GE Energy. Variable Frequency Transformers Grid Inter-tie

Similar documents
Variable frequency transformer for asynchronous power transfer

ABB Wind Power Solution

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Renewable and Distributed Energy Resource Technologies

T5S4P3 Synchronous Condensers Application. Mr. Marco Schenone Mr. Sandro Tuscano Mr. Alessandro Oldrati

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

Evaluation of the Performance of Back-to-Back HVDC Converter and Variable Frequency Transformer for Power Flow Control in a Weak Interconnection

Universal Interconnection Technology Technology Roadmap Workshop. Associated Barriers to Distributed Generation

VFT Response to a Breaker Trip and Runback Event

SEL Microgrid Lessons Learned

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

PJM Generator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study September 2008

CHAPER 5 POWER FLOW STUDY IN THE INTEGRATED GRID NETWORK

More power for railway lines Maximum efficiency with proven system behavior

Implementing a Microgrid Using Standard Utility Control Equipment

Texas A&M Microgrid and Electrical System Study. Cushing Memorial Library & Archives

ABB Group August 27, 2010 Slide 1

SYSTEM INTEGRATION. Railway and urban transport electrification Energy-efficient and reliable solutions

Experience on Technical Solutions for Grid Integration of Offshore Windfarms

Sitras SCS, -RCI, -FFP, -TTU

ABB s new control and protection devices

2009 Wind-Diesel Workshop. Microgrid Control System Technology GE Digital Energy, Markham Ontario

Summary of Revision, IEEE C , Guide for Breaker Failure Protection of Power Circuit Breakers

PQC - STATCON The ultra fast Power Quality Compensator

MICROGRIDS DESIGNING AN IMPROVED GRID

Energy Storage and Other Energy Control Solutions

Modular Multilevel Submodules for Converters, from the State of the Art to Future Trends

OBJECTIVES LCC HVDC SYSTEMS VSC HVDC SYSTEMS COMMON EQUIPMENT DIFFERENT OPTIONS ECONOMIC IMPACTS CONCLUSIONS

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Development of Electrical Power System Simulator.

Power From Shore: An introduction to HVDC Light Offshore

WIND POWER ELECTRICAL DRIVE TRAINS. Lower your cost of energy with an optimized permanent magnet generator and full-power converter package

ELG4125: Flexible AC Transmission Systems (FACTS)

Essential Reliability Services From PV Plants

MCD 200 Series Soft Starters

Service and Rehabilitation Electrical Power Systems

Synchronous motor with fluid coupling drive arrangement for a preheater ID Fan. presenter Nathan Schachter CIMENTEC Engineering Ltd

Enabling the power of wind. Competence and expertise for wind power customers

S C ELECTRIC EUROPE LTD. Excellence Through Innovation. Harnessing the Wind. November 2011 Descriptive Bulletin E

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

CONNECTION ASSESSMENT & APPROVAL PROCESS. Cardinal Substation Modification of 115kV Substation

Refurbishment and Life Extension of Existing Facilities in Vermont

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE

Double earth fault in a PSP during back to back launching sequence

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation

Diversifying into Marine Energy. ABB March 2015

IEEE T&D FACTS Panel Session Part II (08TD0140) Wednesday, April 23, 2008

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Synchronous Condenser Conversions at FirstEnergy Eastlake Plant. C.R. SLATTERY FirstEnergy Corporation. J.M. FOGARTY General Electric Company USA

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

HVDC Back-to-Back Interconnections Enabling reliable integration of power system

ABB in Wind &Integration of renewables

KONČAR Group. Research and Development

Synchronous motor control. 8/15/2007 Powerflow Technologies Inc 1

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

SIMINE DRAG. Innovative solutions for maximum productivity and reliability. Mining Technologies

By Mahesh Morjaria, Dmitriy Anichkov, Vladimir Chadliev and Sachin Soni First Solar, Tempe, Arizona

2017 Southeastern Tri Regional SAME Training Symposium Microgrids What are they, lessons learned 8/30/2017 Dan Dorn Eaton Corp

Critical Power: What s New in Electrical Engineering: Smart Grid and Transformers. Sponsored by:

Unit Protection System for Pumped-Storage Power Stations

Modern Design for Variable Speed Motor-Generators:

Standards, Procedures and Policies for Grid Connection

Synchronous condenser solutions siemens.com/energy/facts

9. Examples of hydro energy conversion

Workshop on Grid Integration of Variable Renewable Energy: Part 1

Power delivery for industrial facilities

Simply Reliable Solutions for Continuous, High Quality Power Tradition. Technology. Innovation.

Back Up Power for Sochi

Grid-Friendly Utility-Scale PV Plants

SIMOBREAKER The New Substation with Rotary Disconnector Fully Assembled, Compact and with High Availability

Control System for a Diesel Generator and UPS

Grid Integration of Large Scale Wind and Solar

The step forward Onboard DC Grid

Targeted Application of STATCOM Technology in the Distribution Zone

Substation Concepts for the Future

Performance Analysis of Transient Stability on a Power System Network

The Application of Power Electronics to the Alberta Grid

Renewables & reliability: How Senvion s wind farms enhance grid stability in Canada

Integration of Large Wind Farms into Electric Grids

Pumped Storage Power Plants Solution

WELCOME! Today we d like to Introduce you to your North American Rotary UPS Solutions Partner!

Feasibility Study. Shaw Environmental, Inc. 12MW Landfill Gas Generation Interconnection. J.E.D. Solid Waste Management Facility. Holopaw Substation

Power Conversion System for ESS 100 kw to 30 MW Bi-directional Inverters

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

TECHNICALINFO. The LEITNER Drive System

ABB low voltage wind turbine converters Reliable technology for wind power

Versatile and Powerful. Liduro Wind Frequency Converter System

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

Pika Energy Island Made in America

IEEE SESSION COMPUTER AIDED SMART POWER GRID

Dynamic Control of Grid Assets

Grid Integration Costs: Impact of The IRP Capacity Mix on System Operations

ASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc.

Introducing the TM /

Grid Code Testing of Wind Turbines by VSC-based Test Equipment

4-Day Power System Analysis, Coordination, System Studies

Power Electronics

Crane and Hoist Solution Guide. The Advantage of Experience

Essential Reliability Services From PV Plants

Transcription:

GE Energy Variable Frequency Transformers Grid Inter-tie

Variable Frequency Transformers GE Energy revolutionizes the world of transmission solutions with its new Variable Frequency Transformer (VFT). The VFT provides a simpler way to control power between electrical grids than has previously been available. What Is the VFT? The VFT system is based on a combination of hydro generator and transformer technologies. It consists of a rotary transformer, for continuously controllable phase shift, together with a drive system and control, that adjust the angle and speed of the rotary transformer, to regulate the power flow through the VFT. What Function Does the VFT Provide? The VFT system provides a means to control power between two grids. The grids need not be synchronous. A common situation is where two grids of the same nominal frequency cannot economically be directly connected with ac lines. The VFT allows controlled power exchange between the grids, while retaining many of the inherent virtues of an ac interconnection. Low Complexity and Low Maintenance The simple design of the VFT components, based on established and widely used rotating machinery, ensures its long term maintainability. Use of common substation components; e.g., transformers, capacitors, breakers; allowing existing utility maintenance crews to be highly proficient. Low speed operation resulting in low maintenance requirements. Redundancy in auxiliary services; e.g., cooling fans. All main components are utilized for their low stress quality, resulting in high reliability. Independent operating channels allow maintenance on one unit while others remain operational. 1

VFT vs HVDC Back to Back When compared to existing technologies, the VFT provides self-standing Plug and Play capability to provide controlled transmission solutions, independent of grid interconnection considerations. The low grid interaction of the VFT, in terms of harmonics, control interactions, and impact on nearby generators, allows the installation and operation to be decoupled from other grid issues. Comparison of Technologies for Controllable Transmission of Electrical Power VFT HVDC VSC HVDC High Efficiency High Availability Low Complexity Low Maintenance Small Space Requirements Black Start Capability Low Control Interactions Low Harmonic Generation Low Impact on Adjacent Generators Modular Design Easy Integration with Grid Bump-less Startup Familiarity to Typical Power Engineer VFT Variable Frequency Transformer HVDC High-Voltage Direct Current VSC Voltage Source Converter Best in Class BLANK Industry Standard Unable to Perform 2

VFT Compact and Modular Design VFT Offers Compact Substation Layout The simplicity of the VFT, unlike traditional HVDC technology, lacks high-voltage filters and allows for a more compact substation design. The drawing illustrates this comparison, with a 200MW VFT station layout superimposed on a 200MW HVDC layout. VFT systems can be made very compact by using gas insulated switchgear. A recent project was designed for a 300MW VFT system fitting within a 70m x 70m area. Modular Design GE Energy has designed the VFT as a modular system in 100 MW channels. Each 100 MW channel operates independently providing for maintenance flexibility. First Commercial VFT Installation The first commercial installation of a VFT is at the Langlois transmission substation in Quebec, Canada. The substation is located in St.-Timothée, southwest of Montréal, near the borders of Ontario and New York State. TransÉnergie, the transmission division of Hydro-Québec, is able to transfer an additional 100MW of power to and from neighboring power grids. 130m 3

90m 1 6 100m 5 2 2 PSP30428-14 3 6 4 1 Rotary systems 130m 2 3 4 5 6 Main transformers Drive transformer VAR banks to yield unity power factor Control room High-voltage lines 4

60 59.8 5 0 50 Stator Frequency (Hz) Rotor Speed (RPM) VFT Power (MW) Operation & Control Steady-state power control is smooth and continuous, including at zero power. The remote operator sets the VFT s power command in a manner similar to dispatching generation on the system. Startup and shutdown are bump-less to the grid. The VFT s inertia smoothes responses to grid faults and transients, and looks much more like a transformer to the grid than a sensitive power-electronic device like HVDC. Grid studies and field tests show that the VFT inherently improves stability of adjacent electric power networks. VFT Control System The VFT uses field-proven GE utility and industrial digital control technologies. The control system is simpler and has far less electronics than HVDC. This means easier maintenance and support. The control system includes: 40 0 sec 20 sec 40 sec Nov. 1, 2003 Langlois VFT response to a Hydro- Quebec generator trip, while VFT was ramping. Redundant GE PowerLink Advantage HMI PC s provide for superior user interface & monitoring, multi-level dispatch, ramp rate setting and sequence of events recording Main control cabinet is based on a GE D200 substation automation platform for multiunit functions, SCADA interface for unmanned operation, and data concentration from individual protective devices and unit controls. Individual unit control cabinet, for each 100 MW unit utilizes GE Fanuc PLCs, GE s Multilin Universal Relays, and GE s Turbine Static Starter Control for the fast power and torque regulators. GE s DC2000 Drive System for shaft torque control. Each 100 MW unit can be operated at its individual unit control, without need for HMI, SCADA or main control cabinet 5

The rotary system is the heart of the VFT. It is comprised of an assembly of well-proven components and sub-systems to form this new offering. The machine design is based on a vertical, air-cooled concept for simplicity and reliability. VFT Rotary System includes: rotating transformer DC drive collector Rotor bus duct Air housing Three-phase collection DC torque drive motor DC motor ventilation fan Upper bearing Stator bus duct PSP30428-11 Rotating transformer ventilation fan Stator core Rotor core Windings/connections Lower thrust and guide bearing 6

GE Energy For more information, please visit our web site at gepower.com. GE Energy 4200 Wildwood Parkway Atlanta, GA 30339 GEA-13526B (08/04)