This product is not fuse protected. User is responsible for providing system protection. Consult factory for application information.

Similar documents
Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

(typ.) (Range) ±18 330# 89 MPW MPW

2W, Low Cost DIP, Dual Output DC/DC Converters

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

DH50 SERIES. DATASHEET Rev. A

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

Delphi D12S Non-Isolated Point of Load

Unit/Comments. %; Equal Output Loads %; Equal Output Loads Full Load

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

PG02S Series 2W DC/DC CONVERTER, SIP-Package

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

(typ.) (Range) Load

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

SH01S/D Series 1W DC/DC CONVERTER, SMD-Package

RCD15W Series PART NUMBER STRUCTURE

EB Series Eighth - Brick Up to 100 Watt DC-DC Converter

APPLICATIONS: AVAILABLE OPTIONS

OSR03-24 S 05 A Series Name Input Output Output Assembly Voltage Quantity Voltage Option PART NUMBER STRUCTURE

HBC DC-DC Series Data Sheet 300-Watt Half-Brick Converters

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Output Current Input Current Over Voltage. VDC VDC ma ma(typ.) ma(typ.) VDC μf % MKZI10-24S

S24SP series 40W Single Output DC/DC Converter

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

S24SP15004 series 60W Single Output DC/DC Converter

Features. Isolation PFM. Block Diagram

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM30-E)

LSS-T/10-W12. Adjustable Output 10 Amp SIP-mount DC/DC Converter. PRODUCT OVERVIEW FEATURES

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

Volant NEA/NEF010 Series

Features. Regulated Converters. RP20-F 20 Watt 2 x 1 Single & Dual Output. RP20- _F/ Package 4) Control Logic (3) DC/DC Converter

Application Note TES 1 Series

DCMCW60 SERIES FEATURES

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

HAE S 05 W - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW)

SELECTION GUIDE - SINGLE OUTPUT 1. Nominal Input Voltage Output Voltage

Sixteenth brick format 4:1 input voltage range 2.25kV basic isolation Remote ON/OFF and trim pins UVLO, OTP, OVP, OCP and SCP Efficiency up to 91%

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options

MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters

DEWS SERIES 25W-30W WIDE INPUT RANGE

DC/DC Converter URF48_QB-200W(F/H)R3 Series

MPP10-48 S 05 W A - P T Series Name Input Output Output Input Pin Connection Remote On/Off Trim Voltage Quantity Voltage Range Option Options Option

Efficiency Model dependant 86 ~ 88% Isolation. Isolation Cap. Switching Freq. Safety. Case Material Base Material Potting.

HQA DC-DC Power Module Series

Features. Applications

North America Asia-Pacific Europe, Middle East

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

Asia-Pacific Europe, Middle East North America Bel Power Solutions, Inc. BCD.

PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

MEE1 Series Isolated 1W Single Output DC/DC Converters

output Output Voltage min (ma)

MEA1 Series 1kVDC Isolated 1W Dual Output DC/DC Converters

DORADO MV DC/DC CONVERTERS 24V Input 12VDC 8A Output

DC/DC Converter URF48_QB-75W(F/H)R3 Series

Delphi Series IPM, Non-Isolated, Integrated

GQA DC-DC Power Module Series

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

PL10S-12 Non Isolated DC/DC Converters Long Form Datasheet

NON-ISOLATED DC/DC CONVERTERS

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

HQA DC-DC Power Module Series

Advance Data Sheet: i3a Series 1/32 nd brick Power Module. I3A Series DC/DC Power Modules 9-53V Input, 8A Output 100W 1/32nd Brick Power Module

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 91% Six-Sided Continuous Shield Available as Power Module (RPM60-G)

Not for New Design 10 WATT WD DUAL LOW INPUT SERIES DC/DC CONVERTERS. Features

QHW050F1, QHW075F1, and QHW100F1 Power Modules: dc-dc Converters; 36 to 75 Vdc Input, 3.3 Vdc Output; 33 W to 66 W

SQ24 Series DC-DC Converter Data Sheet VDC Input; Standard Outputs from 1-12 VDC

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Reflected ripple current. Case Temperature rise above ambient ABSOLUTE MAXIMUM RATINGS

NDS6 Series Isolated 6W Wide Input Single & Dual Output DC/DC Converters

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

4:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 87% Ultraminiature Open Frame SMD No Minimum Load Required

UL Certified RP30-FW

American Power Design, Inc.

NXE1 Series Isolated 1W Single Output SM DC/DC Converters

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

Features. Non Isolated Power Module ROF-78E ROF-78E - SMD-R. DC/DC Converter

CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters

Single Output LSN-W3 Models

UNS Series Non-Isolated, 3.3V & 5V, 3A DC/DC Converters

Delphi NC30 Series Non-Isolated Point of Load DC/DC Power Modules: 12Vin, 0.9V-5Vout, 30A

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

HM8202. The HM8202 is available in the SOP-8L package. Charging Docks Handheld Instruments Portable Computers

OBSOLETE SELECTION GUIDE 1. Recommended alternative: OKY-T/10-W5P-C >> click here to download the data sheet

Table 2 Models BST12M-0.7S03PDM BST12M-0.7S06PDM BST12M-0.7S10PDM Conditions Input voltage range

Series AM2F-Z 2 Watt DC-DC Converter

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Order Code. Voltage range. Reflected ripple current. Isolation test voltage

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

MEJ2 Series 5.2kVDC Isolated 2W DC/DC Converters

Transcription:

Features High output 10A 3.3V ±10%, 5V ±10% Input Regulation ±0.4% line and load Industry standard pin configuration High efficiency to 90% Remote Sense, Trim and Enable Short Circuit protection MTBF 2.9 million hours Can Source and Sink Output Current This product is not fuse protected. User is responsible for providing system protection. Consult factory for application information. Specifications * S111-03 S111-05 Input Specifications Input voltage range 3.3V ± 10%* 5.0V ± 10% Measured at +Vin pin External input capacitor Minimum 500 µf with adequate ripple current rating See also note on pg 8 and charts on pg 6 Output Specifications Standard output voltages 0.8V 0.9V 1.0V 1.2V 1.2V 1.5V 1.5V 1.8V 1.8V 2.1V 2.1V 2.5V 2.5V 3.3V Standard setpoint accuracy varies from ±1.5% at the low end of the output voltage range, to ±3% at the high end. (see chart on pg 2) Contact factory for tighter tolerances. See note on pg 7 for trimming to different voltages. Output current 10A 10A 200 LFM at 70 C (see also derating curves) Load regulation ±0.5% 0 to 10A load Line regulation ±0.5% Over specified input voltage range External output capacitor >150µF with maxesr = 100mΩ See also note on pg 8 Short circuit protection 13A (at 70 C) to 20A (at -40 C) General Specifications Enable *** ON-open or low / OFF-high (max 15V) Efficiency 90% typical See efficiency curves on pg 4 Isolation Non-isolated Switching frequency 300kHz Fixed Approvals and Standards UL 94V-0 Protection Fusing Unit is not fused. Operating Temperature **** -40 C to 70 C 200 LFM at 70 C (see also derating curves) Storage Temperature -40 C to 85 C Non-condensing Weight 0.3 oz (8.5 gm) MTBF 3.8 million hours Per RAC PRISM at 50 C ambient and 200 LFM * All specifications are typical at nominal input, full load at 25 C unless otherwise stated. *** Pull below 0.4V and sink greater than 50 µa or leave open to enable the SIP; pull above 2V (do not exceed 15V) and source greater than 150 µa to disable the SIP. **** The output capacitors must meet the max ESR = 100 mω requirement over the operating temperature range.

Part Number Designations S111-0520XYZ - BB Model Number Input Voltage 03 = 3.3V 05 = 5V Mechanical Options 2 = Vertical Top Side Pins (Standard) Consult Factory for Other Options Output Voltage XYZ = X.YZ Volts Pin Length B =.145 inch (Standard) Consult Factory for Other Options Feature Options* B = Remote Sense, Trim and Enable (Standard) Consult Factory for Other Options Set Point Tolerance 0 = Factory Standard (See Initial Setpoint Tolerances) * Pin present only on selected features. Initial Setpoint Tolerances Initial setpoint tolerance for 3.3V input SIP s Initial setpoint tolerance for 5V input SIP s Output Voltage (V) Output Voltage (V) Pin Assignments* CONNECTOR PIN FUNCTION 1 V OUT CONNECTOR PIN FUNCTION 1 Ground 2 V OUT J1 3* Remote Sense (Empty Optional) 4 V OUT 5 Ground * Pin present only when feature is selected. J2 2 V IN 3 V IN 4 Empty 5 Trim 6 Enable

Outline Drawings 2.55 (64.8) MAX 2.430 1 2 3 4 5 1 2 3 5 6 Topside.540.50 (12.7) (13.72) MAX MAX J1 J2.155 Pin Length MIN Option ±.02 (±.5) NOTE 3.100 (2.54) 1.800 TYP (45.72) 1.400 (35.56) 1.800 (45.72).28 (7.1).025 X.025 (0.64 X 0.64) S111-03 Mechanical Options 2 S111-05 Mechanical Options 2.435 MAX.255 MAX.110 MAX.390 MAX.245 MAX.072 MAX.03.03.03.03 Mech Option #2 (Standard) Mech Option #2 (Standard) 1. Dimensions are in inches and (millimeters). 2. Tolerances: (unless otherwise noted) Inches.XX ±.020.XXX ±.010 Millimeters.X ± 0.5.XX ± 0.25 Pin: ±.002 ± 0.05 3. Pin is present only if feature is selected. * Recommended Customer Hole Size 0.046 ±.003

Efficiency Curves at 25 C

Derating Curves No derating needed at 70 C with 200 LFM airflow or higher. * * Extended operation at greater than rated current may degrade reliability.

Ripple Current Approximate ripple current ratings required for input bulk capacitor

Resistor Trim Equations NOTE: For best results, the trimming range should not exceed +/-20% of the initial output voltage set by the factory (Vset). To trim down to 0.6V, units with an initial output voltage of up to 1.2V can be used. Trimming UP raising the output voltage using a resistor from Trim to Ground. 3.3Vin 5Vin Rtrim = 1992 ( Vout Vset ) Rtrim = 500 ( 1 + Vset Vout ) ( Vset Vout ) Vout max = 2.5V Vout max = Vset + 1 as Rtrim approaches 0Ω. Trimming DOWN lowering the output voltage using a resistor from Trim to an external voltage reference or to the Vout pins. 3.3Vin 5Vin Rtrim = 498 (4 5 Vref ) ( Vout Vset ) Rtrim = 500 ( 1 Vset + Vout + Vref ) ( Vset + Vout ) Vout min = 0.5V Vout min = Vset (Vref 1) as Rtrim approaches 0Ω. Where: Vout is the desired output voltage. Vset is the output voltage setpoint (output voltage without trim). Vref is the reference voltage for the trim resistor when trimming down. If using Vout for this purpose, then Vref = Vout. Rtrim is the resistance value of the trim resistor (ohms).

External Capacitance for SIP Products All SIP products require external capacitance to be placed on the system board that the SIP will be designed into. This application note is an attempt to explain how to translate datasheet information and apply it to a system level board design. Input Capacitance Although input capacitance value is not critical, the input capacitors must be capable of storing fairly large amounts of energy. This means, for example, small ceramic capacitors would be inappropriate. The primary criteria, though, for choosing the input capacitors is AC ripple current rating. The SIP datasheet contains a chart showing ripple current vs. output current (or output power). The system designer determines the maximum SIP output current required from the SIP. Based on that number, the chart will show a corresponding ripple current rating the designer needs to plan for when choosing input capacitors. Example using SIP S111-03 for 1.2 V output: The designer knows the S111 output current will be maximum 8 A in his application. The ripple current chart (3.3V input) shows a 5 A rating required for the input capacitor. Also known is that the capacitor the designer hopes to use has a ripple current rating of 3A. Therefore, the designer must use two of the chosen capacitors in parallel for a total ripple current capability of 6A. This will adequately cover the 5 A need. Output Capacitance The only requirement for capacitance value is for basic circuit stability of the SIP. That value is specified on the SIP datasheet usually 150µF. The other consideration for the output capacitor is the total ESR (Equivalent Series Resistance). As with ripple current, every capacitor has a specified ESR. When using multiple capacitors in parallel, this ESR is added exactly like parallel resistors. Therefore, more capacitors mean less ESR. The SIP datasheet specifies a maximum total ESR necessary for optimum SIP performance. The designer may also choose to add more capacitance to reduce output ripple and noise. Example: The datasheet specifies a maximum ESR of 100mΩ for output capacitance. The system designer wants to use a capacitor with a specified ESR of 130mΩ. Since 130mΩ is more than the needed 100mΩ, two capacitors must be used in parallel for a total effective ESR of 65mΩ. Generally, good, low ESR bulk capacitors are recommended for both input and output capacitance so that fewer capacitors are needed since board real estate is usually an important factor in today's designs.

Impact on Output Voltage Ripple and Transient Response If the customer s application requires a very low output voltage ripple and / or very low output voltage overshoot / undershoot during transients, then the guidelines previously shown need to be exceeded and good layout practices become mandatory. By using four 330 µf OSCON capacitors, each having ESR = 17 mω, the output voltage ripple can be decreased to 50 mvpk-pk on a 1.2V output SIP. Also during a transient load condition (load current steps from 20% to 100% and back, at 2 A / µsec) the output voltage does not overshoot / undershoot more than 100mV. When fast and deep transient loads are expected, the input capacitor becomes important as well, especially if the SIP is far from its input voltage source. Capacitors having as much as 2000 µf and combined ESR lower than 20 mω might be needed. Practical results heavily depend on physical layout and specific load conditions. For critical applications the customer is encouraged to consult with the manufacturer.