Ceraliquid CPS42/CPS42D/CPS43

Similar documents
Orbisint CPS12/CPS12D/CPS13

Ceraliquid CPS41 and CPS41D

Orbipore CPS91 and CPS91D

Orbisint CPS11 and CPS11D

Orbisint CPS11 and CPS11D

Technical Information

Technical Information Ceraliquid CPS41D and CPS41

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

Technical Information Cleanfit CPA472D

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

Flowfit CPA250. Technical Information. Flow assembly for ph and ORP sensors

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

Technical Information Cleanfit CPA871

ph-kompaktelektrodensystem sensopac CPA 320

Operating Instructions. Flowfit W CPA250. Flow assembly for ph/orp sensors. BA041C/07/en/

Unifit CPA442. Technical Information. Process assembly For installation of 120 mm sensors in food and beverage, biotechnology and chemical industries

Technical Information Cleanfit CPA875

Conductivity Measurement CLM 280

Technical Information Cleanfit CPA451

Operating Instructions Dipfit CPA111

Technical Information Cleanfit Control CYC25

Electromagnetic Flow Monitor magphant

Technical Information Liquiline System CAT810

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Rod probe 11375Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Level Limit Switch liquiphant FTL 365 / FTL 366

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

SITRANS P measuring instruments for pressure

SITRANS F M. Flow sensor MAG 1100 F 3/59

Operating Instructions Cleanfit CPA871

Flow Measurement SITRANS F M

Cleanfit P CPA474. Technical Information. Retractable plastic process assembly with ball valve for ph and ORP electrodes

JUMO tecline HD ph and JUMO tecline HD Rd

Dissolved Oxygen, ph, and Conductivity

OPTIFLUX 6000 Technical Datasheet

Reed sensor For bypass level indicators Model BLR

Operating Instructions Cleanfit CPA875

Flow Measurement SITRANS F M

Analysis ph / ORP. Characteristics System. Applications Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

Omnigrad TA20, TA21. Technical Information. Temperature Measuring Technology Terminal heads for mounting on thermowells of resistance thermometers

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

SIPAN 32 and 34. Controllers, Sensors and Accessories for ph, ORP, Conductivity and Dissolved Oxygen

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Conductivity Measuring Cells ConduMax W CLS 19

Pressure transducer DMU 01K Compact version

Signet DryLoc ph/orp Electrodes

Proline Promag 10H, 50H, 53H, 55H

Analysis ph / ORP. Applications. Characteristics. Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

Conductivity Sensors ConduMax W CLS 19

Signet DryLoc ph/orp Electrodes

Series 3730 Electropneumatic Positioner Type

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

General Specifications

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

Oxymax W COS31. Brief Operating Instructions. Dissolved oxygen sensor

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet

STEEMCO Flowmeter for Steam

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Kämmer Actuators Series 4 Pneumatic and Electropneumatic

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Metal tube variable area flowmeter for gases, liquids and steam

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Soliphant II FTM30(D/S)/31(D/S)/32(D/S)

GHMsilverline Handheld Instruments

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

POSITIONERS and Controls for Complete Valve Automation

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Type Electronic Limit Switch

STEEMCO-MAS Flowmeter for Steam

Digital ph transmitter

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Digital ph transmitter

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Rugged ph/redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

JUMO tecline H2O2 JUMO tecline PAA Sensor for hydrogen peroxide and peracetic acid

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

Level Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S)

Continuous level sensor NSK

Tubeskin thermocouple assembly Model TC59-V

Level Probes multicap T DC 12 TA multicap T DC 11/16/21/26 TAN/TAS

Combination ph/redox (ORP) Sensors

* * Rev. 9 01/18 Product Manual

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Combination ph/redox (ORP) Sensors

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Level Probe multicap DC 16

Magnetic Inductive Flowmeter EP / UMF2 (B)

Level Measurement Point level measurement - RF Capacitance switches

Level measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure

Tubeskin thermocouple assembly Model TC59-V

Transcription:

Technical Information Ceraliquid CPS/CPSD/CPS ORP electrodes, analog and digital with Memosens technology and reference electrode Each with ceramic diaphragm and liquid KCl electrolyte Application Media with very low conductivities or a high percentage of organic solvents or alcohols: Food industry Biotechnology Laboratory measurements Power plants 0 With ATEX, FM and CSA approval for application in hazardous areas Your benefits Liquid KCl electrolyte enabling use at very low conductivities Ceramic diaphragm with defined KCl flow Application under pressures of up to 0 bar / 5 psi with counter pressure Resistant to poisoning thanks to separate reference lead Suitable for CIP / SIP cleaning Three lengths available: 0, 5 and 5 mm /.7, 8.86 and 6.7 inches Further benefits offered by Memosens technology Maximum process safety through contactless inductive signal transmission Data safety through digital data transmission Easy handling due to storage of sensor-specific data Predictive maintenance possible thanks to registration of sensor load data approval for digital sensors pending TI7C/07/en/05.05 55589

Ceraliquid CPS / CPSD / CPS Function and system design Measuring principle General properties Important properties CPSD Redox measurement The redox potential is a unit of measurement for the state of equilibria between oxidising and reducing components of a medium. Redox potential is measured similarly to the ph value. A platinum or gold electrode is used instead of ph-sensitive membrane glass. Analog to the ph measurement, an integrated Ag/AgCl reference system is used as a reference electrode. Application at low conductivity Thanks to its liquid KCl electrolyte filling, the CPS can be applied at very low conductivities ( 5 µs/cm). Sterilisable The electrode can be used in applications with steam sterilisation (max. 0 C / 66 F). Durability The electrode can be applied under pressures of up to 0 bar /5 psi with counter pressure. Maximum process safety The inductive and non-contacting measured value transmission of Memosens guarantees maximum process safety and offers the following benefits: All problems caused by moisture are eliminated. The plug-in connection is free from corrosion. Measured value distortion from moisture is not possible. The plug-in system can even be connected under water. The transmitter is galvanically decoupled from the medium. The result: No more need to ask about "symmetrically high-impedance" or "unsymmetrical" or an impedance converter. EMC safety is guaranteed by screening measures for the digital measured value transmission. Data safety through digital data transfer The Memosens technology digitalizes the measured value in the sensor and transfers it to the transmitter via a contactless connection. The result: An automatic error message is generated if the sensor fails or the connection between sensor and transmitter is interrupted. The availability of the measuring point is dramatically increased by immediate error detection. The digital signals are suitable for application in hazardous areas; the integrated electronics are intrinsically safe. Easy handling Sensors with Memosens technology have integrated electronics that allow for saving calibration data and further information such as total hours of operation and operating hours at very high temperatures. When the sensor is mounted, the calibration data are automatically transferred to the transmitter and used to calculate the current redox potential. Storing the calibration data in the sensor allows for calibration and adjustment away from the measuring point. The result: The sensors can be calibrated unter optimum external conditions in the measuring lab. Wind and weather do neither affect the calibration quality nor the operator. The measuring point availability is dramatically increased by the quick and easy replacement of precalibrated sensors. The transmitter does not need to be installed close to the measuring point but can be placed in the control room. Maintenance intervals can be defined based on all stored sensor load and calibration data and predictive maintenance is possible. The sensor history can be documented on external data carriers and evaluation programs at any time. Thus, the current application of the sensors can be made to depend on their previous history. Communication with the transmitter Always connect the digital sensor to a digital transmitter with Memosens technology. Data transmission to an analog transmitter is not possible. Endress+Hauser

CAL ENDRESS+HAUSER LIQUISYS REL REL REL REL REL ALARM Ceraliquid CPS / CPSD / CPS Data storage of the CPSD Measuring system Digital sensors are able to store the following system data in the sensor. Manufacturing data Serial number Order code Date of manufacture Calibration data Calibration date Calibrated offset (operating mode "mv") % slope (operating mode "%") Number of calibrations Serial number of the transmitter used for the last calibration Application data Temperature application range Redox application range Date of first commissioning Operating hours These system data can be displayed with the Mycom S or the Liquiline M CM transmitter. A complete measuring system comprises: CPS or CPSD ORP electrode Transmitter, e.g. Liquisys M CPM/5 (with Memosens technology for CPSD) Special measuring cable, e.g. CPK9 or CYK Memosens data cable for CPSD Immersion, flow or retractable assembly, e.g. Unifit H CPA E Measuring system for redox measurement Unifit H CPA CPS or CPSD ORP electrode CPK9 special measuring cable (for electrodes with TOP68 plug-in head) / CYK0 for digital sensors Liquisys M CPM5 transmitter a000 Input Measured variables Redox potential Measuring range " Caution! -500... 500 mv Please note the process operating conditions. Endress+Hauser

Ceraliquid CPS / CPSD / CPS Installation instructions " Caution! Installation Do not install the electrode upside down. The inclination angle must be at least 5 from the horizontal. A smaller inclination angle is not permitted as such an inclination results in air cushion forming. This might impair the contact of reference and metal lead. Make sure that the assembly s threaded connection for the electrode is clean and well running before installing the electrode. Hand tighten the electrode ( Nm)! (Given value only applies to installation in Endress+Hauser assemblies.) Make sure to follow the installation instructions in the operating instructions of the used assembly. A 5 5 B Electrode installation; inclination angle min. 5 from the horizontal A Permitted inclination angle B Non-permitted inclination angle a000686 Ambient temperature " Caution! Environment Danger of frost damage Never use the electrode at temperatures below -5 C / 5 F. Storage temperature 0... 50 C /... F Ingress protection IP 67: GSA/SSA plug-in head (with closed plug-in system) IP 68: TOP68 plug-in head ( m /.8 ft water column, 50 C / F, 68 h) IP 68: Memosens plug-in head (0 m /.8 ft water column, 5 C / 77 F, 5 days, M KCl) Process Process temperature Process pressure Application CPS, CPS: -5... 0 C / 5... 66 F CPSD: -5... 5 C / 5... 75 F 0... 0 bar / 0... 5 psi with counter pressure via a separate KCl vessel CPS, CPSD: Reducing media, e.g. chromate reduction, chlorine dosing in swimming pools CPS: Single reference electrode, used in combination with the CPS6 single ph electrode Endress+Hauser

Ceraliquid CPS / CPSD / CPS KCl consumption 68 0 0 76 6 A 8 0 0 0 0 60 80 00 a000-en KCl consumption dependent on medium temperature A KCl consumption (ml/d) B Temperature ( C) C Temperature ( F) 800 mbar /.6 psi overpressure 00 mbar / 5.8 psi overpressure 00 mbar /.5 psi overpressure C B.5.9 5.8 8.7.6.5 6 A 8 0 00 00 00 600 800 000 B KCl consumption dependent on process pressure A KCl consumption (ml/d) B Overpressure to process (mbar) C Overpressure to process (psi) Medium temperature 80 C / 76 F Medium temperature 50 C / F Medium temperature 0 C / 68 F C a000-en Design, dimensions CPS Mechanical construction mm / inch 5. /.06 05 / 5.9 5 / 8.86 Ø 80 /.5 5 / 8.86 5 6 7 mm / inch 8 / 0.7 a00087-en Unifit H CPA with CPS with GSA plug-in head KCl reservoir Mounting device CPS (shaft length: 5 mm / 5.9") CPS with ESA plug-in head for CPA TOP68 plug-in head Pg.5 Viton O-ring with thrust collar KCl refilling Inner metal lead 5 Ag/AgCl lead for the reference 6 Liquid KCl electrolyte 7 Ceramic diaphragm 8 Platinum ring a00088-en Endress+Hauser 5

Ceraliquid CPS / CPSD / CPS mm/inch mm / inch 5 5 0 /.7 6 0 /.7 6 7 7 /0.7 8 / 0.7 8 CPS with SSA plug-in head SSA plug-in head, Pg.5 Hose connection for KCl refilling Viton O-ring with thrust collar Inner metal lead 5 Ag/AgCl lead for the reference 6 Liquid KCl electrolyte 7 Ceramic diaphragm 8 Platinum ring a00090-en CPS with ESS plug-in head ESS plug-in head, Pg.5 Hose connection for KCl refilling Viton O-ring with thrust collar Inner metal lead 5 Ag/AgCl lead for the reference 6 Liquid KCl electrolyte 7 Ceramic diaphragm 8 Platinum ring a00089-en Design, dimensions CPSD mm / inch 50 /.97 mm / inch 5 / 8.86 5 6 7 8 9 /0.7 0, 5, 5 /.7, 8.86, 6.7 5 6 7 8 9 / 0.7 CPSD with Memosens plug-in head Memosens plug-in head Viton O-ring with thrust collar KCl refilling Inner metal lead 5 Ag/AgCl lead for the reference 6 Liquid KCl electrolyte 7 NTC 0K temperature sensor 8 Ceramic diaphragm 9 Platinum ring a00077-en a00076-en CPSD with Memosens plug-in head and KCl connection Memosens plug-in head Hose connection for KCl refilling Viton O-ring with thrust collar Inner metal lead 5 Ag/AgCl lead for the reference 6 Liquid KCl electrolyte 7 NTC 0K temperature sensor 8 Ceramic diaphragm 9 Platinum ring 6 Endress+Hauser

Ceraliquid CPS / CPSD / CPS Design, dimensions CPS mm / inch 0 /.7 5 6 / 0.7 CPS with SSA plug-in head SSA plug-in head, Pg.5 Hose connection for KCl refilling Viton O-ring with thrust collar Ag/AgCl reference lead 5 Liquid KCl electrolyte 6 Ceramic diaphragm a0007-en CPS with ESS plug-in head ESS plug-in head, Pg.5 Hose connection for KCl refilling Viton O-ring with thrust collar Ag/AgCl reference lead 5 Liquid KCl electrolyte 6 Ceramic diaphragm a0007-en Weight 0. kg / 0. lb. Material Electrode shaft Redox measuring element Diaphragm process glass platinum ring ceramic diaphragm, sterilisable Process connection Pg.5 Plug-in heads Reference system CPS: ESA: threaded plug-in head Pg.5, TOP68, 6 bar / psi, Ex ESS: hose connection Pg.5, TOP 68, 0 bar / 5 psi, Ex GSA: threaded plug-in head Pg.5 SSA: hose connection Pg.5 CPSD-****A*: Memosens plug-in head for digital, contactless data transmission, 6 bar / psi, Ex and non-ex CPSD-****B*: Memosens plug-in head with hose connection for KCl refilling, for digital, contactless data transmission, 0 bar / 5 psi, Ex and non-ex Ag/AgCl metal lead with liquid KCl, M, AgCl free Endress+Hauser 7

Ceraliquid CPS / CPSD / CPS Certificates and approvals Ex approval CPS (ESA, ESS) ATEX II G EEX ia IIC T/T/T6 FM Class I Div., in combination with the Mypro CPM and Mycom S CPM5 transmitters Ex approval CPSD! Note! ATEX II G EEx ia IIC T/T/T6 FM a / CSA a I Div., in combination with the Liquiline M CM and Mycom S CPM5 transmitters Ex versions of digital sensors with Memosens technology are indicated by an orange-red ring in the plug-in head. Biocompatibility Biocompatibility validated according to: ISO 099-5:99 USP, current revision TÜV certificate TOP68 and Memosens plug-in heads Pressure resistance 6 bar, min. triple overpressure safety Electromagnetic compatibility of CPSD Interference emission and interference immunity complies with EN 66: 997 / A: 998 Ordering information Product structure CPS Electrode type 0 Standard version Measuring element PB Platinum ring Shaft length 0 mm /.7" (ESS and SSA plug-in heads only) 5 mm / 8.86" (ESA and GSA plug-in heads only) Plug-in head ESA Plug-in head Pg.5, TOP68, 6 bar / psi, Ex ESS Hose connection Pg.5, TOP68, 6 bar / psi, Ex GSA Plug-in head Pg.5 SSA Hose connection Pg.5 CPS- complete order code Product structure CPSD Version 0 Basic version, max. 5 C / 75 F Measuring element PB Platinum ring Shaft length 0 mm /.7" (versions with KCl hose connection only) 5 mm / 8.86" 6 5 mm / 6.7" (versions with KCl hose connection only) Electrolyte supply A Shaft hole KCl refilling, CPA B KCl hose connection, CPY7 Approval Non-hazardous areas G ATEX II G EEx ia IIC T/T/T6 CPSD- complete order code a) approval pending 8 Endress+Hauser

Ceraliquid CPS / CPSD / CPS Product structure CPS (for combination with single ph electrode CPS6) Electrode type 0 Standard version Reference type TB Liqid KCl Shaft length 0 mm /.7 Plug-in head ESS Hose connection Pg.5, TOP68, 6 bar / psi, Ex SSA Hose connection Pg.5 CPS- complete order code! Note! Accessories In the following sections, you find the accessories available at the time of issue of this documentation. For information on accessories that are not listed here, please contact your responsible service. Assemblies Cleanfit P CPA7 Compact retractable stainless steel assembly for installation in tanks and pipes, manual or pneumatic operation Ordering acc. to product structure, see Technical Information (TI7C/07/en) Cleanfit P CPA7 Compact retractable plastic assembly for installation in tanks or pipes, manual or pneumatic operation Ordering acc. to product structure, see Technical Information (TIC/07/en) Cleanfit P CPA7 Retractable stainless steel process assembly with ball valve for a particularly safe and reliable separation of the medium from the environment Ordering acc. to product structure, see Technical Information (TIC/07/en) Cleanfit P CPA7 Retractable plastic process assembly with ball valve for a particularly safe and reliable separation of the medium from the environment Ordering acc. to product structure, see Technical Information (TI5C/07/en) Cleanfit H CPA75 Retractable assembly for installation in tanks and pipes under sterile conditions Ordering acc. to product structure, see Technical Information (TI0C/07/en) Cleanfit P CPA7 or 7 a000009 Cleanfit P CPA7 or 7 a00000 Cleanfit H CPA75 a0000 Endress+Hauser 9

Ceraliquid CPS / CPSD / CPS Unifit H CPA Process assembly with integrated electrolyte vessel for installation of ph/orp electrodes Ordering acc. to product structure, see Technical Information (TI06C/07/en) Unifit H CPA Process assembly for the food industry, biotechnology and pharmaceutical industry, complies with EHEDG criteria and A standard 7-0 Ordering acc. to product structure, see Technical Information (TI06C/07/en) Dipfit W CPA Immersion and installation assembly for open and closed tanks Ordering acc. to product structure, see Technical Information (TIC/07/en) Unifit H CPA a0006 Unifit H CPA a0009 Dipfit P CPA0 Immersion assembly for ph/orp electrodes, for demanding processes Ordering acc. to product structure, see Technical Information (TI78C/07/en) Flowfit P CPA0 Flow assembly for ph/orp electrodes, for demanding processes Ordering acc. to product structure, see Technical Information (TI79C/07/en) Flowfit W CPA50 Flow assembly for ph/orp electrodes Ordering acc. to product structure, see Technical Information (TI0C/07/en) Dipfit W CPA a0000 Dipfit P CPA0 a000 Flowfit P CPA0 a000 Flowfit W CPA50 a000 0 Endress+Hauser

Ceraliquid CPS / CPSD / CPS Probfit H CPA65 Retractable assembly for installation in tanks and pipes under sterile conditions Ordering acc. to product structure, see Technical Information (TI6C/07/en) Ecofit CPA60 Process connection adapter and cable set for 0 mm /.7" ph/orp electrodes Ordering acc. to product structure, see Technical Information (TI6C/07/en) Probfit H CPA65 a0000 Ecofit CPA60 a0005 Electrolyte vessel Electrolyte solutions Buffer solutions Transmitters CPY7 electrolyte vessel Reservoir for KCl electrolyte, 50 ml / 0.0 US.gal Ordering acc. to product structure, see Operating Instructions (BA 8C/07/en) KCl-electrolyte solutions for liquid filled electrodes.0 mol, T = -0... 00 C (... F), 00 ml ( oz), order no. CPY-.0 mol, T = -0... 00 C (... F), 000 ml (0 oz), order no. CPY-.5 mol, T = -0... 00 C (-... 66 F), 00 ml ( oz), order no. CPY-.5 mol, T = -0... 00 C (-... 66 F), 000 ml (0 oz), order no. CPY- Technical buffer solutions for ORP electrodes +0 mv, ph 7.0, 00 ml (0.06 US gal.); order no. CPY-0 +68 mv, ph 0., 00 ml (0.06 US gal.); order no. CPY- Liquisys M CPM/5 Transmitter for ph and redox, field or panel-mounted housing, Hart or PROFIBUS available Ordering acc. to product structure, see Technical Information (TI9C/07/en) Mycom S CPM5 Transmitter for ph and redox, one or two channel version, Ex or Non-Ex, Hart or PROFIBUS available Ordering acc. to product structure, see Technical Information (TIC/07/en) Liquiline M CM Modular two-wire transmitter for Ex and non-ex areas Hart, PROFIBUS or FOUNDATION Fieldbus available Ordering acc. to product structure, see Technical Information (TI8C/07/en) Endress+Hauser

Measuring cables CPK9 special measuring cable For sensors with TOP68 plug-in head, for high-temperature and high-pressure applications, IP 68 Ordering acc. to product structure, see Technical Information (TI8C/07/en) CPK special measuring cable For ph/redox electrodes with GSA plug-in head Ordering acc. to product structure, see Technical Information (TI8C/07/en) CYK0 Memosens data cable For digital sensors with Memosens technology Ordering according to product structure, see below Certificates A Standard, non Ex G ATEX II G EEx ia IIC T6/T Cable length 0 Cable length: m / 9.8 ft 05 Cable length: 5 m / 6. ft 0 Cable length: 0 m /.8 ft 5 Cable length: 5 m / 9. ft 0 Cable length: 0 m / 65.6 ft 5 Cable length: 5 m / 8.0 ft 88... m length 89... ft length Ready-made Wire terminals! Note! CYK0- complete order code Ex versions of CYK0 are indicated by an orange-red coupling end. International Head Quarters Endress+Hauser GmbH+Co. KG Instruments International Colmarer Str. 6 79576 Weil am Rhein Deutschland Tel. +9 76 9 75 0 Fax+9769755 www.endress.com info@ii.endress.com TI7C/07/en/05.05 55589 Printed in Germany / FM+SGML 6.0 / DT