ft. (not supplied) 36 in. with Grounded NEMA Plug 36 in. with Grounded NEMA Plug Mechanical Connections: Bung: 2-inch NPT 2-inch NPT 2-inch NPT Inlet: 1-inch NPT 1-inch NPT 1-inch NPT Outlet: 3/4-inch NPT 3/4-inch NPT 3/4-inch NPT Weight: 43.4 lbs. 33.7 lbs. 43.6 lbs SERVICE For warranty consideration, parts, or other service information, please contact your local distributor. If you need further assistance, contact the GPI Customer Service Department in Wichita, Kansas, during normal business hours. A toll free number is provided for your convenience. 1-800-835-0113 To obtain prompt, efficient service, always be prepared with the following information: 1. The model number of your pump. 2. The manufacturing date code of your pump. For warranty work, always be prepared with your original sales slip or other evidence of purchase date. Please contact GPI before returning any pump. It may be possible to diagnose the trouble and find a solution with a telephone call. GPI can also inform you of any special requirements you will need to follow for shipping. CAUTION Do not return the pump without authority from the Customer Service Department. Due to strict government regulations, GPI cannot accept pumps unless they have been drained and cleaned. SAVE THESE INSTRUCTIONS Oil Pumps: L5016, L5116 & L5132 922029-01D 7

Limited Warranty Policy Great Plains Industries, Inc. 5252 E. 36 th Street North, Wichita, KS USA 67220-3205, hereby provides a limited warranty against defects in material and workmanship on all products manufactured by Great Plains Industries, Inc. This product includes a 1 year warranty from date of purchase as evidenced by the original sales receipt. A 30 month warranty from product date of manufacture will apply in cases where the original sales receipt is not available. Reference product labeling for the warranty expiration date based on 30 months from date of manufacture. Manufacturer s sole obligation under the foregoing warranties will be limited to either, at Manufacturer s option, replacing or repairing defective Goods (subject to limitations hereinafter provided) or refunding the purchase price for such Goods theretofore paid by the Buyer, and Buyer s exclusive remedy for breach of any such warranties will be enforcement of such obligations of Manufacturer. The warranty shall extend to the purchaser of this product and to any person to whom such product is transferred during the warranty period. This warranty shall not apply if: A. the product has been altered or modified outside the warrantor s duly appointed representative; B. the product has been subjected to neglect, misuse, abuse or damage or has been installed or operated other than in accordance with the manufacturer s operating instructions. To make a claim against this warranty, contact the GPI Customer Service Department at 316-686-7361 or 800-835-0113. Or by mail at: Great Plains Industries, Inc. 5252 E. 36 th St. North Wichita, KS, USA 67220-3205 GPI will step you through a product troubleshooting process to determine appropriate corrective actions. GREAT PLAINS INDUSTRIES, INC., EXCLUDES LIABILITY UNDER THIS WARRANTY FOR DIRECT, INDIRECT, INCIDENTAL AND CONSEQUENTIAL DAMAGES INCURRED IN THE USE OR LOSS OF USE OF THE PRODUCT WARRANTED HEREUNDER. The company herewith expressly disclaims any warranty of merchantability or fitness for any particular purpose other than for which it was designed. This warranty gives you specific rights and you may also have other rights which vary from U.S. state to U.S. state. Note: In compliance with MAGNUSON MOSS CONSUMER WARRANTY ACT Part 702 (governs the resale availability of the warranty terms). UL Recognized Component 2014 Great Plains Industries, Inc. All Rights Reserved. Made in U.S.A. and The Proven Choice are trademarks, and GPI is a registered trademark of Great Plains Industries, Inc. 03/14 922029-01D